Jeong Hun Kim
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jeong Hun Kim has a total of 84 co-authors. Here are the top co-authors by number of shared publications:
- Sanghoon Lee
Physics Department, Korea University, Seoul, Republic of Korea
6 shared publications Sang-Hoon Lee
KU-KIST Graduate School of Converging Science and Technology, Korea University, Seoul 02841, Republic of Korea; School of Biomedical Engineering, College of Health Science, Korea University, Seoul 02841, Republic of Korea
5 shared publications- Ji-Young Hwang
Innovative Carbon-Bio-Convergence Lab., Korea Carbon Industry Promotion Agency (kcarbon), 110-11 Ballyong-ro, Deokjin-gu, Jeonju 54853, Republic of Korea
3 shared publications Seung Min Lee
Department of Biomedical Engineering, College of Health Science, Korea University
3 shared publicationsChong-Yun Kang
2 shared publications- Joong Hoon Lee
KU-KIST Graduate School of Converging Science and Technology, Korea University, Seoul, Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 8 April 2026
- Published by Elsevier in Materials Today Advances
- Vol. 30
Ferrocene-loaded glycerogel dressing for reactive oxygen species-modulated active wound healing
- 8 April 2026
- Published by Elsevier in Materials Today Advances
- Vol. 30
Open AccessFerrocene-loaded glycerogel dressing for reactive oxygen species-modulated active wound healing
- 1 August 2019
- Published by Elsevier in Nano Energy
- Vol. 62, 144-153
Double layered dielectric elastomer by vapor encapsulation casting for highly deformable and strongly adhesive triboelectric materials
- 1 August 2019
- Published by Elsevier in Nano Energy
- Vol. 62, 144-153
Double layered dielectric elastomer by vapor encapsulation casting for highly deformable and strongly adhesive triboelectric materials
- 1 October 2018
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 117, 436-443
Flexible deep brain neural probe for localized stimulation and detection with metal guide
- 1 October 2018
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 117, 436-443
Flexible deep brain neural probe for localized stimulation and detection with metal guide
- 1 April 2018
- Published by Elsevier in Applied Energy
- Vol. 216, 741-750
Piezoelectric polymer-based roadway energy harvesting via displacement amplification module
- 1 April 2018
- Published by Elsevier in Applied Energy
- Vol. 216, 741-750
Piezoelectric polymer-based roadway energy harvesting via displacement amplification module
- Open Access
- 22 January 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-11
Simple and cost-effective method of highly conductive and elastic carbon nanotube/polydimethylsiloxane composite for wearable electronics
The development of various flexible and stretchable materials has attracted interest for promising applications in biomedical engineering and electronics industries. This interest in wearable electronics, stretchable circuits, and flexible displays has created a demand for stable, easily manufactured, and cheap materials. However, the construction of flexible and elastic electronics, on which commercial electronic components can be mounted through simple and cost-effective processing, remains challenging. We have developed a nanocomposite of carbon nanotubes (CNTs) and polydimethylsiloxane (PDMS) elastomer. To achieve uniform distributions of CNTs within the polymer, an optimized dispersion process was developed using isopropyl alcohol (IPA) and methyl-terminated PDMS in combination with ultrasonication. After vaporizing the IPA, various shapes and sizes can be easily created with the nanocomposite, depending on the mold. The material provides high flexibility, elasticity, and electrical conductivity without requiring a sandwich structure. It is also biocompatible and mechanically stable, as demonstrated by cytotoxicity assays and cyclic strain tests (over 10,000 times). We demonstrate the potential for the healthcare field through strain sensor, flexible electric circuits, and biopotential measurements such as EEG, ECG, and EMG. This simple and cost-effective fabrication method for CNT/PDMS composites provides a promising process and material for various applications of wearable electronics.
- 22 January 2018
- Published by Springer Nature in Scientific Reports
- Vol. 8 (1) , 1-11
Open AccessSimple and cost-effective method of highly conductive and elastic carbon nanotube/polydimethylsiloxane composite for wearable electronics
The development of various flexible and stretchable materials has attracted interest for promising applications in biomedical engineering and electronics industries. This interest in wearable electronics, stretchable circuits, and flexible displays has created a demand for stable, easily manufactured, and cheap materials. However, the construction of flexible and elastic electronics, on which commercial electronic components can be mounted through simple and cost-effective processing, remains challenging. We have developed a nanocomposite of carbon nanotubes (CNTs) and polydimethylsiloxane (PDMS) elastomer. To achieve uniform distributions of CNTs within the polymer, an optimized dispersion process was developed using isopropyl alcohol (IPA) and methyl-terminated PDMS in combination with ultrasonication. After vaporizing the IPA, various shapes and sizes can be easily created with the nanocomposite, depending on the mold. The material provides high flexibility, elasticity, and electrical conductivity without requiring a sandwich structure. It is also biocompatible and mechanically stable, as demonstrated by cytotoxicity assays and cyclic strain tests (over 10,000 times). We demonstrate the potential for the healthcare field through strain sensor, flexible electric circuits, and biopotential measurements such as EEG, ECG, and EMG. This simple and cost-effective fabrication method for CNT/PDMS composites provides a promising process and material for various applications of wearable electronics.
- Open Access
- 8 August 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-8
Single Microfluidic Electrochemical Sensor System for Simultaneous Multi-Pulmonary Hypertension Biomarker Analyses
Miniaturized microfluidic biosensors have recently been advanced for portable point-of-care diagnostics by integrating lab-on-a-chip technology and electrochemical analysis. However, the design of a small, integrated, and reliable biosensor for multiple and simultaneous electrochemical analyses in a single device remains a challenge. Here, we present a simultaneous microfluidic electrochemical biosensing system to detect multiple biomarkers of pulmonary hypertension diseases in a single device. The miniaturized biosensor, which is composed of five chambers, is precisely and individually controlled using in-house-built pneumatic microvalves to manipulate the flow pathway. Each chamber is connected to an electrochemical sensor designed to detect four different biomarkers plus a reference control. Our design allows for loading of multiple reagents for simultaneous analyses. On the basis of the developed microfluidic electrochemical sensor system, we successfully detected four well-defined pulmonary hypertension-associated biomarkers, namely, fibrinogen, adiponectin, low-density lipoprotein, and 8-isoprostane. This novel approach offers a new platform for a rapid, miniaturized, and sensitive diagnostic sensor in a single device for various human diseases.
- 8 August 2017
- Published by Springer Nature in Scientific Reports
- Vol. 7 (1) , 1-8
Open AccessSingle Microfluidic Electrochemical Sensor System for Simultaneous Multi-Pulmonary Hypertension Biomarker Analyses
Miniaturized microfluidic biosensors have recently been advanced for portable point-of-care diagnostics by integrating lab-on-a-chip technology and electrochemical analysis. However, the design of a small, integrated, and reliable biosensor for multiple and simultaneous electrochemical analyses in a single device remains a challenge. Here, we present a simultaneous microfluidic electrochemical biosensing system to detect multiple biomarkers of pulmonary hypertension diseases in a single device. The miniaturized biosensor, which is composed of five chambers, is precisely and individually controlled using in-house-built pneumatic microvalves to manipulate the flow pathway. Each chamber is connected to an electrochemical sensor designed to detect four different biomarkers plus a reference control. Our design allows for loading of multiple reagents for simultaneous analyses. On the basis of the developed microfluidic electrochemical sensor system, we successfully detected four well-defined pulmonary hypertension-associated biomarkers, namely, fibrinogen, adiponectin, low-density lipoprotein, and 8-isoprostane. This novel approach offers a new platform for a rapid, miniaturized, and sensitive diagnostic sensor in a single device for various human diseases.
- 25 May 2016
- Published by Wiley in Advanced Functional Materials
- Vol. 26 (29) , 5211-5221
Resistive Switching Memory Integrated with Nanogenerator for Self‐Powered Bioimplantable Devices
Resistive random access memory (ReRAM) devices powered by piezoelectric nanogenerators (NGs) have been investigated for their application to future implantable biomedical devices. Biocompatible (Na0.5K0.5)NbO3 (NKN) films that are grown at 300 °C on TiN/SiO2/Si and flexible TiN/Polyimide (TiN‐PI) substrates are used for ReRAM and NGs, respectively. These NKN films have an amorphous phase containing NKN nanocrystals with a size of 5.0 nm. NKN ReRAM devices exhibit typical bipolar switching behavior that can be explained by the formation and rupture of oxygen‐vacancy filaments. They have good ReRAM properties such as a large ratio of RHRS to RLRS as well as high reliability. The NKN film grown on flexible TiN‐PI substrate exhibits a high piezoelectric strain constant of 50 pm V−1. The NKN NG has a large open‐circuit output voltage of 2.0 V and a short‐circuit output current of 40 nA, which are sufficient to drive NKN ReRAM devices. Stable switching properties with a large ON/OFF ratio of 102 are obtained from NKN ReRAM driven by NKN NG.
- 25 May 2016
- Published by Wiley in Advanced Functional Materials
- Vol. 26 (29) , 5211-5221
Resistive Switching Memory Integrated with Nanogenerator for Self‐Powered Bioimplantable Devices
Resistive random access memory (ReRAM) devices powered by piezoelectric nanogenerators (NGs) have been investigated for their application to future implantable biomedical devices. Biocompatible (Na0.5K0.5)NbO3 (NKN) films that are grown at 300 °C on TiN/SiO2/Si and flexible TiN/Polyimide (TiN‐PI) substrates are used for ReRAM and NGs, respectively. These NKN films have an amorphous phase containing NKN nanocrystals with a size of 5.0 nm. NKN ReRAM devices exhibit typical bipolar switching behavior that can be explained by the formation and rupture of oxygen‐vacancy filaments. They have good ReRAM properties such as a large ratio of RHRS to RLRS as well as high reliability. The NKN film grown on flexible TiN‐PI substrate exhibits a high piezoelectric strain constant of 50 pm V−1. The NKN NG has a large open‐circuit output voltage of 2.0 V and a short‐circuit output current of 40 nA, which are sufficient to drive NKN ReRAM devices. Stable switching properties with a large ON/OFF ratio of 102 are obtained from NKN ReRAM driven by NKN NG.
- 1 April 2016
- Published by Springer Nature
- p. 227-254
Nanomaterials-Based Skin-Like Electronics for the Unconscious and Continuous Monitoring of Body Status
- 1 April 2016
- Published by Springer Nature
- p. 227-254
Nanomaterials-Based Skin-Like Electronics for the Unconscious and Continuous Monitoring of Body Status
- 11 February 2016
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 16 (6) , 959-976
Soft implantable microelectrodes for future medicine: prosthetics, neural signal recording and neuromodulation
Soft based implantable devices have provided various potential diagnostic options and therapeutic methods in diverse medical fields.
- 11 February 2016
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 16 (6) , 959-976
Soft implantable microelectrodes for future medicine: prosthetics, neural signal recording and neuromodulation
Soft based implantable devices have provided various potential diagnostic options and therapeutic methods in diverse medical fields.
- 14 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 63 (1) , 138-147
Self-Adhesive and Capacitive Carbon Nanotube-Based Electrode to Record Electroencephalograph Signals From the Hairy Scalp
We fabricated a carbon nanotube (CNT)/adhesive polydimethylsiloxane (aPDMS) composite-based dry electroencephalograph (EEG) electrode for capacitive measuring of EEG signals. As research related to brain-computer interface applications has advanced, the presence of hairs on a patient's scalp has continued to present an obstacle to recorder EEG signals using dry electrodes. The CNT/aPDMS electrode developed here is elastic, highly conductive, self-adhesive, and capable of making conformal contact with and attaching to a hairy scalp. Onto the conductive disk, hundreds of conductive pillars coated with Parylene C insulation layer were fabricated. A CNT/aPDMS layer was attached on the disk to transmit biosignals to the pillar. The top of disk was designed to be solderable, which enables the electrode to connect with a variety of commercial EEG acquisition systems. The mechanical and electrical characteristics of the electrode were tested, and the performances of the electrodes were evaluated by recording EEGs, including alpha rhythms, auditory-evoked potentials, and steady-state visually-evoked potentials. The results revealed that the electrode provided a high signal-to-noise ratio with good tolerance for motion. Almost no leakage current was observed. Although preamplifiers with ultrahigh input impedance have been essential for previous capacitive electrodes, the EEGs were recorded here by directly connecting a commercially available EEG acquisition system to the electrode to yield high-quality signals comparable to those obtained using conventional wet electrodes.
- 14 September 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 63 (1) , 138-147
Self-Adhesive and Capacitive Carbon Nanotube-Based Electrode to Record Electroencephalograph Signals From the Hairy Scalp
We fabricated a carbon nanotube (CNT)/adhesive polydimethylsiloxane (aPDMS) composite-based dry electroencephalograph (EEG) electrode for capacitive measuring of EEG signals. As research related to brain-computer interface applications has advanced, the presence of hairs on a patient's scalp has continued to present an obstacle to recorder EEG signals using dry electrodes. The CNT/aPDMS electrode developed here is elastic, highly conductive, self-adhesive, and capable of making conformal contact with and attaching to a hairy scalp. Onto the conductive disk, hundreds of conductive pillars coated with Parylene C insulation layer were fabricated. A CNT/aPDMS layer was attached on the disk to transmit biosignals to the pillar. The top of disk was designed to be solderable, which enables the electrode to connect with a variety of commercial EEG acquisition systems. The mechanical and electrical characteristics of the electrode were tested, and the performances of the electrodes were evaluated by recording EEGs, including alpha rhythms, auditory-evoked potentials, and steady-state visually-evoked potentials. The results revealed that the electrode provided a high signal-to-noise ratio with good tolerance for motion. Almost no leakage current was observed. Although preamplifiers with ultrahigh input impedance have been essential for previous capacitive electrodes, the EEGs were recorded here by directly connecting a commercially available EEG acquisition system to the electrode to yield high-quality signals comparable to those obtained using conventional wet electrodes.