Paula Wahlgren
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Paula Wahlgren has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Per Delsing
Chalmers University of Technology
7 shared publications - Pär Johansson
Chalmers University of Technology
5 shared publications D. B. Haviland
Department of Physics, The Royal Institute of Technology, S-100 44 Stockholm, Sweden
3 shared publications- Liane Thuvander
Chalmers University of Technology
3 shared publications - Paula Femenías
Department of Architecture and Civil Engineering, Chalmers University of Technology, SE-412 96 Gothenburg, Sweden
3 shared publications R. J. Schoelkopf
Department of Applied Physics, Yale University, New Haven, Connecticut 06520
3 shared publications
Latest Publications
- Open Access
Exploring the Relationship between Environmental and Economic Payback Times, and Heritage Values in an Energy Renovation of a Multi-Residential Pre-War Building
Cultural value and heritage have been identified as necessary for a sustainable living environment, alongside environmental concern and energy efficiency. In this study, multiple methods, i.e., life cycle assessment, payback, and questionnaires and interviews with tenants, and empirical data from a recent energy renovation of a multi-residential pre-war building with wooden construction were used to analyse the impact of the renovation on cultural and aesthetic values, environmental impact, financial payback time, and user satisfaction. In the energy renovation, the façade, which had been disfigured in an earlier renovation, was recreated to resemble the original architecture. The main questions are: What impact has the recreation of the façade on the environmental payback time in comparison to a more conventional renovation? What are the consequences for the user satisfaction and financial return on investment? The results show that the recreated façade has improved the building’s aesthetics without compromising the environmental benefits. It also resulted in better thermal comfort, which is highly valued by the tenants. The improved aesthetics are also appreciated by the tenants, but to a lesser extent. Financially, the renovation is estimated to be not viable. Results of this study can be applied in the decision-making of similar renovation projects.
Open AccessExploring the Relationship between Environmental and Economic Payback Times, and Heritage Values in an Energy Renovation of a Multi-Residential Pre-War Building
Cultural value and heritage have been identified as necessary for a sustainable living environment, alongside environmental concern and energy efficiency. In this study, multiple methods, i.e., life cycle assessment, payback, and questionnaires and interviews with tenants, and empirical data from a recent energy renovation of a multi-residential pre-war building with wooden construction were used to analyse the impact of the renovation on cultural and aesthetic values, environmental impact, financial payback time, and user satisfaction. In the energy renovation, the façade, which had been disfigured in an earlier renovation, was recreated to resemble the original architecture. The main questions are: What impact has the recreation of the façade on the environmental payback time in comparison to a more conventional renovation? What are the consequences for the user satisfaction and financial return on investment? The results show that the recreated façade has improved the building’s aesthetics without compromising the environmental benefits. It also resulted in better thermal comfort, which is highly valued by the tenants. The improved aesthetics are also appreciated by the tenants, but to a lesser extent. Financially, the renovation is estimated to be not viable. Results of this study can be applied in the decision-making of similar renovation projects.
- Open Access
- 30 June 2020
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 172, 23005
Deterioration in brick buildings: hygrothermal performance and measures to save them
Many former industrial building sites in Sweden have been abandoned and left to deteriorate. Nowadays, there is a large interest to refurbish and retrofit these buildings for other purposes. Commercial and housing developers are attracted to these areas which are often in the outskirts of the city centers. There are several challenges facing architects and engineers to preserve these buildings, also connected to cultural heritage demands. The aim of this study is to propose measures to preserve cultural heritage buildings. A brick building in Gothenburg, on the Swedish west coast, is used as a case study. The building was used for paper production until 2005. After that, it deteriorated quickly after the heating was turned off. The rapid decay affected the hygrothermal performance as well as the load-bearing capacity of the structure. Small scale laboratory investigations of the building materials show a high degree of decay. Measurements of temperature and relative humidity is used to monitor the hygrothermal performance. Observations show that the brick masonry has heavy salt efflorescence and is in need of further protective measures.
- 30 June 2020
- Published by EDP Sciences in E3S Web of Conferences
- Vol. 172, 23005
Open AccessDeterioration in brick buildings: hygrothermal performance and measures to save them
Many former industrial building sites in Sweden have been abandoned and left to deteriorate. Nowadays, there is a large interest to refurbish and retrofit these buildings for other purposes. Commercial and housing developers are attracted to these areas which are often in the outskirts of the city centers. There are several challenges facing architects and engineers to preserve these buildings, also connected to cultural heritage demands. The aim of this study is to propose measures to preserve cultural heritage buildings. A brick building in Gothenburg, on the Swedish west coast, is used as a case study. The building was used for paper production until 2005. After that, it deteriorated quickly after the heating was turned off. The rapid decay affected the hygrothermal performance as well as the load-bearing capacity of the structure. Small scale laboratory investigations of the building materials show a high degree of decay. Measurements of temperature and relative humidity is used to monitor the hygrothermal performance. Observations show that the brick masonry has heavy salt efflorescence and is in need of further protective measures.
- Open Access
Experimental Study of Thermal Buoyancy in the Cavity of Ventilated Roofs
Pitched wooden roofs are ventilated through an air cavity beneath the roofing in order to remove heat and moisture from the roof construction. The ventilation is driven by wind pressure and thermal buoyancy. This paper studies ventilation driven by thermal buoyancy in the air cavity of inclined roofs. The influence of air cavity design and roof inclination on the airflow is investigated. Laboratory measurements were carried out on an inclined full-scale roof model with an air cavity heated on one side in order to simulate solar radiation on a roof surface. Equipment to measure temperature was installed in the roof model, while air velocity in the cavity was determined by smoke tests. Combinations of different roof inclinations, air cavity heights and applied heating power on the air cavity top surface were examined. The study showed that increased air cavity height led to increased airflow and decreased surface temperatures in the air cavity. Increased roof inclination and heating power applied to the roofing also increased the airflow. The investigations imply that thermal buoyancy in the air cavity of pitched roofs could be a relevant driving force for cavity ventilation and important to consider when evaluating the heat and moisture performance of such a construction.
Open AccessExperimental Study of Thermal Buoyancy in the Cavity of Ventilated Roofs
Pitched wooden roofs are ventilated through an air cavity beneath the roofing in order to remove heat and moisture from the roof construction. The ventilation is driven by wind pressure and thermal buoyancy. This paper studies ventilation driven by thermal buoyancy in the air cavity of inclined roofs. The influence of air cavity design and roof inclination on the airflow is investigated. Laboratory measurements were carried out on an inclined full-scale roof model with an air cavity heated on one side in order to simulate solar radiation on a roof surface. Equipment to measure temperature was installed in the roof model, while air velocity in the cavity was determined by smoke tests. Combinations of different roof inclinations, air cavity heights and applied heating power on the air cavity top surface were examined. The study showed that increased air cavity height led to increased airflow and decreased surface temperatures in the air cavity. Increased roof inclination and heating power applied to the roofing also increased the airflow. The investigations imply that thermal buoyancy in the air cavity of pitched roofs could be a relevant driving force for cavity ventilation and important to consider when evaluating the heat and moisture performance of such a construction.
- 12 December 2018
- Published by Springer Nature
- p. 291-301
Renovating the Housing Stock Built Before 1945: Exploring the Relations Between Energy Efficiency, Embodied Energy and Heritage Values
- 12 December 2018
- Published by Springer Nature
- p. 291-301
Renovating the Housing Stock Built Before 1945: Exploring the Relations Between Energy Efficiency, Embodied Energy and Heritage Values
- Open Access
- 1 October 2017
- Published by Elsevier in Energy Procedia
- Vol. 132, 873-878
Consequences of Varying Airtightness in Wooden Buildings
- 1 October 2017
- Published by Elsevier in Energy Procedia
- Vol. 132, 873-878
Open AccessConsequences of Varying Airtightness in Wooden Buildings
- Open Access
- 1 October 2017
- Published by Elsevier in Energy Procedia
- Vol. 132, 951-956
Renovation of buildings from before 1945: status assessment and energy efficiency measures
- 1 October 2017
- Published by Elsevier in Energy Procedia
- Vol. 132, 951-956
Open AccessRenovation of buildings from before 1945: status assessment and energy efficiency measures
- Open Access
- 1 September 2016
- Published by Elsevier in Energy Procedia
- Vol. 96, 170-179
Pending for Renovations: Understanding the Conditions of the Multi-family Housing Stock from before 1945
- 1 September 2016
- Published by Elsevier in Energy Procedia
- Vol. 96, 170-179
Open AccessPending for Renovations: Understanding the Conditions of the Multi-family Housing Stock from before 1945
- Open Access
- 1 November 2015
- Published by Elsevier in Energy Procedia
- Vol. 78, 1419-1424
Hygrothermal Performance of a Light Weight Timber Wall Assembly with an Exterior air Barrier
- 1 November 2015
- Published by Elsevier in Energy Procedia
- Vol. 78, 1419-1424
Open AccessHygrothermal Performance of a Light Weight Timber Wall Assembly with an Exterior air Barrier
- Open Access
- 1 November 2015
- Published by Elsevier in Energy Procedia
- Vol. 78, 376-381
Effect from a Variable U-Value in Adaptive Building Components with Controlled Internal Air Pressure
- 1 November 2015
- Published by Elsevier in Energy Procedia
- Vol. 78, 376-381
Open AccessEffect from a Variable U-Value in Adaptive Building Components with Controlled Internal Air Pressure
- 1 April 2007
- Published by SAGE Publications in Journal of Building Physics
- Vol. 30 (4) , 351-370
Overview and Literature Survey of Natural and Forced Convection in Attic Insulation
This article presents an overview and a literature survey of convection in attic insulation. The study focuses on the onset of natural convection in the insulation, but also discusses the influence of forced convection. It covers experimental studies in small-scale measurement apparatus, large-scale laboratory measurements, in situ measurements, as well as numerical and theoretical work on convection in attic insulation. Suggestions for future work are also presented.
- 1 April 2007
- Published by SAGE Publications in Journal of Building Physics
- Vol. 30 (4) , 351-370
Overview and Literature Survey of Natural and Forced Convection in Attic Insulation
This article presents an overview and a literature survey of convection in attic insulation. The study focuses on the onset of natural convection in the insulation, but also discusses the influence of forced convection. It covers experimental studies in small-scale measurement apparatus, large-scale laboratory measurements, in situ measurements, as well as numerical and theoretical work on convection in attic insulation. Suggestions for future work are also presented.