Edward Vineyard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Edward Vineyard has a total of 55 co-authors. Here are the top co-authors by number of shared publications:
- Omar Abdelaziz
Mechanical Engineering Department, The American University in Cairo, New Cairo 11835, Egypt
5 shared publications Abdolreza Zaltash
Oak Ridge National Laboratory, Oak Ridge, TN
3 shared publicationsAaron Thornton
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
2 shared publicationsAndrei Petrov
Oak Ridge National Laboratory, Oak Ridge, TN
2 shared publicationsBo Shen
Building Technologies Research and Integration Center, Oak Ridge National Laboratory , P.O. Box 2008 MS6070, Oak Ridge , TN , 37831-6070 , USA
2 shared publicationsJason Schmidt
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
2 shared publications
Latest Publications
- Open Access
- 1 September 2023
- Published by Office of Scientific and Technical Information (OSTI)
BTRIC Technical Support for Appalachia: FY 2023 Summary Report on Net Negative Carbon Building Demonstration with AgPod
This study investigates the effects of various concentrations of carbon dioxide (CO2) on the photosynthesis and biomass accumulation of crops growing in an Agricultural Pod (AgPod). The initial test crop was kale. It has been found that increasing the CO2 concentration in the AgPod promotes higher photosynthetic rates in kale plants up to 1300 ppm (highest CO2 concentration). An interesting finding was that net photosynthetic rates of kale leaves remain unsaturated until unusually high levels of photosynthetically active radiation (PAR, > 1200 µmolm-2s-1) and CO2 concentration (> 1100 ppm) are reached. Such high levels of saturating PAR and CO2 concentration values rarely occur under natural conditions, suggesting a promising potential for carbon capture via enriched greenhouse crop production. This task is one part of an overall plan to incorporate an AgPod to utilize carbon captured from the atmosphere to achieve net negative carbon emissions in a small neighborhood or community.
- 1 September 2023
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessBTRIC Technical Support for Appalachia: FY 2023 Summary Report on Net Negative Carbon Building Demonstration with AgPod
This study investigates the effects of various concentrations of carbon dioxide (CO2) on the photosynthesis and biomass accumulation of crops growing in an Agricultural Pod (AgPod). The initial test crop was kale. It has been found that increasing the CO2 concentration in the AgPod promotes higher photosynthetic rates in kale plants up to 1300 ppm (highest CO2 concentration). An interesting finding was that net photosynthetic rates of kale leaves remain unsaturated until unusually high levels of photosynthetically active radiation (PAR, > 1200 µmolm-2s-1) and CO2 concentration (> 1100 ppm) are reached. Such high levels of saturating PAR and CO2 concentration values rarely occur under natural conditions, suggesting a promising potential for carbon capture via enriched greenhouse crop production. This task is one part of an overall plan to incorporate an AgPod to utilize carbon captured from the atmosphere to achieve net negative carbon emissions in a small neighborhood or community.
- 1 August 2023
- Published by Office of Scientific and Technical Information (OSTI)
Building Technologies Office 03.02.02.38 Milestone Report — Technology Options for Low Environmental Impact Air-Conditioning and Refrigeration Systems
Due to increasing concerns about global warming, various environmental regulations will eventually phase out refrigerants used in air conditioning and refrigeration systems (e.g., R-410A, R-404A). Several refrigerants have been proposed as replacements, offering a variety of global warming potential (GWP), levels of energy efficiency and flammability. Some of these options are synthetic HFC/HFO mixtures such as R-454C and R-455A while other are commonly called naturals such as R-290 (Propane) and R-744 (Carbon Dioxide). This study discusses the merits of the leading options for air Conditioning and refrigeration systems. The fundamental requirements (environmental, performance, safety) are employed to fairly evaluate these options. Performance data and Life Cycle analysis results for these options are presented. Overall, this study provides information needed to judge the prospects of getting adequate replacement for R-410A and R-404A in a long-term sustainable basis.
- 1 August 2023
- Published by Office of Scientific and Technical Information (OSTI)
Building Technologies Office 03.02.02.38 Milestone Report — Technology Options for Low Environmental Impact Air-Conditioning and Refrigeration Systems
Due to increasing concerns about global warming, various environmental regulations will eventually phase out refrigerants used in air conditioning and refrigeration systems (e.g., R-410A, R-404A). Several refrigerants have been proposed as replacements, offering a variety of global warming potential (GWP), levels of energy efficiency and flammability. Some of these options are synthetic HFC/HFO mixtures such as R-454C and R-455A while other are commonly called naturals such as R-290 (Propane) and R-744 (Carbon Dioxide). This study discusses the merits of the leading options for air Conditioning and refrigeration systems. The fundamental requirements (environmental, performance, safety) are employed to fairly evaluate these options. Performance data and Life Cycle analysis results for these options are presented. Overall, this study provides information needed to judge the prospects of getting adequate replacement for R-410A and R-404A in a long-term sustainable basis.
- 20 January 2019
- Published by Office of Scientific and Technical Information (OSTI)
VOLTTRON-enabled Home Energy Management System
The U.S. Department of Energy's Office of Scientific and Technical Information
- 20 January 2019
- Published by Office of Scientific and Technical Information (OSTI)
VOLTTRON-enabled Home Energy Management System
The U.S. Department of Energy's Office of Scientific and Technical Information
- 1 July 2016
- Published by Elsevier in Applied Thermal Engineering
- Vol. 104, 818-828
Feasibility and operating costs of an air cycle for CCHP in a fast food restaurant
- 1 July 2016
- Published by Elsevier in Applied Thermal Engineering
- Vol. 104, 818-828
Feasibility and operating costs of an air cycle for CCHP in a fast food restaurant
- 14 November 2014
- Published by ASME International
Thermofluid Analysis of the Magnetocaloric Refrigeration
While there have been extensive studies on thermofluid characteristics of different magnetocaloric refrigeration systems, a conclusive optimization study using non-dimensional parameters which can be applied to a generic system has not been reported yet. In this study, a numerical model has been developed for optimization of active magnetic refrigerator (AMR). This model is computationally efficient and robust, making it appropriate for running the thousands of simulations required for parametric study and optimization. The governing equations have been non-dimensionalized and numerically solved using finite difference method. A parametric study on a wide range of non-dimensional numbers has been performed. While the goal of AMR systems is to improve the performance of competitive parameters including COP, cooling capacity and temperature span, new parameters called “AMR performance index-1” have been introduced in order to perform multi objective optimization and simultaneously exploit all these parameters. The multi-objective optimization is carried out for a wide range of the non-dimensional parameters. The results of this study will provide general guidelines for designing high performance AMR systems.
- 14 November 2014
- Published by ASME International
Thermofluid Analysis of the Magnetocaloric Refrigeration
While there have been extensive studies on thermofluid characteristics of different magnetocaloric refrigeration systems, a conclusive optimization study using non-dimensional parameters which can be applied to a generic system has not been reported yet. In this study, a numerical model has been developed for optimization of active magnetic refrigerator (AMR). This model is computationally efficient and robust, making it appropriate for running the thousands of simulations required for parametric study and optimization. The governing equations have been non-dimensionalized and numerically solved using finite difference method. A parametric study on a wide range of non-dimensional numbers has been performed. While the goal of AMR systems is to improve the performance of competitive parameters including COP, cooling capacity and temperature span, new parameters called “AMR performance index-1” have been introduced in order to perform multi objective optimization and simultaneously exploit all these parameters. The multi-objective optimization is carried out for a wide range of the non-dimensional parameters. The results of this study will provide general guidelines for designing high performance AMR systems.
- 12 September 2013
- Published by Taylor & Francis in HVAC&R Research
- Vol. 19 (7) , 847-856
System modeling and building energy simulations of gas engine driven heat pump
To improve the system performance of a gas engine driven heat pump system, an analytical modeling and experimental study has been made by using a desiccant system in cooling operation (particularly in high-humidity operations) and suction line waste heat recovery to augment heating capacity and efficiency. The overall performance of a gas engine driven heat pump system has been simulated with a detailed vapor compression heat pump system design model. The modeling includes (1) a gas engine driven heat pump cycle without any performance improvements (suction liquid heat exchange and heat recovery) as a baseline (both in cooling and heating mode), (2) a gas engine driven heat pump cycle in cooling mode with a desiccant system regenerated by waste heat from the engine incorporated, and (3) a gas engine driven heat pump cycle in heating mode with heat recovery (recovered heat from engine). According to the system modeling results, by using the desiccant system, the sensible heat ratio can be lowered to 40%. The waste heat of the gas engine can boost the space heating efficiency by 25% at rated operating conditions. In addtion, using EnergyPlus, building energy simulations have been conducted to assess annual energy consumptions of the gas engine driven heat pump in 16 U.S. cities, and the performances are compared to a baseline unit that has a electrically driven air conditioner with the seasonal coefficient of performance of 4.1 for space cooling and a gas furnace with 90% fuel efficiency for space heating.
- 12 September 2013
- Published by Taylor & Francis in HVAC&R Research
- Vol. 19 (7) , 847-856
System modeling and building energy simulations of gas engine driven heat pump
To improve the system performance of a gas engine driven heat pump system, an analytical modeling and experimental study has been made by using a desiccant system in cooling operation (particularly in high-humidity operations) and suction line waste heat recovery to augment heating capacity and efficiency. The overall performance of a gas engine driven heat pump system has been simulated with a detailed vapor compression heat pump system design model. The modeling includes (1) a gas engine driven heat pump cycle without any performance improvements (suction liquid heat exchange and heat recovery) as a baseline (both in cooling and heating mode), (2) a gas engine driven heat pump cycle in cooling mode with a desiccant system regenerated by waste heat from the engine incorporated, and (3) a gas engine driven heat pump cycle in heating mode with heat recovery (recovered heat from engine). According to the system modeling results, by using the desiccant system, the sensible heat ratio can be lowered to 40%. The waste heat of the gas engine can boost the space heating efficiency by 25% at rated operating conditions. In addtion, using EnergyPlus, building energy simulations have been conducted to assess annual energy consumptions of the gas engine driven heat pump in 16 U.S. cities, and the performances are compared to a baseline unit that has a electrically driven air conditioner with the seasonal coefficient of performance of 4.1 for space cooling and a gas furnace with 90% fuel efficiency for space heating.
- 12 September 2013
- Published by Taylor & Francis in HVAC&R Research
- Vol. 19 (7) , 836-846
Development of 20 integrated energy efficiency ratio rooftop units—system modeling and building energy simulations
Based on a detailed steady-state system and component modeling, a rooftop unit system design was developed that is can achieve an integrated energy efficiency rating higher than 20. Fin-and-tube and microchannel heat exchangers were modeled using a segment-to-segment approach, and an AHRI 10-coefficient compressor map used to simulate compressor performance. The system modeling is based on a component-based modeling approach, which facilitates flexible simulation of complicated system configurations. Starting with a baseline system having integrated energy efficiency rating of 16.6, numerous technical options were extensively investigated, i.e., varying compressor sizes, heat exchanger fin densities, fin-and-tube or microchannel heat exchanger, suction line heat exchanger, desiccant wheel, tandem compressor (TD), variable-speed compressor (VS), and condenser evaporative pre-cooling; an innovative system configuration was developed by combining a tandem compression system with a variable-speed compression system. The combined system can achieve a high integrated energy efficiency ratio as well as process the outdoor ventilation air over an extensive range. The design concept for a 20-ton (70.4-kW) unit, as well as a 10-ton (35.2-kW) unit was successfully evaluated. All selected components are readily accessible on the market, and performance predictions were validated against existing rooftop unit products at the rating condition. This article illustrates a potentially cost-effective high integrated energy efficiency ratio rooftop unit design. In addtion, extensive building energy simulations were conducted using EnergyPlus to predict seasonal energy saving potentials and peak power reductions using the high integrated energy efficiency ratio rooftop unit in 16 U.S. cities in comparison to a rooftop unit with a minimum efficiency.
- 12 September 2013
- Published by Taylor & Francis in HVAC&R Research
- Vol. 19 (7) , 836-846
Development of 20 integrated energy efficiency ratio rooftop units—system modeling and building energy simulations
Based on a detailed steady-state system and component modeling, a rooftop unit system design was developed that is can achieve an integrated energy efficiency rating higher than 20. Fin-and-tube and microchannel heat exchangers were modeled using a segment-to-segment approach, and an AHRI 10-coefficient compressor map used to simulate compressor performance. The system modeling is based on a component-based modeling approach, which facilitates flexible simulation of complicated system configurations. Starting with a baseline system having integrated energy efficiency rating of 16.6, numerous technical options were extensively investigated, i.e., varying compressor sizes, heat exchanger fin densities, fin-and-tube or microchannel heat exchanger, suction line heat exchanger, desiccant wheel, tandem compressor (TD), variable-speed compressor (VS), and condenser evaporative pre-cooling; an innovative system configuration was developed by combining a tandem compression system with a variable-speed compression system. The combined system can achieve a high integrated energy efficiency ratio as well as process the outdoor ventilation air over an extensive range. The design concept for a 20-ton (70.4-kW) unit, as well as a 10-ton (35.2-kW) unit was successfully evaluated. All selected components are readily accessible on the market, and performance predictions were validated against existing rooftop unit products at the rating condition. This article illustrates a potentially cost-effective high integrated energy efficiency ratio rooftop unit design. In addtion, extensive building energy simulations were conducted using EnergyPlus to predict seasonal energy saving potentials and peak power reductions using the high integrated energy efficiency ratio rooftop unit in 16 U.S. cities in comparison to a rooftop unit with a minimum efficiency.
- Open Access
- 1 June 2012
- Published by Elsevier in International Journal of Sustainable Built Environment
- Vol. 1 (1) , 85-101
Status of not-in-kind refrigeration technologies for household space conditioning, water heating and food refrigeration
- 1 June 2012
- Published by Elsevier in International Journal of Sustainable Built Environment
- Vol. 1 (1) , 85-101
Open AccessStatus of not-in-kind refrigeration technologies for household space conditioning, water heating and food refrigeration
- 1 December 2011
- Published by Elsevier in Applied Thermal Engineering
- Vol. 31 (17-18) , 3748-3760
Advances in household appliances- A review
- 1 December 2011
- Published by Elsevier in Applied Thermal Engineering
- Vol. 31 (17-18) , 3748-3760
Advances in household appliances- A review