Xin Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Xin Wei has a total of 136 co-authors. Here are the top co-authors by number of shared publications:
- Mao Chen
Department of Cardiology, West China Hospital, Sichuan University, Chengdu 610041, China
15 shared publications - Yuan Feng
Department of Cardiology, West China Hospital, Sichuan University, Chengdu 610041, China
11 shared publications Xi Li
Department of Cardiology, West China Hospital Sichuan University Chengdu China
10 shared publicationsHong Tang
Department of Cardiology, West China Hospital Sichuan University Chengdu China
8 shared publicationsFei Chen
Department of Cardiology, West China Hospital Sichuan University Chengdu China
7 shared publicationsYujia Liang
Department of Cardiology, West China Hospital Sichuan University Chengdu China
7 shared publications
Latest Publications
- Open Access
- 16 July 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (14) , 5574
Transcatheter Versus Mechanical and Bioprosthetic Surgical Aortic Valve Replacement in Retrospective Patient Cohorts with Aortic Stenosis <75 Years
Background: Comparisons between transcatheter and surgical aortic valve replacement (TAVR or SAVR) in younger aortic stenosis (AS) patients are scarce. The aim of the study was to evaluate the 5-year outcomes of AS patients n = 808) or SAVR (n = 838) were finally included. At baseline, TAVR patients had an older age [(67.9 ± 5.2) vs. (56.5 ± 9.6) years, p < 0.001] and a higher surgical risk score [(3.1 ± 1.5) vs. (2.1 ± 1.0) %, p < 0.001] than SAVR patients, which was well balanced after IPTW. The 5-year adjusted risk of the primary outcome was similar (TAVR 45.9% vs. SAVR 43.4%, weighted hazard ratio, 1.00, 95% confidence interval, 0.64–1.54, p = 0.986), which stayed comparable between TAVR and mechanical or bioprosthetic SAVR separately. In BAV patients (n = 516), the risk of death was 8.3% in the TAVR group and 3.4% in the SAVR group (p = 0.349). The risk of bioprosthetic structural valve deterioration at 5 years was comparable between groups in the overall cohort (5.7% vs. 8.4%, p = 0.478) and BAV patients (7.8% vs. 13.2%, p = 0.345). Conclusions: In this retrospective study of patients aged <75 years, the risk-adjusted 5-year major clinical outcomes were statistically similar between TAVR and SAVR. However, given the inherent historical imbalances, these exploratory findings should be interpreted with caution, and dedicated prospective studies are still needed in younger and BAV populations.
- 16 July 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (14) , 5574
Open AccessTranscatheter Versus Mechanical and Bioprosthetic Surgical Aortic Valve Replacement in Retrospective Patient Cohorts with Aortic Stenosis <75 Years
Background: Comparisons between transcatheter and surgical aortic valve replacement (TAVR or SAVR) in younger aortic stenosis (AS) patients are scarce. The aim of the study was to evaluate the 5-year outcomes of AS patients n = 808) or SAVR (n = 838) were finally included. At baseline, TAVR patients had an older age [(67.9 ± 5.2) vs. (56.5 ± 9.6) years, p < 0.001] and a higher surgical risk score [(3.1 ± 1.5) vs. (2.1 ± 1.0) %, p < 0.001] than SAVR patients, which was well balanced after IPTW. The 5-year adjusted risk of the primary outcome was similar (TAVR 45.9% vs. SAVR 43.4%, weighted hazard ratio, 1.00, 95% confidence interval, 0.64–1.54, p = 0.986), which stayed comparable between TAVR and mechanical or bioprosthetic SAVR separately. In BAV patients (n = 516), the risk of death was 8.3% in the TAVR group and 3.4% in the SAVR group (p = 0.349). The risk of bioprosthetic structural valve deterioration at 5 years was comparable between groups in the overall cohort (5.7% vs. 8.4%, p = 0.478) and BAV patients (7.8% vs. 13.2%, p = 0.345). Conclusions: In this retrospective study of patients aged <75 years, the risk-adjusted 5-year major clinical outcomes were statistically similar between TAVR and SAVR. However, given the inherent historical imbalances, these exploratory findings should be interpreted with caution, and dedicated prospective studies are still needed in younger and BAV populations.
- 16 June 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 108 (3) , 686-695
Relationship Between Position, Shape, and Deformation of Papillary Muscles and Mitral Regurgitation After Transcatheter Aortic Valve Replacement
Background: Moderate/severe mitral regurgitation (MR) can affect the prognosis of patients with transcatheter aortic valve replacement (TAVR). However, few studies have focused on the role played by papillary muscles (PMs). Aims: We intend to explore the relationship between PMs and MR outcome after TAVR. Methods: This retrospective cohort study included 1159 consecutive patients who underwent TAVR. The 125 patients who had MR ≥ 3+ grade were divided into improved MR (IMR) group and non‐improved (NMR) group according to the grading of MR at 6 months after operation. MSCT was used to analyze the shape and locate the attachment of PMs. The deformation and synchrony of the PMs attachment were analyzed using two‐dimensional speckle tracking. Associations with MR improvement after TAVR were explored. Results: A total of 125 patients (IMR 93 and NMR 32; mean age, 72 years ± 8) were included. There was no significant difference in the deformation and synchrony of myocardium at attachment and in the PMs morphology between groups. However, the range of PM attachment was increased in the NMR group compared to the IMR group (1.94 ± 0.91 vs. 1.40 ± 0.65, p = 0.004; 2.16 ± 0.88 vs. 1.80 ± 0.80, p = 0.035). Inferior displacement of PMs (OR: 5.629; 95% CI: 1.421, 22.293; p = 0.014) was found to be an independent predictor of less MR improvement after TAVR. Conclusion: The PMs in the NMR group had no significant morphological tendency, but their attachment range was significantly increased and more toward apical. Inferior displacement of PMs was an independent risk factor for unalleviated MR. Trial Registration: ChiCTR 2000033419.
- 16 June 2026
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 108 (3) , 686-695
Relationship Between Position, Shape, and Deformation of Papillary Muscles and Mitral Regurgitation After Transcatheter Aortic Valve Replacement
Background: Moderate/severe mitral regurgitation (MR) can affect the prognosis of patients with transcatheter aortic valve replacement (TAVR). However, few studies have focused on the role played by papillary muscles (PMs). Aims: We intend to explore the relationship between PMs and MR outcome after TAVR. Methods: This retrospective cohort study included 1159 consecutive patients who underwent TAVR. The 125 patients who had MR ≥ 3+ grade were divided into improved MR (IMR) group and non‐improved (NMR) group according to the grading of MR at 6 months after operation. MSCT was used to analyze the shape and locate the attachment of PMs. The deformation and synchrony of the PMs attachment were analyzed using two‐dimensional speckle tracking. Associations with MR improvement after TAVR were explored. Results: A total of 125 patients (IMR 93 and NMR 32; mean age, 72 years ± 8) were included. There was no significant difference in the deformation and synchrony of myocardium at attachment and in the PMs morphology between groups. However, the range of PM attachment was increased in the NMR group compared to the IMR group (1.94 ± 0.91 vs. 1.40 ± 0.65, p = 0.004; 2.16 ± 0.88 vs. 1.80 ± 0.80, p = 0.035). Inferior displacement of PMs (OR: 5.629; 95% CI: 1.421, 22.293; p = 0.014) was found to be an independent predictor of less MR improvement after TAVR. Conclusion: The PMs in the NMR group had no significant morphological tendency, but their attachment range was significantly increased and more toward apical. Inferior displacement of PMs was an independent risk factor for unalleviated MR. Trial Registration: ChiCTR 2000033419.
- Open Access
- 1 June 2026
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 16 (6) , 455
A novel speckle-tracking index for predicting mortality following transcatheter aortic valve replacement
Background: (TAVR) are associated with cardiac damage, especially in those with pulmonary hypertension (PH) and right ventricular (RV) dysfunction. RV dyssynchrony is a novel prognostic indicator in PH patients, but its prognostic value in TAVR patients is unclear. We aimed to assess the prognostic value of RV dyssynchrony in TAVR patients. Methods: A total of 1,052 consecutive patients with severe aortic stenosis (AS) undergoing TAVR between April 2012 and December 2021 were studied. The primary endpoint was 3-year mortality. RVSD4 was defined as the standard deviation of the times to peak-systolic strain for the four mid-basal RV segments by two-dimensional (2D) speckle-tracking echocardiography (STE), and RV dyssynchrony was defined as RVSD4 >18 ms. Results: After 3-year follow-up, 182 patients (17.3%) died. Compared with the survivors, the non-survivors were older, included less females, had more comorbidities, comprised more patients with a pacemaker and New York Heart Association (NYHA) functional class III/IV, had a higher Society of Thoracic Surgeons (STS) score, worse laboratory data, and worse cardiac function. Cox regression analysis showed NYHA functional class III/IV [hazard ratio (HR): 2.134, 95% confidence interval (CI): 1.193–3.816, P=0.011], estimated glomerular filtration rate (eGFR; HR: 0.990, 95% CI: 0.980–1.000, P=0.044), and RVSD4 (HR: 1.028, 95% CI: 1.024–1.032, PConclusions: RV dyssynchrony is an independent and robust risk factor for 3-year mortality in patients with severe AS undergoing TAVR, and RVSD4 can be utilized as a risk stratification tool to prognosticate the long-term mortality of those patients.
- 1 June 2026
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 16 (6) , 455
Open AccessA novel speckle-tracking index for predicting mortality following transcatheter aortic valve replacement
Background: (TAVR) are associated with cardiac damage, especially in those with pulmonary hypertension (PH) and right ventricular (RV) dysfunction. RV dyssynchrony is a novel prognostic indicator in PH patients, but its prognostic value in TAVR patients is unclear. We aimed to assess the prognostic value of RV dyssynchrony in TAVR patients. Methods: A total of 1,052 consecutive patients with severe aortic stenosis (AS) undergoing TAVR between April 2012 and December 2021 were studied. The primary endpoint was 3-year mortality. RVSD4 was defined as the standard deviation of the times to peak-systolic strain for the four mid-basal RV segments by two-dimensional (2D) speckle-tracking echocardiography (STE), and RV dyssynchrony was defined as RVSD4 >18 ms. Results: After 3-year follow-up, 182 patients (17.3%) died. Compared with the survivors, the non-survivors were older, included less females, had more comorbidities, comprised more patients with a pacemaker and New York Heart Association (NYHA) functional class III/IV, had a higher Society of Thoracic Surgeons (STS) score, worse laboratory data, and worse cardiac function. Cox regression analysis showed NYHA functional class III/IV [hazard ratio (HR): 2.134, 95% confidence interval (CI): 1.193–3.816, P=0.011], estimated glomerular filtration rate (eGFR; HR: 0.990, 95% CI: 0.980–1.000, P=0.044), and RVSD4 (HR: 1.028, 95% CI: 1.024–1.032, PConclusions: RV dyssynchrony is an independent and robust risk factor for 3-year mortality in patients with severe AS undergoing TAVR, and RVSD4 can be utilized as a risk stratification tool to prognosticate the long-term mortality of those patients.
- Open Access
- 19 May 2026
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 15 (10) , e047475
Outcomes of Transcatheter Aortic Valve Replacement in Mixed Aortic Valve Disease: A Comparison Between Bicuspid and Tricuspid Valves
Background: The impact of aortic valve morphology on outcomes after transcatheter aortic valve replacement in patients with mixed aortic valve disease, characterized by the coexistence of aortic stenosis and regurgitation, remains poorly defined. This study aimed to compare outcomes of transcatheter aortic valve replacement between bicuspid and tricuspid aortic valve morphologies in patients with mixed aortic valve disease. Methods: We retrospectively analyzed 282 patients with mixed aortic valve disease who underwent transcatheter aortic valve replacement between January 2019 and June 2024, including 82 with bicuspid aortic valve and 200 with tricuspid aortic valve. Propensity score matching at a 1:1 ratio yielded 82 well‐balanced pairs. The primary end point was all‐cause death, and secondary end points included technical success, paravalvular leak, clinical adverse events, hemodynamic performance, and left ventricular reverse remodeling. Results: Both groups achieved high technical success rates (97.6% versus 93.9%; P =0.443) with comparable procedural outcomes. Although mild or greater paravalvular leak occurred more frequently in the bicuspid aortic valve group, this difference did not translate into higher 1‐year all‐cause death (3.7% versus 3.7%; P >0.999) or adverse events. Hemodynamic performance and left ventricular remodeling improved significantly in both groups; however, patients with bicuspid aortic valve showed more pronounced increase in left ventricular ejection fraction (median, 6.5% [interquartile range, −2.0% to 15.5%] versus 0.5% [interquartile range, −5.0% to 12.0%]; P =0.023), whereas the degree of reverse remodeling was less evident (median, −7.0 [interquartile range, −17.0 to −3.0] versus −11.0 [interquartile range, −20.0 to −6.0] mm; P =0.045). Conclusions: In patients with mixed aortic valve disease undergoing transcatheter aortic valve replacement, bicuspid aortic valve morphology was associated with more mild or greater paravalvular leak but similar procedural safety, hemodynamic outcomes, and clinical prognosis compared with tricuspid aortic valve, with distinct left ventricular recovery patterns.
- 19 May 2026
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 15 (10) , e047475
Open AccessOutcomes of Transcatheter Aortic Valve Replacement in Mixed Aortic Valve Disease: A Comparison Between Bicuspid and Tricuspid Valves
Background: The impact of aortic valve morphology on outcomes after transcatheter aortic valve replacement in patients with mixed aortic valve disease, characterized by the coexistence of aortic stenosis and regurgitation, remains poorly defined. This study aimed to compare outcomes of transcatheter aortic valve replacement between bicuspid and tricuspid aortic valve morphologies in patients with mixed aortic valve disease. Methods: We retrospectively analyzed 282 patients with mixed aortic valve disease who underwent transcatheter aortic valve replacement between January 2019 and June 2024, including 82 with bicuspid aortic valve and 200 with tricuspid aortic valve. Propensity score matching at a 1:1 ratio yielded 82 well‐balanced pairs. The primary end point was all‐cause death, and secondary end points included technical success, paravalvular leak, clinical adverse events, hemodynamic performance, and left ventricular reverse remodeling. Results: Both groups achieved high technical success rates (97.6% versus 93.9%; P =0.443) with comparable procedural outcomes. Although mild or greater paravalvular leak occurred more frequently in the bicuspid aortic valve group, this difference did not translate into higher 1‐year all‐cause death (3.7% versus 3.7%; P >0.999) or adverse events. Hemodynamic performance and left ventricular remodeling improved significantly in both groups; however, patients with bicuspid aortic valve showed more pronounced increase in left ventricular ejection fraction (median, 6.5% [interquartile range, −2.0% to 15.5%] versus 0.5% [interquartile range, −5.0% to 12.0%]; P =0.023), whereas the degree of reverse remodeling was less evident (median, −7.0 [interquartile range, −17.0 to −3.0] versus −11.0 [interquartile range, −20.0 to −6.0] mm; P =0.045). Conclusions: In patients with mixed aortic valve disease undergoing transcatheter aortic valve replacement, bicuspid aortic valve morphology was associated with more mild or greater paravalvular leak but similar procedural safety, hemodynamic outcomes, and clinical prognosis compared with tricuspid aortic valve, with distinct left ventricular recovery patterns.
- Open Access
- 11 April 2026
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 26 (1)
Surgical repair of a ventricular septal defect following low-velocity blunt chest trauma
Ventricular septal defect (VSD) after blunt chest trauma is a rare form of heart damage. We present the case of a 14-year-old male student who developed a
- 11 April 2026
- Published by Springer Nature in BMC Cardiovascular Disorders
- Vol. 26 (1)
Open AccessSurgical repair of a ventricular septal defect following low-velocity blunt chest trauma
Ventricular septal defect (VSD) after blunt chest trauma is a rare form of heart damage. We present the case of a 14-year-old male student who developed a
- Open Access
- 8 January 2026
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 13 (1)
Paroxysmal hypotension and hypoxaemia caused by severe dynamic secondary mitral and tricuspid regurgitation after acute myocardial infarction
A 57-year-old male patient developed paroxysmal hypotension and hypoxaemia during endotracheal extubation post-acute myocardial infarction revascularization. The underlying cause was severe dynamic mitral regurgitation (MR) and secondary tricuspid regurgitation. After successful extubation and weaning, the patient’s MR nearly resolved. Discharged in improved condition with guideline-directed medical therapy, the patient was soon readmitted for heart failure with pulmonary oedema. The transthoracic echocardiogram confirmed recurrent, worsening MR. Transcatheter edge-to-edge repair was successfully performed, reducing the patient’s severe MR to trivial and resolving tricuspid regurgitation completely. At 1-year follow-up, the patient remained stable with improved cardiac function and no readmissions for cardiac causes.
- 8 January 2026
- Published by Oxford University Press (OUP) in ESC Heart Failure
- Vol. 13 (1)
Open AccessParoxysmal hypotension and hypoxaemia caused by severe dynamic secondary mitral and tricuspid regurgitation after acute myocardial infarction
A 57-year-old male patient developed paroxysmal hypotension and hypoxaemia during endotracheal extubation post-acute myocardial infarction revascularization. The underlying cause was severe dynamic mitral regurgitation (MR) and secondary tricuspid regurgitation. After successful extubation and weaning, the patient’s MR nearly resolved. Discharged in improved condition with guideline-directed medical therapy, the patient was soon readmitted for heart failure with pulmonary oedema. The transthoracic echocardiogram confirmed recurrent, worsening MR. Transcatheter edge-to-edge repair was successfully performed, reducing the patient’s severe MR to trivial and resolving tricuspid regurgitation completely. At 1-year follow-up, the patient remained stable with improved cardiac function and no readmissions for cardiac causes.
- Open Access
- 1 January 2026
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 2026 (1) , 8817783
Transcatheter Tricuspid Valve Replacement in Patients After Prior Left‐Sided Valve Surgery: A Multicenter Retrospective Analysis
Background: Functional tricuspid regurgitation (TR) after previous left‐sided valve surgery (LSVS) represents a significant proportion of all isolated TR cases; tricuspid valve reoperation in such patients, often in the advanced stage of disease, is historically regarded as high‐risk. Percutaneous transcatheter–based therapies for TR emerge as a potential solution. We sought to verify the performance of the LuX‐Valve Plus system in patients with a history of LSVS. Methods: A post hoc analysis of patients enrolled in the first‐in‐man and confirmatory study and an investigator‐initiated trial of the LuX‐Valve Plus system was conducted. Multiple endpoints, including mortality, valve performance, and functional status, were compared between patients with or without a history of LSVS. Propensity score matching (PSM) was used to minimize baseline differences between groups. Results: The study included 153 patients, with 56 patients having prior LSVS. After PSM, there were a total of 46 matched pairs. All‐cause mortality at 6 months was similar between groups (2.38% vs. 0%, respectively). Less‐than‐moderate paravalvular leakage and central TR were consistently observed in approximately 85% and 95% of patients through 6 months. Patients after prior LSVS achieved similar functional outcome in terms of the proportion of patients in NYHA Class I–II at 6 months (81.25% vs. 95.83%, p = 0.221). The Kansas City Cardiomyopathy Questionnaire score improved significantly after the procedure. Conclusions: In this small‐scale study, transcatheter implantation of the LuX‐Valve Plus for TR appeared to be safe and effective in patients with a history of LSVS, showing lower short‐term mortality and a degree of TR correction comparable to surgical outcomes.
- 1 January 2026
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 2026 (1) , 8817783
Open AccessTranscatheter Tricuspid Valve Replacement in Patients After Prior Left‐Sided Valve Surgery: A Multicenter Retrospective Analysis
Background: Functional tricuspid regurgitation (TR) after previous left‐sided valve surgery (LSVS) represents a significant proportion of all isolated TR cases; tricuspid valve reoperation in such patients, often in the advanced stage of disease, is historically regarded as high‐risk. Percutaneous transcatheter–based therapies for TR emerge as a potential solution. We sought to verify the performance of the LuX‐Valve Plus system in patients with a history of LSVS. Methods: A post hoc analysis of patients enrolled in the first‐in‐man and confirmatory study and an investigator‐initiated trial of the LuX‐Valve Plus system was conducted. Multiple endpoints, including mortality, valve performance, and functional status, were compared between patients with or without a history of LSVS. Propensity score matching (PSM) was used to minimize baseline differences between groups. Results: The study included 153 patients, with 56 patients having prior LSVS. After PSM, there were a total of 46 matched pairs. All‐cause mortality at 6 months was similar between groups (2.38% vs. 0%, respectively). Less‐than‐moderate paravalvular leakage and central TR were consistently observed in approximately 85% and 95% of patients through 6 months. Patients after prior LSVS achieved similar functional outcome in terms of the proportion of patients in NYHA Class I–II at 6 months (81.25% vs. 95.83%, p = 0.221). The Kansas City Cardiomyopathy Questionnaire score improved significantly after the procedure. Conclusions: In this small‐scale study, transcatheter implantation of the LuX‐Valve Plus for TR appeared to be safe and effective in patients with a history of LSVS, showing lower short‐term mortality and a degree of TR correction comparable to surgical outcomes.
- 29 December 2025
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 39 (4) , 358-369
Prognostic Implications of a Novel Right Ventricle–Pulmonary Artery Coupling in Patients with Severe Aortic Stenosis after Transcatheter Aortic Valve Replacement
- 29 December 2025
- Published by Elsevier in Journal of the American Society of Echocardiography
- Vol. 39 (4) , 358-369
Prognostic Implications of a Novel Right Ventricle–Pulmonary Artery Coupling in Patients with Severe Aortic Stenosis after Transcatheter Aortic Valve Replacement