Renata Rodrigues de Almeida-Pedrin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Renata Rodrigues de Almeida-Pedrin has a total of 120 co-authors. Here are the top co-authors by number of shared publications:
- Ana Cláudia de Castro Ferreira Conti
Universidade de São Paulo
31 shared publications - Marcio Rodrigues de Almeida
Department of Orthodontics University of Anhanguera‐Uniderp Campo Grande Brazil
22 shared publications - Paula Vanessa Pedron Oltramari
Department of Orthodontics University of Anhanguera‐Uniderp Campo Grande Brazil
16 shared publications - Thais Maria Freire Fernandes
Department of Orthodontics School of Dentistry Uniderp Campo Grande Mato Grosso do Sul Brazil
16 shared publications - Victor de Miranda Ladewig
Unopar, Programa de Pós-Graduação Stricto Sensu em Odontologia. PR, Brasil
10 shared publications Renato Rodrigues de Almeida
Department of Orthodontics, Bauru School of Dentistry, University of São Paulo, Bauru, SP, Brazil
8 shared publications
Latest Publications
- Open Access
- 22 October 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Impact of Facial Pattern and Smile Arc on the Perception of Male Facial Attractiveness
Objective: To investigate how variations in smile arc and facial pattern influence the perception of male facial attractiveness. Materials and Methods: Nine standardized frontal photographs of a male model were digitally modified to generate three smile arc configurations (consonant, straight, and inverted) and three facial patterns (brachyfacial, mesofacial, and dolichofacial). A total of 134 evaluators (67 laypersons and 67 orthodontists) rated the images using a 5‐point Likert scale. Data were analyzed using cumulative link mixed models (CLMM), incorporating evaluator category, sex, smile arc type, and facial pattern as fixed effects, with evaluator ID as a random intercept. Results: The consonant smile arc consistently received the highest attractiveness scores, whereas the inverted smile produced the most pronounced negative impact. The mesofacial pattern was rated more favorably than the brachyfacial pattern. A significant interaction was observed between smile arc, facial pattern, and presentation format, indicating that evaluators' perceptions were modulated by the combined esthetic cues. Conclusion: Smile arc morphology and facial pattern exert meaningful influence on perceived facial attractiveness. The inverted smile arc was associated with the lowest aesthetic ratings, while the mesofacial pattern achieved the most favorable evaluations. The interaction between these variables highlights the importance of integrating both facial pattern and smile arc characteristics when planning aesthetic interventions.
- 22 October 2026
- Published by Wiley in Journal of Esthetic and Restorative Dentistry
Open AccessImpact of Facial Pattern and Smile Arc on the Perception of Male Facial Attractiveness
Objective: To investigate how variations in smile arc and facial pattern influence the perception of male facial attractiveness. Materials and Methods: Nine standardized frontal photographs of a male model were digitally modified to generate three smile arc configurations (consonant, straight, and inverted) and three facial patterns (brachyfacial, mesofacial, and dolichofacial). A total of 134 evaluators (67 laypersons and 67 orthodontists) rated the images using a 5‐point Likert scale. Data were analyzed using cumulative link mixed models (CLMM), incorporating evaluator category, sex, smile arc type, and facial pattern as fixed effects, with evaluator ID as a random intercept. Results: The consonant smile arc consistently received the highest attractiveness scores, whereas the inverted smile produced the most pronounced negative impact. The mesofacial pattern was rated more favorably than the brachyfacial pattern. A significant interaction was observed between smile arc, facial pattern, and presentation format, indicating that evaluators' perceptions were modulated by the combined esthetic cues. Conclusion: Smile arc morphology and facial pattern exert meaningful influence on perceived facial attractiveness. The inverted smile arc was associated with the lowest aesthetic ratings, while the mesofacial pattern achieved the most favorable evaluations. The interaction between these variables highlights the importance of integrating both facial pattern and smile arc characteristics when planning aesthetic interventions.
- 1 May 2026
- Published by Wiley in Special Care in Dentistry
- Vol. 46 (3) , e70196
Comparative Study of Periodontal Status in Patients With and Without Trisomy 21 During Treatment With Clear Aligners
Objective: To assess the periodontal status of patients with trisomy 21 (T21) compared to non‐syndromic patients during orthodontic treatment with clear aligners. Methods: The sample consisted of 30 patients, both gender, aged between 11 and 35 years, divided into two groups: T21 ( n = 10, patients with T21, treated prospectively) and CONTROL ( n = 20, control group, non‐syndromic patients). In both groups, patients were treated with Invisalign clear aligners (AlignTechnology), following the same treatment parameters. Periodontal status was assessed at five timepoints using the Gingival Bleeding Index (GBI) and the Visible Plaque Index (VPI) following the WHO criteria. Data analysis was performed with the aid of the SPSS 23.0 software, using the Shapiro‐Wilk test, chi‐square test, Fisher's exact test, Mann‐Whitney test, ANOVA, and t‐test (α = 0.05). Results: Most participants were male (73.3%) and more than 21 years of age (53.3%). At baseline, the T21 group had greater periodontal pocket depth (0.20 ± 0.42) than the control group (0.00 ± 0.00) ( p = 0.039), but both groups reached a mean of 0.00 after 365 days ( p = 0.006). The T21 group had consistently higher VPI scores, with means of 64.82 ± 16.05 at baseline and 68.35 ± 18.01 at 365 days ( p = 0.000) compared to 19.15 ± 13.93 and 24.61 ± 17.29 in the control group. Conclusion: Aligners have proven to be a suitable orthodontic option for patients T21, without worsening the periodontal condition during treatment.
- 1 May 2026
- Published by Wiley in Special Care in Dentistry
- Vol. 46 (3) , e70196
Comparative Study of Periodontal Status in Patients With and Without Trisomy 21 During Treatment With Clear Aligners
Objective: To assess the periodontal status of patients with trisomy 21 (T21) compared to non‐syndromic patients during orthodontic treatment with clear aligners. Methods: The sample consisted of 30 patients, both gender, aged between 11 and 35 years, divided into two groups: T21 ( n = 10, patients with T21, treated prospectively) and CONTROL ( n = 20, control group, non‐syndromic patients). In both groups, patients were treated with Invisalign clear aligners (AlignTechnology), following the same treatment parameters. Periodontal status was assessed at five timepoints using the Gingival Bleeding Index (GBI) and the Visible Plaque Index (VPI) following the WHO criteria. Data analysis was performed with the aid of the SPSS 23.0 software, using the Shapiro‐Wilk test, chi‐square test, Fisher's exact test, Mann‐Whitney test, ANOVA, and t‐test (α = 0.05). Results: Most participants were male (73.3%) and more than 21 years of age (53.3%). At baseline, the T21 group had greater periodontal pocket depth (0.20 ± 0.42) than the control group (0.00 ± 0.00) ( p = 0.039), but both groups reached a mean of 0.00 after 365 days ( p = 0.006). The T21 group had consistently higher VPI scores, with means of 64.82 ± 16.05 at baseline and 68.35 ± 18.01 at 365 days ( p = 0.000) compared to 19.15 ± 13.93 and 24.61 ± 17.29 in the control group. Conclusion: Aligners have proven to be a suitable orthodontic option for patients T21, without worsening the periodontal condition during treatment.
- Open Access
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 34
Evaluation of dimensional changes in dental arches after maxillary expansion: a comparative study between Invisalign® first and Hyrax appliances in the mixed dentition
Objective This clinical study aimed to compare the outcomes of maxillary expansion using Invisalign® aligners and hyrax expanders in mixed dentition. Methodology Overall, 35 patients (8.99±1.52 years, 17 males and 18 females) were divided into two groups: patients treated with dentoalveolar expansion appliance using Invisalign® First (IF group, 8.06±0.78 years, 9 males and 5 females) and patients treated with rapid maxillary expansion (RME group, 9.61±1.59 years, 8 males and 13 females). The treatment protocol was the same for all individuals within the same group. Digital dental models were analyzed at pre- (T0) and post-treatment (T1). The mean treatment duration was six months for the RME group and eight months for the IF one. Furthermore, the outcomes were compared to what was planned for the IF group. Arch dimensions were evaluated using digital dental models on OrthoViewer (3Shape, Copenhagen, Denmark). Intergroup comparisons were performed using the Student’s t- or Mann-Whitney tests. Intragroup comparisons were made by the paired t-test. All statistical analyses were performed with a 5% significance level. Results A statistically greater increase in all transverse widths in the cervical points was observed in the RME group. The same result was found for the distance between the cusp tips of permanent first molars. Conclusions Hyrax appliances promoted greater transverse expansion than Invisalign® First in all evaluated regions. Invisalign® First showed greater dentoalveolar effects, with the highest transverse gain observed in the deciduous second molar region and greater discrepancy between cervical and cusp tip measurements.
- 1 January 2026
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 34
Open AccessEvaluation of dimensional changes in dental arches after maxillary expansion: a comparative study between Invisalign® first and Hyrax appliances in the mixed dentition
Objective This clinical study aimed to compare the outcomes of maxillary expansion using Invisalign® aligners and hyrax expanders in mixed dentition. Methodology Overall, 35 patients (8.99±1.52 years, 17 males and 18 females) were divided into two groups: patients treated with dentoalveolar expansion appliance using Invisalign® First (IF group, 8.06±0.78 years, 9 males and 5 females) and patients treated with rapid maxillary expansion (RME group, 9.61±1.59 years, 8 males and 13 females). The treatment protocol was the same for all individuals within the same group. Digital dental models were analyzed at pre- (T0) and post-treatment (T1). The mean treatment duration was six months for the RME group and eight months for the IF one. Furthermore, the outcomes were compared to what was planned for the IF group. Arch dimensions were evaluated using digital dental models on OrthoViewer (3Shape, Copenhagen, Denmark). Intergroup comparisons were performed using the Student’s t- or Mann-Whitney tests. Intragroup comparisons were made by the paired t-test. All statistical analyses were performed with a 5% significance level. Results A statistically greater increase in all transverse widths in the cervical points was observed in the RME group. The same result was found for the distance between the cusp tips of permanent first molars. Conclusions Hyrax appliances promoted greater transverse expansion than Invisalign® First in all evaluated regions. Invisalign® First showed greater dentoalveolar effects, with the highest transverse gain observed in the deciduous second molar region and greater discrepancy between cervical and cusp tip measurements.
- Open Access
- 30 December 2025
- Published by Wiley in Orthodontics & Craniofacial Research
- Vol. 29 (2) , 366-374
Quantifying Root Resorption on the Incisors After Clear Aligner and Fixed Appliance Therapy Using Artificial Intelligence Tool Based CBCT Surface Models: Randomized Clinical Trial
Objective: To quantify external apical root resorption (EARR) on the incisors following non‐extraction treatment of Class I malocclusion patients with moderate crowding, comparing clear aligners and fixed appliances using a novel 3D analysis of Cone‐Beam Computed Tomography (CBCT) derived surface models. Methods: In this randomized clinical trial, 32 adult patients, mean age 22.3 years, mean treatment duration 24.2 months, with Class I malocclusion and moderate crowding (mean Little's Index 4.76 mm) were allocated to either clear aligner ( n = 15) or fixed appliance ( n = 17) treatment. CBCT scans were obtained before and after treatment. EARR was measured using surface‐based analysis of 3D models, and associations with patient and treatment‐related factors were tested. Results: The overall median EARR was −0.72 mm, with no significant difference between clear aligners (−0.71 mm) and fixed appliances (−0.72 mm). Upper lateral incisors exhibited significantly greater EARR than lower incisors ( p = 0.002) and upper central incisors ( p < 0.001). No significant predictor for EARR was found considering age, sex, crowding severity or treatment duration. Conclusions: EARR occurred following non‐extraction treatment of Class I malocclusion with both clear aligners and fixed appliances, with no significant difference between appliance types. Upper lateral incisors were most susceptible to EARR. The novel 3D analysis enabled comprehensive quantification of total EARR, setting a new methodological standard. Monitoring root health during treatment is important, particularly for upper lateral incisors.
- 30 December 2025
- Published by Wiley in Orthodontics & Craniofacial Research
- Vol. 29 (2) , 366-374
Open AccessQuantifying Root Resorption on the Incisors After Clear Aligner and Fixed Appliance Therapy Using Artificial Intelligence Tool Based CBCT Surface Models: Randomized Clinical Trial
Objective: To quantify external apical root resorption (EARR) on the incisors following non‐extraction treatment of Class I malocclusion patients with moderate crowding, comparing clear aligners and fixed appliances using a novel 3D analysis of Cone‐Beam Computed Tomography (CBCT) derived surface models. Methods: In this randomized clinical trial, 32 adult patients, mean age 22.3 years, mean treatment duration 24.2 months, with Class I malocclusion and moderate crowding (mean Little's Index 4.76 mm) were allocated to either clear aligner ( n = 15) or fixed appliance ( n = 17) treatment. CBCT scans were obtained before and after treatment. EARR was measured using surface‐based analysis of 3D models, and associations with patient and treatment‐related factors were tested. Results: The overall median EARR was −0.72 mm, with no significant difference between clear aligners (−0.71 mm) and fixed appliances (−0.72 mm). Upper lateral incisors exhibited significantly greater EARR than lower incisors ( p = 0.002) and upper central incisors ( p < 0.001). No significant predictor for EARR was found considering age, sex, crowding severity or treatment duration. Conclusions: EARR occurred following non‐extraction treatment of Class I malocclusion with both clear aligners and fixed appliances, with no significant difference between appliance types. Upper lateral incisors were most susceptible to EARR. The novel 3D analysis enabled comprehensive quantification of total EARR, setting a new methodological standard. Monitoring root health during treatment is important, particularly for upper lateral incisors.
- 3 April 2025
- Published by Wiley in Orthodontics & Craniofacial Research
- Vol. 28 (4) , 706-712
Do Objective Sleep Metrics and Psychosocial Profiles Differ in the Presence of Possible Awake Bruxism in Patients With Obstructive Sleep Apnea? A Preliminary Polysomnographic Study
Objective: Poor sleep quality and psychosocial impairment are reported to be important aetiological factors for the presence of awake bruxism (AB) although with its absence of certainty. Therefore, this preliminary study aimed to investigate the relation between polysomnography (PSG) objective sleep metrics and psychosocial factors in the presence of possible AB in obstructive sleep apnoea (OSA) individuals. Methods: A cross‐sectional study was conducted with 38 OSA individuals (47.02 ± 15.01 years). All participants underwent in‐laboratory PSG, and objective sleep metrics were analysed. The presence of possible AB was evaluated by the Oral Behaviour Checklist (OBC), and psychosocial factors were assessed using the State–Trait Anxiety Inventory (STAI‐T), Beck Depression Inventory (BDI) and Perceived Stress Scale (PSS). Student's t ‐test and Kolmogorov–Smirnov test were performed for proper comparisons (significance level of 5%). Results: 39.47% (15 individuals) were diagnosed with possible AB. Objective sleep metrics and psychosocial variables did not significantly differ between those with and without possible AB ( p > 0.050). Conclusions: This study elucidates that sleep quality and psychosocial profile seem not to be different regarding possible AB presence when analysed by PSG recording. More studies comparing the subjective and objective sleep parameters and the real role of psychosocial variables in the presence of AB should be performed.
- 3 April 2025
- Published by Wiley in Orthodontics & Craniofacial Research
- Vol. 28 (4) , 706-712
Do Objective Sleep Metrics and Psychosocial Profiles Differ in the Presence of Possible Awake Bruxism in Patients With Obstructive Sleep Apnea? A Preliminary Polysomnographic Study
Objective: Poor sleep quality and psychosocial impairment are reported to be important aetiological factors for the presence of awake bruxism (AB) although with its absence of certainty. Therefore, this preliminary study aimed to investigate the relation between polysomnography (PSG) objective sleep metrics and psychosocial factors in the presence of possible AB in obstructive sleep apnoea (OSA) individuals. Methods: A cross‐sectional study was conducted with 38 OSA individuals (47.02 ± 15.01 years). All participants underwent in‐laboratory PSG, and objective sleep metrics were analysed. The presence of possible AB was evaluated by the Oral Behaviour Checklist (OBC), and psychosocial factors were assessed using the State–Trait Anxiety Inventory (STAI‐T), Beck Depression Inventory (BDI) and Perceived Stress Scale (PSS). Student's t ‐test and Kolmogorov–Smirnov test were performed for proper comparisons (significance level of 5%). Results: 39.47% (15 individuals) were diagnosed with possible AB. Objective sleep metrics and psychosocial variables did not significantly differ between those with and without possible AB ( p > 0.050). Conclusions: This study elucidates that sleep quality and psychosocial profile seem not to be different regarding possible AB presence when analysed by PSG recording. More studies comparing the subjective and objective sleep parameters and the real role of psychosocial variables in the presence of AB should be performed.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 33, e20250179
Patient compliance with braces vs. Invisalign®: a secondary data analysis from a randomized clinical trial
The success of orthodontic treatment depends on several factors that may influence the desired outcome, such as patient motivation and cooperation. Objective: This study compared patient compliance during the first year of orthodontic treatment using aligners and conventional fixed appliances. Methodology: The sample included 39 participants (22.1±4.62 years, 25 males, 14 females) randomized into two groups: orthodontic aligners (OA, 20 patients, 23.7±5.6 years, 12 males, 8 females) and fixed appliances (FA, 19 patients, 20.5±4.5 years, 12 males, 7 females). Patient compliance was measured using the Orthodontic Patient Cooperation Scale (OPCS) composed of 10 questions related to attitudes and attendance of patients in relation to treatment. The questionnaire was applied at three different points: at 3 months (T1), at 6 months (T2), and at 12 months (T3) of treatment. The psychosocial profile of the patients was assessed using the anxiety (IDATE) and stress (PSS-14) questionnaires. Both groups were comparable in age, gender and psychosocial profile. Compliance comparisons between groups at T1, T2 and T3, as well as between genders, were performed using the Mann-Whitney test. Comparison between T1, T2 and T3 were performed using the Friedman test. The correlation between age and compliance scores was assessed using the Spearman's correlation coefficient. The psychosocial profile was analyzed using the Independent t-test. All tests considered p<0.05. Results: The type of appliance (OA or FA) and the time of assessment did not significantly influence patient compliance. The age and gender of patients were not correlated with their degree of compliance. Patient compliance was similar in the first 12 months of treatment, regardless of the protocol used, the patient's gender and age. Conclusions: The level of patient compliance with orthodontic treatment was not influenced by the type of appliance (conventional fixed appliances or aligners), nor by the patient's age or gender.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Journal of Applied Oral Science
- Vol. 33, e20250179
Open AccessPatient compliance with braces vs. Invisalign®: a secondary data analysis from a randomized clinical trial
The success of orthodontic treatment depends on several factors that may influence the desired outcome, such as patient motivation and cooperation. Objective: This study compared patient compliance during the first year of orthodontic treatment using aligners and conventional fixed appliances. Methodology: The sample included 39 participants (22.1±4.62 years, 25 males, 14 females) randomized into two groups: orthodontic aligners (OA, 20 patients, 23.7±5.6 years, 12 males, 8 females) and fixed appliances (FA, 19 patients, 20.5±4.5 years, 12 males, 7 females). Patient compliance was measured using the Orthodontic Patient Cooperation Scale (OPCS) composed of 10 questions related to attitudes and attendance of patients in relation to treatment. The questionnaire was applied at three different points: at 3 months (T1), at 6 months (T2), and at 12 months (T3) of treatment. The psychosocial profile of the patients was assessed using the anxiety (IDATE) and stress (PSS-14) questionnaires. Both groups were comparable in age, gender and psychosocial profile. Compliance comparisons between groups at T1, T2 and T3, as well as between genders, were performed using the Mann-Whitney test. Comparison between T1, T2 and T3 were performed using the Friedman test. The correlation between age and compliance scores was assessed using the Spearman's correlation coefficient. The psychosocial profile was analyzed using the Independent t-test. All tests considered p<0.05. Results: The type of appliance (OA or FA) and the time of assessment did not significantly influence patient compliance. The age and gender of patients were not correlated with their degree of compliance. Patient compliance was similar in the first 12 months of treatment, regardless of the protocol used, the patient's gender and age. Conclusions: The level of patient compliance with orthodontic treatment was not influenced by the type of appliance (conventional fixed appliances or aligners), nor by the patient's age or gender.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 30 (2) , e2524248
Does the need for refinement sets of orthodontic clear aligners correlate with professional experience?
Objective: To assess how often orthodontists request additional aligners and correlate this need with professional’s experience.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 30 (2) , e2524248
Open AccessDoes the need for refinement sets of orthodontic clear aligners correlate with professional experience?
Objective: To assess how often orthodontists request additional aligners and correlate this need with professional’s experience.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 39, e12
Impact of orthodontic treatment with aligners and fixed appliances on OHRQoL: a randomized clinical trial
The aim of this study was to assess the impact of orthodontic treatment with orthodontic aligners (OAs) and fixed appliances (FAs) on oral health-related quality of life (OHRQoL). This parallel randomized clinical trial included 40 male and female patients aged 13 to 35 years diagnosed with Angle’s Class I malocclusion. Participants were assigned to two groups: OA (n = 20) and FA (n = 20). OHRQoL was assessed using the Brazilian OHIP-14, which was administered before treatment (T0), at 1 month (T1), 6 months (T2), and 12 months (T3) after treatment initiation. Data were analyzed using the independent t test, the chi-square test, the Mann-Whitney test, and Friedman test (p < 0.05). FAs had a significantly (p < 0.05) higher impact on OHRQoL at T1 in terms of functional limitation, physical pain, psychological discomfort, physical disability, psychological disability, and overall score. Within-group comparison showed higher scores for the FA group in comparison to the OA group. Functional limitation scores were higher at T1 than at T0 (p = 0.034), while physical pain scores were higher at T1 compared to T0 (p = 0.034) and T2 (p = 0.010). Psychological discomfort scores were higher at T1 than at T2 (p = 0.015). Physical disability scores were higher at T1 compared to T0 (p = 0.008). Overall scores were higher at T1 than at T2 (p = 0.003). No significant changes were observed in the OA within-group comparison. Patients treated with OAs had less impact on OHRQoL compared to those treated with FAs in the first month. There was no difference between the groups at the 6-month follow-up.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Brazilian Oral Research
- Vol. 39, e12
Open AccessImpact of orthodontic treatment with aligners and fixed appliances on OHRQoL: a randomized clinical trial
The aim of this study was to assess the impact of orthodontic treatment with orthodontic aligners (OAs) and fixed appliances (FAs) on oral health-related quality of life (OHRQoL). This parallel randomized clinical trial included 40 male and female patients aged 13 to 35 years diagnosed with Angle’s Class I malocclusion. Participants were assigned to two groups: OA (n = 20) and FA (n = 20). OHRQoL was assessed using the Brazilian OHIP-14, which was administered before treatment (T0), at 1 month (T1), 6 months (T2), and 12 months (T3) after treatment initiation. Data were analyzed using the independent t test, the chi-square test, the Mann-Whitney test, and Friedman test (p < 0.05). FAs had a significantly (p < 0.05) higher impact on OHRQoL at T1 in terms of functional limitation, physical pain, psychological discomfort, physical disability, psychological disability, and overall score. Within-group comparison showed higher scores for the FA group in comparison to the OA group. Functional limitation scores were higher at T1 than at T0 (p = 0.034), while physical pain scores were higher at T1 compared to T0 (p = 0.034) and T2 (p = 0.010). Psychological discomfort scores were higher at T1 than at T2 (p = 0.015). Physical disability scores were higher at T1 compared to T0 (p = 0.008). Overall scores were higher at T1 than at T2 (p = 0.003). No significant changes were observed in the OA within-group comparison. Patients treated with OAs had less impact on OHRQoL compared to those treated with FAs in the first month. There was no difference between the groups at the 6-month follow-up.
- 11 September 2024
- Published by Wiley in Special Care in Dentistry
- Vol. 44 (6) , 1781-1787
Impact of orthodontic treatment with aligners on the oral health‐related quality of life of patients with trisomy 21
Objective: To assess the impact of treatment with orthodontic aligners (OA) on oral health‐related quality of life (OHRQoL) in patients with trisomy 21 (T21) compared to non‐syndromic patients.Materials and methods: The sample consisted of 30 patients, both sexes, aged between 11 and 35 years, divided into two groups: T21 (n = 10, patients with T21, treated prospectively) and CONTROL (n = 20, control group, non‐syndromic patients, from the Orthodontic Laboratory of UNOPAR). In both groups, patients were treated with Invisalign orthodontic aligners (Align Technology), following the same treatment parameters. Participants, assisted by their caregivers, when necessary, answered Oral Health Impact Profile (OHIP‐14) instrument and the patient's guardians answered the Oral Health Scale for People with Down's syndrome (OHDS) instrument, before (T0) and after 30 (T1), 180 (T2), and 365 (T3) days from the start of treatment. Friedman tests with Bonferroni correction and Mann–Whitney tests were used (p < .05).Results: For the OHDS instrument, it was observed that for the eating and communication domains and an overall score, the treatment with OA positively impacted the lives of T21 patients (p < .05). Regarding the OHIP‐14 instrument, the intragroup evaluation showed that in the CONTROL group, there was no significant difference between the evaluated times; while for the T21 group, there was a significant positive impact (p < .05).Conclusion: The results showed that the treatment with aligners positively impacted the OHRQoL of T21 patients, and these results were perceived by caregivers, mainly in relation to issues related to eating and communication.
- 11 September 2024
- Published by Wiley in Special Care in Dentistry
- Vol. 44 (6) , 1781-1787
Impact of orthodontic treatment with aligners on the oral health‐related quality of life of patients with trisomy 21
Objective: To assess the impact of treatment with orthodontic aligners (OA) on oral health‐related quality of life (OHRQoL) in patients with trisomy 21 (T21) compared to non‐syndromic patients.Materials and methods: The sample consisted of 30 patients, both sexes, aged between 11 and 35 years, divided into two groups: T21 (n = 10, patients with T21, treated prospectively) and CONTROL (n = 20, control group, non‐syndromic patients, from the Orthodontic Laboratory of UNOPAR). In both groups, patients were treated with Invisalign orthodontic aligners (Align Technology), following the same treatment parameters. Participants, assisted by their caregivers, when necessary, answered Oral Health Impact Profile (OHIP‐14) instrument and the patient's guardians answered the Oral Health Scale for People with Down's syndrome (OHDS) instrument, before (T0) and after 30 (T1), 180 (T2), and 365 (T3) days from the start of treatment. Friedman tests with Bonferroni correction and Mann–Whitney tests were used (p < .05).Results: For the OHDS instrument, it was observed that for the eating and communication domains and an overall score, the treatment with OA positively impacted the lives of T21 patients (p < .05). Regarding the OHIP‐14 instrument, the intragroup evaluation showed that in the CONTROL group, there was no significant difference between the evaluated times; while for the T21 group, there was a significant positive impact (p < .05).Conclusion: The results showed that the treatment with aligners positively impacted the OHRQoL of T21 patients, and these results were perceived by caregivers, mainly in relation to issues related to eating and communication.
- Open Access
- 27 April 2024
- Published by Uniao Atlantica de Pesquisadores in Concilium
- Vol. 24 (8) , 296-310
The impact of facial pattern on esthetic evaluation of cheek size
This research evaluate the facial esthetic related to cheek size changes in vertical facial patterns. The sample included 18 images of three female models with brachyfacial, mesofacial and dolichofacial patterns. Frontal facial photographs were taken at rest and smiling, and modified simulating bichectomy or cheek augmentation. A total of 76 evaluators were invited, including laypersons (LP) (n=25), professionals with experience in facial harmonization (HOFp) (n=25) and orthodontists (n=26), to judge the attractiveness of the face according to the Likert scale. The Kruskal-Wallis test for the evaluators and the Friedman test for the cheeks changes at a significance level (p<0.05) were used. In the brachyfacial pattern, resting photography with bichectomy simulation was preferred by HOFp and LP. According to LP, there is a tendency to assign higher grades to the brachyfacial smile photo, regardless of the alteration. In the mesofacial pattern, cheek augmentation, original and reduction, at rest and smiling, were similarly evaluated by the 3 groups. In the dolichofacial pattern, LP gave higher scores than orthodontists for all cheek changes in smile photographs. It is concluded that facial esthetic in relation to cheek size in the different vertical facial patterns was assessed differently by orthodontists, HOFp and LP. However, it was not possible to identify a preferred size (original, -6mm or +6mm) for each facial pattern. The clinical relevance of this study is related to the orientation of patients in making decisions about the treatment plan, including aesthetics and multidisciplinarity, considering the facial pattern and the patient's opinion.
- 27 April 2024
- Published by Uniao Atlantica de Pesquisadores in Concilium
- Vol. 24 (8) , 296-310
Open AccessThe impact of facial pattern on esthetic evaluation of cheek size
This research evaluate the facial esthetic related to cheek size changes in vertical facial patterns. The sample included 18 images of three female models with brachyfacial, mesofacial and dolichofacial patterns. Frontal facial photographs were taken at rest and smiling, and modified simulating bichectomy or cheek augmentation. A total of 76 evaluators were invited, including laypersons (LP) (n=25), professionals with experience in facial harmonization (HOFp) (n=25) and orthodontists (n=26), to judge the attractiveness of the face according to the Likert scale. The Kruskal-Wallis test for the evaluators and the Friedman test for the cheeks changes at a significance level (p<0.05) were used. In the brachyfacial pattern, resting photography with bichectomy simulation was preferred by HOFp and LP. According to LP, there is a tendency to assign higher grades to the brachyfacial smile photo, regardless of the alteration. In the mesofacial pattern, cheek augmentation, original and reduction, at rest and smiling, were similarly evaluated by the 3 groups. In the dolichofacial pattern, LP gave higher scores than orthodontists for all cheek changes in smile photographs. It is concluded that facial esthetic in relation to cheek size in the different vertical facial patterns was assessed differently by orthodontists, HOFp and LP. However, it was not possible to identify a preferred size (original, -6mm or +6mm) for each facial pattern. The clinical relevance of this study is related to the orientation of patients in making decisions about the treatment plan, including aesthetics and multidisciplinarity, considering the facial pattern and the patient's opinion.