Peter Cornelis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Peter Cornelis has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
- Patrick Wagner
Laboratory for Soft Matter and Biophysics, Department of Physics and Astronomy, KU Leuven, Celestijnenlaan 200 D, 3001 Leuven, Belgium
14 shared publications - Bart van Grinsven
Maastricht University
10 shared publications - Marloes Peeters
Department of Chemical Engineering, University of Manchester, Nancy Rothwell Building, Manchester, UK
8 shared publications - Kasper Eersels
Sensor Engineering Department, Faculty of Science and Engineering, Maastricht University, P.O. Box 616, Maastricht 6200 MD, The Netherlands
7 shared publications - Thomas Jan Cleij
Sensor Engineering Department, Faculty of Science and Engineering, Maastricht University, P.O. Box 616, Maastricht 6200 MD, The Netherlands
6 shared publications - Gideon Wackers
Laboratory for Soft Matter and Biophysics, KU Leuven, Celestijnenlaan 200D, Leuven B-3001, Belgium
5 shared publications
Latest Publications
- 1 June 2020
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 158, 112152
Towards a catheter-based impedimetric sensor for the assessment of intestinal histamine levels in IBS patients
- 1 June 2020
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 158, 112152
Towards a catheter-based impedimetric sensor for the assessment of intestinal histamine levels in IBS patients
- Open Access
- 17 January 2020
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 59 (SD) , SD0802
An imaging study and spectroscopic curing analysis on polymers for synthetic whole-cell receptors for bacterial detection
Surface imprinted polymers (SIPs) are versatile receptors in bioanalytical applications for the selective detection of cells and microorganisms such as bacteria. One of the synthesis routes is the so-called stamping method in which template bacteria are pressed mechanically into a thin, gel-like polyurethane layer, which is then cured in the presence of the templates to create cell-specific binding pockets on the polymer. The present work focusses on two specific steps of the imprinting protocol: first, we evaluate the sedimentation of two different groups of bacteria, Escherichia coli and Escherichia blattae , on silicone stamps with respect to the resulting surface coverage, which is a key factor for the efficiency of the imprinting process. Second, we analyse the temperature dependence of the thermal- and dielectric properties of polyurethane during curing by dielectric- and pyroelectric spectroscopy. This provides information for improved curing protocols and on the stability of SIP materials at elevated temperatures.
- 17 January 2020
- Published by IOP Publishing in Japanese Journal of Applied Physics
- Vol. 59 (SD) , SD0802
Open AccessAn imaging study and spectroscopic curing analysis on polymers for synthetic whole-cell receptors for bacterial detection
Surface imprinted polymers (SIPs) are versatile receptors in bioanalytical applications for the selective detection of cells and microorganisms such as bacteria. One of the synthesis routes is the so-called stamping method in which template bacteria are pressed mechanically into a thin, gel-like polyurethane layer, which is then cured in the presence of the templates to create cell-specific binding pockets on the polymer. The present work focusses on two specific steps of the imprinting protocol: first, we evaluate the sedimentation of two different groups of bacteria, Escherichia coli and Escherichia blattae , on silicone stamps with respect to the resulting surface coverage, which is a key factor for the efficiency of the imprinting process. Second, we analyse the temperature dependence of the thermal- and dielectric properties of polyurethane during curing by dielectric- and pyroelectric spectroscopy. This provides information for improved curing protocols and on the stability of SIP materials at elevated temperatures.
- Open Access
- 1 December 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (12) , 125106
A compact device for simultaneous dielectric spectroscopy and microgravimetric analysis under controlled humidity
Water plays a key role in the functioning of natural and synthetic molecular systems. Despite several hydration studies, different techniques are employed individually for monitoring different physical features such as kinetics, dynamics, and absorption. This study describes a compact hydration cell that enables simultaneous dielectric relaxation spectroscopy (DRS) and mass loss/uptake measurements in thin organic layers under controlled humidity conditions and in a wide temperature range. This approach enabled us to correlate the physical quantities obtained during the same experiment by complementary techniques. To demonstrate the performance of this device, a 200 nm thick poly(methyl methacrylate) (PMMA) layer was measured at various relative humidity levels (0%–75%), temperatures (25–75 °C), and frequencies (DRS: 0.1 Hz–1 MHz) to study how hydration and dehydration processes affect its molecular dynamics. The results show the capability of this setup to study the changes in the PMMA film regarding the kinetics and molecular dynamics upon variation of the water content.
- 1 December 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (12) , 125106
Open AccessA compact device for simultaneous dielectric spectroscopy and microgravimetric analysis under controlled humidity
Water plays a key role in the functioning of natural and synthetic molecular systems. Despite several hydration studies, different techniques are employed individually for monitoring different physical features such as kinetics, dynamics, and absorption. This study describes a compact hydration cell that enables simultaneous dielectric relaxation spectroscopy (DRS) and mass loss/uptake measurements in thin organic layers under controlled humidity conditions and in a wide temperature range. This approach enabled us to correlate the physical quantities obtained during the same experiment by complementary techniques. To demonstrate the performance of this device, a 200 nm thick poly(methyl methacrylate) (PMMA) layer was measured at various relative humidity levels (0%–75%), temperatures (25–75 °C), and frequencies (DRS: 0.1 Hz–1 MHz) to study how hydration and dehydration processes affect its molecular dynamics. The results show the capability of this setup to study the changes in the PMMA film regarding the kinetics and molecular dynamics upon variation of the water content.
- 1 July 2019
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 136, 97-105
Sensitive and specific detection of E. coli using biomimetic receptors in combination with a modified heat-transfer method
- 1 July 2019
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 136, 97-105
Sensitive and specific detection of E. coli using biomimetic receptors in combination with a modified heat-transfer method
- Open Access
A Novel Biomimetic Tool for Assessing Vitamin K Status Based on Molecularly Imprinted Polymers
Vitamin K was originally discovered as a cofactor required to activate clotting factors and has recently been shown to play a key role in the regulation of soft tissue calcification. This property of vitamin K has led to an increased interest in novel methods for accurate vitamin K detection. Molecularly Imprinted Polymers (MIPs) could offer a solution, as they have been used as synthetic receptors in a large variety of biomimetic sensors for the detection of similar molecules over the past few decades, because of their robust nature and remarkable selectivity. In this article, the authors introduce a novel imprinting approach to create a MIP that is able to selectively rebind vitamin K1. As the native structure of the vitamin does not allow for imprinting, an alternative imprinting strategy was developed, using the synthetic compound menadione (vitamin K3) as a template. Target rebinding was analyzed by means of UV-visible (UV-VIS) spectroscopy and two custom-made thermal readout techniques. This analysis reveals that the MIP-based sensor reacts to an increasing concentration of both menadione and vitamin K1. The Limit of Detection (LoD) for both compounds was established at 700 nM for the Heat Transfer Method (HTM), while the optimized readout approach, Thermal Wave Transport Analysis (TWTA), displayed an increased sensitivity with a LoD of 200 nM. The sensor seems to react to a lesser extent to Vitamin E, the analogue under study. To further demonstrate its potential application in biochemical research, the sensor was used to measure the absorption of vitamin K in blood serum after taking vitamin K supplements. By employing a gradual enrichment strategy, the sensor was able to detect the difference between baseline and peak absorption samples and was able to quantify the vitamin K concentration in good agreement with a validation experiment using High-Performance Liquid Chromatography (HPLC). In this way, the authors provide a first proof of principle for a low-cost, straightforward, and label-free vitamin K sensor.
Open AccessA Novel Biomimetic Tool for Assessing Vitamin K Status Based on Molecularly Imprinted Polymers
Vitamin K was originally discovered as a cofactor required to activate clotting factors and has recently been shown to play a key role in the regulation of soft tissue calcification. This property of vitamin K has led to an increased interest in novel methods for accurate vitamin K detection. Molecularly Imprinted Polymers (MIPs) could offer a solution, as they have been used as synthetic receptors in a large variety of biomimetic sensors for the detection of similar molecules over the past few decades, because of their robust nature and remarkable selectivity. In this article, the authors introduce a novel imprinting approach to create a MIP that is able to selectively rebind vitamin K1. As the native structure of the vitamin does not allow for imprinting, an alternative imprinting strategy was developed, using the synthetic compound menadione (vitamin K3) as a template. Target rebinding was analyzed by means of UV-visible (UV-VIS) spectroscopy and two custom-made thermal readout techniques. This analysis reveals that the MIP-based sensor reacts to an increasing concentration of both menadione and vitamin K1. The Limit of Detection (LoD) for both compounds was established at 700 nM for the Heat Transfer Method (HTM), while the optimized readout approach, Thermal Wave Transport Analysis (TWTA), displayed an increased sensitivity with a LoD of 200 nM. The sensor seems to react to a lesser extent to Vitamin E, the analogue under study. To further demonstrate its potential application in biochemical research, the sensor was used to measure the absorption of vitamin K in blood serum after taking vitamin K supplements. By employing a gradual enrichment strategy, the sensor was able to detect the difference between baseline and peak absorption samples and was able to quantify the vitamin K concentration in good agreement with a validation experiment using High-Performance Liquid Chromatography (HPLC). In this way, the authors provide a first proof of principle for a low-cost, straightforward, and label-free vitamin K sensor.
- 25 April 2018
- Published by Wiley in Physica Status Solidi (a)
- Vol. 215 (15)
A Novel Modular Device for Biological Impedance Measurements: The Differential Impedimetric Sensor Cell (DISC)
For medical diagnostics, food‐safety analysis, and detection of environmental pollutants, simultaneous detection and quantification of multiple target molecules can be a great advantage. Impedimetric measurements using molecularly imprinted polymers (MIPs), antibodies or aptamers as biomimetic sensors are becoming a well‐established technique for detecting, quantifying, and analyzing various biological targets such as DNA, proteins, and small molecules. The most commonly implemented systems use non‐Faradaic impedance spectroscopy. Adding a redox probe such as silver/silver chloride allows for the use of Faradaic impedance spectroscopy techniques using redox‐active molecules such as ferricyanide thereby extending the range of possible applications. Furthermore, the ability to perform differential measurements allows for the use of undiluted patient samples which significantly simplifies sample preparation. Therefore, adapting this low‐cost technique to simultaneously perform differential measurements on multiple targets and making it easy to use has great potential in a wide range of applications. In this work, a system that meets these requirements is successfully designed and fabricated. Up to eight different targets can be quasi‐simultaneously analyzed. Furthermore, the system is validated against a high‐resolution dielectric spectrometer (Novocontrol, Alpha analyzer) using well‐characterized samples at different temperatures over the whole frequency range (10 Hz–100 kHz).
- 25 April 2018
- Published by Wiley in Physica Status Solidi (a)
- Vol. 215 (15)
A Novel Modular Device for Biological Impedance Measurements: The Differential Impedimetric Sensor Cell (DISC)
For medical diagnostics, food‐safety analysis, and detection of environmental pollutants, simultaneous detection and quantification of multiple target molecules can be a great advantage. Impedimetric measurements using molecularly imprinted polymers (MIPs), antibodies or aptamers as biomimetic sensors are becoming a well‐established technique for detecting, quantifying, and analyzing various biological targets such as DNA, proteins, and small molecules. The most commonly implemented systems use non‐Faradaic impedance spectroscopy. Adding a redox probe such as silver/silver chloride allows for the use of Faradaic impedance spectroscopy techniques using redox‐active molecules such as ferricyanide thereby extending the range of possible applications. Furthermore, the ability to perform differential measurements allows for the use of undiluted patient samples which significantly simplifies sample preparation. Therefore, adapting this low‐cost technique to simultaneously perform differential measurements on multiple targets and making it easy to use has great potential in a wide range of applications. In this work, a system that meets these requirements is successfully designed and fabricated. Up to eight different targets can be quasi‐simultaneously analyzed. Furthermore, the system is validated against a high‐resolution dielectric spectrometer (Novocontrol, Alpha analyzer) using well‐characterized samples at different temperatures over the whole frequency range (10 Hz–100 kHz).
- 15 January 2018
- Published by Wiley in Physica Status Solidi (a)
- Vol. 215 (15)
SIP‐Based Thermal Detection Platform for the Direct Detection of Bacteria Obtained from a Contaminated Surface
Surface detection of bacteria has been proven difficult and time‐consuming. Different recovery techniques yield varying numbers of bacteria. Subsequently, bacterial culturing, used for identification of these bacteria, will take several hours. In this article, the potential of a newly developed thermal biomimetic sensor for the detection of bacteria on surfaces is described. Previously this thermal biomimetic sensor has proven to be able to detect and quantify different bacteria in various liquid media such as buffer and spiked urine samples. In this article, laboratory surfaces are contaminated with increasing concentrations of Escherichia coli. Bacteria are recovered from the surfaces using commercially available swab rinse kits (SRK). A calibration curve is created by coating chips with surface‐imprinted polymers (SIPs), serving as synthetic bacteria receptors, and exposing them to increasing concentrations of E. coli. Next, concentrations of E. coli in the SRK buffer are measured and quantified. The results show that it is possible to detect E. coli recovered from surfaces. Although quantification has been proven difficult as the dynamic range of the sensor is relatively narrow and the bacterial load obtained by using SRK is low, the sensor is able to give an indication about the concentration present on the surface. The results in this article illustrate that the thermal biomimetic sensor is a fast, low‐cost, and label‐free device useful in surface detection of E. coli, and seems a promising tool for future on‐site bacterial detection.
- 15 January 2018
- Published by Wiley in Physica Status Solidi (a)
- Vol. 215 (15)
SIP‐Based Thermal Detection Platform for the Direct Detection of Bacteria Obtained from a Contaminated Surface
Surface detection of bacteria has been proven difficult and time‐consuming. Different recovery techniques yield varying numbers of bacteria. Subsequently, bacterial culturing, used for identification of these bacteria, will take several hours. In this article, the potential of a newly developed thermal biomimetic sensor for the detection of bacteria on surfaces is described. Previously this thermal biomimetic sensor has proven to be able to detect and quantify different bacteria in various liquid media such as buffer and spiked urine samples. In this article, laboratory surfaces are contaminated with increasing concentrations of Escherichia coli. Bacteria are recovered from the surfaces using commercially available swab rinse kits (SRK). A calibration curve is created by coating chips with surface‐imprinted polymers (SIPs), serving as synthetic bacteria receptors, and exposing them to increasing concentrations of E. coli. Next, concentrations of E. coli in the SRK buffer are measured and quantified. The results show that it is possible to detect E. coli recovered from surfaces. Although quantification has been proven difficult as the dynamic range of the sensor is relatively narrow and the bacterial load obtained by using SRK is low, the sensor is able to give an indication about the concentration present on the surface. The results in this article illustrate that the thermal biomimetic sensor is a fast, low‐cost, and label‐free device useful in surface detection of E. coli, and seems a promising tool for future on‐site bacterial detection.
- Open Access
Single-Shot Detection of Neurotransmitters in Whole-Blood Samples by Means of the Heat-Transfer Method in Combination with Synthetic Receptors
Serotonin is an important neurotransmitter that plays a major role in the pathogenesis of a variety of conditions, including psychiatric disorders. The detection of serotonin typically relies on high-performance liquid chromatography (HPLC), an expensive technique that requires sophisticated equipment and trained personnel, and is not suitable for point-of-care applications. In this contribution, we introduce a novel sensor platform that can measure spiked neurotransmitter concentrations in whole blood samples in a fast and low-cost manner by combining synthetic receptors with a thermal readout technique—the heat-transfer method. In addition, the design of a miniaturized version of the sensing platform is presented that aims to bridge the gap between measurements in a laboratory setting and point-of-care measurements. This fully automated and integrated, user-friendly design features a capillary pumping unit that is compatible with point-of-care sampling techniques such as a blood lancet device (sample volume—between 50 µL and 300 µL). Sample pre-treatment is limited to the addition of an anti-coagulant. With this fully integrated setup, it is possible to successfully discriminate serotonin from a competitor neurotransmitter (histamine) in whole blood samples. This is the first demonstration of a point-of-care ready device based on synthetic receptors for the screening of neurotransmitters in complex matrices, illustrating the sensor’s potential application in clinical research and diagnosis of e.g., early stage depression.
Open AccessSingle-Shot Detection of Neurotransmitters in Whole-Blood Samples by Means of the Heat-Transfer Method in Combination with Synthetic Receptors
Serotonin is an important neurotransmitter that plays a major role in the pathogenesis of a variety of conditions, including psychiatric disorders. The detection of serotonin typically relies on high-performance liquid chromatography (HPLC), an expensive technique that requires sophisticated equipment and trained personnel, and is not suitable for point-of-care applications. In this contribution, we introduce a novel sensor platform that can measure spiked neurotransmitter concentrations in whole blood samples in a fast and low-cost manner by combining synthetic receptors with a thermal readout technique—the heat-transfer method. In addition, the design of a miniaturized version of the sensing platform is presented that aims to bridge the gap between measurements in a laboratory setting and point-of-care measurements. This fully automated and integrated, user-friendly design features a capillary pumping unit that is compatible with point-of-care sampling techniques such as a blood lancet device (sample volume—between 50 µL and 300 µL). Sample pre-treatment is limited to the addition of an anti-coagulant. With this fully integrated setup, it is possible to successfully discriminate serotonin from a competitor neurotransmitter (histamine) in whole blood samples. This is the first demonstration of a point-of-care ready device based on synthetic receptors for the screening of neurotransmitters in complex matrices, illustrating the sensor’s potential application in clinical research and diagnosis of e.g., early stage depression.
- Open Access
- 19 April 2017
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 2 (4) , 583-589
Label-Free Detection of Small Organic Molecules by Molecularly Imprinted Polymer Functionalized Thermocouples: Toward In Vivo Applications
Molecularly imprinted polymers (MIPs), synthetic polymeric receptors, have been combined successfully with thermal transducers for the detection of small molecules in recent years. However, up until now they have been combined with planar electrodes which limits their use for in vivo applications. In this work, a new biosensor platform is developed by roll-coating MIP particles onto thermocouples, functionalized with polylactic acid (PLLA). As a first proof-of-principle, MIPs for the neurotransmitter dopamine were incorporated into PLLA-coated thermocouples. The response of the synthetic receptor layer to an increasing concentration of dopamine in buffer was analyzed using a homemade heat-transfer setup. Binding of the template to the MIP layer blocks the heat transport through the thermocouple, leading to less heat loss to the environment and an overall higher temperature in the measuring chamber. The measured temperature increase is correlated to the neurotransmitter concentration, which enables measurement of dopamine levels in the micromolar regime. To demonstrate the general applicability of the proposed biosensor platform, thermocouples were functionalized with similar MIPs for cortisol and serotonin, indicating a similar response and limit-of-detection. As the platform does not require planar electrodes, it can easily be integrated in, e.g., a catheter. In this way, it is an excellent fit for the current niche in the market of therapeutics and diagnostics. Moreover, the use of a biocompatible and disposable PLLA-layer further illustrates its potential for in vivo diagnostics.
- 19 April 2017
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 2 (4) , 583-589
Open AccessLabel-Free Detection of Small Organic Molecules by Molecularly Imprinted Polymer Functionalized Thermocouples: Toward In Vivo Applications
Molecularly imprinted polymers (MIPs), synthetic polymeric receptors, have been combined successfully with thermal transducers for the detection of small molecules in recent years. However, up until now they have been combined with planar electrodes which limits their use for in vivo applications. In this work, a new biosensor platform is developed by roll-coating MIP particles onto thermocouples, functionalized with polylactic acid (PLLA). As a first proof-of-principle, MIPs for the neurotransmitter dopamine were incorporated into PLLA-coated thermocouples. The response of the synthetic receptor layer to an increasing concentration of dopamine in buffer was analyzed using a homemade heat-transfer setup. Binding of the template to the MIP layer blocks the heat transport through the thermocouple, leading to less heat loss to the environment and an overall higher temperature in the measuring chamber. The measured temperature increase is correlated to the neurotransmitter concentration, which enables measurement of dopamine levels in the micromolar regime. To demonstrate the general applicability of the proposed biosensor platform, thermocouples were functionalized with similar MIPs for cortisol and serotonin, indicating a similar response and limit-of-detection. As the platform does not require planar electrodes, it can easily be integrated in, e.g., a catheter. In this way, it is an excellent fit for the current niche in the market of therapeutics and diagnostics. Moreover, the use of a biocompatible and disposable PLLA-layer further illustrates its potential for in vivo diagnostics.