QZQida Zhang

Qida Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Qida Zhang has a total of 24 co-authors. Here are the top co-authors by number of shared publications:

  • Zhongmin Jin

    Tribology Research Institute, School of Mechanical Engineering, Southwest Jiaotong University, Chengdu, China

    8 shared publications
  • Zhenxian Chen

    Key Laboratory of Road Construction Technology and Equipment of MOE, Chang’an University, Xi’an, China

    6 shared publications
  • Yinghu Peng

    CAS Key Laboratory of Human-Machine Intelligence-Synergy Systems, Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences, Shenzhen, China

    5 shared publications
  • Jiayu Hu

    State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, No.28, Xianning West Road, Xi'an, 710049, China

    3 shared publications
  • Zhenxian Chen

    Key Laboratory of Road Construction Technology and Equipment (Ministry of Education), School of Mechanical Engineering, Chang’an University, Xi’an, China

    3 shared publications
  • Jing Zhang

    State Key Laboratory for Manufacturing System Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, No.28, Xianning West Road, Xi'an, 710049, China

    2 shared publications

Latest Publications

  • Open Access

    Failure analysis and design improvement of retrieved plates from revision surgery

    by Ning-Ze Zhang, Yang-Yang Shui, Qi-Da Zhang, Yuan-Tao Zhang, Jian Su, Ling Qin, Cheng-Kung Cheng


  • Open Access

    Prediction of knee biomechanics with different tibial component malrotations after total knee arthroplasty: conventional machine learning vs. deep learning

    by Qida Zhang, Zhuhuan Li, Zhenxian Chen, Yinghu Peng, Zhongmin Jin, Ling Qin

    The precise alignment of tibiofemoral components in total knee arthroplasty is a crucial factor in enhancing the longevity and functionality of the knee. However, it is a substantial challenge to quickly predict the biomechanical response to malrotation of tibiofemoral components after total knee arthroplasty using musculoskeletal multibody dynamics models. The objective of the present study was to conduct a comparative analysis between a deep learning method and four conventional machine learning methods for predicting knee biomechanics with different tibial component malrotation during a walking gait after total knee arthroplasty. First, the knee contact forces and kinematics with different tibial component malrotation in the range of ±5° in the three directions of anterior/posterior slope, internal/external rotation, and varus/valgus rotation during a walking gait after total knee arthroplasty were calculated based on the developed musculoskeletal multibody dynamics model. Subsequently, deep learning and four conventional machine learning methods were developed using the above 343 sets of biomechanical data as the dataset. Finally, the results predicted by the deep learning method were compared to the results predicted by four conventional machine learning methods. The findings indicated that the deep learning method was more accurate than four conventional machine learning methods in predicting knee contact forces and kinematics with different tibial component malrotation during a walking gait after total knee arthroplasty. The deep learning method developed in this study enabled quickly determine the biomechanical response with different tibial component malrotation during a walking gait after total knee arthroplasty. The proposed method offered surgeons and surgical robots the ability to establish a calibration safety zone, which was essential for achieving precise alignment in both preoperative surgical planning and intraoperative robotic-assisted surgical navigation.


  • Patient-specific musculoskeletal models as a framework for comparing ACL function in unicompartmental versus bicruciate retaining arthroplasty

    by Qida Zhang, Zhenxian Chen, Zhongmin Jin, Orhun K Muratoglu, Kartik M Varadarajan

    Unicompartmental knee arthroplasty has been shown to provide superior functional outcomes compared to total knee arthroplasty and have motivated development of advanced implant designs including bicruciate retaining knee arthroplasty. However, few validated frameworks are available to directly compare the effect of implant design and surgical techniques on ligament function and joint kinematics. In the present study, the subject-specific lower extremity models were developed based on musculoskeletal modeling framework using force-dependent kinematics method, and validated against in vivo telemetric data. The experiment data of two subjects who underwent TKA were obtained from the SimTK “Grand Challenge Competition” repository, and integrated into the subject-specific lower extremity model. Five walking gait trials and three different knee implant models for each subject were used as partial inputs for the model to predict knee biomechanics for unicompartmental, bicruciate retaining, and total knee arthroplasty. The results showed no significant differences in the tibiofemoral contact forces or angular kinematic parameters between three groups. However, unicompartmental knee arthroplasty demonstrated significantly more posterior tibial location between 0% and 40% of the gait cycle (p < 0.017). Significant differences in range of tibiofemoral anterior/posterior translation and medial/lateral translation were also observed between unicompartmental and bicruciate retaining arthroplasty (p < 0.017). Peak values of anterior cruciate ligament forces differed between unicompartmental and bicruciate retaining arthroplasty from 10% to 30% of the gait cycle. Findings of this study indicate that unicompartmental and bicruciate retaining arthroplasty do not have identical biomechanics and point to the complementary role of anterior cruciate ligament and articular geometry in guiding knee function. Further, the patient-specific musculoskeletal model developed provides a reliable framework for assessing new implant designs, and effect of surgical techniques on knee biomechanics following arthroplasty.


  • Leveraging subject-specific musculoskeletal modeling to assess effect of anterior cruciate ligament retaining total knee arthroplasty during walking gait

    by Qida Zhang, Zhenxian Chen, Zhifeng Zhang, Zhongmin Jin, Orhun K Muratoglu, Kartik M Varadarajan

    Bi-cruciate retaining total knee arthroplasty has several potential advantages including improved anteroposterior knee stability compared to contemporary posterior cruciate-retaining total knee arthroplasty. However, few studies have explored whether there is significant differences of knee biomechanics following bi-cruciate retaining total knee arthroplasty compared to posterior cruciate-retaining total knee arthroplasty. In the present study, subject-specific lower extremity musculoskeletal multi-body dynamics models for bi-cruciate retaining, bi-cruciate retaining without anterior cruciate ligament, and posterior cruciate-retaining total knee arthroplasty were developed based on the musculoskeletal modeling framework using force-dependent kinematics method and validated against in vivo telemetric data. The experiment data of two subjects who underwent total knee arthroplasty were obtained for the SimTK “Grand Challenge Competition” repository, and integrated into the musculoskeletal model. Five walking gait trials for each subject were used as partial inputs for the model to predict the knee biomechanics for bi-cruciate retaining, bi-cruciate retaining without anterior cruciate ligament, and posterior cruciate-retaining total knee arthroplasty. The results revealed significantly greater range of anterior/posterior tibiofemoral translation, and significantly more posterior tibial location during the early phase of gait and more anterior tibial location during the late phase of gait were found in bi-cruciate retaining total knee arthroplasty without anterior cruciate ligament when compared to the bi-cruciate retaining total knee arthroplasty. No significant differences in tibiofemoral contact forces, rotations, translations, and ligament forces between bi-cruciate retaining and posterior cruciate-retaining total knee arthroplasty during normal walking gait, albeit slight differences in range of tibiofemoral internal/external rotation and anterior/posterior translation were observed. The present study revealed that anterior cruciate ligament retention has a positive effect on restoring normal knee kinematics in bi-cruciate retaining total knee arthroplasty. Preservation of anterior cruciate ligament in total knee arthroplasty and knee implant designs interplay each other and both contribute to restoring normal knee kinematics in different types of total knee arthroplasty. Further evaluation of more demanding activities and subject data from patients with bi-cruciate retaining and posterior cruciate-retaining total knee arthroplasty via musculoskeletal modeling may better highlight the role of the anterior cruciate ligament and its stabilizing influence.


  • Insert conformity variation affects kinematics and wear performance of total knee replacements

    by Qida Zhang, Zhenxian Chen, Jing Zhang, Jiayu Hu, Yinghu Peng, Xunjian Fan, Zhongmin Jin


  • The role of menisci in knee contact mechanics and secondary kinematics during human walking

    by Jiayu Hu, Hua Xin, Zhenxian Chen, Qida Zhang, Yinghu Peng, Zhongmin Jin


  • Biomechanics and wear comparison between mechanical and kinematic alignments in total knee arthroplasty

    by Zhenxian Chen, Yongchang Gao, Shibin Chen, Qida Zhang, Zhifeng Zhang, Jing Zhang, Xuan Zhang, Zhongmin Jin

    The uses of mechanical and kinematic alignments in total knee arthroplasty are under debate in recent clinical investigations. In this study, the differences in short-term biomechanics and long-term wear volume between mechanical and kinematic alignments in total knee arthroplasty were investigated, based on a subject-specific musculoskeletal multi-body dynamics model during walking gait simulation. An increase of 8.2% in the peak tibiofemoral medial contact force, a posterior contact translation by maximum 4.7 mm and a decrease of 5.5% in the wear volume after a 10-million-cycle simulation were predicted in the kinematic alignment, compared with the mechanical alignment. Nevertheless, the tibiofemoral contact mechanics, the range of motions and the long-term wear were not markedly different between mechanical and kinematic alignments. Furthermore, the mechanical alignment with a posterior tibial slope similar to that under the kinematic alignment was found to produce similar anterior–posterior translation and the range of motion, and an approximate wear volume, compared with the kinematic alignment. The ligament forces under the kinematic alignment were influenced markedly by as much as 25%, 50% and 77% for the medial collateral ligament, lateral collateral ligament and posterior cruciate ligament forces, respectively. And, a maximum increase of 40% for patellofemoral contact force was predicted under the kinematic alignment. These findings suggest that the kinematic alignment is an alternative alignment principle but no marked advantages in biomechanics and wear to the mechanical alignment. The adverse effects of the kinematic alignment on patella loading and soft tissue forces should be noticed.


  • Musculoskeletal multibody dynamics simulation of the contact mechanics and kinematics of a natural knee joint during a walking cycle

    by Jiayu Hu, Zhenxian Chen, Hua Xin, Qida Zhang, Zhongmin Jin

    Detailed knowledge of the in vivo loading and kinematics in the knee joint is essential to understand its normal functions and the aetiology of osteoarthritis. Computer models provide a viable non-invasive solution for estimating joint loading and kinematics during different physiological activities. However, the joint loading and kinematics of the tibiofemoral and patellofemoral joints during a gait cycle were not typically investigated concurrently in previous computational simulations. In this study, a natural knee architecture was incorporated into a lower extremity musculoskeletal multibody dynamics model based on a force-dependent kinematics approach to investigate the contact mechanics and kinematics of a natural knee joint during a walking cycle. Specifically, the contact forces between the femoral/tibial articular cartilages and menisci and between the femoral and tibial/patellar articular cartilages were quantified. The contact forces and kinematics of the tibiofemoral and patellofemoral joints and the muscle activations and ligament forces were predicted simultaneously with a reasonable level of accuracy. The developed musculoskeletal multibody dynamics model with a natural knee architecture can serve as a potential platform for assisting clinical decision-making and postoperative rehabilitation planning.