MJMorteza Jeyhani

Morteza Jeyhani

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Morteza Jeyhani has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • ATPSpin: A Single Microfluidic Platform that Produces Diversified ATPS-Alginate Microfibers

    by Niloofar Ghasemzaie, Morteza Jeyhani, Kushal Joshi, Warren L. Lee, Scott S. H. Tsai

    Microfluidic spinning is emerging as a useful technique in the fabrication of alginate fibers, enabling applications in drug screening, disease modeling, and disease diagnostics. In this paper, by capitalizing on the benefits of aqueous two-phase systems (ATPS) to produce diverse alginate fiber forms, we introduce an ATPS-Spinning platform (ATPSpin). This ATPS-enabled method efficiently circumvents the rapid clogging challenges inherent to traditional fiber production techniques by regulating the interaction between alginate and cross-linking agents like Ba2+ ions. By varying system parameters under the guidance of a regime map, our system produces several fiber forms─solid, hollow, and droplet-filled─consistently and reproducibly from a single device. We demonstrate that the resulting alginate fibers possess distinct features, including biocompatibility. We also encapsulate HEK293 cells in the microfibers as a proof-of-concept that this versatile microfluidic fiber generation platform may have utility in tissue engineering and regenerative medicine applications.


  • Microfluidically-generated Encapsulated Spheroids (μ-GELS): An All-Aqueous Droplet Microfluidics Platform for Multicellular Spheroids Generation

    by Jennifer Kieda, Sila Appak-Baskoy, Morteza Jeyhani, Maryam Navi, Katherine W. Y. Chan, Scott S. H. Tsai

    Spheroids are three-dimensional clusters of cells that serve as in vitro tumor models to recapitulate in vivo morphology. A limitation of many existing on-chip platforms for spheroid formation is the use of cytotoxic organic solvents as the continuous phase in droplet generation processes. All-aqueous methods do not contain cytotoxic organic solvents but have so far been unable to achieve complete hydrogel gelation on chip. Here, we describe an enhanced droplet microfluidic platform that achieves on-chip gelation of all-aqueous hydrogel multicellular spheroids (MCSs). Specifically, we generate dextran-alginate droplets containing MCF-7 breast cancer cells, surrounded by polyethylene glycol, at a flow-focusing junction. Droplets then travel to a second flow-focusing junction where they interact with calcium chloride and gel on chip to form hydrogel MCSs. On-chip gelation of the MCSs is possible here because of an embedded capillary at the second junction that delays the droplet gelation, which prevents channel clogging problems that would otherwise exist. In drug-free experiments, we demonstrate that MCSs remain viable for 6 days. We also confirm the applicability of this system for cancer drug testing by observing that dose-dependent cell death is achievable using doxorubicin.


  • Water-in-water droplet microfluidics: A design manual

    by Morteza Jeyhani, Maryam Navi, Katherine W. Y. Chan, Jennifer Kieda, Scott S. H. Tsai

    Droplet microfluidics is utilized in a wide range of applications in biomedicine and biology. Applications include rapid biochemical analysis, materials generation, biochemical assays, and point-of-care medicine. The integration of aqueous two-phase systems (ATPSs) into droplet microfluidic platforms has potential utility in oil-free biological and biomedical applications, namely, reducing cytotoxicity and preserving the native form and function of costly biomolecular reagents. In this review, we present a design manual for the chemist, biologist, and engineer to design experiments in the context of their biological applications using all-in-water droplet microfluidic systems. We describe the studies achievable using these systems and the corresponding fabrication and stabilization methods. With this information, readers may apply the fundamental principles and recent advancements in ATPS droplet microfluidics to their research. Finally, we propose a development roadmap of opportunities to utilize ATPS droplet microfluidics in applications that remain underexplored.


  • Evaporation-Driven Water-in-Water Droplet Formation

    by Byeong-Ui Moon, Lidija Malic, Keith Morton, Morteza Jeyhani, Abdelrahman Elmanzalawy, Scott S. H. Tsai, Teodor Veres

    We present new observations of aqueous two-phase system (ATPS) thermodynamic and interfacial phenomena that occur inside sessile droplets due to water evaporation. Sessile droplets that contain polymeric solutions, which are initially in equilibrium in a single phase, are observed at their three-phase liquid–solid–air contact line. As evaporation of a sessile droplet proceeds, we find that submicron secondary water-in-water (W/W) droplets emerge spontaneously at the edges of the mother sessile droplet due to the resulting phase separation from water evaporation. To understand this phenomenon, we first study the secondary W/W droplet formation process on different substrate materials, namely, glass, polycarbonate (PC), thermoplastic elastomer (TPE), poly(dimethylsiloxane)-coated glass slide (PDMS substrate), and Teflon-coated glass slide (Teflon substrate), and show that secondary W/W droplet formation arises only in lower-contact-angle substrates near the three-phase contact line. Next, we characterize the size of the emergent secondary W/W droplets as a function of time. We observe that W/W drops are formed, coalesced, aligned, and trapped along the contact line of the mother droplet. We demonstrate that this W/W multiple emulsion system can be used to encapsulate magnetic particles and blood cells, and achieve size-based separation. Finally, we show the applicability of this system for protein sensing. This is the first experimental observation of evaporation-induced secondary W/W droplet generation in a sessile droplet. We anticipate that the phenomena described here may be applicable to some biological assay applications, for example, biomarker detection, protein sensing, and point-of-care diagnostic testing.


  • 10.1063/5.0009443.3

    by Ehsan Azarsa, Morteza Jeyhani, Amro Ibrahim, Scott S. H. Tsai

    Microfluidic lab-on-a-chip devices are usually fabricated using replica molding, with poly(dimethylsiloxane) (PDMS) casting on a mold. Most common techniques used to fabricate microfluidic molds, such as photolithography and soft lithography, require costly facilities such as a cleanroom, and complicated steps, especially for the fabrication of three-dimensional (3D) features. For example, an often-desired 3D microchannel feature consists of intersecting channels with depth variations. This type of 3D flow focusing geometry has applications in flow cytometry and droplet generation. Various manufacturing techniques have recently been developed for the rapid fabrication of such 3D microfluidic features. In this paper, we describe a new method of mold fabrication that utilizes water jet cutting technology to fabricate free-standing structures on mild steel sheets to make a mold for PDMS casting. As a proof-of-concept, we use this fabrication technique to make a PDMS chip that has a 3D flow focusing junction, an inlet for the sample fluid, two inlets for the sheath fluid, and an outlet. The flow focusing junction is patterned into the PDMS slab with an abrupt, nearly stepwise change to the depth of the microchannel junction. We use confocal microscopy to visualize the 3D flow focusing of a sample flow using this geometry, and we also use the same geometry to generate water-in-oil droplets. This alternative approach to create microfluidic molds is versatile and may find utility in reducing the cost and complexity involved in fabricating 3D features in microfluidic devices.

  • 10.1063/5.0009443.2

    by Ehsan Azarsa, Morteza Jeyhani, Amro Ibrahim, Scott S. H. Tsai

    Microfluidic lab-on-a-chip devices are usually fabricated using replica molding, with poly(dimethylsiloxane) (PDMS) casting on a mold. Most common techniques used to fabricate microfluidic molds, such as photolithography and soft lithography, require costly facilities such as a cleanroom, and complicated steps, especially for the fabrication of three-dimensional (3D) features. For example, an often-desired 3D microchannel feature consists of intersecting channels with depth variations. This type of 3D flow focusing geometry has applications in flow cytometry and droplet generation. Various manufacturing techniques have recently been developed for the rapid fabrication of such 3D microfluidic features. In this paper, we describe a new method of mold fabrication that utilizes water jet cutting technology to fabricate free-standing structures on mild steel sheets to make a mold for PDMS casting. As a proof-of-concept, we use this fabrication technique to make a PDMS chip that has a 3D flow focusing junction, an inlet for the sample fluid, two inlets for the sheath fluid, and an outlet. The flow focusing junction is patterned into the PDMS slab with an abrupt, nearly stepwise change to the depth of the microchannel junction. We use confocal microscopy to visualize the 3D flow focusing of a sample flow using this geometry, and we also use the same geometry to generate water-in-oil droplets. This alternative approach to create microfluidic molds is versatile and may find utility in reducing the cost and complexity involved in fabricating 3D features in microfluidic devices.

  • 10.1063/5.0009443.1

    by Ehsan Azarsa, Morteza Jeyhani, Amro Ibrahim, Scott S. H. Tsai

    Microfluidic lab-on-a-chip devices are usually fabricated using replica molding, with poly(dimethylsiloxane) (PDMS) casting on a mold. Most common techniques used to fabricate microfluidic molds, such as photolithography and soft lithography, require costly facilities such as a cleanroom, and complicated steps, especially for the fabrication of three-dimensional (3D) features. For example, an often-desired 3D microchannel feature consists of intersecting channels with depth variations. This type of 3D flow focusing geometry has applications in flow cytometry and droplet generation. Various manufacturing techniques have recently been developed for the rapid fabrication of such 3D microfluidic features. In this paper, we describe a new method of mold fabrication that utilizes water jet cutting technology to fabricate free-standing structures on mild steel sheets to make a mold for PDMS casting. As a proof-of-concept, we use this fabrication technique to make a PDMS chip that has a 3D flow focusing junction, an inlet for the sample fluid, two inlets for the sheath fluid, and an outlet. The flow focusing junction is patterned into the PDMS slab with an abrupt, nearly stepwise change to the depth of the microchannel junction. We use confocal microscopy to visualize the 3D flow focusing of a sample flow using this geometry, and we also use the same geometry to generate water-in-oil droplets. This alternative approach to create microfluidic molds is versatile and may find utility in reducing the cost and complexity involved in fabricating 3D features in microfluidic devices.

  • 10.1063/5.0009443.4

    by Ehsan Azarsa, Morteza Jeyhani, Amro Ibrahim, Scott S. H. Tsai

    Microfluidic lab-on-a-chip devices are usually fabricated using replica molding, with poly(dimethylsiloxane) (PDMS) casting on a mold. Most common techniques used to fabricate microfluidic molds, such as photolithography and soft lithography, require costly facilities such as a cleanroom, and complicated steps, especially for the fabrication of three-dimensional (3D) features. For example, an often-desired 3D microchannel feature consists of intersecting channels with depth variations. This type of 3D flow focusing geometry has applications in flow cytometry and droplet generation. Various manufacturing techniques have recently been developed for the rapid fabrication of such 3D microfluidic features. In this paper, we describe a new method of mold fabrication that utilizes water jet cutting technology to fabricate free-standing structures on mild steel sheets to make a mold for PDMS casting. As a proof-of-concept, we use this fabrication technique to make a PDMS chip that has a 3D flow focusing junction, an inlet for the sample fluid, two inlets for the sheath fluid, and an outlet. The flow focusing junction is patterned into the PDMS slab with an abrupt, nearly stepwise change to the depth of the microchannel junction. We use confocal microscopy to visualize the 3D flow focusing of a sample flow using this geometry, and we also use the same geometry to generate water-in-oil droplets. This alternative approach to create microfluidic molds is versatile and may find utility in reducing the cost and complexity involved in fabricating 3D features in microfluidic devices.

  • A novel abrasive water jet machining technique for rapid fabrication of three-dimensional microfluidic components

    by Ehsan Azarsa, Morteza Jeyhani, Amro Ibrahim, Scott S. H. Tsai, Marcello Papini

    Microfluidic lab-on-a-chip devices are usually fabricated using replica molding, with poly(dimethylsiloxane) (PDMS) casting on a mold. Most common techniques used to fabricate microfluidic molds, such as photolithography and soft lithography, require costly facilities such as a cleanroom, and complicated steps, especially for the fabrication of three-dimensional (3D) features. For example, an often-desired 3D microchannel feature consists of intersecting channels with depth variations. This type of 3D flow focusing geometry has applications in flow cytometry and droplet generation. Various manufacturing techniques have recently been developed for the rapid fabrication of such 3D microfluidic features. In this paper, we describe a new method of mold fabrication that utilizes water jet cutting technology to fabricate free-standing structures on mild steel sheets to make a mold for PDMS casting. As a proof-of-concept, we use this fabrication technique to make a PDMS chip that has a 3D flow focusing junction, an inlet for the sample fluid, two inlets for the sheath fluid, and an outlet. The flow focusing junction is patterned into the PDMS slab with an abrupt, nearly stepwise change to the depth of the microchannel junction. We use confocal microscopy to visualize the 3D flow focusing of a sample flow using this geometry, and we also use the same geometry to generate water-in-oil droplets. This alternative approach to create microfluidic molds is versatile and may find utility in reducing the cost and complexity involved in fabricating 3D features in microfluidic devices.


  • Microfluidic Generation of All‐Aqueous Double and Triple Emulsions

    by Morteza Jeyhani, Risavarshni Thevakumaran, Niki Abbasi, Dae Kun Hwang, Scott S. H. Tsai

    Higher order emulsions are used in a variety of different applications in biomedicine, biological studies, cosmetics, and the food industry. Conventional droplet generation platforms for making higher order emulsions use organic solvents as the continuous phase, which is not biocompatible and as a result, further washing steps are required to remove the toxic continuous phase. Recently, droplet generation based on aqueous two‐phase systems (ATPS) has emerged in the field of droplet microfluidics due to their intrinsic biocompatibility. Here, a platform to generate all‐aqueous double and triple emulsions by introducing pressure‐driven flows inside a microfluidic hybrid device is presented. This system uses a conventional microfluidic flow‐focusing geometry coupled with a coaxial microneedle and a glass capillary embedded in flow‐focusing junctions. The configuration of the hybrid device enables the focusing of two coaxial two‐phase streams, which helps to avoid commonly observed channel‐wetting problems. It is shown that this approach achieves the fabrication of higher‐order emulsions in a poly(dimethylsiloxane)‐based microfluidic device, and controls the structure of the all‐aqueous emulsions. This hybrid microfluidic approach allows for facile higher‐order biocompatible emulsion formation, and it is anticipated that this platform will find utility for generating biocompatible materials for various biotechnological applications.