Martin Baiker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Martin Baiker has a total of 73 co-authors. Here are the top co-authors by number of shared publications:
- Boudewijn P. F. Lelieveldt
Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
11 shared publications Eric L. Kaijzel
Department of Endocrinology, Leiden University Medical Center, Leiden, The Netherlands
4 shared publications- Beerend P. Hierck
Department of Anatomy and Embryology, Leiden University Medical Center, Leiden, The Netherlands
3 shared publications Ivo Que
Department of Endocrinology, Leiden University Medical Center, Leiden, The Netherlands
3 shared publicationsRobert E. Poelmann
3 shared publicationsA. Khmelinskii
Division of Image Processing, Dept. of Radiology, LUMC, Leiden, the Netherlands
2 shared publications
Latest Publications
- 12 October 2023
- Published by Elsevier in Forensic Science International
- Vol. 353, 111858
Automated interpretation of comparison scores for firearm toolmarks on cartridge case primers
- 12 October 2023
- Published by Elsevier in Forensic Science International
- Vol. 353, 111858
Automated interpretation of comparison scores for firearm toolmarks on cartridge case primers
- Open Access
- 12 November 2012
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 7 (11) , e48976
Segmentation and Visual Analysis of Whole-Body Mouse Skeleton microSPECT
Whole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput, multi-modality, postural and positioning variability). The goal of this study was to provide a method to align and compare side-by-side multiple whole-body skeleton SPECT datasets in a common reference, thus eliminating acquisition variability that exists between the subjects in cross-sectional and multi-modal studies. Six whole-body SPECT/CT datasets of BALB/c mice injected with bone targeting tracers 99mTc-methylene diphosphonate (99mTc-MDP) and 99mTc-hydroxymethane diphosphonate (99mTc-HDP) were used to evaluate the proposed method. An articulated version of the MOBY whole-body mouse atlas was used as a common reference. Its individual bones were registered one-by-one to the skeleton extracted from the acquired SPECT data following an anatomical hierarchical tree. Sequential registration was used while constraining the local degrees of freedom (DoFs) of each bone in accordance to the type of joint and its range of motion. The Articulated Planar Reformation (APR) algorithm was applied to the segmented data for side-by-side change visualization and comparison of data. To quantitatively evaluate the proposed algorithm, bone segmentations of extracted skeletons from the correspondent CT datasets were used. Euclidean point to surface distances between each dataset and the MOBY atlas were calculated. The obtained results indicate that after registration, the mean Euclidean distance decreased from 11.5±12.1 to 2.6±2.1 voxels. The proposed approach yielded satisfactory segmentation results with minimal user intervention. It proved to be robust for “incomplete” data (large chunks of skeleton missing) and for an intuitive exploration and comparison of multi-modal SPECT/CT cross-sectional mouse data.
- 12 November 2012
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 7 (11) , e48976
Open AccessSegmentation and Visual Analysis of Whole-Body Mouse Skeleton microSPECT
Whole-body SPECT small animal imaging is used to study cancer, and plays an important role in the development of new drugs. Comparing and exploring whole-body datasets can be a difficult and time-consuming task due to the inherent heterogeneity of the data (high volume/throughput, multi-modality, postural and positioning variability). The goal of this study was to provide a method to align and compare side-by-side multiple whole-body skeleton SPECT datasets in a common reference, thus eliminating acquisition variability that exists between the subjects in cross-sectional and multi-modal studies. Six whole-body SPECT/CT datasets of BALB/c mice injected with bone targeting tracers 99mTc-methylene diphosphonate (99mTc-MDP) and 99mTc-hydroxymethane diphosphonate (99mTc-HDP) were used to evaluate the proposed method. An articulated version of the MOBY whole-body mouse atlas was used as a common reference. Its individual bones were registered one-by-one to the skeleton extracted from the acquired SPECT data following an anatomical hierarchical tree. Sequential registration was used while constraining the local degrees of freedom (DoFs) of each bone in accordance to the type of joint and its range of motion. The Articulated Planar Reformation (APR) algorithm was applied to the segmented data for side-by-side change visualization and comparison of data. To quantitatively evaluate the proposed algorithm, bone segmentations of extracted skeletons from the correspondent CT datasets were used. Euclidean point to surface distances between each dataset and the MOBY atlas were calculated. The obtained results indicate that after registration, the mean Euclidean distance decreased from 11.5±12.1 to 2.6±2.1 voxels. The proposed approach yielded satisfactory segmentation results with minimal user intervention. It proved to be robust for “incomplete” data (large chunks of skeleton missing) and for an intuitive exploration and comparison of multi-modal SPECT/CT cross-sectional mouse data.
- 9 May 2012
- Published by Portico in BoneKEy Reports
- Vol. 1 (5) , 79
CT-based handling and analysis of preclinical multimodality imaging data of bone metastases
The pathogenesis of bone metastases is a complex and multifaceted process. Often multiple imaging modalities are needed to follow both the structural and functional changes over time during metastatic bone disease. Researchers face extended data sets of one experiment acquired with multiple modalities at multiple points in time. This review gives an overview of an integrated approach for handling these kinds of complex data. It focuses on the analysis of whole-body micro-computerized tomography and optical data handling. We show how researchers can generate side-by-side visualizations of scans taken with one imaging modality at multiple time points and with multiple modalities at one point. Moreover, we highlight methods for normalized volumes of interest selection and quantification of bone volume and thickness.
- 9 May 2012
- Published by Portico in BoneKEy Reports
- Vol. 1 (5) , 79
CT-based handling and analysis of preclinical multimodality imaging data of bone metastases
The pathogenesis of bone metastases is a complex and multifaceted process. Often multiple imaging modalities are needed to follow both the structural and functional changes over time during metastatic bone disease. Researchers face extended data sets of one experiment acquired with multiple modalities at multiple points in time. This review gives an overview of an integrated approach for handling these kinds of complex data. It focuses on the analysis of whole-body micro-computerized tomography and optical data handling. We show how researchers can generate side-by-side visualizations of scans taken with one imaging modality at multiple time points and with multiple modalities at one point. Moreover, we highlight methods for normalized volumes of interest selection and quantification of bone volume and thickness.
- Open Access
- 13 October 2011
- Published by Springer Nature in Molecular Imaging and Biology
- Vol. 14 (4) , 420-430
Automated Bone Volume and Thickness Measurements in Small Animal Whole-Body MicroCT Data
- 13 October 2011
- Published by Springer Nature in Molecular Imaging and Biology
- Vol. 14 (4) , 420-430
Open AccessAutomated Bone Volume and Thickness Measurements in Small Animal Whole-Body MicroCT Data
- 1 March 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 437-440
Atlas-based articulated skeleton segmentation of SPECT mouse data
In this paper we propose an automated articulated atlas-based approach for bone segmentation in whole-body μSPECT data of mice, obtained by injecting the 99m Tc-methylene diphosphonate ( 99m Tc - MDP). This is a difficult task, since SPECT data is usually noisy and low resolution, and the skeleton image is incomplete with several portions missing (e.g.: in limbs and skull). For this purpose the articulated version of the MOBY atlas skeleton with a correspondent hierarchical tree description is used. Iterative Closest Point registration is used, while constraining the local degrees of freedom (DoFs) in accordance to the type of joint and its range of motion. The method was tested using 3 whole-body μSPECT mouse datasets acquired using a NanoSPECT/CT scanner for small animals and the MOBY atlas. To evaluate the proposed algorithm, manual bone segmentations of extracted skeletons from the correspondent CT datasets were used. Euclidean point to surface distances for each dataset and the MOBY atlas were calculated. The obtained results indicate that after registration, the mean Euclidean distance descreased from 8.37 ± 8.70 to 2.27 ± 2.06 voxels. The results were presented using a novel method for change visualization in small animal imaging (Articulated Planar Reformation).
- 1 March 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 437-440
Atlas-based articulated skeleton segmentation of SPECT mouse data
In this paper we propose an automated articulated atlas-based approach for bone segmentation in whole-body μSPECT data of mice, obtained by injecting the 99m Tc-methylene diphosphonate ( 99m Tc - MDP). This is a difficult task, since SPECT data is usually noisy and low resolution, and the skeleton image is incomplete with several portions missing (e.g.: in limbs and skull). For this purpose the articulated version of the MOBY atlas skeleton with a correspondent hierarchical tree description is used. Iterative Closest Point registration is used, while constraining the local degrees of freedom (DoFs) in accordance to the type of joint and its range of motion. The method was tested using 3 whole-body μSPECT mouse datasets acquired using a NanoSPECT/CT scanner for small animals and the MOBY atlas. To evaluate the proposed algorithm, manual bone segmentations of extracted skeletons from the correspondent CT datasets were used. Euclidean point to surface distances for each dataset and the MOBY atlas were calculated. The obtained results indicate that after registration, the mean Euclidean distance descreased from 8.37 ± 8.70 to 2.27 ± 2.06 voxels. The results were presented using a novel method for change visualization in small animal imaging (Articulated Planar Reformation).
- 1 January 2011
- Published by Springer Nature
- Vol. 14, 516-523
Automated Registration of Whole-Body Follow-Up MicroCT Data of Mice
In vivo MicroCT imaging of disease models at multiple time points is of great importance for preclinical oncological research, to monitor disease progression. However, the great postural variability between animals in the imaging device complicates data comparison. In this paper we propose a method for automated registration of whole-body MicroCT follow-up datasets of mice. First, we register the skeleton, the lungs and the skin of an articulated animal atlas (Segars et al. 2004) to MicroCT datasets, yielding point correspondence of these structures over all time points. This correspondence is then used to regularize an intensity-based B-spline registration. This two step approach combines the robustness of model-based registration with the high accuracy of intensity-based registration. We demonstrate our approach using challenging whole-body in vivo follow-up MicroCT data and obtain subvoxel accuracy for the skeleton and the skin, based on the Euclidean surface distance. The method is computationally efficient and enables high resolution whole-body registration in ≈17 minutes with unoptimized code, mostly executed single-threaded.
- 1 January 2011
- Published by Springer Nature
- Vol. 14, 516-523
Automated Registration of Whole-Body Follow-Up MicroCT Data of Mice
In vivo MicroCT imaging of disease models at multiple time points is of great importance for preclinical oncological research, to monitor disease progression. However, the great postural variability between animals in the imaging device complicates data comparison. In this paper we propose a method for automated registration of whole-body MicroCT follow-up datasets of mice. First, we register the skeleton, the lungs and the skin of an articulated animal atlas (Segars et al. 2004) to MicroCT datasets, yielding point correspondence of these structures over all time points. This correspondence is then used to regularize an intensity-based B-spline registration. This two step approach combines the robustness of model-based registration with the high accuracy of intensity-based registration. We demonstrate our approach using challenging whole-body in vivo follow-up MicroCT data and obtain subvoxel accuracy for the skeleton and the skin, based on the Euclidean surface distance. The method is computationally efficient and enables high resolution whole-body registration in ≈17 minutes with unoptimized code, mostly executed single-threaded.
- 1 December 2010
- Published by Elsevier in Medical Image Analysis
- Vol. 14 (6) , 723-737
Atlas-based whole-body segmentation of mice from low-contrast Micro-CT data
- 1 December 2010
- Published by Elsevier in Medical Image Analysis
- Vol. 14 (6) , 723-737
Atlas-based whole-body segmentation of mice from low-contrast Micro-CT data
- 28 October 2010
- Published by Royal Society of Chemistry (RSC)
- p. 425-442
“In Vivo” Molecular Imaging
Whole body optical imaging (OI) refers to in vivo bioluminescence and fluorescence imaging. This technology is one of the most rapidly emerging to non-invasively follow molecular and cellular processes in small laboratory animals. Optical imaging modalities are based on very sensitive devices capable of detecting and quantifying bioluminescent or fluorescent light that is transmitted through tissues from internal sources. This imaging of very weak visible light is rendered possible by the use of cooled charged coupled device (CCCD) cameras, peltier-cooled detectors, micro-plate channel intensifiers and liquid-nitrogen-cooled detectors aimed at enhancing the signal-to-noise ratio by decreasing the background or amplifying the signal. The role of molecular imaging in pre-clinical research is continuously evolving. Particularly in small animal models in biomedical research, optical imaging technologies are frequently used to visualize normal as well as aberrant cellular processes at a molecular-genetic or cellular level of function. This chapter will focus on the application of whole body bioluminescence molecular imaging strategies -either alone or in combination with CT- in different fields (e.g. to study non-invasive and real-time imaging of gene expression, tumor progression and metastasis, and response to therapeutic intervention).
- 28 October 2010
- Published by Royal Society of Chemistry (RSC)
- p. 425-442
“In Vivo” Molecular Imaging
Whole body optical imaging (OI) refers to in vivo bioluminescence and fluorescence imaging. This technology is one of the most rapidly emerging to non-invasively follow molecular and cellular processes in small laboratory animals. Optical imaging modalities are based on very sensitive devices capable of detecting and quantifying bioluminescent or fluorescent light that is transmitted through tissues from internal sources. This imaging of very weak visible light is rendered possible by the use of cooled charged coupled device (CCCD) cameras, peltier-cooled detectors, micro-plate channel intensifiers and liquid-nitrogen-cooled detectors aimed at enhancing the signal-to-noise ratio by decreasing the background or amplifying the signal. The role of molecular imaging in pre-clinical research is continuously evolving. Particularly in small animal models in biomedical research, optical imaging technologies are frequently used to visualize normal as well as aberrant cellular processes at a molecular-genetic or cellular level of function. This chapter will focus on the application of whole body bioluminescence molecular imaging strategies -either alone or in combination with CT- in different fields (e.g. to study non-invasive and real-time imaging of gene expression, tumor progression and metastasis, and response to therapeutic intervention).
- Open Access
- 8 September 2010
- Published by Springer Nature in Molecular Imaging and Biology
- Vol. 13 (5) , 898-910
Articulated Whole-Body Atlases for Small Animal Image Analysis: Construction and Applications
Purpose Using three publicly available small-animal atlases (Sprague–Dawley rat, MOBY, and Digimouse), we built three articulated atlases and present several applications in the scope of molecular imaging. Procedures Major bones/bone groups were manually segmented for each atlas skeleton. Then, a kinematic model for each atlas was built: each joint position was identified and the corresponding degrees of freedom were specified. Results The articulated atlases enable automated registration into a common coordinate frame of multimodal small-animal imaging data. This eliminates the postural variability (e.g., of the head, back, and front limbs) that occurs in different time steps and due to modality differences and nonstandardized acquisition protocols. Conclusions The articulated atlas proves to be a useful tool for multimodality image combination, follow-up studies, and image processing in the scope of molecular imaging. The proposed models were made publicly available.
- 8 September 2010
- Published by Springer Nature in Molecular Imaging and Biology
- Vol. 13 (5) , 898-910
Open AccessArticulated Whole-Body Atlases for Small Animal Image Analysis: Construction and Applications
Purpose Using three publicly available small-animal atlases (Sprague–Dawley rat, MOBY, and Digimouse), we built three articulated atlases and present several applications in the scope of molecular imaging. Procedures Major bones/bone groups were manually segmented for each atlas skeleton. Then, a kinematic model for each atlas was built: each joint position was identified and the corresponding degrees of freedom were specified. Results The articulated atlases enable automated registration into a common coordinate frame of multimodal small-animal imaging data. This eliminates the postural variability (e.g., of the head, back, and front limbs) that occurs in different time steps and due to modality differences and nonstandardized acquisition protocols. Conclusions The articulated atlas proves to be a useful tool for multimodality image combination, follow-up studies, and image processing in the scope of molecular imaging. The proposed models were made publicly available.
- 1 January 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1197-1200
Atlas-based organ & bone approximation for ex-vivo μMRI mouse data: A pilot study
In this paper we propose a novel semi-automated atlas-based approach for organ and bone approximation for micro-Magnetic Resonance Imaging (μMRI) data of mice. Based on a set of 18 manually indicated landmarks at specific joint & bone locations, individual atlas bones (pelvis, limb bones and sternum) are mapped to the target in a first step and a sparse set of corresponding landmarks on a skin surface representation is determined in a second step. Subsequently, this sparse set on the skin is used to derive a dense set of correspondences relying on matching spectra of local geodesic distances. Finally, determined by the skin correspondence, a Thin-Plate-Spline (TPS) approximation of major organs (heart, lungs, liver, spleen, stomach, kidneys) is performed. The method was tested using 3 μMRI mouse datasets and the MOBY atlas. The performance of the organ approximation algorithm was estimated using manual segmentations of 6 organs for each MRI dataset and calculating Dice indices of organ-volume overlap for each dataset and the atlas. The obtained results indicate excellent fitting of heart and kidneys and moderate fitting of spleen, lungs, liver and stomach. These initial results are satisfactory and comparable to other organ mapping studies using different approaches and μComputed Tomography (CT) mouse data.
- 1 January 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1197-1200
Atlas-based organ & bone approximation for ex-vivo μMRI mouse data: A pilot study
In this paper we propose a novel semi-automated atlas-based approach for organ and bone approximation for micro-Magnetic Resonance Imaging (μMRI) data of mice. Based on a set of 18 manually indicated landmarks at specific joint & bone locations, individual atlas bones (pelvis, limb bones and sternum) are mapped to the target in a first step and a sparse set of corresponding landmarks on a skin surface representation is determined in a second step. Subsequently, this sparse set on the skin is used to derive a dense set of correspondences relying on matching spectra of local geodesic distances. Finally, determined by the skin correspondence, a Thin-Plate-Spline (TPS) approximation of major organs (heart, lungs, liver, spleen, stomach, kidneys) is performed. The method was tested using 3 μMRI mouse datasets and the MOBY atlas. The performance of the organ approximation algorithm was estimated using manual segmentations of 6 organs for each MRI dataset and calculating Dice indices of organ-volume overlap for each dataset and the atlas. The obtained results indicate excellent fitting of heart and kidneys and moderate fitting of spleen, lungs, liver and stomach. These initial results are satisfactory and comparable to other organ mapping studies using different approaches and μComputed Tomography (CT) mouse data.