AWAte B. Wymenga

Ate B. Wymenga

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ate B. Wymenga has a total of 184 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Association between postoperative zonal fixation of hybrid tibial components in revision total knee arthroplasty and subsequent aseptic loosening

    by Simon N. van Laarhoven, Sjoerd P. F. T. Nota, Gijs G. van Hellemondt, Berend W. Schreurs, Ate B. Wymenga, Petra J. C. Heesterbeek

    Aims: Tibial fixation in revision total knee arthroplasty (rTKA) can present surgical challenges. It has been suggested that appropriate fixation in at least two of the three anatomical zones (epiphysis, metaphysis, and diaphysis) is essential for implant survival. However, supporting clinical data are lacking. In this retrospective case-control study, we investigated the relationship between zonal fixation of hybrid rTKA tibial components and re-revision total knee arthroplasty for aseptic loosening (rrTKA-AL).Methods: All consecutive rTKAs with hybrid tibial components (May 2006 to December 2020) were screened for subsequent rrTKA-AL. A control group was randomly selected from the remaining cohort. Postoperative radiographs of rTKAs were scored in random order by three blinded observers for zonal fixation in the epiphysis (bone resection level below, at, or above fibular head; 0 to 2), metaphysis (number of sufficiently cemented zones; 0 to 4), and diaphysis (canal filling ratio (CFR); %). The intraclass correlation coefficient (ICC) was calculated to quantify the agreement between observers. Multivariate logistic regression analysis was performed to assess the relationship between zonal fixation and rrTKA-AL.Results: Overall, 33 patients underwent a further rrTKA-AL from a total of 1,173 rTKAs where hybrid tibial components (2.8%) were used. Patients requiring rrTKA-AL had a significantly lower epiphyseal bone resection level (OR 0.43; 95% CI 0.23 to 0.76; p = 0.006), lower number of adequately cemented zones (OR 0.50; 95% CI 0.30 to 0.79; p = 0.004), but no difference in CFR (p = 0.858). Furthermore, patients needing rrTKA-AL had more frequently previous revisions (p = 0.047), a higher rate of a prior use of a stemmed tibial component (p = 0.011), and a higher Anderson Orthopaedic Research Institute classification (p < 0.001). Agreement of zonal fixation between observers was good (ICC 0.79 to 0.87).Conclusion: Patients in need of subsequent rrTKA-AL had lower epiphyseal bone resection levels and a lower number of sufficiently metaphyseal cemented zones following rTKA. These results emphasize the importance of appropriate metaphyseal fixation at rTKA. With this information, orthopaedic surgeons can identify patients at greater risk for rrTKA-AL and optimize their surgical technique in revision knee arthroplasty surgery.Cite this article: Bone Joint J 2025;107-B(1):65–71.


  • Open Access

    No difference in long-term micromotion between fully cemented and hybrid fixation in revision total knee arthroplasty: a randomized controlled trial

    by Kelly Mills, Ate B. Wymenga, Gijs G. van Hellemondt, Petra J. C. Heesterbeek

    Aims: Both the femoral and tibial component are usually cemented at revision total knee arthroplasty (rTKA), while stems can be added with either cemented or press-fit (hybrid) fixation. The aim of this study was to compare the long-term stability of rTKA with cemented and press-fitted stems, using radiostereometric analysis (RSA). Methods: This is a follow-up of a randomized controlled trial, initially involving 32 patients, of whom 19 (nine cemented, ten hybrid) were available for follow-up ten years postoperatively, when further RSA measurements were made. Micromotion of the femoral and tibial components was assessed using model-based RSA software (RSAcore). The clinical outcome was evaluated using the Knee Society Score (KSS), the Knee injury and Osteoarthritis Outcome Score (KOOS), and visual analogue scale (pain and satisfaction). Results: The median total femoral translation and rotation at ten years were 0.39 mm (interquartile range (IQR) 0.20 to 0.54) and 0.59° (IQR 0.46° to 0.73°) for the cemented group and 0.70 mm (IQR 0.15 to 0.77) and 0.78° (IQR 0.47° to 1.43°) for the hybrid group. For the tibial components this was 0.38 mm (IQR 0.33 to 0.85) and 0.98° (IQR 0.38° to 1.34°) for the cemented group and 0.42 mm (IQR 0.30 to 0.52) and 0.72° (IQR 0.62° to 0.82°) for the hybrid group. None of these values were significantly different between the two groups and there were no significant differences between the clinical scores in the two groups at this time. There was only one re-revision, in the hybrid group, for infection and not for aseptic loosening. Conclusion: These results show good long-term fixation with no difference in micromotion and clinical outcome between fully cemented and hybrid fixation in rTKA, which builds on earlier short- to mid-term results. The patients all had type I or II osseous defects, which may in part explain the good results. Cite this article: Bone Joint J 2022;104-B(7):875–883.


  • Open Access

    Flexible versus standard intramedullary rod in posterior stabilized primary total knee arthroplasty: protocol for a randomized controlled trial

    by M. R. Bénard, R. F. M. van Doremalen, A. B. Wymenga, P. J. C. Heesterbeek

    Background: In total knee arthroplasty (TKA) a flexible intramedullary rod can be used to account for sagittal bowing of the distal femur. Although patients report better post-operative functional outcome when the flexible rod was used, it is unknown how the use of the flexible rod affects the placement of the femoral TKA component, and how this relates to activities of daily living. It is expected that the use of the flexible rod will result in a more flexed femoral component, a larger patellar tendon moment arm, and consequently in better functional outcome. The goal of this study is to compare the flexible rod to the standard intramedullary rod in primary TKA in terms of fit of the TKA, functional outcome, and sizing of the femoral component.Methods: A single-blind randomized controlled trial with two groups (flexible vs standard rod), with patients blinded for group allocation, and 2 years post-operative follow-up. The fit of the TKA is quantified by two parameters: (1) the flexion angle of the TKA in the sagittal plane and (2) the sagittal profile of the distal femur compared between the pre-operative bone and the TKA. Both parameters are calculated in 3D volume images obtained using fluoroscopy. Functional outcome will be measured using (1) the timed Get-up and Go test (2), the stair climbing test (3), knee power output, and (4) patient and clinician reported outcomes. Different parameters will be measured during the TKA procedure to account for the invisibility of cartilage in the 3D volumes and to study if the amount of bone removed during the procedure is affected by group allocation.Discussion: The sagittal fit of TKA is not a standardized outcome measure. We discuss our choice of parameters to define the sagittal fit (i.e., flexion angle and sagittal profile), our choice for the parameters we measure during the TKA procedure to account for the lack of cartilage thickness in fluoroscopy, and our choice for the parameters to study if the amount of bone removed during the procedure is affected by group allocation. Lastly, we discuss the merits of this planned trial.Trial registration: Netherlands Trial Register,4888, registered 30 March 2015.https://www.trialregister.nl/trial/4888


  • Restoration of pre‐operative joint line orientation and alignment does not affect KSS and KOOS 1 year after total knee arthroplasty

    by Michele D’aMato, Nienke M. Kosse, Ate B. Wymenga

    Purpose: The objectives of this study were to examine the relation between clinical outcomes 1 year postoperatively, in a cohort of mechanically aligned total knee arthroplasties (TKA), and (1) the degrees of alignment change of the tibial, femoral and the hip–knee–ankle (HKA) angle; (2) the change of phenotype; (3) the postoperative knee joint line orientation to the floor.Methods: Pre‐operative and postoperative long‐leg X‐rays of 90 patients were used to determine the coronal alignment. The absolute difference between the pre‐operative and postoperative measurements was determined and the outcomes were categorized in whether or not a change in phenotype had occurred. Finally, the orientation of the knee joint line relative to the floor (tibial joint line angle—TJLA) was measured. Clinical outcomes were determined with the KOOS and KSS at 1‐year follow‐up.Results: The clinical outcomes (1) did not correlate with the absolute difference of the alignment measured; (2) did not show a difference between patients with or without a change in phenotype; and (3) were higher (KOOS ADL, Sport and QoL) in patients with a medial open TJLA.Conclusion: This study showed no correlation between clinical outcomes and joint line restoration of the femur, tibia or HKA in patients after TKA. Leaving the prosthesis with some degrees of under correction on the coronal plane maintaining the phenotype, was not associated to better clinical results compared to TKA overcorrection. Nevertheless, the results showed that patients with a medial open TJLA had better clinical outcomes than patients with a lateral open TJLA.Level of evidence: III.


  • Long-Term Outcome Following Revision Total Knee Arthroplasty is Associated With Indication for Revision

    by Paul J.H. van Rensch, Gerjon Hannink, Petra J.C. Heesterbeek, Ate B. Wymenga, Gijs G. van Hellemondt


  • Mid‐flexion laxity in the asymptomatic native knee is predominantly present on the lateral side

    by Malou E. M. Te Molder, Ate B. Wymenga, Petra J. C. Heesterbeek

    Purpose: During total knee arthroplasty (TKA), an orthopaedic surgeon is focused on soft‐tissue balance in extension (0°) and in flexion (90°). Patients with instability problems of the knee often report a feeling of instability during daily life activities, at around 30° knee flexion. There are no reference values available for knee laxity of healthy subjects in mid‐flexion (30°) and flexion (90°) for comparison with the TKA population. Therefore, the aim was to quantify varus and valgus knee laxity in extension, mid‐flexion and flexion in the asymptomatic native knee.Methods: In 40 healthy volunteers matched for age, gender and BMI with the TKA‐population, varus and valgus knee laxity in extension (0°), mid‐flexion (30°) and flexion (90°) was measured on low‐dose radiographs. For each subject, one randomly selected knee was stressed in extension, mid‐flexion and flexion (with 15 Nm) using a stress device.Results: Varus laxity in mid‐flexion was higher than in extension and flexion (p < 0.01). Valgus laxity tended to be highest in mid‐flexion laxity; however, no differences in knee laxity between flexion angles were seen (n.s.). Varus knee laxity in extension was higher in females than in males (p < 0.05).Conclusions: Mid‐flexion laxity in the native knee is more prominent on the lateral side of the knee, while the medial side is more stable and constrained. Varus knee laxity in extension was shown to be higher in females than in males.Level of evidence: Prognostic Level II.


  • Open Access

    Age, gender, functional KSS, reason for revision and type of bone defect predict functional outcome 5 years after revision total knee arthroplasty: a multivariable prediction model

    by Jan F. M. Verbeek, Gerjon Hannink, Koen C. Defoort, Ate B. Wymenga, Petra J. C. Heesterbeek

    The number of revision total knee arthroplasties (rTKA) is increasing. Unfortunately, not all patients benefit from revision surgery. The aim of this study was to develop a clinical prediction model that can be used to predict the functional outcome 5 years after rTKA.


  • Open Access

    Flexing and downsizing the femoral component is not detrimental to patellofemoral biomechanics in posterior-referencing cruciate-retaining total knee arthroplasty

    by Marco A. Marra, Marta Strzelczak, Petra J. C. Heesterbeek, Sebastiaan A. W. van de Groes, Dennis Janssen, Bart F. J. M. Koopman, Nico Verdonschot, Ate B. Wymenga

    Purpose When downsizing the femoral component to prevent mediolateral overhang, notching of the anterior femoral cortex may occur, which could be solved by flexing the femoral component. In this study, we investigated the effect of flexion of the femoral component on patellar tendon moment arm, patellofemoral forces and kinematics in posterior-referencing CR-TKA. Our hypothesis was that flexion of the femoral component increases the patellar tendon moment arm, reduces the patellofemoral forces and provides stable kinematics. Methods A validated musculoskeletal model of CR-TKA was used. The flexion of the femoral component was increased in four steps (0°, 3°, 6°, 9°) using posterior referencing, and different alignments were analysed in combination with three implant sizes (3, 4, 5). A chair-rising trial was analysed using the model, while simultaneously estimating quadriceps muscle force, patellofemoral contact force, tibiofemoral and patellofemoral kinematics. Results Compared to the reference case (size 4 and 0° flexion), for every 3° of increase in flexion of the femoral component the patellar tendon moment arm increased by 1% at knee extension. The peak quadriceps muscle force and patellofemoral contact force decreased by 2%, the patella shifted 0.8 mm more anteriorly and the remaining kinematics remained stable, with knee flexion. With the smaller size, the patellar tendon moment arm decreased by 6%, the quadriceps muscle force and patellofemoral contact force increased by 8 and 12%, and the patellar shifted 5 mm more posteriorly. Opposite trends were found with the bigger size. Conclusion Flexing the femoral component with posterior referencing reduced the patellofemoral contact forces during a simulated chair-rising trial with a patient-specific musculoskeletal model of CR-TKA. There seems to be little risk when flexing and downsizing the femoral component, compared to when using a bigger size and neutral alignment. These findings provide relevant information to surgeons who wish to prevent anterior notching when downsizing the femoral component.


  • Open Access

    Anterior referencing of tibial slope in total knee arthroplasty considerably influences knee kinematics: a musculoskeletal simulation study

    by Marco A. Marra, Marta Strzelczak, Petra J. C. Heesterbeek, Sebastiaan A. W. van de Groes, Dennis W. Janssen, Bart F. J. M. Koopman, Ate B. Wymenga, Nico J. J. Verdonschot

    Purpose In total knee arthroplasty (TKA), the posterior tibial slope is not always reconstructed correctly, and the knee ligaments may become too tight in flexion. To release a tight flexion gap, surgeons can increase the posterior tibial slope using two surgical resection techniques: the anterior tibial cortex (ACR) or the centre of tibial plateau (CPR) referencing. It is not known how this choice affects the knee laxity and function during activities of daily living. The aim of this study was to investigate the effect of tibial slope on knee laxity, kinematics and forces during a squatting activity using computer simulation techniques. We hypothesised that the effects depend on the referencing technique utilised. Methods A validated musculoskeletal model of TKA was used. Knee laxity tests were simulated in flexion and extension. Then, a squat motion was simulated to calculate: movement of the tibiofemoral joint (TFJ) contact points and patello-femoral joint (PFJ) contact force. All analyses were repeated with more anterior (−3°), neutral (0°), and more posterior tibial slope (+3°, +6°, +9°), and with two referencing techniques (ACR, CPR). Results Knee laxities increased dramatically with more posterior slope with the ACR technique (up to 400%), both in flexion and in extension. The CPR technique, instead, had much smaller effects (up to 42% variations). During squatting, more slope with the ACR technique resulted in larger movements of the TFJ contact point. The PFJ contact force decreased considerably with more slope with the CPR technique (12% body weight reduction every 3° more posterior slope), thanks to the preservation of the patellar height and quadriceps–femur load sharing. Conclusion ACR technique alters considerably the knee laxity, both in flexion and extensions, and surgeons should be cautious about its use. More slope with CPR technique induces more favourable TFJ kinematics and loading of the knee extensor apparatus and does not substantially alter knee laxity. Preferably, the tibial slope resection should be pre-planned thoroughly and performed using CPR technique as accurately as possible. Surgeons can directly translate the results of this study into the clinical practice.