Anandram Venkatasubramanian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Anandram Venkatasubramanian has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Wayne K. Hiebert
National Institute for Nanotechnology, 11421 Saskatchewan Drive, Edmonton T6G 2M9, Alberta, Canada
4 shared publications - Jocelyn N. Westwood-Bachman
Applied Nanotools, Edmonton, Canada
2 shared publications - Matthew P. Maksymowych
Department of Applied Physics and Ginzton Laboratory, Stanford University, Stanford, USA
2 shared publications - Abhijit Mookerjee
Department of Medical Oncology, Lab Oncology and Bio-statistics, All India Institute of Medical Sciences, New Delhi 110029, India
1 shared publication - David Scott Wishart
Department of Biological Sciences, University of Alberta, Edmonton, AB T6G 2E9, Canada
1 shared publication - Indra Dasgupta
Indian Association for the Cultivation of Science
1 shared publication
Latest Publications
- 1 May 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-01 (31) , 2324
Nano-Optomechanical Systems (NOMS) for Gas Chromatography Sensing
Nano-optomechanical systems (NOMS) achieve high-precision measurement of displacement which enables very high sensitivity through mechanical resonance-shift sensing. A recent breakthrough [1] has shown that NOMS devices can operate in high-damping environment without sacrificing their frequency stability and sensing resolution. This is because stability losses from lower quality factor (Q) are offset by stability gains from a larger intrinsic signal-to-noise ratio. We take advantage of this excellent stability to do atmospheric pressure resonant mechanical gas sensing with high sensitivity using NOMS [2]. In particular, we have set up a traditional gas chromatograph to output to a NOMS detector and shown parts-per-billion level detection [2]. By modifying the NOMS devices to make the silicon cantilevers porous, we have improved sensitivity by a further factor of 10 [3]. The next challenge, and opportunity, in using NOMS for mass sensing, is to separate the gas loading signals that affect both the mechanical and optical resonances in high optomechanical-coupling devices [4]. This is because, at high coupling, changes in optical resonance produce changes in mechanical resonance and vice versa. This effect can be used to amplify the sensing signal obtained when measuring mechanical frequency changes. In fact, it scales particularly well with high-finesse optical cavities and could lead to a situation where evanescent field gas loading on the optical cavity is transduced as a mechanical frequency shift with orders of magnitude better mass sensitivity than could be realized from the NEMS alone or the optical cavity alone. As an example, our present mass loading sensitivity is around 50 kDa [5]; improving the cavity linewidth merely by a factor of 10 should shrink that mass sensitivity by a factor of 1000, bringing it down to 50 Da. This level of sensitivity would allow studying chemical adsorption and desorption of individual gas chromatography molecules on the sensor surface and could provide a simple path for obtaining orthogonal information in gas chromatography detectors. [1] S. K. Roy, V. T. K. Sauer, J. N. Westwood-Bachman, A. Venkatasubramanian, and W. K. Hiebert, Improving mechanical sensor performance through larger damping. Science 360, eaar5220 (2018); doi: 10.1126/science.aar5220. [2] A. Venkatasubramanian, et al., Nano-optomechanical systems for gas chromatography. Nano Lett. 16, 6975-6981 (2016); doi: 10.1021/acs.nanolett.6b03066. [3] A. Venkatasubramanian, et al., Porous nanophotonic optomechanical beams for enhanced mass adsorption. ACS sensors 4, 1197-1202 (2018); doi: 10.1021/acssensors.8b01366. [4] M. P. Maksymowych, J. N. Westwood-Bachman, A. Venkatasubramanian, and W. K. Hiebert, Optomechanical spring enhanced mass sensing. Appl. Phys. Lett. 115, 101103 (2019); doi: 10.1063/1.5117159 [5] Da = Dalton = 1 amu = 1 atomic mass unit ~ 1.66 x 10-27 kg.
- 1 May 2020
- Published by The Electrochemical Society in ECS Meeting Abstracts
- Vol. MA2020-01 (31) , 2324
Nano-Optomechanical Systems (NOMS) for Gas Chromatography Sensing
Nano-optomechanical systems (NOMS) achieve high-precision measurement of displacement which enables very high sensitivity through mechanical resonance-shift sensing. A recent breakthrough [1] has shown that NOMS devices can operate in high-damping environment without sacrificing their frequency stability and sensing resolution. This is because stability losses from lower quality factor (Q) are offset by stability gains from a larger intrinsic signal-to-noise ratio. We take advantage of this excellent stability to do atmospheric pressure resonant mechanical gas sensing with high sensitivity using NOMS [2]. In particular, we have set up a traditional gas chromatograph to output to a NOMS detector and shown parts-per-billion level detection [2]. By modifying the NOMS devices to make the silicon cantilevers porous, we have improved sensitivity by a further factor of 10 [3]. The next challenge, and opportunity, in using NOMS for mass sensing, is to separate the gas loading signals that affect both the mechanical and optical resonances in high optomechanical-coupling devices [4]. This is because, at high coupling, changes in optical resonance produce changes in mechanical resonance and vice versa. This effect can be used to amplify the sensing signal obtained when measuring mechanical frequency changes. In fact, it scales particularly well with high-finesse optical cavities and could lead to a situation where evanescent field gas loading on the optical cavity is transduced as a mechanical frequency shift with orders of magnitude better mass sensitivity than could be realized from the NEMS alone or the optical cavity alone. As an example, our present mass loading sensitivity is around 50 kDa [5]; improving the cavity linewidth merely by a factor of 10 should shrink that mass sensitivity by a factor of 1000, bringing it down to 50 Da. This level of sensitivity would allow studying chemical adsorption and desorption of individual gas chromatography molecules on the sensor surface and could provide a simple path for obtaining orthogonal information in gas chromatography detectors. [1] S. K. Roy, V. T. K. Sauer, J. N. Westwood-Bachman, A. Venkatasubramanian, and W. K. Hiebert, Improving mechanical sensor performance through larger damping. Science 360, eaar5220 (2018); doi: 10.1126/science.aar5220. [2] A. Venkatasubramanian, et al., Nano-optomechanical systems for gas chromatography. Nano Lett. 16, 6975-6981 (2016); doi: 10.1021/acs.nanolett.6b03066. [3] A. Venkatasubramanian, et al., Porous nanophotonic optomechanical beams for enhanced mass adsorption. ACS sensors 4, 1197-1202 (2018); doi: 10.1021/acssensors.8b01366. [4] M. P. Maksymowych, J. N. Westwood-Bachman, A. Venkatasubramanian, and W. K. Hiebert, Optomechanical spring enhanced mass sensing. Appl. Phys. Lett. 115, 101103 (2019); doi: 10.1063/1.5117159 [5] Da = Dalton = 1 amu = 1 atomic mass unit ~ 1.66 x 10-27 kg.
- 2 September 2019
- Published by AIP Publishing in Applied Physics Letters
- Vol. 115 (10) , 101103
Optomechanical spring enhanced mass sensing
On-chip nano-optomechanical systems (NOMS) have demonstrated a zeptogram-level mass sensitivity and are promising candidates for low-cost implementations in areas such as metabolite quantitation and chemical analysis. High responsivity and sensitivity call for substantial optomechanical coupling and cavity finesse, resulting in detuning-dependent stiffness and mechanical damping via optomechanical back-action. Since mass loading (or temperature or force change) can alter both mechanical and cavity properties, mechanical frequency shifts induced by loading can encompass both effects. Precision sensing requires understanding and quantifying the source of the frequency tuning. Here, we show the deconvolution of direct loading and optomechanical stiffness change on the mechanical eigenfrequency as a function of detuning for a nano-optomechanical sensor in gaseous sensing experiments. Responses were generally dominated by shifts in optical stiffness and resulted in a mass loading signal amplification by as much as a factor of 2.5. This establishes an alternative possible route toward better mass sensitivity in NOMS while confirming the importance of incorporating optical stiffness effects for precision mass sensing.
- 2 September 2019
- Published by AIP Publishing in Applied Physics Letters
- Vol. 115 (10) , 101103
Optomechanical spring enhanced mass sensing
On-chip nano-optomechanical systems (NOMS) have demonstrated a zeptogram-level mass sensitivity and are promising candidates for low-cost implementations in areas such as metabolite quantitation and chemical analysis. High responsivity and sensitivity call for substantial optomechanical coupling and cavity finesse, resulting in detuning-dependent stiffness and mechanical damping via optomechanical back-action. Since mass loading (or temperature or force change) can alter both mechanical and cavity properties, mechanical frequency shifts induced by loading can encompass both effects. Precision sensing requires understanding and quantifying the source of the frequency tuning. Here, we show the deconvolution of direct loading and optomechanical stiffness change on the mechanical eigenfrequency as a function of detuning for a nano-optomechanical sensor in gaseous sensing experiments. Responses were generally dominated by shifts in optical stiffness and resulted in a mass loading signal amplification by as much as a factor of 2.5. This establishes an alternative possible route toward better mass sensitivity in NOMS while confirming the importance of incorporating optical stiffness effects for precision mass sensing.
- 3 April 2019
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 4 (5) , 1197-1202
Porous Nanophotonic Optomechanical Beams for Enhanced Mass Adsorption
We have developed a porous silicon nanocantilever for a nano-optomechanical system (NOMS) with a universal sensing surface for enhanced sensitivity. Using electron beam lithography, we selectively applied a V2O5/HF stain etch to the mechanical elements while protecting the silicon-on-insulator photonic ring resonators. This simple, rapid, and electrodeless approach generates tunable device porosity simultaneously with the mechanical release step. By controlling the porous etchant concentration and etch time, the porous etch depth, resonant frequency and the adsorption surface area could be precisely manipulated. Using this control, cantilever sensors ranging from non-porous to fully porous were fabricated and tested as gas-phase mass sensors of volatile organic compounds coming from a gas chromatography stream. The fully porous cantilever produced a dramatic 10-fold increase in sensing signal and a 6-fold improvement in limit of detection (LOD) compared to an otherwise identical non-porous cantilever. This signal improvement could be separated into mass responsivity increase and adsorption increase components. Allan deviation measurements indicate that a further 4-fold improvement in LOD could be expected upon speeding up characteristic peak response time from 1 s to 50 ms. These results show promise for performance enhancement in nanomechanical sensors for applications in gas sensing, gas chromatography, and mass spectrometry.
- 3 April 2019
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 4 (5) , 1197-1202
Porous Nanophotonic Optomechanical Beams for Enhanced Mass Adsorption
We have developed a porous silicon nanocantilever for a nano-optomechanical system (NOMS) with a universal sensing surface for enhanced sensitivity. Using electron beam lithography, we selectively applied a V2O5/HF stain etch to the mechanical elements while protecting the silicon-on-insulator photonic ring resonators. This simple, rapid, and electrodeless approach generates tunable device porosity simultaneously with the mechanical release step. By controlling the porous etchant concentration and etch time, the porous etch depth, resonant frequency and the adsorption surface area could be precisely manipulated. Using this control, cantilever sensors ranging from non-porous to fully porous were fabricated and tested as gas-phase mass sensors of volatile organic compounds coming from a gas chromatography stream. The fully porous cantilever produced a dramatic 10-fold increase in sensing signal and a 6-fold improvement in limit of detection (LOD) compared to an otherwise identical non-porous cantilever. This signal improvement could be separated into mass responsivity increase and adsorption increase components. Allan deviation measurements indicate that a further 4-fold improvement in LOD could be expected upon speeding up characteristic peak response time from 1 s to 50 ms. These results show promise for performance enhancement in nanomechanical sensors for applications in gas sensing, gas chromatography, and mass spectrometry.
- 15 June 2018
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 360 (6394)
Improving mechanical sensor performance through larger damping
Reconsidering resonator sensing: Changes in the frequency of a nanoscale mechanical resonator can be used for many sensing applications, provided that there is an adequate signal-to-noise ratio. Normally, this ratio is improved by creating resonators with higher quality factors that “ring” for longer times. Taking a cue from the approaches used in atomic force microscopy, Roy et al. show that if the thermomechanical noise of the resonator is well defined, the signal-to-noise ratio of the frequency shift can improve by lowering the quality factor. They used this approach to demonstrate temperature sensing with a double-clamped silicon beam resonator, which performed better at ambient pressures than in a vacuum. Science , this issue p. eaar5220
- 15 June 2018
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 360 (6394)
Improving mechanical sensor performance through larger damping
Reconsidering resonator sensing: Changes in the frequency of a nanoscale mechanical resonator can be used for many sensing applications, provided that there is an adequate signal-to-noise ratio. Normally, this ratio is improved by creating resonators with higher quality factors that “ring” for longer times. Taking a cue from the approaches used in atomic force microscopy, Roy et al. show that if the thermomechanical noise of the resonator is well defined, the signal-to-noise ratio of the frequency shift can improve by lowering the quality factor. They used this approach to demonstrate temperature sensing with a double-clamped silicon beam resonator, which performed better at ambient pressures than in a vacuum. Science , this issue p. eaar5220
- 22 June 2009
- Published by American Physical Society (APS) in Physical Review B
- Vol. 79 (22) , 224204
Augmented space recursion study of the effect of disorder on superconductivity
We present a real-space approach to study the effect of disorder on superconductivity. The method is based on augmented space formalism that goes beyond mean-field approximations for configuration averaging and effectively deals with the influence of configuration fluctuations of the neighborhood of an atom. In the regime of validity of Anderson’s theorem our results for - and -wave dirty superconductors have excellent agreement with existing results. The formalism is extended and tested for random negative Hubbard model. Having verified the reliability of our method we use it to study environment-dependent inhomogeneous randomness in disordered superconducting systems.- 22 June 2009
- Published by American Physical Society (APS) in Physical Review B
- Vol. 79 (22) , 224204
Augmented space recursion study of the effect of disorder on superconductivity
We present a real-space approach to study the effect of disorder on superconductivity. The method is based on augmented space formalism that goes beyond mean-field approximations for configuration averaging and effectively deals with the influence of configuration fluctuations of the neighborhood of an atom. In the regime of validity of Anderson’s theorem our results for - and -wave dirty superconductors have excellent agreement with existing results. The formalism is extended and tested for random negative Hubbard model. Having verified the reliability of our method we use it to study environment-dependent inhomogeneous randomness in disordered superconducting systems.