DMDonal S. McNally

Donal S. McNally

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Donal S. McNally has a total of 149 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Comparison of standard automotive industry injury predictors and actual injury sustained during significant whiplash events

    by Ekaterina Smotrova, Lucy Morris, Donal McNally

    Purpose: We present a unique opportunity to compare standard neck injury criteria (used by the automotive industry to predict injury) with real-life injuries. The injuries sustained during, and the overall kinematics of, a television demonstration of whiplash mechanics were used to inform and validate a vertebral level model of neck mechanics to examine the relevance of current injury criteria used by the automotive industry. Methods: Frontal and rear impact pulses, obtained from videos of sled motion, were used to drive a MADYMO human model to generate detailed segmental level biomechanics. The maximum amplitude of the frontal and rear crash pulses was 166 ms−2 and 196 ms−2, respectively, both with a duration of 0.137 s. The MADYMO model was used to predict standard automotive neck injury criteria as well as detailed mechanics of each cervical segment. Results: Whilst the subject suffered significant upper neck injuries, these were not predicted by conventional upper neck injury criteria (Nij and Nkm). However, the model did predict anterior accelerations of C1 and C2 of 40 g, which is 5 times higher than the threshold of the acceleration for alar ligament injury. Similarly, excessive anterior shear displacement (15 mm) of the skull relative to C2 was predicted. Predictions of NIC, an injury criterion relevant to the lower neck, as well as maximum flexion angles for the lower cervical segments (C3–T1) exceeded injury thresholds. Conclusion: The criteria used by the automotive industry as standard surrogates for upper neck injury (Nij and Nkm) did not predict the significant cranio-cervical junction injury observed clinically.


  • On the axial distribution of plaque stress: Influence of stenosis severity, lipid core stiffness, lipid core length and fibrous cap stiffness

    by César Alegre-Martínez, Kwing-So Choi, Outi Tammisola, Donal McNally

    Numerical simulations of blood flow through a partially-blocked axisymmetric artery are performed to investigate the stress distributions in the plaque. We show that the combined effect of stenosis severity and the stiffness of the lipid core can drastically change the axial stress distribution, strongly affecting the potential sites of plaque rupture. The core stiffness is also an important factor when assessing plaque vulnerability, where a mild stenosis with a lipid-filled core presents higher stress levels than a severe stenosis with a calcified plaque. A shorter lipid core gives rise to an increase in the stress levels. However, the fibrous cap stiffness does not influence the stress distributions for the range of values considered in this work. Based on these mechanical analyses, we identify potential sites of rupture in the axial direction for each case: the midpoints of the upstream and downstream regions of the stenosis (for severe, lipid-filled plaques), the ends of the lipid core (for short cores), and the middle of the stenosis (for mild stenoses with positive remodelling of the arterial wall).


  • Open Access

    Computational mechanical characterization of geometrically transformed Schwarz P lattice tissue scaffolds fabricated via two photon polymerization (2PP)

    by Adi Z. Zabidi, Shuguang Li, Reda M. Felfel, Kathryn G. Thomas, David M. Grant, Donal McNally, Colin Scotchford


  • Exploring Median Nerve Biomechanics within the Wrist Using Ultrasonography

    by Alyson Langley, Donal McNaliy, Christine M. Haslegrave


  • Wear analysis of explanted conventional metal back polyethylene glenoid liners

    by Gyorgy Kocsis, Charlie J. Payne, Angus Wallace, Donal McNally

    Glenoid component wear and loosening is the Achilles heel of total shoulder replacement. Analysis of failed, revised implants might give an insight into the causes of component failure. Volumetric assessment of conventional total shoulder replacement glenoid liner wear rate and scanning electron microscopy was accomplished in this study for the purpose. Coherence scanning interferometry (white light scanner) 3D images were acquired. This method requires no physical contact, ionising radiation or extensive surface preparation. Twenty-four Nottingham total shoulder replacement system metal - back glenoid liners were explanted from revision shoulder arthroplasty cases. A Phase Vision Quartz DBE 800 scanner was used to scan the explanted polyethylene liners. The images of worn liners were registered to the reference image. Differences in wear and wear rate were quantified and central and non-central wear groups were distinguished. The Central wear group had a polyethylene wear rate of 115 ± 55mm3/year (mean ± SD). The non-central group showed a wear rate of 112 ± 42 mm3/year (mean ± SD), which was not significantly different from the central wear group (p = 0.426) Polyethylene liners showing edge wear from unstable shoulder replacements showed a wear rate of 545 mm3/year. Scanning electron microscopy images showed that the polyethylene was wearing in laminar flakes which indicated fatigue wear. The volumetric wear rate was found to be more than twice as fast as in the case of total hip replacement with the acetabular liner made of the same type of polyethylene. Use of coherence scanning interferometry is proposed for wear analysis.


  • Effect of mechanical preconditioning on the electrical properties of knitted conductive textiles during cyclic loading

    by Cristina Isaia, Donal S McNally, Simon A McMaster, David T Branson

    This paper presents, for the first time, the electrical response of knitted conductive fabrics to a considerable number of cycles of deformation in view of their use as wearable sensors. The changes in the electrical properties of four knitted conductive textiles, made of 20% stainless steel and 80% polyester fibers, were studied during unidirectional elongation in an Instron machine. Two tests sessions of 250 stretch–recovery cycles were conducted for each sample at two elongation rates (9.6 and 12 mm/s) and at three constant currents (1, 3 and 6 mA). The first session assessed the effects of an extended cyclic mechanical loading (preconditioning) on the electrical properties, especially on the electrical stabilization. The second session, which followed after a 5 minute interval under identical conditions, investigated whether the stabilization and repeatability of the electrical features were maintained after rest. The influence of current and elongation rate on the resistance measurements was also analyzed. In particular, the presence of a semiconducting behavior of the stainless steel fibers was proved by means of different test currents. Lastly, the article shows the time-dependence of the fabrics by means of hysteresis graphs and their non-linear behavior thanks to a time–frequency analysis. All knit patterns exhibited interesting changes in electrical properties as a result of mechanical preconditioning and extended use. For instance, the gauge factor, which indicates the sensitivity of the fabric sensor, varied considerably with the number of cycles, being up to 20 times smaller than that measured using low cycle number protocols.


  • Open Access

    X-ray computed tomography and additive manufacturing in medicine: a review

    by Adam Thompson, Donal McNally, Ian Maskery, Richard K. Leach

    International Journal of Metrology and Quality Engineering (IJMQE),an international journal for the rapid publication of articles dealing with applied metrology and quality tools for process improvement in industry and in research


  • Open Access

    Neonatal head and torso vibration exposure during inter-hospital transfer

    by Laurence Blaxter, Mildrid Yeo, Donal McNally, John Crowe, Caroline Henry, Sarah Hill, Neil Mansfield, Andrew Leslie, Don Sharkey

    Inter-hospital transport of premature infants is increasingly common, given the centralisation of neonatal intensive care. However, it is known to be associated with anomalously increased morbidity, most notably brain injury, and with increased mortality from multifactorial causes. Surprisingly, there have been relatively few previous studies investigating the levels of mechanical shock and vibration hazard present during this vehicular transport pathway. Using a custom inertial datalogger, and analysis software, we quantify vibration and linear head acceleration. Mounting multiple inertial sensing units on the forehead and torso of neonatal patients and a preterm manikin, and on the chassis of transport incubators over the duration of inter-site transfers, we find that the resonant frequency of the mattress and harness system currently used to secure neonates inside incubators is [ ]. This couples to vehicle chassis vibration, increasing vibration exposure to the neonate. The vibration exposure per journey (A(8) using the ISO 2631 standard) was at least 20% of the action point value of current European Union regulations over all 12 neonatal transports studied, reaching 70% in two cases. Direct injury risk from linear head acceleration (HIC15) was negligible. Although the overall hazard was similar, vibration isolation differed substantially between sponge and air mattresses, with a manikin. Using a Global Positioning System datalogger alongside inertial sensors, vibration increased with vehicle speed only above 60 km/h. These preliminary findings suggest there is scope to engineer better systems for transferring sick infants, thus potentially improving their outcomes.


  • Investigation of changes in the electrical properties of novel knitted conductive textiles during cyclic loading

    by Cristina Isaia, Donal McNally, Simon A. McMaster, David T. Branson

    Combining stainless steel with polyester fibres adds an attractive conductive behaviour to the yarn. Once knitted in such a manner, fabrics develop sensing properties that make the textiles, also known as e-textiles, suitable for smart/wearable applications. Structural deformations of the fibres (e.g. stretching) will cause changes in the conductivity of the fabric. This work investigates changes in the electrical properties exhibited by four knitted conductive textiles made of 20% stainless steel and 80% polyester fibres during cyclic loading. The samples were preconditioned first with 500 hundred cycles of unidirectional elongation and, after a rest interval, tested again for repeatability at the same conditions. In both cases the electrical behaviour stabilises after a few tens of cycles. In particular the repeatability test exhibited a considerably smaller settling time and a larger resistance due to the mechanical stabilisation and the loosening of the fabrics, respectively. It was found that the current provided to the fabrics affects the resistance measurements by decreasing the resistance value at which the samples become electrically stable. The reported findings present a valid method for the electrical characterisation of conductive textiles for use in further studies as a wearable technology.


  • The Evaluation of Digital Rectal Examination for Assessment of Anal Tone in Suspected Cauda Equina Syndrome

    by Katrina Eve BMBS Sherlock, William Bmbs Turner, Sherief Elsayed, M. Bagouri, L. Baha, Bronek M. Boszczyk, Donal McNally

    Study Design. Seventy-five doctors completed a questionnaire documenting their grade, specialty, and experience in performing digital rectal examination (DRE). A model anus, using a pressure transducer surrounding an artificial canal, was assembled and calibrated. Participants performed 4 DREs on the model (with a break between attempts) and predicted tone as “reduced” or “normal” (35 and 60 mm Hg, respectively), followed by a “squeeze” test. Thirty health care assistants partook as a control group with no training in DRE. Objective. Our main objective was to investigate the validity of digital rectal examination (DRE) for assessment of anal tone. Summary of Background Data. Cauda equina syndrome represents the constellation of symptoms and signs resulting from compression of lumbrosacral nerve routes. Combined with subjective neurological findings, a reduction in anal tone is an important sign, deeming further imaging necessary. DRE is an invasive procedure used to assess anal tone despite debated accuracy. Methods. A total of 75 doctors from various specialties were asked to fill in a questionnaire detailing their grade, age, and area of expertise. In addition, information was gathered with regard to prior training in performing DRE to assess anal tone and the importance placed on any findings. Thirty hospital health care assistants (HCAs) were used as a control group. HCAs were selected as a control group because they receive no training on the technique and would never be required to perform it in their clinical practice. A model anus was assembled using a modified pediatric sphygmomanometer cuff to act as a sphincter. The cuff could be inflated to simulate a full range of anal tone. The cuff was incorporated into an artificial anal canal, which was, in turn, placed into a model buttock created from plaster of Paris. The apparatus was calibrated across a range of pressures. Results. In each attempt, 60%, 61%, 63%, and 67% of doctors correctly identified the anal tone, respectively (average accuracy: 64%). HCAs had an identical average accuracy of 64%. All participants (100%) were able to correctly identify the squeeze test. For doctors, no correlation was found between confidence in assessing anal tone using DRE and a correct result. Seventy-one percent had received previous training in DRE, with 64% of these taught how to assess anal tone. Forty-three percent of doctors thought that further training would be beneficial. Conclusion. The results demonstrate that accuracy in assessing anal tone using DRE is limited, with overall correctness of 64%. Poor correlation exists between perceived level of skill and study result. Doctors were not significantly more able than HCAs to detect correct tone. Therefore, DRE for the assessment of anal tone is not a wholly accurate tool. A squeeze test may be of greater value if interpreted correctly. Level of Evidence: 4