Faycal Kharfi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Faycal Kharfi has a total of 63 co-authors. Here are the top co-authors by number of shared publications:
A. Boucenna
Department of Physics, Faculty of Science, University of Setif, Algeria
5 shared publications- Karim Benkahila3 shared publications
Abderrahim Betka
2 shared publicationsFouad Boulakhssaim
Department of Radiotherapy, Fighting against Cancer Medical Centre, Sétif, Algeria
2 shared publicationsKarim Benkahila
Laboratory of Dosing, Analysis and Characterization with High Resolution, Setif1 University-Ferhat Abbas, Setif, Algeria
2 shared publicationsM. Hachouf
2 shared publications
Latest Publications
- Open Access
- 23 September 2026
- Published by AccScience Publishing in Advances in Radiotherapy & Nuclear Medicine
- Vol. 4 (3) , 026270031
Design, characterization, and fabrication of a 3D-printed patient-specific and personalized cranial immobilization system for radiotherapy treatment
Accurate immobilization is essential in cranial radiotherapy because modern treatment techniques rely on high geometric precision and tight setup tolerances. Conventional thermoplastic masks remain the clinical standard, but they may be uncomfortable, anxiety-provoking, and insufficiently adapted to individual facial anatomy. This study investigates the design, fabrication, and preclinical validation of a personalized immobilization system composed of a facial shell and fixation belts. The necessary facial surface was acquired using an EinScan Pro+ scanner. The facial shell was designed in Meshmixer, while the fixation belts and hooks were modeled in Fusion 360 according to the geometry of a Klarity Optek™ indexing board. Final components were sliced in Cura and fabricated on an Artillery Sidewinder X1 printer. Polylactic acid (PLA) and thermoplastic polyurethane (TPU) were numerically evaluated in COMSOL Multiphysics 6.3 for thermal phase transition during printing, irradiation-induced heating under a 6 MV radiotherapy photon beam (400 MU/min for 15 min), and tensile mechanical behavior of the fixation belts. The workflow successfully produced a 2.5-mm-thick patient-specific immobilization device with excellent anatomical conformity and compatibility with the clinical support system. Simulated peak temperatures remained low for both PLA (27.85 °C) and TPU (28.45 °C), indicating thermal stability during photon irradiation. Mechanical simulations showed peak stress of approximately 0.7 MPa and maximum displacement (deformation) of 0.012 mm for PLA and 0.4 mm for TPU, both below a 1-mm tolerance threshold. The proposed workflow supports the feasibility of personalized 3D-printed cranial immobilization devices, with TPU emerging as a promising material because it combines structural stability with greater flexibility and patient comfort.
- 23 September 2026
- Published by AccScience Publishing in Advances in Radiotherapy & Nuclear Medicine
- Vol. 4 (3) , 026270031
Open AccessDesign, characterization, and fabrication of a 3D-printed patient-specific and personalized cranial immobilization system for radiotherapy treatment
Accurate immobilization is essential in cranial radiotherapy because modern treatment techniques rely on high geometric precision and tight setup tolerances. Conventional thermoplastic masks remain the clinical standard, but they may be uncomfortable, anxiety-provoking, and insufficiently adapted to individual facial anatomy. This study investigates the design, fabrication, and preclinical validation of a personalized immobilization system composed of a facial shell and fixation belts. The necessary facial surface was acquired using an EinScan Pro+ scanner. The facial shell was designed in Meshmixer, while the fixation belts and hooks were modeled in Fusion 360 according to the geometry of a Klarity Optek™ indexing board. Final components were sliced in Cura and fabricated on an Artillery Sidewinder X1 printer. Polylactic acid (PLA) and thermoplastic polyurethane (TPU) were numerically evaluated in COMSOL Multiphysics 6.3 for thermal phase transition during printing, irradiation-induced heating under a 6 MV radiotherapy photon beam (400 MU/min for 15 min), and tensile mechanical behavior of the fixation belts. The workflow successfully produced a 2.5-mm-thick patient-specific immobilization device with excellent anatomical conformity and compatibility with the clinical support system. Simulated peak temperatures remained low for both PLA (27.85 °C) and TPU (28.45 °C), indicating thermal stability during photon irradiation. Mechanical simulations showed peak stress of approximately 0.7 MPa and maximum displacement (deformation) of 0.012 mm for PLA and 0.4 mm for TPU, both below a 1-mm tolerance threshold. The proposed workflow supports the feasibility of personalized 3D-printed cranial immobilization devices, with TPU emerging as a promising material because it combines structural stability with greater flexibility and patient comfort.
- Open Access
- 16 October 2025
- Published by AccScience Publishing in Advances in Radiotherapy & Nuclear Medicine
- Vol. 3 (4) , 38
3D-printed personalized bolus designed through structured-light scanning for adaptive radiotherapy
Conformal dose delivery in external beam radiotherapy often requires a tissue‐equivalent bolus to compensate for surface irregularities and increase skin dose. However, traditional bolus fabrication methods are time‐consuming, imprecise, and poorly adaptable to patient anatomy. This study presents an alternative, innovative workflow that integrates three-dimensional (3D) structured-light scanning (SLS), computer-aided design, and 3D printing to rapidly and accurately fabricate patient‐specific boluses. First, a chin bolus was generated within the treatment planning system using a Rando anthropomorphic phantom as a reference. The generated bolus was then processed, 3D-printed, and tested. To avoid additional computed tomography scans and unnecessary X-ray exposure, a high‐resolution, inoffensive SLS scanner was used to capture the treatment surface. The resulting point‐cloud data were imported into 3D modeling software to design a custom bolus geometry that conforms exactly to the patient’s skin contour. The workflow also incorporated a rapid rescanning and reprinting loop, enabling intra‐fractional and inter‐fractional modifications in response to anatomical changes. The 3D‐printed bolus demonstrated excellent conformity to the phantom surface. The entire process, from scanning to bolus deployment, was completed within a reasonable timeframe, substantially reducing patient waiting time compared with conventional methods. Overall, the proposed 3D printing-based workflow offers a rapid, accurate, and patient-specific alternative to conventional bolus fabrication. By leveraging SLS and digital modeling, this approach enhances conformity, improves dosimetric accuracy, and allows agile modifications to accommodate anatomical changes, thereby optimizing radiotherapy treatment delivery.
- 16 October 2025
- Published by AccScience Publishing in Advances in Radiotherapy & Nuclear Medicine
- Vol. 3 (4) , 38
Open Access3D-printed personalized bolus designed through structured-light scanning for adaptive radiotherapy
Conformal dose delivery in external beam radiotherapy often requires a tissue‐equivalent bolus to compensate for surface irregularities and increase skin dose. However, traditional bolus fabrication methods are time‐consuming, imprecise, and poorly adaptable to patient anatomy. This study presents an alternative, innovative workflow that integrates three-dimensional (3D) structured-light scanning (SLS), computer-aided design, and 3D printing to rapidly and accurately fabricate patient‐specific boluses. First, a chin bolus was generated within the treatment planning system using a Rando anthropomorphic phantom as a reference. The generated bolus was then processed, 3D-printed, and tested. To avoid additional computed tomography scans and unnecessary X-ray exposure, a high‐resolution, inoffensive SLS scanner was used to capture the treatment surface. The resulting point‐cloud data were imported into 3D modeling software to design a custom bolus geometry that conforms exactly to the patient’s skin contour. The workflow also incorporated a rapid rescanning and reprinting loop, enabling intra‐fractional and inter‐fractional modifications in response to anatomical changes. The 3D‐printed bolus demonstrated excellent conformity to the phantom surface. The entire process, from scanning to bolus deployment, was completed within a reasonable timeframe, substantially reducing patient waiting time compared with conventional methods. Overall, the proposed 3D printing-based workflow offers a rapid, accurate, and patient-specific alternative to conventional bolus fabrication. By leveraging SLS and digital modeling, this approach enhances conformity, improves dosimetric accuracy, and allows agile modifications to accommodate anatomical changes, thereby optimizing radiotherapy treatment delivery.
- Open Access
- 8 June 2025
- Published by Brieflands in International Journal of Cancer Management
- Vol. 18 (1)
Dosimetric Validation and Surface Fit Evaluation of 3D-Printed Dose Boluses for Radiation Therapy Applications
Background: In modern radiation therapy, accurate dose delivery to tumor sites while sparing surrounding healthy tissue is paramount. A dose bolus, commonly employed to modulate surface dose distribution, ensures effective treatment. Objectives: The present study focuses on the dosimetric validation of 3D-printed dose boluses by comparing their effective performances to the targeted ones when creating the virtual boluses by the clinician on the treatment planning system (TPS). Methods: The research involves the fabrication of 3D-printed boluses using flexible thermoplastic polyurethane filament (TPU) and the assessment of their dose delivery accuracy using “Eclipse” and “Monaco” TPS. By considering 3 treatment cases and clinical locations, namely: Frontal lobe, right breast and inguinal region, the validation process was based on the measurement and comparison of dose profiles across the air/bolus/tissue interfaces, dose coverage: D98%, D95%, D50%, D2% and Dmean, dose Homogeneity Index (HI), and dose Conformity Index (CI). How boluses fit the received surfaces was also checked through CT scanning. Results: The results demonstrate that 3D-printed boluses offer superior conformity to patient-specific anatomy, leading to improved surface dose distribution. Overall, the 3D-printed boluses exhibit optimal dosimetric performances that conform to the targeted ones, with the added benefits of customization and ease of production. Conclusions: This study highlights the potential of 3D printing technology to enhance radiation therapy by providing flexible, patient-specific solutions for the fabrication of dose bolus while maintaining the dosimetric integrity required for an effective and accurate treatment.
- 8 June 2025
- Published by Brieflands in International Journal of Cancer Management
- Vol. 18 (1)
Open AccessDosimetric Validation and Surface Fit Evaluation of 3D-Printed Dose Boluses for Radiation Therapy Applications
Background: In modern radiation therapy, accurate dose delivery to tumor sites while sparing surrounding healthy tissue is paramount. A dose bolus, commonly employed to modulate surface dose distribution, ensures effective treatment. Objectives: The present study focuses on the dosimetric validation of 3D-printed dose boluses by comparing their effective performances to the targeted ones when creating the virtual boluses by the clinician on the treatment planning system (TPS). Methods: The research involves the fabrication of 3D-printed boluses using flexible thermoplastic polyurethane filament (TPU) and the assessment of their dose delivery accuracy using “Eclipse” and “Monaco” TPS. By considering 3 treatment cases and clinical locations, namely: Frontal lobe, right breast and inguinal region, the validation process was based on the measurement and comparison of dose profiles across the air/bolus/tissue interfaces, dose coverage: D98%, D95%, D50%, D2% and Dmean, dose Homogeneity Index (HI), and dose Conformity Index (CI). How boluses fit the received surfaces was also checked through CT scanning. Results: The results demonstrate that 3D-printed boluses offer superior conformity to patient-specific anatomy, leading to improved surface dose distribution. Overall, the 3D-printed boluses exhibit optimal dosimetric performances that conform to the targeted ones, with the added benefits of customization and ease of production. Conclusions: This study highlights the potential of 3D printing technology to enhance radiation therapy by providing flexible, patient-specific solutions for the fabrication of dose bolus while maintaining the dosimetric integrity required for an effective and accurate treatment.
- Open Access
- 6 May 2025
- Published by AccScience Publishing in Advances in Radiotherapy & Nuclear Medicine
- Vol. 3 (2) , 61
Renal function reconstruction and modeling in dynamic scintigraphy
Dynamic renal scintigraphy is a key imaging technique for assessing renal function using time-activity curves (TACs), which represent radiotracer uptake and clearance. TAC accuracy depends on the region of interest (ROI) selection and the modeling approach used. This study aims to: (i) Reconstruct TACs manually using gray-level values in scintigraphic images and compare them to machine-generated TACs using key kinetic parameters (Tmax, T1/2, and the 30-min min/max ratio); and (ii) evaluate the effectiveness of a one-compartment empirical mathematical model for TAC fitting and its physiological relevance. Twelve clinical cases were analyzed, with TACs reconstructed manually using a rectangular ROI selection method and compared to those automatically generated by the scintigraphy machine. An empirical mathematical fitting function was developed to improve TAC fitting. Manually reconstructed TACs showed better dynamic behavior and physiological accuracy over machine-generated TACs, particularly due to differences in ROI selection and signal processing. Using gray-level values instead of raw radioactive counts enhanced the depiction of kidney dynamics. The proposed mathematical model demonstrated a strong correlation (R2 close to 1) and low error metrics, confirming its suitability for renal function assessment. While a free-hand ROI selection may improve accuracy, the rectangular method gives valuable results for the considered cases. This study highlights the importance of ROI selection in TAC reconstruction and demonstrates how manual methods and mathematical modeling can enhance renal functional assessment in clinical practice. Future work should validate these findings in larger datasets and assess the reproducibility of the proposed approach across different patient populations and imaging systems.
- 6 May 2025
- Published by AccScience Publishing in Advances in Radiotherapy & Nuclear Medicine
- Vol. 3 (2) , 61
Open AccessRenal function reconstruction and modeling in dynamic scintigraphy
Dynamic renal scintigraphy is a key imaging technique for assessing renal function using time-activity curves (TACs), which represent radiotracer uptake and clearance. TAC accuracy depends on the region of interest (ROI) selection and the modeling approach used. This study aims to: (i) Reconstruct TACs manually using gray-level values in scintigraphic images and compare them to machine-generated TACs using key kinetic parameters (Tmax, T1/2, and the 30-min min/max ratio); and (ii) evaluate the effectiveness of a one-compartment empirical mathematical model for TAC fitting and its physiological relevance. Twelve clinical cases were analyzed, with TACs reconstructed manually using a rectangular ROI selection method and compared to those automatically generated by the scintigraphy machine. An empirical mathematical fitting function was developed to improve TAC fitting. Manually reconstructed TACs showed better dynamic behavior and physiological accuracy over machine-generated TACs, particularly due to differences in ROI selection and signal processing. Using gray-level values instead of raw radioactive counts enhanced the depiction of kidney dynamics. The proposed mathematical model demonstrated a strong correlation (R2 close to 1) and low error metrics, confirming its suitability for renal function assessment. While a free-hand ROI selection may improve accuracy, the rectangular method gives valuable results for the considered cases. This study highlights the importance of ROI selection in TAC reconstruction and demonstrates how manual methods and mathematical modeling can enhance renal functional assessment in clinical practice. Future work should validate these findings in larger datasets and assess the reproducibility of the proposed approach across different patient populations and imaging systems.
- Open Access
- 1 October 2024
- Published by Apex Publishing in International Journal of Radiation Research
- Vol. 22 (4) , 1079-1083
Study of dose response, luminescence kinetics, and reading modes combination advantage of TLD-100H radiation dosimeter
Background: This study investigates various aspects of TLD-100H radiation dosimeter, including luminescence kinetics, dose response, and the effects of the combination of thermally stimulated (TL) and optically stimulated (OSL) luminescence modes. Materials and Methods: The TL kinetic parameters were determined using general order kinetics via computerized glow-curve deconvolution (GOK-CGCD). OSL ...
- 1 October 2024
- Published by Apex Publishing in International Journal of Radiation Research
- Vol. 22 (4) , 1079-1083
Open AccessStudy of dose response, luminescence kinetics, and reading modes combination advantage of TLD-100H radiation dosimeter
Background: This study investigates various aspects of TLD-100H radiation dosimeter, including luminescence kinetics, dose response, and the effects of the combination of thermally stimulated (TL) and optically stimulated (OSL) luminescence modes. Materials and Methods: The TL kinetic parameters were determined using general order kinetics via computerized glow-curve deconvolution (GOK-CGCD). OSL ...
- 1 May 2024
- Published by Wiley in Luminescence
- Vol. 39 (5) , e4755
Effect of IRSL‐BLSL‐TSL reading modes combination on thermoluminescence (TL) response of BeO dosimeter
The ultimate goal of this work is the study of the effect of luminescence stimulations and signals reading modes combinations on the thermoluminescence intensity and glow curve behaviour for the same X‐ray irradiation dose. Three interesting stimulating and reading modes are considered, namely, infrared stimulated luminescence (IRSL), blue light‐emitting diode stimulated luminescence (BLSL) and thermally stimulated luminescence (TSL). The studied stimulation and reading modes combination protocols are (Protocol 1) IRSL‐TSL, (Protocol 2) IRSL‐BLSL‐TSL and (Protocol 3) BLSL‐IRSL‐TSL. Experiments are performed on beryllium oxide (BeO) dosimeter. Results demonstrate well that the combination of reading modes have direct impact on the TL signal in terms of intensity and glow curve shape. It was also found that when reading modes are correctly combined, particularly when IRSL is applied first, then BLSL and TL, it is possible to collect two or more exploitable signals of different stimulation types for the same irradiation that can be used for different purposes and final applications.
- 1 May 2024
- Published by Wiley in Luminescence
- Vol. 39 (5) , e4755
Effect of IRSL‐BLSL‐TSL reading modes combination on thermoluminescence (TL) response of BeO dosimeter
The ultimate goal of this work is the study of the effect of luminescence stimulations and signals reading modes combinations on the thermoluminescence intensity and glow curve behaviour for the same X‐ray irradiation dose. Three interesting stimulating and reading modes are considered, namely, infrared stimulated luminescence (IRSL), blue light‐emitting diode stimulated luminescence (BLSL) and thermally stimulated luminescence (TSL). The studied stimulation and reading modes combination protocols are (Protocol 1) IRSL‐TSL, (Protocol 2) IRSL‐BLSL‐TSL and (Protocol 3) BLSL‐IRSL‐TSL. Experiments are performed on beryllium oxide (BeO) dosimeter. Results demonstrate well that the combination of reading modes have direct impact on the TL signal in terms of intensity and glow curve shape. It was also found that when reading modes are correctly combined, particularly when IRSL is applied first, then BLSL and TL, it is possible to collect two or more exploitable signals of different stimulation types for the same irradiation that can be used for different purposes and final applications.
- Open Access
- 1 January 2024
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 23
Implementation of 3D Printing and Modeling Technologies for the Fabrication of Dose Boluses for External Radiotherapy at the CLCC of Sétif, Algeria
Objective: In external radiotherapy, dose boluses and compensators are used for treatment of irregular facial topography surfaces. In such cases, skewed isodose curves need to be addressed using a bolus that gives the deep dose distribution a shape adapted to the anatomical structures to be protected or irradiated. The combination of 3D modeling and printing technologies is a promising alternative to the conventional inaccurate and uncomfortable bolus fabrication technique. In this work, the proposed technologies will be used in the design and fabrication of high-performance and high-accuracy boluses that respond to the main constraints on metrology, adhesion to the patient's surface, comfort, and dose delivery. Methods: As a first phase in the implementation of the proposed solution, 3D printing materials, to be used in the fabrication of radiotherapy boluses, were selected and characterized to check how they respond to the required criteria on functionality, safety, and quality. Results: The obtained results show that among the studied materials, thermoplastic polyurethane (TPU) was found to be slightly more suitable than polylactic acid (PLA) for the fabrication of 3D printing boluses but for some kinds of treatments, PLA may be preferred despite its relative rigidity. Conclusion: In this work, procedures for dose bolus fabrication were proposed, and necessary data were obtained for some available 3D printing materials (TPU and PLA) that can be used for targeted applications. This achievement is a major step toward the final implementation of 3D modeling and printing technologies for the efficient fabrication of radiotherapy dose boluses.
- 1 January 2024
- Published by SAGE Publications in Technology in Cancer Research & Treatment
- Vol. 23
Open AccessImplementation of 3D Printing and Modeling Technologies for the Fabrication of Dose Boluses for External Radiotherapy at the CLCC of Sétif, Algeria
Objective: In external radiotherapy, dose boluses and compensators are used for treatment of irregular facial topography surfaces. In such cases, skewed isodose curves need to be addressed using a bolus that gives the deep dose distribution a shape adapted to the anatomical structures to be protected or irradiated. The combination of 3D modeling and printing technologies is a promising alternative to the conventional inaccurate and uncomfortable bolus fabrication technique. In this work, the proposed technologies will be used in the design and fabrication of high-performance and high-accuracy boluses that respond to the main constraints on metrology, adhesion to the patient's surface, comfort, and dose delivery. Methods: As a first phase in the implementation of the proposed solution, 3D printing materials, to be used in the fabrication of radiotherapy boluses, were selected and characterized to check how they respond to the required criteria on functionality, safety, and quality. Results: The obtained results show that among the studied materials, thermoplastic polyurethane (TPU) was found to be slightly more suitable than polylactic acid (PLA) for the fabrication of 3D printing boluses but for some kinds of treatments, PLA may be preferred despite its relative rigidity. Conclusion: In this work, procedures for dose bolus fabrication were proposed, and necessary data were obtained for some available 3D printing materials (TPU and PLA) that can be used for targeted applications. This achievement is a major step toward the final implementation of 3D modeling and printing technologies for the efficient fabrication of radiotherapy dose boluses.
- 31 March 2023
- Published by Springer Nature in Journal of Sol-Gel Science and Technology
- Vol. 106 (3) , 654-662
Elaboration and TL&OSL response study of 1% Sb-doped Al2O3 dosimeter for high-energy radiation detection and dosimetry
- 31 March 2023
- Published by Springer Nature in Journal of Sol-Gel Science and Technology
- Vol. 106 (3) , 654-662
Elaboration and TL&OSL response study of 1% Sb-doped Al2O3 dosimeter for high-energy radiation detection and dosimetry