Ricardo Meurer Papaléo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Ricardo Meurer Papaléo has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Christina Trautmann
GSI Helmholtz Centre for Heavy Ion Research
5 shared publications - Luiz Gustavo Barbosa
IFRS - Campus Erechim
3 shared publications - Pedro Luis Grande
Universidade Federal do Rio Grande do Sul (UFRGS)
3 shared publications D. Severin
Materials Research, GSI Helmholtz Centre, Planckstr. 1, 64291 Darmstadt, Germany
2 shared publications- Eduardo Marcial Bringa
Universidad de Mendoza
2 shared publications - Jonder Morais
Universidade Federal do Rio Grande do Sul CP 15051
2 shared publications
Latest Publications
- Open Access
- 9 September 2026
- Published by MDPI AG in Microplastics
- Vol. 5 (3) , 178
PMMA Microplastics Induce Sublethal Cardiovascular and Developmental Effects During Early Development of Zebrafish (Danio rerio)
Microplastics are increasingly recognized as emerging contaminants with potential toxicological effects on aquatic organisms. Among widely used industrial polymers, poly(methyl methacrylate) (PMMA) has been detected in environmental matrices, raising concerns regarding its biological impacts. This study evaluated the developmental toxicity of 40 µm spherical PMMA microplastics in zebrafish (Danio rerio) using a standardized early-life stage exposure (3 hpf–6 dpf). Before exposure, particles were physicochemically characterized by Fourier Transform Infrared Spectroscopy (FTIR), Field Emission Scanning Electron Microscopy (FESEM), and micro-Raman spectroscopy (µRaman). Embryos were exposed to nominal concentrations ranging from 0.5 to 20 mg/L, and endpoints including survival, hatching rate, spontaneous movements, heart rate, morphology, and locomotor activity were assessed. PMMA exposure did not induce significant mortality or morphological abnormalities at any tested concentration. However, significant sublethal effects were observed, including accelerated hatching at 20 mg/L and increased heart rate across exposure groups, further supported by a positive concentration–response trend across vessel-level values, indicating altered developmental timing and cardiovascular function. These findings demonstrate that PMMA microplastics, despite low acute toxicity, can induce early physiological disturbances in a vertebrate model. The results highlight the importance of incorporating sensitive functional endpoints into hazard assessment frameworks and contribute to a more comprehensive evaluation of the environmental risks associated with microplastics traditionally considered to have low intrinsic reactivity.
- 9 September 2026
- Published by MDPI AG in Microplastics
- Vol. 5 (3) , 178
Open AccessPMMA Microplastics Induce Sublethal Cardiovascular and Developmental Effects During Early Development of Zebrafish (Danio rerio)
Microplastics are increasingly recognized as emerging contaminants with potential toxicological effects on aquatic organisms. Among widely used industrial polymers, poly(methyl methacrylate) (PMMA) has been detected in environmental matrices, raising concerns regarding its biological impacts. This study evaluated the developmental toxicity of 40 µm spherical PMMA microplastics in zebrafish (Danio rerio) using a standardized early-life stage exposure (3 hpf–6 dpf). Before exposure, particles were physicochemically characterized by Fourier Transform Infrared Spectroscopy (FTIR), Field Emission Scanning Electron Microscopy (FESEM), and micro-Raman spectroscopy (µRaman). Embryos were exposed to nominal concentrations ranging from 0.5 to 20 mg/L, and endpoints including survival, hatching rate, spontaneous movements, heart rate, morphology, and locomotor activity were assessed. PMMA exposure did not induce significant mortality or morphological abnormalities at any tested concentration. However, significant sublethal effects were observed, including accelerated hatching at 20 mg/L and increased heart rate across exposure groups, further supported by a positive concentration–response trend across vessel-level values, indicating altered developmental timing and cardiovascular function. These findings demonstrate that PMMA microplastics, despite low acute toxicity, can induce early physiological disturbances in a vertebrate model. The results highlight the importance of incorporating sensitive functional endpoints into hazard assessment frameworks and contribute to a more comprehensive evaluation of the environmental risks associated with microplastics traditionally considered to have low intrinsic reactivity.
- Open Access
- 2 July 2025
- Published by MDPI AG in Preprints.org
An Experimental Study on Processing Parameters of Nanostructured Patterns in PMMA Thin Films by Scanning Probe Lithography
In this work, reproducible routines were established for the processing of regular submi-cron-scale patterns in polymeric thin films using scanning probe lithography (one of the operating modes of a scanning probe microscope – SPM). Silicon probes were used to make the hole arrays in dynamic plowing mode. Afterwards, the tip was changed to view the arrays in intermittent contact mode. The routines were applied to PMMA thin films of different thicknesses, deposited by spin coating, optimizing this parameter for the for-mation of arrays in form of hole grid. The diameter and depth of the holes and also the height and width of the deformations to its outskirts were investigated as a function of the interaction force and the probe action time, as well of the thickness of polymer films.
- 2 July 2025
- Published by MDPI AG in Preprints.org
Open AccessAn Experimental Study on Processing Parameters of Nanostructured Patterns in PMMA Thin Films by Scanning Probe Lithography
In this work, reproducible routines were established for the processing of regular submi-cron-scale patterns in polymeric thin films using scanning probe lithography (one of the operating modes of a scanning probe microscope – SPM). Silicon probes were used to make the hole arrays in dynamic plowing mode. Afterwards, the tip was changed to view the arrays in intermittent contact mode. The routines were applied to PMMA thin films of different thicknesses, deposited by spin coating, optimizing this parameter for the for-mation of arrays in form of hole grid. The diameter and depth of the holes and also the height and width of the deformations to its outskirts were investigated as a function of the interaction force and the probe action time, as well of the thickness of polymer films.
- 20 June 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (6) , 1-7
Evaluating the impact of sample preparation protocol on the elemental analysis of glioblastoma cells with micro-PIXE
- 20 June 2025
- Published by Springer Nature in The European Physical Journal Plus
- Vol. 140 (6) , 1-7
Evaluating the impact of sample preparation protocol on the elemental analysis of glioblastoma cells with micro-PIXE
- Open Access
Thinning of Poly(methyl methacrylate) and Poly(vinyl chloride) Thin Films Induced by High-Energy Ions of Different Stopping Powers
Ion bombardment is an important tool of materials processing, but usually leads to erosion of the surface and significant thickness reductions when thin layers are used. The growing use of polymer thin films in a variety of applications, from coatings and membranes to biomedical and electronic devices, calls for a deeper understanding of the thinning process induced by energetic ions espe-cially for very thin films. Here, thinning and surface morphology changes induced by high-energy ion bombardment in PMMA and PVC thin films were investigated, focusing on the role of the initial thickness of the films and the stopping power of the ions. We used thin films with initial thicknesses varying from 13 to 800 nm, and light and heavy ions as projectiles in the energy range of 2–2000 MeV, where the electronic stopping dominates. Thickness reductions as a function of fluence were monitored and thinning cross sections were extracted from curves. A supralinear scaling between the thinning cross sections and the electronic stopping power of the beams was observed, with a much enhanced thinning efficiency for the swift heavy ions. The scaling with the stopping power dE/dx is almost independent of the initial thickness of the films. At intermediate and large fluences, changes in the physicochemical properties of the irradiated polymers may modulate and decelerate the thinning process of the remaining film. The importance of this secondary process depends on the stopping power and the balance between erosion and the chemical transformations induced by the beam. We also observe a trend for the thinning efficiency to become larger in very thin films. Depending on the type of beam and polymer, this effect is more or less pronounced. PMMA films irradiated with 2 MeV H+ show the most systematic correlation between initial thickness and thinning cross sections, while in PVC films the initial thickness plays a minor role for all investigated beams.
Open AccessThinning of Poly(methyl methacrylate) and Poly(vinyl chloride) Thin Films Induced by High-Energy Ions of Different Stopping Powers
Ion bombardment is an important tool of materials processing, but usually leads to erosion of the surface and significant thickness reductions when thin layers are used. The growing use of polymer thin films in a variety of applications, from coatings and membranes to biomedical and electronic devices, calls for a deeper understanding of the thinning process induced by energetic ions espe-cially for very thin films. Here, thinning and surface morphology changes induced by high-energy ion bombardment in PMMA and PVC thin films were investigated, focusing on the role of the initial thickness of the films and the stopping power of the ions. We used thin films with initial thicknesses varying from 13 to 800 nm, and light and heavy ions as projectiles in the energy range of 2–2000 MeV, where the electronic stopping dominates. Thickness reductions as a function of fluence were monitored and thinning cross sections were extracted from curves. A supralinear scaling between the thinning cross sections and the electronic stopping power of the beams was observed, with a much enhanced thinning efficiency for the swift heavy ions. The scaling with the stopping power dE/dx is almost independent of the initial thickness of the films. At intermediate and large fluences, changes in the physicochemical properties of the irradiated polymers may modulate and decelerate the thinning process of the remaining film. The importance of this secondary process depends on the stopping power and the balance between erosion and the chemical transformations induced by the beam. We also observe a trend for the thinning efficiency to become larger in very thin films. Depending on the type of beam and polymer, this effect is more or less pronounced. PMMA films irradiated with 2 MeV H+ show the most systematic correlation between initial thickness and thinning cross sections, while in PVC films the initial thickness plays a minor role for all investigated beams.
- Open Access
- 20 December 2022
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 10 (4) , 1-15
Dose sensitivity of MAGIC-f polymer gel using different MRI sequences
This study aims to evaluate the dose sensitivity of MAGIC-f gel irradiated by high-energy photon beams, comparing quantification using different MRI sequences. Irradiation was performed using 6 MV photons with 600 cGy/min dose rate, field size of 20x20 cm², and 94 cm source-to-surface distance. Two gel batches were produced on different days and placed in vials. In the first batch, doses of 0, 2, 4, 6, 8, 10, 20, and 40 Gy were planned. The second batch was irradiated with doses of 0, 2, 4, 6, 10, 12, 14, and 16 Gy. MR images were acquired with Spin Echo (SE, TR=3 s) and Multi Spin Echo (MSE, TR = 3s or 10s, turbo factor 24) sequences. The dose is assessed via changes in the transverse relaxation time in the irradiated gel. In MSE, dose sensitivity in the first batch was 0.27 (TR=3 s) and 0.28 Gy-1s-1 (TR=10 s) and in the second batch, 0.31 and 0.31 Gy-1s-1 (TR = 3 s and TR = 10 s, respectively). In the SE sequence, dose sensitivity was 0.42 for the first batch and 0.43 Gy-1s-1 for the second batch. Linearity of dose-response was only obtained for doses below 10 Gy. Comparing the dose sensitivity extracted from MSE and SE sequences using TR= 3s, differences around 30% were found. Thus, although MSE-MRI offers a faster protocol of imaging acquisition it is less precise for quantification of relaxation times, as TE is not a well-defined quantity. The performance of the gel as a dosimeter is consequently sequence dependent.
- 20 December 2022
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 10 (4) , 1-15
Open AccessDose sensitivity of MAGIC-f polymer gel using different MRI sequences
This study aims to evaluate the dose sensitivity of MAGIC-f gel irradiated by high-energy photon beams, comparing quantification using different MRI sequences. Irradiation was performed using 6 MV photons with 600 cGy/min dose rate, field size of 20x20 cm², and 94 cm source-to-surface distance. Two gel batches were produced on different days and placed in vials. In the first batch, doses of 0, 2, 4, 6, 8, 10, 20, and 40 Gy were planned. The second batch was irradiated with doses of 0, 2, 4, 6, 10, 12, 14, and 16 Gy. MR images were acquired with Spin Echo (SE, TR=3 s) and Multi Spin Echo (MSE, TR = 3s or 10s, turbo factor 24) sequences. The dose is assessed via changes in the transverse relaxation time in the irradiated gel. In MSE, dose sensitivity in the first batch was 0.27 (TR=3 s) and 0.28 Gy-1s-1 (TR=10 s) and in the second batch, 0.31 and 0.31 Gy-1s-1 (TR = 3 s and TR = 10 s, respectively). In the SE sequence, dose sensitivity was 0.42 for the first batch and 0.43 Gy-1s-1 for the second batch. Linearity of dose-response was only obtained for doses below 10 Gy. Comparing the dose sensitivity extracted from MSE and SE sequences using TR= 3s, differences around 30% were found. Thus, although MSE-MRI offers a faster protocol of imaging acquisition it is less precise for quantification of relaxation times, as TE is not a well-defined quantity. The performance of the gel as a dosimeter is consequently sequence dependent.
- Open Access
Cratering Induced by Slow Highly Charged Ions on Ultrathin PMMA Films
Highly charged ions are a well-known tool for the nanostructuring of surfaces. We report on the thickness dependence of nanostructures produced by single 260 keV Xe38+ ions on ultrathin poly(methyl methacrylate) (PMMA) films (1 nm to 60 nm) deposited onto Si substrates. The nanostructures induced by slow highly charged ions are rimless craters with a diameter of around 15 nm, which are roughly independent of the thickness of the films down to layers of about 2 nm. The crater depth and thus the overall crater volume are, however, thickness-dependent, decreasing in size in films thinner than ~25 nm. Our findings indicate that although the potential energy of the highly charged ions is the predominant source of deposited energy, the depth of the excited material contributing to crater formation is much larger than the neutralization depth of the ions, which occurs in the first nanometer of the solid at the projectile velocity employed here. This suggests synergism between kinetic and potential-driven processes in nanostructure formation in PMMA.
Open AccessCratering Induced by Slow Highly Charged Ions on Ultrathin PMMA Films
Highly charged ions are a well-known tool for the nanostructuring of surfaces. We report on the thickness dependence of nanostructures produced by single 260 keV Xe38+ ions on ultrathin poly(methyl methacrylate) (PMMA) films (1 nm to 60 nm) deposited onto Si substrates. The nanostructures induced by slow highly charged ions are rimless craters with a diameter of around 15 nm, which are roughly independent of the thickness of the films down to layers of about 2 nm. The crater depth and thus the overall crater volume are, however, thickness-dependent, decreasing in size in films thinner than ~25 nm. Our findings indicate that although the potential energy of the highly charged ions is the predominant source of deposited energy, the depth of the excited material contributing to crater formation is much larger than the neutralization depth of the ions, which occurs in the first nanometer of the solid at the projectile velocity employed here. This suggests synergism between kinetic and potential-driven processes in nanostructure formation in PMMA.
- 7 March 2022
- Published by Elsevier in Neuroscience
- Vol. 497, 271-281
Nanoscale Structural Characterization and Impact on Long-term memory of Amyloid-β42 Oligomeric forms in Zebrafish
- 7 March 2022
- Published by Elsevier in Neuroscience
- Vol. 497, 271-281
Nanoscale Structural Characterization and Impact on Long-term memory of Amyloid-β42 Oligomeric forms in Zebrafish
- Open Access
Impact Features Induced by Single Fast Ions of Different Charge-State on Muscovite Mica
The influence of the charge state q on surface modifications induced by the impact of individual fast, heavy ions on muscovite mica was investigated. Beams of 593 MeV Au with well-defined initial charge states over a relatively broad range of values (30 to 51) and at different irradiation geometries were used. At normal incidence, the impact features are rounded protrusions (hillocks) with ≳20 nm in diameter. At grazing angles, besides the hillocks, craters and elongated tails (up to 350 nm-long) extending along the direction of ion penetration are produced. It is shown that the impact features at normal incidence depend strongly on the initial charge state of the projectiles. This dependence is very weak at grazing angles as the ion reaches the equilibrium charge state closer to the surface. At normal ion incidence, the hillock volume scales with . This dependence stems largely from the increase in the hillock height, as a weak dependence of the diameter was observed.Open AccessImpact Features Induced by Single Fast Ions of Different Charge-State on Muscovite Mica
The influence of the charge state q on surface modifications induced by the impact of individual fast, heavy ions on muscovite mica was investigated. Beams of 593 MeV Au with well-defined initial charge states over a relatively broad range of values (30 to 51) and at different irradiation geometries were used. At normal incidence, the impact features are rounded protrusions (hillocks) with ≳20 nm in diameter. At grazing angles, besides the hillocks, craters and elongated tails (up to 350 nm-long) extending along the direction of ion penetration are produced. It is shown that the impact features at normal incidence depend strongly on the initial charge state of the projectiles. This dependence is very weak at grazing angles as the ion reaches the equilibrium charge state closer to the surface. At normal ion incidence, the hillock volume scales with . This dependence stems largely from the increase in the hillock height, as a weak dependence of the diameter was observed. - Open Access
- 1 September 2019
- Published by Revista Brasileira de Fisica Medica in Revista Brasileira de Física Médica
- Vol. 13 (1) , 14-23
Ultrassonografia: Princípios Físicos e Controle da Qualidade
Neste artigo fazemos uma breve revisão da ultrassonografia na perspectiva da física médica. Iniciamos apresentando uma visão resumida dos princípios físicos mais fundamentais em imagens por ultrassom e alguns parâmetros importantes na aferição da qualidade de imagem e do desempenho geral dos ecógrafos que derivam desses princípios. Na segunda parte, apresentamos uma contextualização histórica do controle da qualidade (CQ) em ultrassonografia na prática profissional da física médica e as dificuldades associadas à falta de legislação governamental e à contínua evolução da tecnológica. Esforços para sistematizar e implementar protocolos de CQ para ultrassonografia no Brasil são feitos há mais de 20 anos. Porém, que nível de inserção nesse mercado tão amplo foi atingido pelos serviços e empresas de física médica desde então? Fazemos uma breve reflexão sobre essa questão a partir da experiência no estado do Rio Grande do Sul, buscando, ao final, extrapolar para o cenário nacional e avaliar as perspectivas futuras do CQ no mercado da física médica.
- 1 September 2019
- Published by Revista Brasileira de Fisica Medica in Revista Brasileira de Física Médica
- Vol. 13 (1) , 14-23
Open AccessUltrassonografia: Princípios Físicos e Controle da Qualidade
Neste artigo fazemos uma breve revisão da ultrassonografia na perspectiva da física médica. Iniciamos apresentando uma visão resumida dos princípios físicos mais fundamentais em imagens por ultrassom e alguns parâmetros importantes na aferição da qualidade de imagem e do desempenho geral dos ecógrafos que derivam desses princípios. Na segunda parte, apresentamos uma contextualização histórica do controle da qualidade (CQ) em ultrassonografia na prática profissional da física médica e as dificuldades associadas à falta de legislação governamental e à contínua evolução da tecnológica. Esforços para sistematizar e implementar protocolos de CQ para ultrassonografia no Brasil são feitos há mais de 20 anos. Porém, que nível de inserção nesse mercado tão amplo foi atingido pelos serviços e empresas de física médica desde então? Fazemos uma breve reflexão sobre essa questão a partir da experiência no estado do Rio Grande do Sul, buscando, ao final, extrapolar para o cenário nacional e avaliar as perspectivas futuras do CQ no mercado da física médica.