Elena Bergamini
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Elena Bergamini has a total of 165 co-authors. Here are the top co-authors by number of shared publications:
- Giuseppe Vannozzi
Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, P.zza Lauro de Bosis 15, 00135 Rome, Italy
25 shared publications - Marco Tramontano
Alma Mater Studiorum University of Bologna
10 shared publications - Valentina Camomilla
Department of Human Movement and Health Science, University of Rome “Foro Italico”, 00135 Rome, Italy
8 shared publications - Hélène Pillet
Arts et Métiers Institute of Technology, Université Sorbonne Paris Nord, IBHGC - Institut de Biomécanique Humaine Georges Charpak, HESAM Université, Paris, F-75013, France
7 shared publications - Valeria Belluscio
Department of Movement, Human and Health Sciences, University of Rome “Foro Italico”, P.zza Lauro de Bosis 15, 00135 Rome, Italy
7 shared publications Aurelio Cappozzo
Interuniversity Centre of Bioengineering of the Human Neuromusculoskeletal System (BOHNES), Department of Movement, Human and Health Sciences, University of Rome "Foro Italico", Rome, Italy
6 shared publications
Latest Publications
- Open Access
- 19 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
Accurate 3D Motion Tracking Based on Radar Distributed Network
This article examines the feasibility of measuring the three-dimensional (3D) displacement of moving targets using a distributed network of three 24 GHz Doppler radars positioned along orthogonal axes. Though radar sensors offer advantages over optical sensors in terms of cost and privacy, conventional phase-based estimation fails during stationary periods or with multi-component targets. To address these issues, this work proposes a displacement detection method based on an ad-hoc experimental setup and the micro-Doppler signature. A curve extraction algorithm isolates the different body parts, which are then integrated over time to determine displacement. The proposed method is validated through both simulation and measurements and supported by a stereophotogrammetric system as ground truth. The system's effectiveness was further demonstrated through a proof-of-concept human walking trial, proving that micro-Doppler analysis can overcome the limitations of classical phase-based methods in biomechanical applications.
- 19 May 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. PP (1530437X) , 1
Open AccessAccurate 3D Motion Tracking Based on Radar Distributed Network
This article examines the feasibility of measuring the three-dimensional (3D) displacement of moving targets using a distributed network of three 24 GHz Doppler radars positioned along orthogonal axes. Though radar sensors offer advantages over optical sensors in terms of cost and privacy, conventional phase-based estimation fails during stationary periods or with multi-component targets. To address these issues, this work proposes a displacement detection method based on an ad-hoc experimental setup and the micro-Doppler signature. A curve extraction algorithm isolates the different body parts, which are then integrated over time to determine displacement. The proposed method is validated through both simulation and measurements and supported by a stereophotogrammetric system as ground truth. The system's effectiveness was further demonstrated through a proof-of-concept human walking trial, proving that micro-Doppler analysis can overcome the limitations of classical phase-based methods in biomechanical applications.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 1
Detecting Rowing Strokes Faults with a Single On-Body Inertial Sensor
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (16) , 1
Detecting Rowing Strokes Faults with a Single On-Body Inertial Sensor
- Open Access
Test-Retest Reliability and Minimal Detectable Changes for Wearable Sensor-Derived Gait Stability, Symmetry, and Smoothness in Individuals with Severe Traumatic Brain Injury
Severe traumatic brain injury (sTBI) often results in significant impairments in gait stability, symmetry, and smoothness. Inertial measurement units (IMUs) have emerged as powerful tools to quantify these aspects of gait, but their clinometric properties in sTBI populations remain underexplored. This study aimed to assess the test-retest reliability and minimal detectable change (MDC) of three IMU-derived indices—normalized Root Mean Square (nRMS), improved Harmonic Ratio (iHR), and Log Dimensionless Jerk (LDLJ)—during a 10 m walking test for sTBI survivors. Forty-nine participants with sTBI completed the walking test, with IMUs placed on key body segments to capture accelerations and angular velocities. Test-retest analyses revealed moderate to excellent reliability for nRMS and iHR in anteroposterior (ICC: 0.78–0.95 and 0.94, respectively) and craniocaudal directions (ICC: 0.95), with small MDC values, supporting their clinical applicability (MDC: 0.04–0.3). However, iHR in the mediolateral direction exhibited greater variability (ICC: 0.80; MDC: 9.74), highlighting potential sensitivity challenges. LDLJ metrics showed moderate reliability (ICC: 0.57–0.77) and higher MDC values (0.55–0.75), suggesting the need for further validation. These findings underscore the reliability and sensitivity of specific IMU-derived indices in detecting meaningful gait changes in sTBI survivors, paving the way for refined assessments and monitoring the rehabilitation process of sTBI survivors. Future research should explore these indices’ responsiveness to interventions and their correlation with functional outcomes.
Open AccessTest-Retest Reliability and Minimal Detectable Changes for Wearable Sensor-Derived Gait Stability, Symmetry, and Smoothness in Individuals with Severe Traumatic Brain Injury
Severe traumatic brain injury (sTBI) often results in significant impairments in gait stability, symmetry, and smoothness. Inertial measurement units (IMUs) have emerged as powerful tools to quantify these aspects of gait, but their clinometric properties in sTBI populations remain underexplored. This study aimed to assess the test-retest reliability and minimal detectable change (MDC) of three IMU-derived indices—normalized Root Mean Square (nRMS), improved Harmonic Ratio (iHR), and Log Dimensionless Jerk (LDLJ)—during a 10 m walking test for sTBI survivors. Forty-nine participants with sTBI completed the walking test, with IMUs placed on key body segments to capture accelerations and angular velocities. Test-retest analyses revealed moderate to excellent reliability for nRMS and iHR in anteroposterior (ICC: 0.78–0.95 and 0.94, respectively) and craniocaudal directions (ICC: 0.95), with small MDC values, supporting their clinical applicability (MDC: 0.04–0.3). However, iHR in the mediolateral direction exhibited greater variability (ICC: 0.80; MDC: 9.74), highlighting potential sensitivity challenges. LDLJ metrics showed moderate reliability (ICC: 0.57–0.77) and higher MDC values (0.55–0.75), suggesting the need for further validation. These findings underscore the reliability and sensitivity of specific IMU-derived indices in detecting meaningful gait changes in sTBI survivors, paving the way for refined assessments and monitoring the rehabilitation process of sTBI survivors. Future research should explore these indices’ responsiveness to interventions and their correlation with functional outcomes.
- Open Access
Smooth Moves: Comparing Log Dimensionless Jerk Metrics from Body Center of Mass Trajectory and Wearable Sensor Acceleration During Walking
Movement smoothness is a critical metric for evaluating motor control and sensorimotor impairments, with increasing relevance in neurorehabilitation and everyday functional assessments. This study investigates the correlation between two smoothness metrics (Log Dimensionless Jerk): LDLJV, derived from body center of mass (BCoM) trajectories using a gold-standard stereophotogrammetric system, and LDLJA, calculated from acceleration data recorded via an inertial measurement unit (IMU) placed at the L1–L2 level. Ten healthy adults (six men and four women; height: 1.71 ± 0.08 m; body mass: 68.2 ± 10.2 kg; age: 34.5 ± 8.5 years) walked on a treadmill at seven different speeds, with stride-specific data analyzed to compute smoothness indices for three anatomical components (antero-posterior, medio-lateral, cranio-caudal). Concordance between the metrics was evaluated using Bland–Altman analysis, Spearman’s correlation, and the mean absolute percentage error. The results revealed weak correlations and substantial biases across all components and speeds, reflecting inherent differences between IMU- and BCoM-derived data. Correcting biases improved alignment but did not eliminate discrepancies. The findings highlight that LDLJA captures only localized trunk accelerations, whereas BCoM-derived LDLJV approximates whole-body dynamics, making direct substitution infeasible. This study emphasizes the need for careful interpretation of IMU-based metrics and contributes to refining their application in real-world gait analyses.
Open AccessSmooth Moves: Comparing Log Dimensionless Jerk Metrics from Body Center of Mass Trajectory and Wearable Sensor Acceleration During Walking
Movement smoothness is a critical metric for evaluating motor control and sensorimotor impairments, with increasing relevance in neurorehabilitation and everyday functional assessments. This study investigates the correlation between two smoothness metrics (Log Dimensionless Jerk): LDLJV, derived from body center of mass (BCoM) trajectories using a gold-standard stereophotogrammetric system, and LDLJA, calculated from acceleration data recorded via an inertial measurement unit (IMU) placed at the L1–L2 level. Ten healthy adults (six men and four women; height: 1.71 ± 0.08 m; body mass: 68.2 ± 10.2 kg; age: 34.5 ± 8.5 years) walked on a treadmill at seven different speeds, with stride-specific data analyzed to compute smoothness indices for three anatomical components (antero-posterior, medio-lateral, cranio-caudal). Concordance between the metrics was evaluated using Bland–Altman analysis, Spearman’s correlation, and the mean absolute percentage error. The results revealed weak correlations and substantial biases across all components and speeds, reflecting inherent differences between IMU- and BCoM-derived data. Correcting biases improved alignment but did not eliminate discrepancies. The findings highlight that LDLJA captures only localized trunk accelerations, whereas BCoM-derived LDLJV approximates whole-body dynamics, making direct substitution infeasible. This study emphasizes the need for careful interpretation of IMU-based metrics and contributes to refining their application in real-world gait analyses.
- Open Access
- 3 February 2025
- Published by Aboutscience Srl in Archives of Physiotherapy
- Vol. 15, 9-18
Discriminative ability, responsiveness, and interpretability of smoothness index of gait in people with multiple sclerosis
Introduction: Gait impairments are common in People with Multiple Sclerosis (PwMS). Several studies have examined the clinometric properties of Inertial Measurement Units (IMUs), with LDLJa identified as a robust metric for gait smoothness. However, its responsiveness and interpretability have not been explored. Methods: This cross-sectional study at IRCCS Santa Lucia Hospital enrolled 44 PwMS (age: 28-71; EDSS: 0-6) and 43 age- and gait-speed-matched healthy participants (HP). Two physiotherapists conducted assessments with five synchronized IMUs during a 10-meter walk at participants’ preferred speed. Data were collected at baseline (T0) and after 4 weeks of training (T1). Results: Significant differences in log dimensionless jerk (LDLJa) were found between PwMS and HP in the AP (p < 0.001, d = 0.63), ML (p < 0.001, d = 1.08), and CC (p = 0.03, d = 0.68) directions. PwMS had lower LDLJaAP values (< -4.88) and LDLJaML values (< -5.40) with probabilities of 63% and 76%, respectively. ΔLDLJaML demonstrated good responsiveness to rehabilitation (AUC ~0.80), with improvements >4.02% representing the optimal MCID for clinical improvement in MiniBesTest. Conclusion: Lower LDLJa values in the AP and ML directions characterize gait smoothness impairment in PwMS. LDLJa in the ML direction is responsive to balance-focused rehabilitation, highlighting its potential for tracking gait disorders and rehabilitation progress.
- 3 February 2025
- Published by Aboutscience Srl in Archives of Physiotherapy
- Vol. 15, 9-18
Open AccessDiscriminative ability, responsiveness, and interpretability of smoothness index of gait in people with multiple sclerosis
Introduction: Gait impairments are common in People with Multiple Sclerosis (PwMS). Several studies have examined the clinometric properties of Inertial Measurement Units (IMUs), with LDLJa identified as a robust metric for gait smoothness. However, its responsiveness and interpretability have not been explored. Methods: This cross-sectional study at IRCCS Santa Lucia Hospital enrolled 44 PwMS (age: 28-71; EDSS: 0-6) and 43 age- and gait-speed-matched healthy participants (HP). Two physiotherapists conducted assessments with five synchronized IMUs during a 10-meter walk at participants’ preferred speed. Data were collected at baseline (T0) and after 4 weeks of training (T1). Results: Significant differences in log dimensionless jerk (LDLJa) were found between PwMS and HP in the AP (p < 0.001, d = 0.63), ML (p < 0.001, d = 1.08), and CC (p = 0.03, d = 0.68) directions. PwMS had lower LDLJaAP values (< -4.88) and LDLJaML values (< -5.40) with probabilities of 63% and 76%, respectively. ΔLDLJaML demonstrated good responsiveness to rehabilitation (AUC ~0.80), with improvements >4.02% representing the optimal MCID for clinical improvement in MiniBesTest. Conclusion: Lower LDLJa values in the AP and ML directions characterize gait smoothness impairment in PwMS. LDLJa in the ML direction is responsive to balance-focused rehabilitation, highlighting its potential for tracking gait disorders and rehabilitation progress.
- 6 November 2024
- Published by SAGE Publications in Journal of Vestibular Research
- Vol. 35 (2) , 82-90
Dynamic postural stability, symmetry, and smoothness of gait in patients with persistent postural-perceptual dizziness
Background: Patients with persistent postural-perceptual dizziness (PPPD) exhibit altered postural and gait dynamics, but development of these changes following precipitating illnesses is poorly understood. Objective: To compare posture and gait metrics in patients with PPPD or subacute unilateral vestibulopathies (sAUVP) to healthy controls (HC). Methods: Ten patients with sAUVP, nine with PPPD, and eleven HC completed the 10 Meters Walk Test (10MWT) (an eyes open task) and Fukuda Stepping Test (FST) (an eyes closed task). Gait stability, symmetry, and smoothness were compared among groups and correlated with Dizziness Handicap Inventory (DHI) scores. Results: 10MWT – Patients with PPPD had lower pelvis stability and gait symmetry than HCs. Patients with sAUVP had only lower pelvis stability. FST – Patients with PPPD and sAUVP had lower gait smoothness than HCs. Patients with sAUVP also had lower gait symmetry. Among patients with PPPD, DHI scores correlated positively with head stability. Conclusions: PPPD and sAUVP caused abnormal pelvis stability when walking and gait smoothness when stepping but differed in effects on gait symmetry with the presence/absence of visual inputs. For PPPD, visual stimuli had destabilizing effects, whereas for sAUVP vision aided stability. Symptom severity in patients with PPPD was related to head stability.
- 6 November 2024
- Published by SAGE Publications in Journal of Vestibular Research
- Vol. 35 (2) , 82-90
Dynamic postural stability, symmetry, and smoothness of gait in patients with persistent postural-perceptual dizziness
Background: Patients with persistent postural-perceptual dizziness (PPPD) exhibit altered postural and gait dynamics, but development of these changes following precipitating illnesses is poorly understood. Objective: To compare posture and gait metrics in patients with PPPD or subacute unilateral vestibulopathies (sAUVP) to healthy controls (HC). Methods: Ten patients with sAUVP, nine with PPPD, and eleven HC completed the 10 Meters Walk Test (10MWT) (an eyes open task) and Fukuda Stepping Test (FST) (an eyes closed task). Gait stability, symmetry, and smoothness were compared among groups and correlated with Dizziness Handicap Inventory (DHI) scores. Results: 10MWT – Patients with PPPD had lower pelvis stability and gait symmetry than HCs. Patients with sAUVP had only lower pelvis stability. FST – Patients with PPPD and sAUVP had lower gait smoothness than HCs. Patients with sAUVP also had lower gait symmetry. Among patients with PPPD, DHI scores correlated positively with head stability. Conclusions: PPPD and sAUVP caused abnormal pelvis stability when walking and gait smoothness when stepping but differed in effects on gait symmetry with the presence/absence of visual inputs. For PPPD, visual stimuli had destabilizing effects, whereas for sAUVP vision aided stability. Symptom severity in patients with PPPD was related to head stability.
- Open Access
- 22 August 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-10
Walking symmetry is speed and index dependent
Gait symmetry is one of the most informative aspects describing the quality of gait. Many indices have been proposed to quantify gait symmetry. Among them, indices focusing on the comparison of the two body sides (e.g., Symmetry Angle, SA) and indices based on the analysis of the locomotor act as a whole, dealing with the body center of mass (e.g., Symmetry Index, SIBCoM) or lower trunk accelerometry (e.g., improved Harmonic Ratio, iHR) have been proposed. Remarkably, the relationship between these indices has received little attention so far, as well as the influence of gait speed on their values. The aim of this study is to investigate this relationship by comparing the SA, SIBCoM, and iHR, and to explore the effect of walking speed on these indices. Ten healthy adults walked for 60 s on a treadmill at seven different speeds (from 0.28 to 1.95 m s−1) and simulate an asymmetric gait (ASYM) at 0.83 m s−1. Marker-based trajectories were recorded, and the body center of mass 3D trajectory was obtained. Simultaneously, lower trunk 3D linear accelerations were collected using a triaxial accelerometer. SIBCoM, iHR, and SA were calculated for each stride, each anatomical direction, and each condition. Perfect symmetry was never displayed in any axes and any indices. Significant differences existed between SIBCoM, and iHR in all anatomical directions (p < 0.0001). The walking speed significantly affected SIBCoM and iHR values in anteroposterior and craniocaudal directions, but not in mediolateral. Conversely, no walking speed effect was found for SA (p = 0.28). All three indices significantly discriminated between ASYM and the corresponding walking condition (p < 0.05). Gait symmetry may differ significantly according to the data source, mathematical approach, and walking speed. Healthy individuals display an asymmetrical gait and acknowledging this aspect is crucial when establishing rehabilitation objectives and assessing the quality of gait in the clinical setting.
- 22 August 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-10
Open AccessWalking symmetry is speed and index dependent
Gait symmetry is one of the most informative aspects describing the quality of gait. Many indices have been proposed to quantify gait symmetry. Among them, indices focusing on the comparison of the two body sides (e.g., Symmetry Angle, SA) and indices based on the analysis of the locomotor act as a whole, dealing with the body center of mass (e.g., Symmetry Index, SIBCoM) or lower trunk accelerometry (e.g., improved Harmonic Ratio, iHR) have been proposed. Remarkably, the relationship between these indices has received little attention so far, as well as the influence of gait speed on their values. The aim of this study is to investigate this relationship by comparing the SA, SIBCoM, and iHR, and to explore the effect of walking speed on these indices. Ten healthy adults walked for 60 s on a treadmill at seven different speeds (from 0.28 to 1.95 m s−1) and simulate an asymmetric gait (ASYM) at 0.83 m s−1. Marker-based trajectories were recorded, and the body center of mass 3D trajectory was obtained. Simultaneously, lower trunk 3D linear accelerations were collected using a triaxial accelerometer. SIBCoM, iHR, and SA were calculated for each stride, each anatomical direction, and each condition. Perfect symmetry was never displayed in any axes and any indices. Significant differences existed between SIBCoM, and iHR in all anatomical directions (p < 0.0001). The walking speed significantly affected SIBCoM and iHR values in anteroposterior and craniocaudal directions, but not in mediolateral. Conversely, no walking speed effect was found for SA (p = 0.28). All three indices significantly discriminated between ASYM and the corresponding walking condition (p < 0.05). Gait symmetry may differ significantly according to the data source, mathematical approach, and walking speed. Healthy individuals display an asymmetrical gait and acknowledging this aspect is crucial when establishing rehabilitation objectives and assessing the quality of gait in the clinical setting.
- 3 July 2024
- Published by Wolters Kluwer Health in American Journal of Physical Medicine & Rehabilitation
- Vol. 104 (1) , 89-100
Evaluation of the Bilateral Symmetry Assumption in Manual Wheelchair Propulsion
This systematic review aimed to 1) verify bilateral symmetry assumption in manual wheelchair propulsion in daily life and sports, and its relationship with injury risk and sports performance, and 2) evaluate methods for assessing bilateral symmetry. Scopus, Web of Science, PubMed, and EBSCO databases were searched for articles published before January 2024 investigating bilateral symmetry in manual wheelchair users and/or healthy participants during manual wheelchair propulsion. Two independent reviewers screened, extracted data, and assessed methodological quality of retrieved papers. Twenty-five studies were included. In daily ground-level propulsion, minimal asymmetries were observed in kinematic, kinetic, and temporal parameters when averaging three or more push cycles. In the sports context, diverse findings emerged, ranging from up to 27% side-to-side differences in propulsion kinetics and kinematics during sprinting, to descriptions of both symmetrical and asymmetrical upper limb motions. Limited evidence exists regarding the role of asymmetry in manual wheelchair propulsion as a risk factor for injury and pain, as well as the association between sprinting performance and symmetry. In conclusion, bilateral symmetry assumption in manual wheelchair propulsion is valid only under specific conditions (i.e., slow/moderate speed, averaging ≥3 push cycles, smooth level ground). The wheeling environment and interindividual variability impact symmetry research outcome and require consideration in future studies.
- 3 July 2024
- Published by Wolters Kluwer Health in American Journal of Physical Medicine & Rehabilitation
- Vol. 104 (1) , 89-100
Evaluation of the Bilateral Symmetry Assumption in Manual Wheelchair Propulsion
This systematic review aimed to 1) verify bilateral symmetry assumption in manual wheelchair propulsion in daily life and sports, and its relationship with injury risk and sports performance, and 2) evaluate methods for assessing bilateral symmetry. Scopus, Web of Science, PubMed, and EBSCO databases were searched for articles published before January 2024 investigating bilateral symmetry in manual wheelchair users and/or healthy participants during manual wheelchair propulsion. Two independent reviewers screened, extracted data, and assessed methodological quality of retrieved papers. Twenty-five studies were included. In daily ground-level propulsion, minimal asymmetries were observed in kinematic, kinetic, and temporal parameters when averaging three or more push cycles. In the sports context, diverse findings emerged, ranging from up to 27% side-to-side differences in propulsion kinetics and kinematics during sprinting, to descriptions of both symmetrical and asymmetrical upper limb motions. Limited evidence exists regarding the role of asymmetry in manual wheelchair propulsion as a risk factor for injury and pain, as well as the association between sprinting performance and symmetry. In conclusion, bilateral symmetry assumption in manual wheelchair propulsion is valid only under specific conditions (i.e., slow/moderate speed, averaging ≥3 push cycles, smooth level ground). The wheeling environment and interindividual variability impact symmetry research outcome and require consideration in future studies.
- Open Access
Dynamic Stability, Symmetry, and Smoothness of Gait in People with Neurological Health Conditions
Neurological disorders such as stroke, Parkinson’s disease (PD), and severe traumatic brain injury (sTBI) are leading global causes of disability and mortality. This study aimed to assess the ability to walk of patients with sTBI, stroke, and PD, identifying the differences in dynamic postural stability, symmetry, and smoothness during various dynamic motor tasks. Sixty people with neurological disorders and 20 healthy participants were recruited. Inertial measurement unit (IMU) sensors were employed to measure spatiotemporal parameters and gait quality indices during different motor tasks. The Mini-BESTest, Berg Balance Scale, and Dynamic Gait Index Scoring were also used to evaluate balance and gait. People with stroke exhibited the most compromised biomechanical patterns, with lower walking speed, increased stride duration, and decreased stride frequency. They also showed higher upper body instability and greater variability in gait stability indices, as well as less gait symmetry and smoothness. PD and sTBI patients displayed significantly different temporal parameters and differences in stability parameters only at the pelvis level and in the smoothness index during both linear and curved paths. This study provides a biomechanical characterization of dynamic stability, symmetry, and smoothness in people with stroke, sTBI, and PD using an IMU-based ecological assessment.
Open AccessDynamic Stability, Symmetry, and Smoothness of Gait in People with Neurological Health Conditions
Neurological disorders such as stroke, Parkinson’s disease (PD), and severe traumatic brain injury (sTBI) are leading global causes of disability and mortality. This study aimed to assess the ability to walk of patients with sTBI, stroke, and PD, identifying the differences in dynamic postural stability, symmetry, and smoothness during various dynamic motor tasks. Sixty people with neurological disorders and 20 healthy participants were recruited. Inertial measurement unit (IMU) sensors were employed to measure spatiotemporal parameters and gait quality indices during different motor tasks. The Mini-BESTest, Berg Balance Scale, and Dynamic Gait Index Scoring were also used to evaluate balance and gait. People with stroke exhibited the most compromised biomechanical patterns, with lower walking speed, increased stride duration, and decreased stride frequency. They also showed higher upper body instability and greater variability in gait stability indices, as well as less gait symmetry and smoothness. PD and sTBI patients displayed significantly different temporal parameters and differences in stability parameters only at the pelvis level and in the smoothness index during both linear and curved paths. This study provides a biomechanical characterization of dynamic stability, symmetry, and smoothness in people with stroke, sTBI, and PD using an IMU-based ecological assessment.