Tohru Ikegami
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Tohru Ikegami has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
Nobuo Tanaka
Department of Biomolecular Engineering , Kyoto Institute of Technology , Matsugasaki, Kyoto, Japan
12 shared publicationsKen Hosoya
Kyoto Institute of Technology
6 shared publicationsKanta Horie
Translational Science, Neurology Business Group, Eisai Co., Ltd. Tsukuba, Ibaraki, 300-2635, Japan; Department of Neurology, Washington University School of Medicine, St. Louis, MO, 63110, USA
5 shared publications- Michael Lämmerhofer
University of Tübingen, Tübingen, Germany
4 shared publications Ashin Taniguchi
Faculty of Molecular Chemistry and Engineering, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto 606-8585, Japan
3 shared publications- Hiroshi Kobayashi
Department of Polymer Science and Engineering, Kyoto Institute of Technology, Matsugasaki, Sakyo-ku, Kyoto 606-8585, Japan
3 shared publications
Latest Publications
- 13 September 2026
- Published by Wiley in Journal of Separation Science
- Vol. 49 (9) , e70520
Systematic Evaluation of Partition‐Dominated Retention in Hydrophilic Interaction Liquid Chromatography (HILIC) Under Varying Aqueous Components of the Mobile Phase: Revisiting the HILIC Column Test Scheme
The robustness of a test for characterizing hydrophilic interaction liquid chromatography (HILIC) columns against variations in aqueous mobile‐phase composition was evaluated using mobile phases of acetonitrile/aqueous mixture (9:1, v/v) in the pH range of 3.6–6.8 of the aqueous part. Ten columns (commercially available and home‐made columns) were examined under five mobile phases differing in anion species (formate or acetate), NH 4 + concentration and salt concentration. The specific hydrophilicity of the columns was assessed via the retention factor of uridine ( k (U)), and the relative retention characteristics (i.e., retention selectivity: α ) were evaluated using structure‐related probe pairs. The k (U)‐values exhibited low variability under low‐salt conditions (20 mM in the aqueous part; CVs = 0.01–0.08), but higher variability under high‐salt conditions (100 mM in the aqueous part; CVs = 0.03–0.18). Under comparable pH conditions (ammonium formate at pH 4.5 vs. ammonium acetate at pH 4.7), k (U)‐values were consistently higher in the former, indicating that differences in NH 4 + concentration affect hydration at the stationary‐phase interface and thereby influence retention. This suggests that k (U), commonly used as an indicator of hydrophilic retention, can be affected significantly by partition interactions that are controlled by ionic concentration rather than the pH value of the mobile phase. In contrast, the characteristic α ‐values primarily associated with solute retention via partitioning exhibited high robustness (CVs ≤ 0.03). Notably, α ( k (U)/ k (2′‐deoxyuridine)) values correlated with the estimated phase ratio, suggesting that it reflects the effective volume of the hydrated layer on the surface of the packing materials. Furthermore, the relationships between α ( k (1‐β‐D‐arabinofuranosyl uracil)/ k (U)) and α ( k (vidarabine)/ k (adenosine)) indicated that nucleobase‑dependent interactions contribute significantly to stationary‑phase retention. Overall, these results demonstrate that each k (U) and α , particularly those associated with partition‐dominated retention, exhibit generally high robustness within this test framework and provide a basis for more robust and transferable HILIC column characterization.
- 13 September 2026
- Published by Wiley in Journal of Separation Science
- Vol. 49 (9) , e70520
Systematic Evaluation of Partition‐Dominated Retention in Hydrophilic Interaction Liquid Chromatography (HILIC) Under Varying Aqueous Components of the Mobile Phase: Revisiting the HILIC Column Test Scheme
The robustness of a test for characterizing hydrophilic interaction liquid chromatography (HILIC) columns against variations in aqueous mobile‐phase composition was evaluated using mobile phases of acetonitrile/aqueous mixture (9:1, v/v) in the pH range of 3.6–6.8 of the aqueous part. Ten columns (commercially available and home‐made columns) were examined under five mobile phases differing in anion species (formate or acetate), NH 4 + concentration and salt concentration. The specific hydrophilicity of the columns was assessed via the retention factor of uridine ( k (U)), and the relative retention characteristics (i.e., retention selectivity: α ) were evaluated using structure‐related probe pairs. The k (U)‐values exhibited low variability under low‐salt conditions (20 mM in the aqueous part; CVs = 0.01–0.08), but higher variability under high‐salt conditions (100 mM in the aqueous part; CVs = 0.03–0.18). Under comparable pH conditions (ammonium formate at pH 4.5 vs. ammonium acetate at pH 4.7), k (U)‐values were consistently higher in the former, indicating that differences in NH 4 + concentration affect hydration at the stationary‐phase interface and thereby influence retention. This suggests that k (U), commonly used as an indicator of hydrophilic retention, can be affected significantly by partition interactions that are controlled by ionic concentration rather than the pH value of the mobile phase. In contrast, the characteristic α ‐values primarily associated with solute retention via partitioning exhibited high robustness (CVs ≤ 0.03). Notably, α ( k (U)/ k (2′‐deoxyuridine)) values correlated with the estimated phase ratio, suggesting that it reflects the effective volume of the hydrated layer on the surface of the packing materials. Furthermore, the relationships between α ( k (1‐β‐D‐arabinofuranosyl uracil)/ k (U)) and α ( k (vidarabine)/ k (adenosine)) indicated that nucleobase‑dependent interactions contribute significantly to stationary‑phase retention. Overall, these results demonstrate that each k (U) and α , particularly those associated with partition‐dominated retention, exhibit generally high robustness within this test framework and provide a basis for more robust and transferable HILIC column characterization.
- Open Access
- 21 July 2023
- Published by Qeios Ltd
Review of: "Developing a Novel Solvent System to Separate Polar and Nonpolar Leaf Pigments of Copperleaf (Acalypha wilkesiana) Using Thin Layer Chromatography"
In the country of the reviewer, the content of this manuscript is an experiment conducted by high school or university students. As far as the reviewer searched, there were many examples of separation of phytopigments on paper or TLC, using a mixed s...
- 21 July 2023
- Published by Qeios Ltd
Open AccessReview of: "Developing a Novel Solvent System to Separate Polar and Nonpolar Leaf Pigments of Copperleaf (Acalypha wilkesiana) Using Thin Layer Chromatography"
In the country of the reviewer, the content of this manuscript is an experiment conducted by high school or university students. As far as the reviewer searched, there were many examples of separation of phytopigments on paper or TLC, using a mixed s...
- 1 August 2021
- Published by Elsevier in Journal of Chromatography A
- Vol. 1650, 462207
Comparison of the steric selectivity on hydrophilic interaction chromatography columns modified with poly(acrylamide) possessing different morphology
- 1 August 2021
- Published by Elsevier in Journal of Chromatography A
- Vol. 1650, 462207
Comparison of the steric selectivity on hydrophilic interaction chromatography columns modified with poly(acrylamide) possessing different morphology
- 1 September 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1627, 461430
A selective comprehensive reversed-phase×reversed-phase 2D-liquid chromatography approach with multiple complementary detectors as advanced generic method for the quality control of synthetic and therapeutic peptides
- 1 September 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1627, 461430
A selective comprehensive reversed-phase×reversed-phase 2D-liquid chromatography approach with multiple complementary detectors as advanced generic method for the quality control of synthetic and therapeutic peptides
- 1 June 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1620, 460981
Separation of carbohydrate isomers and anomers on poly-N-(1H-tetrazole-5-yl)-methacrylamide-bonded stationary phase by hydrophilic interaction chromatography as well as determination of anomer interconversion energy barriers
- 1 June 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1620, 460981
Separation of carbohydrate isomers and anomers on poly-N-(1H-tetrazole-5-yl)-methacrylamide-bonded stationary phase by hydrophilic interaction chromatography as well as determination of anomer interconversion energy barriers
- 1 January 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1609, 460500
Retention characteristics of poly(N-(1H-tetrazole-5-yl)-methacrylamide)-bonded stationary phase in hydrophilic interaction chromatography
- 1 January 2020
- Published by Elsevier in Journal of Chromatography A
- Vol. 1609, 460500
Retention characteristics of poly(N-(1H-tetrazole-5-yl)-methacrylamide)-bonded stationary phase in hydrophilic interaction chromatography