HXHui Xia

Hui Xia

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Hui Xia has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A portable system for processing donated whole blood into high quality components without centrifugation

    by Sean C Gifford, Briony C Strachan, Hui Xia, Eszter Vörös, Kian Torabian, Taylor A Tomasino, Gary D Griffin, Benjamin Lichtiger, Fleur M Aung, Sergey S Shevkoplyas

    The use of centrifugation-based approaches for processing donated blood into components is routine in the industrialized world, as disparate storage conditions require the rapid separation of ‘whole blood’ into distinct red blood cell (RBC), platelet, and plasma products. However, the logistical complications and potential cellular damage associated with centrifugation/apheresis manufacturing of blood products are well documented. The objective of this study was to evaluate a proof-of-concept system for whole blood processing, which does not employ electromechanical parts, is easily portable, and can be operated immediately after donation with minimal human labor. In a split-unit study (n = 6), full (~500mL) units of freshly-donated whole blood were divided, with one half processed by conventional centrifugation techniques and the other with the new blood separation system. Each of these processes took 2–3 hours to complete and were performed in parallel. Blood products generated by the two approaches were compared using an extensive panel of cellular and plasma quality metrics. Comparison of nearly all RBC parameters showed no significant differences between the two approaches, although the portable system generated RBC units with a slight but statistically significant improvement in 2,3-diphosphoglyceric acid concentration (p < 0.05). More notably, several markers of platelet damage were significantly and meaningfully higher in products generated with conventional centrifugation: the increase in platelet activation (assessed via P-selectin expression in platelets before and after blood processing) was nearly 4-fold higher for platelet units produced via centrifugation, and the release of pro-inflammatory mediators (soluble CD40-ligand, thromboxane B2) was significantly higher for centrifuged platelets as well (p < 0.01). This study demonstrated that a simple, passive system for separating donated blood into components may be a viable alternative to centrifugation—particularly for applications in remote or resource-limited settings, or for patients requiring highly functional platelet product.


  • Open Access

    Towards bedside washing of stored red blood cells: a prototype of a simple apparatus based on microscale sedimentation in normal gravity

    by G. Khanal, R. A. Huynh, K. Torabian, H. Xia, E. Vörös, S. S. Shevkoplyas

    Background and Objectives: Infusion of by‐products of red blood cell (RBC) storage‐induced degradation as well as of the residual plasma proteins and the anticoagulant‐preservative solution contained in units of stored blood serve no therapeutic purpose and may be harmful to some patients. Here, we describe a prototype of a gravity‐driven system for bedside washing of stored RBCs.Materials and Methods: Stored RBCs were diluted to 10% haematocrit (Hct) with normal saline, matching the conventional washing procedure. The dilute RBC suspensions were passed through a column of coiled tubing to allow RBC sedimentation in normal gravity, thus separating them from the washing solution. Washed RBCs were collected using bifurcations located along the tubing. Washing efficiency was quantified by measuring Hct, morphology, deformability, free haemoglobin and total‐free protein.Results: The gravity‐driven washing system operating at 0·5 ml/min produced washed RBCs with final Hct of 36·7 ± 3·4% (32·3–41·2%, n = 10) and waste Hct of 3·4 ± 0·7% (2·4–4·3%, n = 10), while removing 80% of free haemoglobin and 90% of total‐free protein. Washing improved the ability of stored RBCs to perfuse an artificial microvascular network by 20%. The efficiency of washing performed using the gravity‐driven system was not significantly different than that of conventional centrifugation.Conclusions: This proof‐of‐concept study demonstrates the feasibility of washing stored RBCs using a simple, disposable system with efficiency comparable to that of conventional centrifugation, and thus represents a significant first step towards enabling low‐cost washing of stored blood at bedside.


  • Washing in hypotonic saline reduces the fraction of irreversibly-damaged cells in stored blood: a proof-of-concept study

    by Hui Xia, Grishma Khanal, Briony C Strachan, Eszter Vörös, Nathaniel Z Piety, Sean C Gifford, Sergey S Shevkoplyas

    During hypothermic storage, a substantial fraction of red blood cells (RBCs) transforms from flexible discocytes to rigid sphero-echinocytes and spherocytes. Infusion of these irreversibly-damaged cells into the recipient during transfusion serves no therapeutic purpose and may contribute to adverse outcomes in some patients. In this proof-of-concept study we describe the use of hypotonic washing for selective removal of the irreversibly-damaged cells from stored blood.Stored RBCs were mixed with saline of various concentrations to identify optimal concentration for inducing osmotic swelling and selective bursting of spherical cells (sphero-echinocytes, spherocytes), while minimising indiscriminate lysis of other RBCs. Effectiveness of optimal treatment was assessed by measuring morphology, rheological properties, and surface phosphatidylserine (PS) exposure for cells from several RBCs units (n=5, CPD>AS-1, leucoreduced, 6 weeks storage duration) washed in hypotonic vs isotonic saline.Washing in mildly hypotonic saline (0.585 g/dL, osmolality: 221.7±2.3 mmol/kg) reduced the fraction of spherical cells 3-fold from 9.5±3.4% to 3.2±2.8%, while cutting PS exposure in half from 1.48±0.86% to 0.59±0.29%. Isotonic washing had no effect on PS exposure or the fraction of spherical cells. Both isotonic and hypotonic washing increased the fraction of well-preserved cells (discocytes, echinocytes 1) substantially, and improved the ability of stored RBCs to perfuse an artificial microvascular network by approximately 25%, as compared with the initial sample.This study demonstrated that washing in hypotonic saline could selectively remove a significant fraction of the spherical and PS-exposing cells from stored blood, while significantly improving the rheological properties of remaining well-preserved RBCs. Further studies are needed to access the potential effect from hypotonic washing on transfusion outcomes.


  • Open Access

    A high-throughput microfluidic approach for 1000-fold leukocyte reduction of platelet-rich plasma

    by Hui Xia, Briony C. Strachan, Sean C. Gifford, Sergey S. Shevkoplyas

    Leukocyte reduction of donated blood products substantially reduces the risk of a number of transfusion-related complications. Current ‘leukoreduction’ filters operate by trapping leukocytes within specialized filtration material, while allowing desired blood components to pass through. However, the continuous release of inflammatory cytokines from the retained leukocytes, as well as the potential for platelet activation and clogging, are significant drawbacks of conventional ‘dead end’ filtration. To address these limitations, here we demonstrate our newly-developed ‘controlled incremental filtration’ (CIF) approach to perform high-throughput microfluidic removal of leukocytes from platelet-rich plasma (PRP) in a continuous flow regime. Leukocytes are separated from platelets within the PRP by progressively syphoning clarified PRP away from the concentrated leukocyte flowstream. Filtrate PRP collected from an optimally-designed CIF device typically showed a ~1000-fold (i.e. 99.9%) reduction in leukocyte concentration, while recovering >80% of the original platelets, at volumetric throughputs of ~1 mL/min. These results suggest that the CIF approach will enable users in many fields to now apply the advantages of microfluidic devices to particle separation, even for applications requiring macroscale flowrates.


  • Microfluidic based immunosensor for detection and purification of carbonylated proteins

    by Hui Xia, Bobby Mathew, Tom John, Hisham Hegab, June Feng

    A microchip has been developed on the basis of immno-precipitation approach for fast and sensitive enrichment of low abundant carbonylated proteins. This microfluidic method could enrich molecular biomarkers, which could be further analyzed in the proteomic study of age-related diseases and therapeutic development. In this study, an immunoaffinity-based PDMS micro-device was designed, fabricated, and chemically modified to specifically trap DNP-labeled PTM proteins of low abundance from a complex protein mixture. Carbonylated protein is selected as a representative PTM protein to illustrate the wide application of this immuno-based microchip for other PTMs which could be readily labeled by different antibody groups. Surface characterization methods such as atomic force microscopy and fluorescence microscopy were used to evaluate the construction of glutaraldehyde- and antibody- terminated PDMS substrates in the device fabrication. Quantitative study was also applied to study the target protein capture and elution efficiency of the device. In a testing mixture consisting of smaller amount of test model—In Vitro oxidized cytochrome c and large blocking protein BSA, a high sensitivity and specificity for only carbonylated protein biomarkers was demonstrated using this on-chip immnuoaffinity based extraction/enrichment. For this highly dense 193-post arrays μ-chip, a low abundance of 159 ng of standard in vitro test model- cytochrome c was enriched at flow speed of 5 μL/min within 110 min. We demonstrated that this nascent micro-immunoprecipitation (μ-IP) method is capable for enrichment of biomarkers in protein post-translation modification related diseases and promise great advance in early disease detection.


  • Microfluidic Immunoprecipitation for Post-Translational Modified Protein Purification

    by Hui Xia, Bobby Mathew, Tom John, Hisham Hegab, June Feng

  • Simulation Based Optimization of Microfluidic Devices Used for Molecular Enrichment

    by Hui Xia, Bobby Mathew, Hisham Hegab, June Feng

    Microfluidic devices are used in several engineering fields ranging from biomedical to chemical to engineering for applications such as micro reactor, target molecular enriching and cell capturing. With regard to related applications, microfluidic devices offer advantages such as high surface area to volume ratio, increased mass transfer coefficient and portability in addition to their requirement of low analytes. Affinity based microfluidic devices with microscale posts have high compactness and mass transfer coefficient. In order to maximize the benefits offered by employing microfluidic devices, it is important to apply parametric study in the device designing work. This study is aimed at studying the operating and geometric parameters of microfluidic devices with square/rectangular microscale posts. The geometric parameters, such as aspect ratio of the microposts used, could possibly decide the performance of the device. Operating parameters studied are Reynolds number, Peclet number, Damköhler number, and equilibrium reaction constant. These parameters encompass the influence of velocity, diffusivity, density, viscosity, hydraulic diameter, inlet concentration of species and absorption/desorption reaction constants. This work theoretically analyzes the influence of the above mentioned parameters using COMSOL Multiphysics 4.2.a. The governing equations of microfluidic devices, i.e. Navier-Stokes equations and the advection-diffusion equation, subjected to the above mentioned operating parameters, are solved to obtain the velocity profile, pressure drop and concentration profile of the species. The metric used for analyzing the influence of each operating parameter is the capture efficiency, i.e. the ratio of outlet concentration to inlet concentration as well the pressure drop. The results of this study would improve the design of microfluidic devices used for chemical reactions as well as that used for protein enrichment.


  • Ultra sensitive affinity chromatography on avidin-functionalized PMMA microchip for low abundant post-translational modified protein enrichment

    by Hui Xia, Kermit Murray, Steven Soper, June Feng

    Post-translational modifications (PTM) of proteins play essential roles in cellular physiology and disease. The identification of protein substrates and detection of modification site helps understand PTM-mediated regulation in essential biological pathways and functions in various diseases. However, PTM proteins are typically present only at trace levels, making them difficult to identify in mass spectrometry based proteomics. In this paper, we report a novel and sensitive affinity chromatography on the avidin-functionalized poly(methyl methacrylate) (PMMA) microchip for enrichment of nanogram (ng) amount of PTMs. The chemical modification of poly(methyl methacrylate) (PMMA) surfaces yield avidin-terminated PMMA surfaces after UV radiation and consecutive EDC mediated coupling (amide reaction). This functionalized PMMA micro-device was developed to identify and specifically trap biotinylated PTM proteins of low abundance from complex protein mixture. Here we selected carbonylated protein as a representative PTM to illustrate the wide application of this affinity microchip for any PTMs converted into a tractable tag after derivatization. The surface topography, surface functional group mapping and elemental composition changes after each modification step of the treatment process were systematically measured qualitatively and quantitatively by atomic force microscopy, X-ray photoelectron spectroscopy and fluorescence microscopy. Quantitative study of biotinlated carbonylated protein capture recovery and elution efficiency of the device was also studied. We also envision that this subproteome enrichment micro-device can be assembled with other lab-on-a-chip components for follow-up protein analysis.