Iuri Marinov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Iuri Marinov has a total of 341 co-authors. Here are the top co-authors by number of shared publications:
- Zdenka Gašová
Ustav hematologie a krevní transfuze, Praha
7 shared publications - Berta Otova
Institute of Biology and Medical Genetics, 1st Faculty of Medicine and General Teaching Hospital, Charles University, Prague, Czech Republic
5 shared publications - Ales Panczak
Cleft Centre, Plastic Surgery Clinic at Kralovske Vinohrady Hospital in Prague, Prague, Czech Republic
4 shared publications - Andrea Illingworth
Dahl‐Chase Diagnostic Services Bangor Maine USA
4 shared publications - Jan Stary
Department of Pediatric Hematology and Oncology, 2nd Faculty of Medicine, Charles University and University Hospital Motol, Prague, Czech Republic
4 shared publications - Kyra Michalova
Institute of Hematology and Blood Transfusion, Prague, Czech Republic
4 shared publications
Latest Publications
- 25 May 2022
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 44 (5) , 868-874
Validation of a single tube 3‐colour immature red blood cell screening assay for the detection and enumeration of small, medium and large paroxysmal nocturnal haemoglobinuria clones by flow cytometry
Introduction: The reliable diagnosis of paroxysmal nocturnal haemoglobinuria (PNH) by flow cytometry is based on mandatory analysis of the erythroid, neutrophilic and monocytic lineages. In this study, we have evaluated the performance characteristics of a recently published immature red blood cell (iRBC) assay as a potential screening test for PNH by flow cytometry.Methods: Intra‐ and inter‐assay imprecision were determined in five replicates of small, medium and large PNH iRBC clones. Analytical and functional sensitivity was assessed by performing spiking tests for five replicates. Thirty healthy donors and 441 PNH patients were tested for evaluation of clinical specificity, sensitivity, positive and negative predictive values.Results: Coefficients of variation (CV) for intra‐/inter‐assay imprecision analyses were 1.31/1.50, 3.19/2.61 and 3.99/1.58 for the big, medium and small clone sizes, respectively. Absolute values (100%) were found for both clinical specificity and sensitivity as well as for both positive and negative predictive values. The CV from 5 replicate results for 10 clustered events was 15.7%. The coefficient of determination (r2), Pearson's correlation coefficient (r) and Bland–Altman mean bias were 0.9436/0.9234/1.7 for PNH iRBC compared to PNH neutrophils and 0.9553/0.9387/2.1 for PNH iRBCs compared to PNH monocytes.Conclusion: Our results confirm very good performance characteristics, high analytical and functional sensitivity, absolute clinical specificity and sensitivity as well as favourable correlation between PNH iRBCs and both PNH neutrophils and monocytes, suggesting that this cost‐effective 3‐colour iRBC assay can be used as a reliable screening test for evaluation of small, medium and large PNH clones by flow cytometry.
- 25 May 2022
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 44 (5) , 868-874
Validation of a single tube 3‐colour immature red blood cell screening assay for the detection and enumeration of small, medium and large paroxysmal nocturnal haemoglobinuria clones by flow cytometry
Introduction: The reliable diagnosis of paroxysmal nocturnal haemoglobinuria (PNH) by flow cytometry is based on mandatory analysis of the erythroid, neutrophilic and monocytic lineages. In this study, we have evaluated the performance characteristics of a recently published immature red blood cell (iRBC) assay as a potential screening test for PNH by flow cytometry.Methods: Intra‐ and inter‐assay imprecision were determined in five replicates of small, medium and large PNH iRBC clones. Analytical and functional sensitivity was assessed by performing spiking tests for five replicates. Thirty healthy donors and 441 PNH patients were tested for evaluation of clinical specificity, sensitivity, positive and negative predictive values.Results: Coefficients of variation (CV) for intra‐/inter‐assay imprecision analyses were 1.31/1.50, 3.19/2.61 and 3.99/1.58 for the big, medium and small clone sizes, respectively. Absolute values (100%) were found for both clinical specificity and sensitivity as well as for both positive and negative predictive values. The CV from 5 replicate results for 10 clustered events was 15.7%. The coefficient of determination (r2), Pearson's correlation coefficient (r) and Bland–Altman mean bias were 0.9436/0.9234/1.7 for PNH iRBC compared to PNH neutrophils and 0.9553/0.9387/2.1 for PNH iRBCs compared to PNH monocytes.Conclusion: Our results confirm very good performance characteristics, high analytical and functional sensitivity, absolute clinical specificity and sensitivity as well as favourable correlation between PNH iRBCs and both PNH neutrophils and monocytes, suggesting that this cost‐effective 3‐colour iRBC assay can be used as a reliable screening test for evaluation of small, medium and large PNH clones by flow cytometry.
- Open Access
- 18 March 2020
- Published by Wiley in Cytometry Part B: Clinical Cytometry
- Vol. 98 (2) , 109-118
Issue Information
- 18 March 2020
- Published by Wiley in Cytometry Part B: Clinical Cytometry
- Vol. 98 (2) , 109-118
Open AccessIssue Information
- Open Access
- 27 June 2018
- Published by IntechOpen
Accurate and High Sensitivity Identification of PNH Clones by Flow Cytometry
Flow cytometry performs a key role in the diagnosis of paroxysmal nocturnal hemoglobinuria (PNH). Careful selection and validation of antibody conjugates have allowed the development of reagent cocktails suitable for the high sensitivity detection of PNH red blood cells (RBCs) and white blood cells (WBCs) in PNH and related diseases such as aplastic anemia (AA) and some subsets of myelodysplastic syndromes (MDS). A CD235a-FITC/CD59-PE assay was developed capable of detecting Type III PNH RBCs at a limit of quantification (LOQ) of 0.01% or better. While separate 4-color Fluorescent Aerolysin (FLAER), CD24, CD15 and CD45-based neutrophil and FLAER, CD14, CD64 and CD45-based monocyte assays were developed to detect PNH WBC phenotypes, 5-, 6- and 7-color assays have subsequently been developed for more modern cytometers equipped with five or more fluorescence detectors. For instrumentation with five detectors, a single tube 5-color FLAER, CD157, CD15, CD64 and CD45-based assay to simultaneously detect PNH neutrophils and monocytes has been developed. For instruments with six or more detectors and multiple lasers, a variety of 5-, 6- and 7-color assays have been developed using combinations of FLAER, CD24, CD14 and CD157. All WBC assays have a limit of quantification (LOQ) of 0.1% or better. Using these standardized approaches, results have demonstrated good intra- and inter-laboratory performance characteristics even in laboratories with little prior experience performing PNH testing.
- 27 June 2018
- Published by IntechOpen
Open AccessAccurate and High Sensitivity Identification of PNH Clones by Flow Cytometry
Flow cytometry performs a key role in the diagnosis of paroxysmal nocturnal hemoglobinuria (PNH). Careful selection and validation of antibody conjugates have allowed the development of reagent cocktails suitable for the high sensitivity detection of PNH red blood cells (RBCs) and white blood cells (WBCs) in PNH and related diseases such as aplastic anemia (AA) and some subsets of myelodysplastic syndromes (MDS). A CD235a-FITC/CD59-PE assay was developed capable of detecting Type III PNH RBCs at a limit of quantification (LOQ) of 0.01% or better. While separate 4-color Fluorescent Aerolysin (FLAER), CD24, CD15 and CD45-based neutrophil and FLAER, CD14, CD64 and CD45-based monocyte assays were developed to detect PNH WBC phenotypes, 5-, 6- and 7-color assays have subsequently been developed for more modern cytometers equipped with five or more fluorescence detectors. For instrumentation with five detectors, a single tube 5-color FLAER, CD157, CD15, CD64 and CD45-based assay to simultaneously detect PNH neutrophils and monocytes has been developed. For instruments with six or more detectors and multiple lasers, a variety of 5-, 6- and 7-color assays have been developed using combinations of FLAER, CD24, CD14 and CD157. All WBC assays have a limit of quantification (LOQ) of 0.1% or better. Using these standardized approaches, results have demonstrated good intra- and inter-laboratory performance characteristics even in laboratories with little prior experience performing PNH testing.
- Open Access
- 13 June 2016
- Published by Wiley in Cytometry Part B: Clinical Cytometry
- Vol. 94 (2) , 257-263
Performance Characteristics of a Non‐Fluorescent Aerolysin‐Based Paroxysmal Nocturnal Hemoglobinuria (PNH) Assay for Simultaneous Evaluation of PNH Neutrophils and PNH Monocytes by Flow Cytometry, Following Published PNH Guidelines
Background: CD157 has been recently reported as a useful glycosylphosphatidylinositol (GPI)‐linked marker for the detection of paroxysmal nocturnal hemoglobinuria (PNH) clones in patients with suspected paroxysmal nocturnal hemoglobinuria by flow cytometry as it targets both neutrophils and monocytes. The aim of this study is to test the feasibility of a non‐fluorescent aerolysin (FLAER) approach and propose an alternative for laboratories, where FLAER is not available.Methods: We validated a non‐FLAER‐based single‐tube, 6‐color assay targeting the GPI‐linked structures CD157, CD24, and CD14. We determined its performance characteristics on 20 PNH patient samples containing a variety of clone sizes and compared results with a previously validated FLAER‐based approach.Results: Coefficient of variation (CV) for intra‐/interassay precision analyses ranged from 0.1%/0.2% to 3.02%/7.58% for neutrophils and from 0.10%/0.3% to 5.39%/6.36% for monocytes. Coefficient of determination (r2) for linear regression analysis of PNH clones from 20 patients ranging from 0.06% to 99.7% was 0.99 in all cases, Wilcoxon ranks test showed no statistically significant differences (P > 0.05), Bland–Altman analysis demonstrated performance agreement with mean bias ranging from 0.06 to 0.2.Conclusion: Our results confirm very good performance characteristics for both intra‐ and interassay precision analyses, favorable correlation, and agreement between the FLAER and non‐FLAER‐based approaches, using the CD157 GPI marker. Our experience suggests that a rapid and cost‐effective simultaneous evaluation of PNH neutrophils and monocytes by flow cytometry without using FLAER is possible in areas where FLAER may not be widely available. © 2016 International Clinical Cytometry Society
- 13 June 2016
- Published by Wiley in Cytometry Part B: Clinical Cytometry
- Vol. 94 (2) , 257-263
Open AccessPerformance Characteristics of a Non‐Fluorescent Aerolysin‐Based Paroxysmal Nocturnal Hemoglobinuria (PNH) Assay for Simultaneous Evaluation of PNH Neutrophils and PNH Monocytes by Flow Cytometry, Following Published PNH Guidelines
Background: CD157 has been recently reported as a useful glycosylphosphatidylinositol (GPI)‐linked marker for the detection of paroxysmal nocturnal hemoglobinuria (PNH) clones in patients with suspected paroxysmal nocturnal hemoglobinuria by flow cytometry as it targets both neutrophils and monocytes. The aim of this study is to test the feasibility of a non‐fluorescent aerolysin (FLAER) approach and propose an alternative for laboratories, where FLAER is not available.Methods: We validated a non‐FLAER‐based single‐tube, 6‐color assay targeting the GPI‐linked structures CD157, CD24, and CD14. We determined its performance characteristics on 20 PNH patient samples containing a variety of clone sizes and compared results with a previously validated FLAER‐based approach.Results: Coefficient of variation (CV) for intra‐/interassay precision analyses ranged from 0.1%/0.2% to 3.02%/7.58% for neutrophils and from 0.10%/0.3% to 5.39%/6.36% for monocytes. Coefficient of determination (r2) for linear regression analysis of PNH clones from 20 patients ranging from 0.06% to 99.7% was 0.99 in all cases, Wilcoxon ranks test showed no statistically significant differences (P > 0.05), Bland–Altman analysis demonstrated performance agreement with mean bias ranging from 0.06 to 0.2.Conclusion: Our results confirm very good performance characteristics for both intra‐ and interassay precision analyses, favorable correlation, and agreement between the FLAER and non‐FLAER‐based approaches, using the CD157 GPI marker. Our experience suggests that a rapid and cost‐effective simultaneous evaluation of PNH neutrophils and monocytes by flow cytometry without using FLAER is possible in areas where FLAER may not be widely available. © 2016 International Clinical Cytometry Society
- Open Access
- 23 May 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (5) , e0155959
Interferon-α Revisited: Individualized Treatment Management Eased the Selective Pressure of Tyrosine Kinase Inhibitors on BCR-ABL1 Mutations Resulting in a Molecular Response in High-Risk CML Patients
Bone marrow transplantation or ponatinib treatment are currently recommended strategies for management of patients with chronic myeloid leukemia (CML) harboring the T315I mutation and compound or polyclonal mutations. However, in some individual cases, these treatment scenarios cannot be applied. We used an alternative treatment strategy with interferon-α (IFN-α) given solo, sequentially or together with TKI in a group of 6 cases of high risk CML patients, assuming that the TKI-independent mechanism of action may lead to mutant clone repression. IFN-α based individualized therapy decreases of T315I or compound mutations to undetectable levels as assessed by next-generation deep sequencing, which was associated with a molecular response in 4/6 patients. Based on the observed results from immune profiling, we assumed that the principal mechanism leading to the success of the treatment was the immune activation induced with dasatinib pre-treatment followed by restoration of immunological surveillance after application of IFN-α therapy. Moreover, we showed that sensitive measurement of mutated BCR-ABL1 transcript levels augments the safety of this individualized treatment strategy.
- 23 May 2016
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 11 (5) , e0155959
Open AccessInterferon-α Revisited: Individualized Treatment Management Eased the Selective Pressure of Tyrosine Kinase Inhibitors on BCR-ABL1 Mutations Resulting in a Molecular Response in High-Risk CML Patients
Bone marrow transplantation or ponatinib treatment are currently recommended strategies for management of patients with chronic myeloid leukemia (CML) harboring the T315I mutation and compound or polyclonal mutations. However, in some individual cases, these treatment scenarios cannot be applied. We used an alternative treatment strategy with interferon-α (IFN-α) given solo, sequentially or together with TKI in a group of 6 cases of high risk CML patients, assuming that the TKI-independent mechanism of action may lead to mutant clone repression. IFN-α based individualized therapy decreases of T315I or compound mutations to undetectable levels as assessed by next-generation deep sequencing, which was associated with a molecular response in 4/6 patients. Based on the observed results from immune profiling, we assumed that the principal mechanism leading to the success of the treatment was the immune activation induced with dasatinib pre-treatment followed by restoration of immunological surveillance after application of IFN-α therapy. Moreover, we showed that sensitive measurement of mutated BCR-ABL1 transcript levels augments the safety of this individualized treatment strategy.
- 14 July 2015
- Published by Wiley in Transfusion
- Vol. 55 (11) , 2616-2619
FY*A silencing by the GATA‐motif variant FY*A(−69C) in a Caucasian family
The c.1-67C variant polymorphism in a GATA motif of the FY promoter is known to result in erythroid-specific FY silencing, that is, in Fy(a-) and Fy(b-) phenotypes. A Caucasian donor presented with the very rare Fy(a-b-) phenotype and was further investigated. Genomic DNA was analyzed by sequencing to identify the cause of the Fy(a-b-) phenotype. Samples were collected from some of his relatives to establish a correlation between the serology and genotyping results. Red blood cells were analyzed by gel column agglutination and flow cytometry. Genomic DNA was analyzed on genotyping microarrays, by DNA sequencing and by allele-specific PCR. In the donor, a single-nucleotide polymorphism T>C within the GATA motif was found at Position c.1-69 of the FY promoter and shown to occur in the FY*A allele. His genotype was found to be FY*A(-69C), FY*BW.01. In six FY*A/FY*B heterozygous members of the family, a perfect correlation was found between the presence vs. absence of the FY*A(-69C) variant allele and a Fy(a-) vs. Fy(a+) phenotype. The location of the c.1-69C polymorphism in a GATA motif whose disruption is known to result in a Fy null phenotype, together with the perfect correlation between the presence of the FY*A(-69C) allele and the Fy(a-) phenotype support a cause-effect relationship between the two.
- 14 July 2015
- Published by Wiley in Transfusion
- Vol. 55 (11) , 2616-2619
FY*A silencing by the GATA‐motif variant FY*A(−69C) in a Caucasian family
The c.1-67C variant polymorphism in a GATA motif of the FY promoter is known to result in erythroid-specific FY silencing, that is, in Fy(a-) and Fy(b-) phenotypes. A Caucasian donor presented with the very rare Fy(a-b-) phenotype and was further investigated. Genomic DNA was analyzed by sequencing to identify the cause of the Fy(a-b-) phenotype. Samples were collected from some of his relatives to establish a correlation between the serology and genotyping results. Red blood cells were analyzed by gel column agglutination and flow cytometry. Genomic DNA was analyzed on genotyping microarrays, by DNA sequencing and by allele-specific PCR. In the donor, a single-nucleotide polymorphism T>C within the GATA motif was found at Position c.1-69 of the FY promoter and shown to occur in the FY*A allele. His genotype was found to be FY*A(-69C), FY*BW.01. In six FY*A/FY*B heterozygous members of the family, a perfect correlation was found between the presence vs. absence of the FY*A(-69C) variant allele and a Fy(a-) vs. Fy(a+) phenotype. The location of the c.1-69C polymorphism in a GATA motif whose disruption is known to result in a Fy null phenotype, together with the perfect correlation between the presence of the FY*A(-69C) allele and the Fy(a-) phenotype support a cause-effect relationship between the two.
- 22 June 2015
- Published by Wiley in European Journal of Haematology
- Vol. 96 (3) , 276-284
Early MRD response as a prognostic factor in adult patients with acute lymphoblastic leukemia
Objective: To evaluate the prognostic power of minimal residual disease (MRD) monitored by polymerase chain reaction at defined time points during early treatment in adult patients with acute lymphoblastic leukemia (ALL).Methods: Seventy‐one patients were treated according to the GMALL 07/2003 protocol and evaluated for MRD in bone marrow by specific clonal rearrangements of Ig/TCR in BCR‐ABL negative ALL or fusion gene transcript in BCR‐ABL positive ALL.Results: Three‐year overall survival (OS) was 94% in patients with BCR‐ABL negative ALL reaching complete molecular response (CMR) after the first course of chemotherapy (vs. 32% if MRD >10−4; P = 0.001). Patients with CMR prior to the start of consolidation chemotherapy at week 11 had 3‐yr OS 82% (vs. 18% if MRD >10−4; P = 0.001). Patients with BCR‐ABL positive ALL showed slower MRD dynamics. There was a trend to better OS in patients with ≥4 log reduction of BCR‐ABL transcript prior to HSCT (92% vs. 50%; P = 0.065). None of the patients with detectable MRD (both BCR‐ABL positive and negative) after HSCT survived 3 yr.Conclusion: Early MRD kinetics is an important tool for new prognostication models with direct clinical impact irrespective of standard prognostic factors in patients with BCR‐ABL negative ALL.
- 22 June 2015
- Published by Wiley in European Journal of Haematology
- Vol. 96 (3) , 276-284
Early MRD response as a prognostic factor in adult patients with acute lymphoblastic leukemia
Objective: To evaluate the prognostic power of minimal residual disease (MRD) monitored by polymerase chain reaction at defined time points during early treatment in adult patients with acute lymphoblastic leukemia (ALL).Methods: Seventy‐one patients were treated according to the GMALL 07/2003 protocol and evaluated for MRD in bone marrow by specific clonal rearrangements of Ig/TCR in BCR‐ABL negative ALL or fusion gene transcript in BCR‐ABL positive ALL.Results: Three‐year overall survival (OS) was 94% in patients with BCR‐ABL negative ALL reaching complete molecular response (CMR) after the first course of chemotherapy (vs. 32% if MRD >10−4; P = 0.001). Patients with CMR prior to the start of consolidation chemotherapy at week 11 had 3‐yr OS 82% (vs. 18% if MRD >10−4; P = 0.001). Patients with BCR‐ABL positive ALL showed slower MRD dynamics. There was a trend to better OS in patients with ≥4 log reduction of BCR‐ABL transcript prior to HSCT (92% vs. 50%; P = 0.065). None of the patients with detectable MRD (both BCR‐ABL positive and negative) after HSCT survived 3 yr.Conclusion: Early MRD kinetics is an important tool for new prognostication models with direct clinical impact irrespective of standard prognostic factors in patients with BCR‐ABL negative ALL.
- 25 June 2014
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 37 (2) , 231-237
Clinical relevance of CD157 for rapid and cost‐effective simultaneous evaluation of PNH granulocytes and monocytes by flow cytometry
CD157 has been reported as a potentially useful marker for paroxysmal nocturnal hemoglobinuria (PNH) testing by flow cytometry (FCM). We determined the performance characteristics of a CD157-based five-color assay and compared results from patient analysis with results obtained with a previously validated CD14/CD24-based six-color protocol. Coefficient of variation (CV) for intra-/interassay precision analysis of granulocytes ranged from 0.88/0.09% to 3.02/3.71% and from 0.20/0.08% to 8.83/4.04% for the five- and six-color protocol, respectively. For monocyte, CV ranged from 0.42/0.49% to 8.13/4.80% for the five-color protocol and from 0.28/0.70% to 5.41/3.19% for the six-color protocol within various PNH clones. Coefficient of determination (r(2) ) for linear regression analysis of PNH clones ranging from 0.3 to 99.8% was >0.99 in all cases, Wilcoxon ranks test showed no statistically significant differences (P > 0.05), and Bland-Altman analysis demonstrated agreement with mean bias ranging from -0.02 to 0.38. Our results confirm very good performance characteristics for both intra- and interassay precision analyses, excellent correlation, and agreement between approaches. In agreement with recently published data, our experience supports the clinical relevance of CD157 for a rapid and cost-effective simultaneous evaluation of PNH leukocytes by flow cytometry.
- 25 June 2014
- Published by Wiley in International Journal of Laboratory Hematology
- Vol. 37 (2) , 231-237
Clinical relevance of CD157 for rapid and cost‐effective simultaneous evaluation of PNH granulocytes and monocytes by flow cytometry
CD157 has been reported as a potentially useful marker for paroxysmal nocturnal hemoglobinuria (PNH) testing by flow cytometry (FCM). We determined the performance characteristics of a CD157-based five-color assay and compared results from patient analysis with results obtained with a previously validated CD14/CD24-based six-color protocol. Coefficient of variation (CV) for intra-/interassay precision analysis of granulocytes ranged from 0.88/0.09% to 3.02/3.71% and from 0.20/0.08% to 8.83/4.04% for the five- and six-color protocol, respectively. For monocyte, CV ranged from 0.42/0.49% to 8.13/4.80% for the five-color protocol and from 0.28/0.70% to 5.41/3.19% for the six-color protocol within various PNH clones. Coefficient of determination (r(2) ) for linear regression analysis of PNH clones ranging from 0.3 to 99.8% was >0.99 in all cases, Wilcoxon ranks test showed no statistically significant differences (P > 0.05), and Bland-Altman analysis demonstrated agreement with mean bias ranging from -0.02 to 0.38. Our results confirm very good performance characteristics for both intra- and interassay precision analyses, excellent correlation, and agreement between approaches. In agreement with recently published data, our experience supports the clinical relevance of CD157 for a rapid and cost-effective simultaneous evaluation of PNH leukocytes by flow cytometry.
- 1 January 2014
- Published by Clinical Laboratory Publications in Clinical Laboratory
- Vol. 60 (2)
Evaluation and comparison of different approaches for the detection of PNH clones by flow cytometry following the ICCS guidelines.
Comparison between consensual approaches for the detection of paroxysmal nocturnal hemoglobinuria (PNH) clones by flow cytometry (FCM) following the international clinical cytometry society (ICCS) guidelines has not been widely reported.
- 1 January 2014
- Published by Clinical Laboratory Publications in Clinical Laboratory
- Vol. 60 (2)
Evaluation and comparison of different approaches for the detection of PNH clones by flow cytometry following the ICCS guidelines.
Comparison between consensual approaches for the detection of paroxysmal nocturnal hemoglobinuria (PNH) clones by flow cytometry (FCM) following the international clinical cytometry society (ICCS) guidelines has not been widely reported.
- Open Access
- 1 July 2013
- Published by Wiley in Cytometry Part B: Clinical Cytometry
- Vol. 84B (4) , 229-236
Intra‐ and interlaboratory variability of paroxysmal nocturnal hemoglobinuria testing by flow cytometry following the 2012 Practical Guidelines for high‐sensitivity paroxysmal nocturnal hemoglobinuria testing
Background Sutherland et al. recently published the Practical Guidelines for high-sensitivity detection of paroxysmal nocturnal hemoglobinuria (PNH) clones by flow cytometry (FCM), containing concise protocols for PNH testing. Methods Using this approach, we studied the intra- and interlaboratory variability observed in a multicenter study in which fresh blood samples containing three clinically relevant PNH clone sizes within the granulocytic, monocytic, and red blood cell (RBC) populations were shipped to each participating center. Results Coefficients of variation (CVs) for precision/reproducibility analysis ranged from 0.01%/0.02% to 0.48%/0.45% (big clone), from 0.69%/1.52% to 4.24%/5.80% (small-intermediate clone), from 1.47%/3.91% to 15.01% /17.83% (minor clone) for PNH white blood cells (WBCs) and from 0.24%/0.48% to 1.76%/1.83% (big clone), from 0.80%/1.14% to 2.39%/4.45% (small-intermediate clone), from 1.09%/3.36% to 10.54%/10.23% (minor clone) for PNH RBCs, respectively. Linear regression analysis showed excellent performance correlation between centers (r > 0.99), Wilcoxon rank test revealed no statistically significant differences for PNH granulocytes, monocytes, and RBCs (P > 0.05%), Bland–Altman analysis demonstrated good performance agreement for all target PNH clones (mean bias ranging from −1.47 to 0.71). Conclusion Our results demonstrate very good intra- and interlaboratory performance characteristics for both precision and reproducibility analyses and excellent correlation and agreement between centers for all target PNH clone sizes. Our data confirm the reliability and robustness of the recently published Practical Guidelines approach for high sensitivity PNH testing by flow cytometry and suggest that such an approach represents an excellent basis for standardization of PNH testing by flow cytometry. © 2013 International Clinical Cytometry Society
- 1 July 2013
- Published by Wiley in Cytometry Part B: Clinical Cytometry
- Vol. 84B (4) , 229-236
Open AccessIntra‐ and interlaboratory variability of paroxysmal nocturnal hemoglobinuria testing by flow cytometry following the 2012 Practical Guidelines for high‐sensitivity paroxysmal nocturnal hemoglobinuria testing
Background Sutherland et al. recently published the Practical Guidelines for high-sensitivity detection of paroxysmal nocturnal hemoglobinuria (PNH) clones by flow cytometry (FCM), containing concise protocols for PNH testing. Methods Using this approach, we studied the intra- and interlaboratory variability observed in a multicenter study in which fresh blood samples containing three clinically relevant PNH clone sizes within the granulocytic, monocytic, and red blood cell (RBC) populations were shipped to each participating center. Results Coefficients of variation (CVs) for precision/reproducibility analysis ranged from 0.01%/0.02% to 0.48%/0.45% (big clone), from 0.69%/1.52% to 4.24%/5.80% (small-intermediate clone), from 1.47%/3.91% to 15.01% /17.83% (minor clone) for PNH white blood cells (WBCs) and from 0.24%/0.48% to 1.76%/1.83% (big clone), from 0.80%/1.14% to 2.39%/4.45% (small-intermediate clone), from 1.09%/3.36% to 10.54%/10.23% (minor clone) for PNH RBCs, respectively. Linear regression analysis showed excellent performance correlation between centers (r > 0.99), Wilcoxon rank test revealed no statistically significant differences for PNH granulocytes, monocytes, and RBCs (P > 0.05%), Bland–Altman analysis demonstrated good performance agreement for all target PNH clones (mean bias ranging from −1.47 to 0.71). Conclusion Our results demonstrate very good intra- and interlaboratory performance characteristics for both precision and reproducibility analyses and excellent correlation and agreement between centers for all target PNH clone sizes. Our data confirm the reliability and robustness of the recently published Practical Guidelines approach for high sensitivity PNH testing by flow cytometry and suggest that such an approach represents an excellent basis for standardization of PNH testing by flow cytometry. © 2013 International Clinical Cytometry Society