Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rodrigo Amorim Bezerra da Silva has a total of 102 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    On-Site Electrochemical Detection of Sulfentrazone Using a Fully 3D-Printed Portable Sensing Platform

    by Jacqueline Marques Petroni, Jonas Raul Balbinoti, Elias Jorge, Osvaldo Cavalcante da Costa Neto, Rodrigo Amorim Bezerra da Silva, Magno Aparecido GonçaLves Trindade, Bruno Gabriel Lucca

    The widespread use of pesticides in agricultural activities has increased concerns regarding environmental contamination and occupational exposure, particularly through dermal contact. In this work, we report a portable and low-cost electrochemical sensing platform for on-site monitoring of sulfentrazone (SFT), a herbicide extensively used in eucalyptus cultivation. The proposed device consists of a fully 3D-printed miniaturized electrochemical system fabricated by multi-material printing using conductive and non-conductive filaments, enabling accessible and decentralized analysis. SFT detection was performed by square-wave voltammetry (SWV), exhibiting a single irreversible oxidation peak at +0.86 V (pH 6.5). Under optimized conditions, the platform showed a linear response from 1.1 to 101.1 μmol L–1, with a limit of detection of 0.50 μmol L–1 (obtained through IUPAC recommendations). The proposed approach demonstrated satisfactory accuracy and precision in spiked tap water samples, with recoveries ranging from 100 to 103% and RSD values ≤ 2.9% (n = 3). Additionally, the platform was successfully applied to porcine skin samples as a model for detecting dermal contamination, yielding recoveries between 81 and 111%. The combination of additive manufacturing and electrochemical sensing provides a simple, reliable, and field-deployable strategy for SFT monitoring in environmental and biological matrices, highlighting the potential of fully 3D-printed analytical platforms for occupational and environmental applications.

  • Open Access

    MICRO (Multimaterial, Integrated, Compact, Ready-to-Plug, One-Step 3D-Printed): A Simple-to-Use Electrochemical Device for On-Site Analysis and Drug Screening

    by Tiago Moraes Zavarize, Fárlon Felipe Silva Xavier, Augusto dos Santos Novais, Celso Luciano de Araújo, Edmar Isaias de Melo, Ettore Ferrari Júnior, Bruno Gabriel Lucca, Lucas Franco Ferreira, Rodrigo Amorim Bezerra da Silva

    3D printing has emerged as a transformative technology in electroanalytical chemistry, enabling the rapid, low-cost, and reproducible mass fabrication of portable devices and sensors for several areas such as environmental, clinical, food, and forensic applications. Herein, we present a multimaterial, integrated, compact, ready-to-plug, and one-step additively manufactured electrochemical cell (MICRO-EC3D). This all-in-one device was fabricated using a dual-extruder 3D printer and comprises a single unit containing the three electrodes/tracks (conductive carbon black–polylactic acid, CB-PLA) as well as the body containing an embedded mini solution reservoir (polyethylene terephthalate glycol, PETG). This arrangement eliminates the assembling of external accessories and allows the introduction of miniaturized stirrers. Unlike previous similar 3D-printed devices, the proposed microcell is readily interfaced to mobile apparatus (hand-held potentiostats and smartphones) through user-friendly USB-based connectors (wireless, crocodile clip, or banana pin). After a quick chemical (immersion in 5.0 M NaOH for 3 min) and electrochemical treatment (+1.4 V for 200 s and −1.0 V for 200 s in 0.5 M NaOH), this device showed performance comparable to a commercial carbon screen-printed electrode for model analytes (ferricyanide, paracetamol, and nitrite). The analytical use of the device was demonstrated for the square-wave voltammetric detection of anabolic steroid oxymetholone (OXM), in which two linear responses (1.0 to 5.0 and 6.0 to 10.0 μM; R 2 > 0.99) and a limit of detection of 0.21 μM were obtained. These values were suitable for the screening of OXM in three seized samples, yielding results consistent with gas chromatography–mass spectrometry. These findings evidence the potential of MICRO-EC3D as an easy-to-use, portable, and low-cost (<ten cents) tool for on-site preliminary forensic analysis and for increasing the acceptance and popularity of electrochemical methods, mainly among inexpert analysts.


  • Open Access

    Determination of Hormone 17 β ‐Estradiol Using Graphite‐Acrylonitrile Butadiene Styrene Electrode Coupled to User‐Friendly 3D‐Printed Batch Injection Analysis Cell

    by Daiane Gabriela Ribeiro, Bruno Gabriel Lucca, Rodrigo Amorim Bezerra da Silva, Edmar Isaias de Melo

    17 β ‐estradiol (E2) is the main female sex hormone widely found in pharmaceutics indicated for contraception and replacement therapy. Because this hormone is secreted by the body and contaminates the aquatic environment, it is considered an important organic pollutant to monitor due to its action on the human body as an endocrine disruptor. Therefore, the development of rapid, sensitive, precise, and portable methods is relevant for its quantification “in situ” in different matrices. In this context we propose the determination of E2 using a fast low‐cost system composed of a graphite‐acrylonitrile butadiene styrene (coated on 3D‐printed ABS substrate) electrode assembled in a novel user‐friendly 3D‐printed batch injection analysis system with amperometric detection (BIA‐AD). The best electrochemical behavior was obtained in 0.04 mol L −1 Britton‐Robinson buffer (pH 3.0) in which an irreversible oxidation was noted at +0.85 V. Under the optimized conditions of BIA‐AD (detection potential = +1.1 V, injection volume = 100 µL, dispensing rate = 142 µL s −1 ), a sensitivity of 0.154 µA µmol −1  L, a linear range of 0.1–7.0 µmol L −1 , an experimental LOD of 0.1 µmol L −1 , and an analytical frequency of 240 injections per hour were obtained. Good precision was reached for sequential injections of E2 at three concentration levels (8.6%, 3.2%, and 5.0% for 0.5, 3.0, and 6.0 µmol L −1 , respectively). Moreover, good interelectrode reproducibility was reached (RSD = 5.5%; n = 4), which confirms good manufacturing efficiency. The method was applied for the determination of E2 in pharmaceutical sample and river water. The results found in a pharmaceutical sample were statistically similar to the obtained by a UV–vis spectrophotometric method. The value found in river water was below the experimental LOD. Thus, this sample was fortified with different concentrations of E2, obtaining recoveries between 100% and 116%, which confirms the good accuracy of the method. The proposed BIA‐AD is promising for the fast on‐site determination of E2 in different matrices.


  • Open Access

    Voltammetric Determination of Carbendazim Using a Biochar Modified 3D‐Printed Based Sensor

    by Maria Zizi Martins Mendonça, Bruno Gabriel Lucca, Edmar Isaias de Melo, Rodrigo Amorim Bezerra da Silva, Vicelma Luiz Cardoso

    3D printing has been benefiting electroanalysis due to the quick and low‐cost manufacture of cells and sensors. For this production, the choice of eco‐friendly materials is welcome due to the agreement to the principles of sustainability, green chemistry, and circular economy. In this work a novel 3D‐printed sensor modified with biochar (BC) from coffee husk residues is proposed for the determination of the fungicide carbendazim in natural waters using square wave voltammetry (SWV). The sensor was prepared through the coating of an insulating ring‐shaped 3D‐printed substrate (Acrylonitrile Butadiene Styrene/ABS) with a BC‐modified conductive ink (acetone, ABS, graphite, and BC). Using the optimized sensor (10% wt. of BC) in 0.1 mol L−1 phosphate buffer (pH 2.0) and optimized SWV parameters (Es = 2 mV, f = 15 Hz and A = 120 mV), the detectability of carbendazim was 50% higher than unmodified, and a linear range (LR) from 0.25 to 15.00 µmol L−1 (R2 = 0.998) and a limit of detection (LOD) (S/N = 3) of 50 nmol L−1 were obtained. Good inter‐electrode (RSD = 6.21%; n = 6) and inter‐day (RSD = 6.96%; n = 10) reproducibility and accuracy (recovery between 92.71% and 96.43% in water samples) were obtained. This alternative sensor is simpler than those fabricated using BC‐modified filaments, being promising for the trace level analysis of environmental pollutants.


  • Exploring the coating of 3D-printed insulating substrates with conductive composites: a simple, cheap and versatile strategy to prepare customized high-performance electrochemical sensors

    by Fabiano Mendonça de Oliveira, Maria Zizi Martins Mendonça, Natália Canhete de Moraes, Jacqueline Marques Petroni, Matheus Meneguel Neves, Edmar Isaias de Melo, Bruno Gabriel Lucca, Rodrigo Amorim Bezerra da Silva

    The development of 3D-printed electrochemical sensors by fused deposition modeling (FDM) has been increasing exponentially in the last five years. In this context, commercial conductive filaments composed of a blend of carbon particles (e.g., graphene or carbon black (CB)) and insulating thermoplastic polymers (e.g., polylactic acid (PLA) or acrylonitrile butadiene styrene (ABS)) have been widely used for electrode fabrication. However, such materials may be expensive and the electrodes when used “as-printed” exhibit poor electrochemical performance as a function of the low content of conductive particles in the composition (∼10 to 20 wt%), which requires one or more post-treatment steps (e.g. polishing, chemical, electrochemical, and photochemical) to reach good electrochemical performance. In this technical note a less used approach to produce “ready-to-use” electrochemical platforms based on 3D printing is explored, which consists of the coating of 3D-printed insulating substrates with homemade conductive composites. To demonstrate the potentiality of this alternative protocol, 3D-printed ABS insulating substrates at two geometries were coated in a highly loaded graphite (55 wt%) homemade composite (G–ABS) and evaluated for the detection of the ferri/ferrocyanide redox probe and model analytes in stationary and hydrodynamic 3D-printed systems (nitrite in micro-flow injection analysis/μFIA and paracetamol in batch injection analysis/BIA, respectively). The analytical parameters acquired with the coated electrodes were comparable to those obtained using conventional electrodes (glassy carbon, boron-doped diamond and carbon screen-printed) and 3D-printed sensors fabricated with commercial filaments. Moreover, the inclusion of carbon black in the fluid conductive composite was demonstrated as a perspective to obtain modified coated 3D-printed surfaces easily for the first time. This alternative “do it yourself” strategy is promising for the large-scale production of very cheap (US$ 0.08) and high-performance electrodes based on FDM 3D printing. Moreover, this approach dispenses the acquisition of commercial conductive filaments and the laborious development of homemade filaments.


  • Multi sensor compatible 3D-printed electrochemical cell for voltammetric drug screening

    by Priscila Alves Ferreira, Fabiano Mendonça de Oliveira, Edmar Isaias de Melo, Adriana Evaristo de Carvalho, Bruno Gabriel Lucca, Valdir Souza Ferreira, Rodrigo Amorim Bezerra da Silva


  • Cloud-point extraction associated with voltammetry: preconcentration and elimination of the sample matrix for trace determination of methyl parathion in honey

    by Priscila A. R. de Sousa, André L. Squissato, Rodrigo A. A. Munoz, Luciana M. Coelho, Edmar I. de Melo, Rodrigo A. B. da Silva

    This work presents the association of cloud point extraction (CPE) and electroanalysis for the selective and sensitive determination of methyl parathion (MP) in honey. The CPE step provided the pre-concentration of MP from a complex sample, in which the optimized extraction parameters (Triton X-100 concentration of 0.75% w/v, NaCl concentration of 1.0% w/v and heating time of 30 min) were investigated using a factorial design (23). The detection of MP was performed using a cathodically pre-treated boron-doped diamond (BDD) working electrode and square wave voltammetry (SWV), after a suitable dilution of the CPE extract in Britton–Robinson buffer pH 6.0 as the supporting electrolyte. MP presented three electrochemical processes over the BDD surface, but only the reduction peak at around −0.7 V was monitored for the MP determination (higher detectability). Improved reproducibility was reached by applying an in situ cleaning step (+2.0 V for 15 s) followed by a re-activation process (−2.0 V for 15 s) between measurements. Using the optimized variables, a linear range between 0.1 and 2.0 μmol L−1 was obtained for MP with a limit of detection of 0.006 μmol L−1, a 6-fold lower value when compared with the value attained without the CPE step. The experimental enrichment factor of MP was 6.1. Also, the optimized CPE allowed the determination of MP in honey samples with good accuracy (recovery between 94 and 106%), which was not possible using direct detection (without CPE) due to the matrix interference. This is the first paper that demonstrates the combination of CPE and electroanalysis for the determination of an organic compound.


  • Electrochemical detection of the synthetic cathinone 3,4-methylenedioxypyrovalerone using carbon screen-printed electrodes: A fast, simple and sensitive screening method for forensic samples

    by Camila D. Lima, Rosa A.S. Couto, Luciano C. Arantes, Pablo A. Marinho, Dilton M. Pimentel, M. Beatriz Quinaz, Rodrigo A.B. da Silva, Eduardo M. Richter, Sandro L. Barbosa, Wallans T.P. dos Santos


  • Fast Screening and Determination of Tadalafil in Pharmaceutics by Batch Injection Analysis (BIA) with Amperometric Detection

    by Fabiano M. de Oliveira, Priscila A. Ferreira, Camila G. Neves, Tamires M. Rosa, Wallans T. P. dos Santos, Edmar I. de Melo, Rodrigo A. B. da Silva

    Tadalafil (TDL) is the active ingredient of Cialis®, one of the top selling drugs for the treatment of erectile dysfunction and very counterfeit worldwide. In this work, two amperometric methods are proposed for (1) determination and (2) screening of TDL in pharmaceutical products using a boron‐doped diamond electrode assembled in a 3D‐printed Batch Injection Analysis cell. Cyclic voltammograms showed that TDL presented one irreversible oxidation and pH dependent process at about 1.0 V (vs Ag/AgCl) with maximum current in Britton‐Robinson buffer pH 4.0. For the method 1, a constant potential of+1.3 V was applied and, under optimized conditions, good linear range for TDL quantification (from 1.0 to 150.0 μmol L−1), LOD of 1.0 μmol L−1 (experimental), high repeatability (RSD=1.9 %; n=20) and good sample throughput (270 h−1) were obtained. Method 1 was used for the determination of TDL in genuine and generic formulations, and the results were not statistically different from a comparative spectrophotometric method at a 95 % confidence level. In method 2, the multiple pulse amperometric detection (MPAD) was taken through the application of sequential potential pulses (+1.0, +1.2 and +1.5 V). The comparative profile of each sample was done after peak ratios from each amperogram (R1=ipa1.2V/ipa1.0V, R2=ipa1.5V/ipa1.2V, R3=ipa1.5V/ipa1.0V). This simple current normalization allowed the recognition of similar profiles between samples containing only TDL and differences between samples adulterated with other drugs (sildenafil, paracetamol, dipyrone, and caffeine). Finally, these methods are fast, use portable low‐cost apparatus and unmodified electrodes. Such features are attractive for routine analysis in forensic and pharmaceutical sciences.