Shuichi Yamamoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shuichi Yamamoto has a total of 148 co-authors. Here are the top co-authors by number of shared publications:
Noriko Yoshimoto
Biomedical Engineering Center (YUBEC), Yamaguchi University
33 shared publicationsYuji Sano
Prof. emeritus of Yamaguchi Univ
17 shared publicationsKazuhiro Nakanishi
9 shared publicationsSachie Fujii
Bio-Process Engineering Laboratory, Graduate School of Medicine & School of Engineering, Yamaguchi University
8 shared publicationsRyuichi Matsuno
Department of Food Science and Technology, Faculty of Agriculture, Kyoto University, Sakyo‐ku, Kyoto 606, Japan
7 shared publicationsTadashi Kamikubo
Department of Food Science and Technology, Faculty of Agriculture, Kyoto University, Sakyo‐ku, Kyoto 606, Japan
6 shared publications
Latest Publications
- Open Access
- 15 March 2024
- Published by Japan Society for Food Engineering in Japan Journal of Food Engineering
- Vol. 25 (1) , 15-22
A Method for Determining the Optimum Temperature for a Polyphenol Separation Process by Reversed Phase Chromatography
A method for determining the optimum temperature for the separation of two polyphenols by polystyrene divinylbenzene resin reversed phase liquid chromatography with the ethanol-water mixture mobile phase was proposed based on the iso-resolution curve concept. The distribution coefficient and the stationary phase diffusion coefficient were formulated as a function of temperature T and ethanol concentration I. From the iso-resolution curve, the productivity P* was calculated as a function of T. It was found that there is an optimum T, where the highest P* can be obtained.
- 15 March 2024
- Published by Japan Society for Food Engineering in Japan Journal of Food Engineering
- Vol. 25 (1) , 15-22
Open AccessA Method for Determining the Optimum Temperature for a Polyphenol Separation Process by Reversed Phase Chromatography
A method for determining the optimum temperature for the separation of two polyphenols by polystyrene divinylbenzene resin reversed phase liquid chromatography with the ethanol-water mixture mobile phase was proposed based on the iso-resolution curve concept. The distribution coefficient and the stationary phase diffusion coefficient were formulated as a function of temperature T and ethanol concentration I. From the iso-resolution curve, the productivity P* was calculated as a function of T. It was found that there is an optimum T, where the highest P* can be obtained.
- Open Access
- 15 December 2023
- Published by Japan Society for Food Engineering in Japan Journal of Food Engineering
- Vol. 24 (4) , 113-117
Continuous Monitoring of High Protein Concentrations by Optical Rotation—A Case Study for Continuous Monitoring of Monoclonal Antibody Concentrations During Ultrafiltration
Measuring protein concentration CP is important for many unit operations at food or bio-industry such as bioreactors, adsorptions, chromatography separations, and concentration operation by ultrafiltration. Although various methods are available, most of them are not suited for measuring high CP. In this paper we have developed a method for continuous monitoring of very high CP by optical rotation (OR). A flow-cell was built based on the standard cell. Linear correlations were confirmed between OR and CP in the range CP = 0 to 20 g/L, the slope of which was similar to that obtained for the batch measurement. As the flow-cell volume is large, the effect of the input signal shape on the output signal was analyzed based on the mechanistic model considering the continuous stirred tank reactor and the plug flow reactor. This method was applied to the continuous monitoring of CP during concentration by ultrafiltration. The measured CP values (CP = 12 to 68 g/L) were in good agreement with the off-line measured values by the absorbance at 280 nm after dilution.
- 15 December 2023
- Published by Japan Society for Food Engineering in Japan Journal of Food Engineering
- Vol. 24 (4) , 113-117
Open AccessContinuous Monitoring of High Protein Concentrations by Optical Rotation—A Case Study for Continuous Monitoring of Monoclonal Antibody Concentrations During Ultrafiltration
Measuring protein concentration CP is important for many unit operations at food or bio-industry such as bioreactors, adsorptions, chromatography separations, and concentration operation by ultrafiltration. Although various methods are available, most of them are not suited for measuring high CP. In this paper we have developed a method for continuous monitoring of very high CP by optical rotation (OR). A flow-cell was built based on the standard cell. Linear correlations were confirmed between OR and CP in the range CP = 0 to 20 g/L, the slope of which was similar to that obtained for the batch measurement. As the flow-cell volume is large, the effect of the input signal shape on the output signal was analyzed based on the mechanistic model considering the continuous stirred tank reactor and the plug flow reactor. This method was applied to the continuous monitoring of CP during concentration by ultrafiltration. The measured CP values (CP = 12 to 68 g/L) were in good agreement with the off-line measured values by the absorbance at 280 nm after dilution.
- Open Access
- 10 September 2023
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 121 (8) , 2269-2277
Integrated continuous downstream process of monoclonal antibody developed by converting the batch platform process based on the process characterization
A continuous downstream process of monoclonal antibody was developed based on the process characterization. Periodic‐counter current chromatography (PCCC) with two protein A columns was used for the capture step. For low pH virus inactivation (VI), a batch reactor was employed, which can work as a surge (buffer) tank. Flow‐through chromatography (FTC) with two connected columns of different separation modes (anion‐mixed mode and cation exchange) was designed as a polish step. After 24 h PCCC run, the collected pool was processed for VI. After adjusting pH and electric conductivity, the solution was fed to the two connected FTC columns for 24 h. Virus filter was also connected to the exit of the connected‐column. PCCC and FTC were run in parallel. Six runs of different feed rates (0.5–10 L/day) and feed concentrations (1–3.2 g/L) were performed with protein A columns of 1–5 mL and FTC columns of 3–10 mL. The largest run (feed rate 10 L/day, feed concentration 2 g/L) was carried out at a GMP facility with 15 mL protein A columns and 100 mL FTC columns. Good recovery and purity values were obtained for all runs. The process was found to be flexible and stable for feed fluctuations. Only three surge or pool tanks were needed in addition to the final product pool tank.
- 10 September 2023
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 121 (8) , 2269-2277
Open AccessIntegrated continuous downstream process of monoclonal antibody developed by converting the batch platform process based on the process characterization
A continuous downstream process of monoclonal antibody was developed based on the process characterization. Periodic‐counter current chromatography (PCCC) with two protein A columns was used for the capture step. For low pH virus inactivation (VI), a batch reactor was employed, which can work as a surge (buffer) tank. Flow‐through chromatography (FTC) with two connected columns of different separation modes (anion‐mixed mode and cation exchange) was designed as a polish step. After 24 h PCCC run, the collected pool was processed for VI. After adjusting pH and electric conductivity, the solution was fed to the two connected FTC columns for 24 h. Virus filter was also connected to the exit of the connected‐column. PCCC and FTC were run in parallel. Six runs of different feed rates (0.5–10 L/day) and feed concentrations (1–3.2 g/L) were performed with protein A columns of 1–5 mL and FTC columns of 3–10 mL. The largest run (feed rate 10 L/day, feed concentration 2 g/L) was carried out at a GMP facility with 15 mL protein A columns and 100 mL FTC columns. Good recovery and purity values were obtained for all runs. The process was found to be flexible and stable for feed fluctuations. Only three surge or pool tanks were needed in addition to the final product pool tank.
- Open Access
- 8 June 2023
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 120 (10) , 2977-2988
Viral clearance in end‐to‐end integrated continuous process for mAb purification: Total flow‐through integrated polishing on two columns connected to virus filtration
There are few reports of the adoption of continuous processes in bioproduction, particularly the implementation of end‐to‐end continuous or integrated processes, due to difficulties such as feed adjustment and incorporating virus filtration. Here, we propose an end‐to‐end integrated continuous process for a monoclonal antibody (mAb) with three integrated process segments: upstream production processes with pool‐less direct connection, pooled low pH virus inactivation with pH control and a total flow‐through integrated polishing process in which two columns were directly connected with a virus filter. The pooled virus inactivation step defines the batch, and high impurities reduction and mAb recovery were achieved for batches conducted in succession. Viral clearance tests also confirmed robust virus reduction for the flow‐through two‐column chromatography and the virus filtration steps. Additionally, viral clearance tests with two different hollow fiber virus filters operated at flux ranging from 1.5 to 40 LMH (liters per effective surface area of filter in square meters per hour) confirmed robust virus reduction over these ranges. Complete clearance with virus logarithmic reduction value ≥4 was achieved even with a process pause at the lowest flux. The end‐to‐end integrated continuous process proposed in this study is amenable to production processes, and the investigated virus filters have excellent applicability to continuous processes conducted at constant flux.
- 8 June 2023
- Published by Wiley in Biotechnology and Bioengineering
- Vol. 120 (10) , 2977-2988
Open AccessViral clearance in end‐to‐end integrated continuous process for mAb purification: Total flow‐through integrated polishing on two columns connected to virus filtration
There are few reports of the adoption of continuous processes in bioproduction, particularly the implementation of end‐to‐end continuous or integrated processes, due to difficulties such as feed adjustment and incorporating virus filtration. Here, we propose an end‐to‐end integrated continuous process for a monoclonal antibody (mAb) with three integrated process segments: upstream production processes with pool‐less direct connection, pooled low pH virus inactivation with pH control and a total flow‐through integrated polishing process in which two columns were directly connected with a virus filter. The pooled virus inactivation step defines the batch, and high impurities reduction and mAb recovery were achieved for batches conducted in succession. Viral clearance tests also confirmed robust virus reduction for the flow‐through two‐column chromatography and the virus filtration steps. Additionally, viral clearance tests with two different hollow fiber virus filters operated at flux ranging from 1.5 to 40 LMH (liters per effective surface area of filter in square meters per hour) confirmed robust virus reduction over these ranges. Complete clearance with virus logarithmic reduction value ≥4 was achieved even with a process pause at the lowest flux. The end‐to‐end integrated continuous process proposed in this study is amenable to production processes, and the investigated virus filters have excellent applicability to continuous processes conducted at constant flux.
- Open Access
- 15 March 2023
- Published by Japan Society for Food Engineering in Japan Journal of Food Engineering
- Vol. 24 (1) , 11-18
高品質な乾燥食品の生産を実現させる高機能乾燥機の研究開発と製品化
野菜などの食品乾燥の品質と効率を考慮した最適乾燥条件の迅速決定方法を確立するために,画像情報を含む各種オンラインモニタリングデバイスを実装した乾燥装置を開発した.はじめに,デジタルカメラ,温湿度センサー,電子天秤を搭載した連続測定が可能な実験室レベルの小型乾燥装置を製作し,この装置を基に,センサーとサンプルポートを装備した小型の試験研究用棚段乾燥装置を作製した.モデル食品の乾燥過程の画像をオンラインで撮影するとともに,サンプルポートからサンプリングした試料の遊離アミノ酸濃度を測定したところ材料温度が上昇する乾燥後期で減少し,同時に乾燥試料表面の変色(褐変)が生じていた.材料の画像と材料温度のモニタリングから重要な情報を得ることができる可能性とメカニステイックモデルシミュレーションは最適乾燥プログラムの設定に有用であることが示唆された.
- 15 March 2023
- Published by Japan Society for Food Engineering in Japan Journal of Food Engineering
- Vol. 24 (1) , 11-18
Open Access高品質な乾燥食品の生産を実現させる高機能乾燥機の研究開発と製品化
野菜などの食品乾燥の品質と効率を考慮した最適乾燥条件の迅速決定方法を確立するために,画像情報を含む各種オンラインモニタリングデバイスを実装した乾燥装置を開発した.はじめに,デジタルカメラ,温湿度センサー,電子天秤を搭載した連続測定が可能な実験室レベルの小型乾燥装置を製作し,この装置を基に,センサーとサンプルポートを装備した小型の試験研究用棚段乾燥装置を作製した.モデル食品の乾燥過程の画像をオンラインで撮影するとともに,サンプルポートからサンプリングした試料の遊離アミノ酸濃度を測定したところ材料温度が上昇する乾燥後期で減少し,同時に乾燥試料表面の変色(褐変)が生じていた.材料の画像と材料温度のモニタリングから重要な情報を得ることができる可能性とメカニステイックモデルシミュレーションは最適乾燥プログラムの設定に有用であることが示唆された.
- Open Access
- 24 February 2023
- Published by Wiley
Viral clearance in end-to-end continuous process for mAb purification: Total flow-through integrated polishing on two columns connected to virus filtration
There are few reports of the adoption of continuous processes in bioproduction, particularly the implementation of end-to-end continuous processes, due to difficulties such as feed adjustment, production batch demarcation, and incorporating virus filtration. Here, we propose an end-to-end continuous process for a monoclonal antibody (mAb) with three integrated process segments: upstream production processes with pool-less direct connection, pooled low pH virus inactivation with automated pH control and a total flow-through integrated polishing process in which two columns were directly connected with a virus filter. The pooled virus inactivation step demarcates the batch, and high impurities reduction and mAb recovery were achieved for batches conducted in succession. Viral clearance tests also confirmed robust virus reduction for the flow-through two column chromatography and the virus filtration steps. Additionally, viral clearance tests with two different hollow fiber virus filters operated at flux ranging from 1.5 to 40 LMH confirmed robust virus reduction over these ranges. Complete clearance with LRV ≥ 4 was achieved even with a process pause at the lowest flux. The end-to-end continuous process proposed in this study is highly applicable to production processes, and the investigated virus filters have excellent applicability to continuous processes conducted at constant flux.
- 24 February 2023
- Published by Wiley
Open AccessViral clearance in end-to-end continuous process for mAb purification: Total flow-through integrated polishing on two columns connected to virus filtration
There are few reports of the adoption of continuous processes in bioproduction, particularly the implementation of end-to-end continuous processes, due to difficulties such as feed adjustment, production batch demarcation, and incorporating virus filtration. Here, we propose an end-to-end continuous process for a monoclonal antibody (mAb) with three integrated process segments: upstream production processes with pool-less direct connection, pooled low pH virus inactivation with automated pH control and a total flow-through integrated polishing process in which two columns were directly connected with a virus filter. The pooled virus inactivation step demarcates the batch, and high impurities reduction and mAb recovery were achieved for batches conducted in succession. Viral clearance tests also confirmed robust virus reduction for the flow-through two column chromatography and the virus filtration steps. Additionally, viral clearance tests with two different hollow fiber virus filters operated at flux ranging from 1.5 to 40 LMH confirmed robust virus reduction over these ranges. Complete clearance with LRV ≥ 4 was achieved even with a process pause at the lowest flux. The end-to-end continuous process proposed in this study is highly applicable to production processes, and the investigated virus filters have excellent applicability to continuous processes conducted at constant flux.
- Open Access
- 1 January 2023
- Published by Society of Chemical Engineers, Japan in International Chemical Engineering Symposia Proceedings
- Vol. 2022, 13-17
Temperature Effect on the Separation Performance of Chromatography
The effect of temperature T on the chromatographic separation performance was examined by using a model separation system: polyphenol isocratic elution separation by polymer-resin chromatography with ethanol-water mobile phases within the temperature range 15-45°C. HETP decreased with increasing T. The reduced HETP and the reduced velocity plots can be approximated by a single universal curve. The equations describing the distribution coefficient K as a function of T were also developed. A simple equation was derived, which can describe the resolution of two components Rs as a function of T. Rs did not increase significantly with T while the separation time can be reduced.
- 1 January 2023
- Published by Society of Chemical Engineers, Japan in International Chemical Engineering Symposia Proceedings
- Vol. 2022, 13-17
Open AccessTemperature Effect on the Separation Performance of Chromatography
The effect of temperature T on the chromatographic separation performance was examined by using a model separation system: polyphenol isocratic elution separation by polymer-resin chromatography with ethanol-water mobile phases within the temperature range 15-45°C. HETP decreased with increasing T. The reduced HETP and the reduced velocity plots can be approximated by a single universal curve. The equations describing the distribution coefficient K as a function of T were also developed. A simple equation was derived, which can describe the resolution of two components Rs as a function of T. Rs did not increase significantly with T while the separation time can be reduced.
- Open Access
- 1 September 2022
- Published by The Japanese Geotechnical Society in Japanese Geotechnical Journal
- Vol. 17 (3) , 353-360
Study of strain behavior with drying and wetting in compacted Na-type bentonite
地層処分におけるベントナイト系緩衝材は,廃棄体からの崩壊熱によって,飽和度が低下することが予測されている。そこで,地層処分の安全性確保のために,不飽和ベントナイトの力学特性に及ぼす乾湿挙動の影響を明らかにする必要がある。本研究では,蒸気圧法を援用して,締固めたベントナイト供試体のサクション変化に伴うひずみ挙動を測定した。その結果,供試体の初期条件として飽和させた供試体は,乾湿作用によってサクションと間隙比の関係が不可逆的に変化する一方,初期不飽和供試体は可逆的に変化することが分かった。また,これらのひずみ挙動について,ベントナイトの構造骨格に着目して微視的構造から推察を行った。
- 1 September 2022
- Published by The Japanese Geotechnical Society in Japanese Geotechnical Journal
- Vol. 17 (3) , 353-360
Open AccessStudy of strain behavior with drying and wetting in compacted Na-type bentonite
地層処分におけるベントナイト系緩衝材は,廃棄体からの崩壊熱によって,飽和度が低下することが予測されている。そこで,地層処分の安全性確保のために,不飽和ベントナイトの力学特性に及ぼす乾湿挙動の影響を明らかにする必要がある。本研究では,蒸気圧法を援用して,締固めたベントナイト供試体のサクション変化に伴うひずみ挙動を測定した。その結果,供試体の初期条件として飽和させた供試体は,乾湿作用によってサクションと間隙比の関係が不可逆的に変化する一方,初期不飽和供試体は可逆的に変化することが分かった。また,これらのひずみ挙動について,ベントナイトの構造骨格に着目して微視的構造から推察を行った。
- 15 August 2022
- Published by Elsevier in Journal of Chromatography A
- Vol. 1680, 463423
An accelerated approach for mechanistic model based prediction of linear gradient elution ion-exchange chromatography of proteins
- 15 August 2022
- Published by Elsevier in Journal of Chromatography A
- Vol. 1680, 463423
An accelerated approach for mechanistic model based prediction of linear gradient elution ion-exchange chromatography of proteins
- Open Access
- 1 January 2022
- Published by Society of Chemical Engineers, Japan in International Chemical Engineering Symposia Proceedings
- Vol. 2022, 9-12
Evaluation of the Efficiency of Continuous Capture Chromatography
Multi-column chromatography (periodic counter-current chromatography, PCCC) with protein A affinity resins is used as an efficient monoclonal antibody (mAb) continuous capture process. However, the evaluation of the efficiency of PCCC process compared with repeated batch (or cyclic) operation (RBO) is still not standardized. In this study, we proposed two criteria for evaluating the capture process efficiency, productivity P and buffer consumption per load amount, BC. These criteria were calculated for 2 column, 3 column and 4 column-PCCC and for RBO. For PCCC, P was proportional to mAb concentration C0 and inversely proportional to the number of columns, nC since the loaded amount of mAb ML was fixed for the calculation. Bc did not depend on C0 or nC as ML was the same. For RBO, BC was larger by 20% at residence time (RT) = 4 minutes, and by 50% at RT = 2 minutes whereas P was similar to or slightly lower than that for 2C-PCCC at the same RT (4 minutes).
- 1 January 2022
- Published by Society of Chemical Engineers, Japan in International Chemical Engineering Symposia Proceedings
- Vol. 2022, 9-12
Open AccessEvaluation of the Efficiency of Continuous Capture Chromatography
Multi-column chromatography (periodic counter-current chromatography, PCCC) with protein A affinity resins is used as an efficient monoclonal antibody (mAb) continuous capture process. However, the evaluation of the efficiency of PCCC process compared with repeated batch (or cyclic) operation (RBO) is still not standardized. In this study, we proposed two criteria for evaluating the capture process efficiency, productivity P and buffer consumption per load amount, BC. These criteria were calculated for 2 column, 3 column and 4 column-PCCC and for RBO. For PCCC, P was proportional to mAb concentration C0 and inversely proportional to the number of columns, nC since the loaded amount of mAb ML was fixed for the calculation. Bc did not depend on C0 or nC as ML was the same. For RBO, BC was larger by 20% at residence time (RT) = 4 minutes, and by 50% at RT = 2 minutes whereas P was similar to or slightly lower than that for 2C-PCCC at the same RT (4 minutes).