Annemie Adriaens
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Annemie Adriaens has a total of 86 co-authors. Here are the top co-authors by number of shared publications:
- Karolien De Wael
Antwerp Engineering, Photoelectrochemistry & Sensing (A-PECS), University of Antwerp, Groenenborgerlaan 171, 2020 Antwerp, Belgium
9 shared publications Mark Dowsett
Department of Physics, University of Warwick, Coventry CV4 7AL, UK
8 shared publicationsFreddy Adams
Department of Chemistry, University of Antwerp, Universiteitsplein 1, B-2610 Antwerp, Belgium
4 shared publicationsLuc Van Vaeck
Department of Chemistry, University of Antwerp, Universiteitsplein 1, B-2610 Antwerp, Belgium
4 shared publicationsMichel De Keersmaecker
4 shared publicationsRita Van Ham
Department of Chemistry, University of Antwerp, Universiteitsplein 1, Antwerp, Belgium
4 shared publications
Latest Publications
- 1 November 2018
- Published by Elsevier in Materials & Design
- Vol. 157, 35-51
ANN prediction of corrosion behaviour of uncoated and biopolymers coated cp-Titanium substrates
- 1 November 2018
- Published by Elsevier in Materials & Design
- Vol. 157, 35-51
ANN prediction of corrosion behaviour of uncoated and biopolymers coated cp-Titanium substrates
- Open Access
The Use of a Saturated Long Carbon Chain Sodium Monocarboxylate for the Corrosion Inhibition of Lead Objects in Atmospheric Conditions and in Acetic Acid Corrosive Solutions
In this paper, a saturated long carbon chain sodium monocarboxylate containing 18 carbons—labeled NaC18—was used for the formation of a lead carboxylate coating to inhibit the corrosion of lead in atmospheric conditions and in acetic acid corrosive solutions. The effect of stirring of the coating solution during the coating process on the inhibition efficiency was studied. The coating was characterized by scanning electron microscopy and Fourier transform infrared spectroscopy which have confirmed a formation of lead carboxylate layer on the lead metal surface. The corrosion inhibition properties of the coating were tested using linear sweep voltammetry and electrochemical impedance spectroscopy in a solution simulating the atmospheric conditions and in an acetic acid corrosive solution. Results show that the lead carboxylate forms a protective barrier that inhibits corrosion of lead in atmospheric conditions and in acetic acid corrosive solutions.
Open AccessThe Use of a Saturated Long Carbon Chain Sodium Monocarboxylate for the Corrosion Inhibition of Lead Objects in Atmospheric Conditions and in Acetic Acid Corrosive Solutions
In this paper, a saturated long carbon chain sodium monocarboxylate containing 18 carbons—labeled NaC18—was used for the formation of a lead carboxylate coating to inhibit the corrosion of lead in atmospheric conditions and in acetic acid corrosive solutions. The effect of stirring of the coating solution during the coating process on the inhibition efficiency was studied. The coating was characterized by scanning electron microscopy and Fourier transform infrared spectroscopy which have confirmed a formation of lead carboxylate layer on the lead metal surface. The corrosion inhibition properties of the coating were tested using linear sweep voltammetry and electrochemical impedance spectroscopy in a solution simulating the atmospheric conditions and in an acetic acid corrosive solution. Results show that the lead carboxylate forms a protective barrier that inhibits corrosion of lead in atmospheric conditions and in acetic acid corrosive solutions.
- Open Access
- 25 April 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (5) , 133
A Multiplexed Microfluidic Platform for Bone Marker Measurement: A Proof-of-Concept
In this work, we report a microfluidic platform that can be easily translated into a biomarker diagnostic. This platform integrates microfluidic technology with electrochemical sensing and embodies a reaction/detection chamber to measure serum levels of different biomarkers. Microfabricated Au electrodes encased in a microfluidic chamber are functionalized to immobilize the antibodies, which can selectively capture the corresponding antigen. An oxidative peak is obtained using the chronoamperometry technique at room temperature. The magnitude of the response current varies linearly with the logarithmic concentration of the relative biomarker and, thus, is used to quantify the concentration of the relative biomarker in serum samples. We demonstrated the implementation, feasibility and specificity of this platform (Osteokit) in assaying serum levels of bone turnover markers (BTMs) using osteocalcin (limits of detection (LOD) = 1.94 ng/mL) and collagen type 1 cross-linked C-telopeptide (CTX) (LOD = 1.39 pg/mL). To our knowledge, this is the first such device fabricated to measure BTMs. Our results also showed that the sensitivity of Osteokit is comparable with the current states of art, electrochemiluminescence (ECLIA).
- 25 April 2017
- Published by MDPI AG in Micromachines
- Vol. 8 (5) , 133
Open AccessA Multiplexed Microfluidic Platform for Bone Marker Measurement: A Proof-of-Concept
In this work, we report a microfluidic platform that can be easily translated into a biomarker diagnostic. This platform integrates microfluidic technology with electrochemical sensing and embodies a reaction/detection chamber to measure serum levels of different biomarkers. Microfabricated Au electrodes encased in a microfluidic chamber are functionalized to immobilize the antibodies, which can selectively capture the corresponding antigen. An oxidative peak is obtained using the chronoamperometry technique at room temperature. The magnitude of the response current varies linearly with the logarithmic concentration of the relative biomarker and, thus, is used to quantify the concentration of the relative biomarker in serum samples. We demonstrated the implementation, feasibility and specificity of this platform (Osteokit) in assaying serum levels of bone turnover markers (BTMs) using osteocalcin (limits of detection (LOD) = 1.94 ng/mL) and collagen type 1 cross-linked C-telopeptide (CTX) (LOD = 1.39 pg/mL). To our knowledge, this is the first such device fabricated to measure BTMs. Our results also showed that the sensitivity of Osteokit is comparable with the current states of art, electrochemiluminescence (ECLIA).
- 1 December 2016
- Published by Elsevier in Progress in Organic Coatings
- Vol. 101, 225-232
Inhibition of the corrosion of iron heritage objects after treatment with long-chain monocarboxylic acids in ethanolic solutions
- 1 December 2016
- Published by Elsevier in Progress in Organic Coatings
- Vol. 101, 225-232
Inhibition of the corrosion of iron heritage objects after treatment with long-chain monocarboxylic acids in ethanolic solutions
- Open Access
- 1 August 2016
- Published by Elsevier in Bioelectrochemistry
- Vol. 110, 41-45
SR-XRD in situ monitoring of copper-IUD corrosion in simulated uterine fluid using a portable spectroelectrochemical cell
- 1 August 2016
- Published by Elsevier in Bioelectrochemistry
- Vol. 110, 41-45
Open AccessSR-XRD in situ monitoring of copper-IUD corrosion in simulated uterine fluid using a portable spectroelectrochemical cell
- 25 January 2016
- Published by Wiley in Materials and Corrosion
- Vol. 67 (7) , 693-701
Self‐healing silane coatings of cerium salt activated nanoparticles
This work investigates the effect of cerium salt activated nanoparticles as nanoreservoirs on the self‐healing properties of silane hybrid coatings deposited on electro‐galvanized steel substrates. The substrates were pre‐treated with 3–glycidoxypropyl‐trimethoxysilane (GPTMS) and bisphenol A (BPA), modified with cerium ion‐activated CeO2‐ZrO2 and CeO2‐SiO2 nanoparticles. The morphology of the coating before corrosion tests was examined using atomic force microscopy (AFM). The results indicate the formation of nanostructured surfaces with relatively uniform dispersion of nanoparticles in the silane coating containing CeO2‐ZrO2 nanoparticles. The corrosion behavior of the sol‐gel coatings was also investigated using salt spray tests, electrochemical impedance spectroscopy (EIS), and potentiodynamic polarization tests. During the salt spray test, the samples are exposed 600 h (or 25 days), revealing the improved resistance of the coated substrate containing CeO2‐ZrO2 nanoparticles. Incorporation of activated CeO2‐ZrO2 nanoparticles reduces the cathodic and anodic current density by one order of magnitude and shifts the corrosion potential to more positive values compared with the coating containing CeO2‐SiO2 nanoparticles. Also, the EIS test results revealed higher impedance for the coating containing activated CeO2‐ZrO2 nanoparticles. Corrosion tests results suggest that the activated CeO2‐ZrO2 nanoparticles are more effective as nano‐structured cerium ion reservoirs and can provide prolonged release of the inhibitor ions.
- 25 January 2016
- Published by Wiley in Materials and Corrosion
- Vol. 67 (7) , 693-701
Self‐healing silane coatings of cerium salt activated nanoparticles
This work investigates the effect of cerium salt activated nanoparticles as nanoreservoirs on the self‐healing properties of silane hybrid coatings deposited on electro‐galvanized steel substrates. The substrates were pre‐treated with 3–glycidoxypropyl‐trimethoxysilane (GPTMS) and bisphenol A (BPA), modified with cerium ion‐activated CeO2‐ZrO2 and CeO2‐SiO2 nanoparticles. The morphology of the coating before corrosion tests was examined using atomic force microscopy (AFM). The results indicate the formation of nanostructured surfaces with relatively uniform dispersion of nanoparticles in the silane coating containing CeO2‐ZrO2 nanoparticles. The corrosion behavior of the sol‐gel coatings was also investigated using salt spray tests, electrochemical impedance spectroscopy (EIS), and potentiodynamic polarization tests. During the salt spray test, the samples are exposed 600 h (or 25 days), revealing the improved resistance of the coated substrate containing CeO2‐ZrO2 nanoparticles. Incorporation of activated CeO2‐ZrO2 nanoparticles reduces the cathodic and anodic current density by one order of magnitude and shifts the corrosion potential to more positive values compared with the coating containing CeO2‐SiO2 nanoparticles. Also, the EIS test results revealed higher impedance for the coating containing activated CeO2‐ZrO2 nanoparticles. Corrosion tests results suggest that the activated CeO2‐ZrO2 nanoparticles are more effective as nano‐structured cerium ion reservoirs and can provide prolonged release of the inhibitor ions.
- Open Access
Corrosion of Bronzes by Extended Wetting with Single versus Mixed Acidic Pollutants
The corrosion of bronzes was examined in the context of single-acid versus mixed-acid (as in urban acid rain) solutions. Two bi-component bronzes (copper with either 3% Sn or 7% Sn) that closely represent those of historic artifacts were immersed for five weeks in conditions designed to replicate those experienced by statues and ornaments in cities where rainfall and humidity constantly produce an electrolyte layer on the surfaces of bronzes. Ions, acids, and particles of pollutants can dissolve in this layer, resulting in a variety of harsh corrosion processes. The kinetics of corrosion and the properties of the resulting patinas were monitored weekly by electrochemical impedance spectroscopy and open-circuit potential measurements. The sizes and appearances of the corrosion products were monitored and used to estimate the progress of the corrosion, whose crystalline structures were visualized using scanning electron microscopy with energy dispersive spectroscopy, identified by X-ray diffraction, and characterized by spectrocolorimetry. The electrochemical measurements demonstrated that greater damage (in terms of color change and corrosion product formation) did not correspond to deficiencies in protection. The mixed-acid solution did not corrode the bronzes, as would be expected from the additive effects of the single acids. The postulated mechanisms of metal dissolution appear to be specific to a particular bronze alloy, with the tin component playing an important role.
Open AccessCorrosion of Bronzes by Extended Wetting with Single versus Mixed Acidic Pollutants
The corrosion of bronzes was examined in the context of single-acid versus mixed-acid (as in urban acid rain) solutions. Two bi-component bronzes (copper with either 3% Sn or 7% Sn) that closely represent those of historic artifacts were immersed for five weeks in conditions designed to replicate those experienced by statues and ornaments in cities where rainfall and humidity constantly produce an electrolyte layer on the surfaces of bronzes. Ions, acids, and particles of pollutants can dissolve in this layer, resulting in a variety of harsh corrosion processes. The kinetics of corrosion and the properties of the resulting patinas were monitored weekly by electrochemical impedance spectroscopy and open-circuit potential measurements. The sizes and appearances of the corrosion products were monitored and used to estimate the progress of the corrosion, whose crystalline structures were visualized using scanning electron microscopy with energy dispersive spectroscopy, identified by X-ray diffraction, and characterized by spectrocolorimetry. The electrochemical measurements demonstrated that greater damage (in terms of color change and corrosion product formation) did not correspond to deficiencies in protection. The mixed-acid solution did not corrode the bronzes, as would be expected from the additive effects of the single acids. The postulated mechanisms of metal dissolution appear to be specific to a particular bronze alloy, with the tin component playing an important role.
- 13 March 2014
- Published by Springer Nature in Applied Physics A
- Vol. 118 (2) , 449-455
Electrochemical characterization of bronze historical objects using voltammetry of microparticles
- 13 March 2014
- Published by Springer Nature in Applied Physics A
- Vol. 118 (2) , 449-455
Electrochemical characterization of bronze historical objects using voltammetry of microparticles