Wei Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Wei Peng has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Guoxiang Li
School of Nuclear Science, Energy and Power Engineering, Shandong University, Jinan 250061, China
2 shared publications - Jie Geng
School of Energy and Power Engineering, Shandong University, Jinan, China
2 shared publications - Wei Yan
School of Nuclear Science, Energy and Power Engineering, Shandong University, Jinan 250061, China
2 shared publications - Chengdong Li
School of Information and Electrical Engineering, Shandong Jianzhu University, Jinan, China
1 shared publication - Hanyuan Zhang
School of Information and Electrical Engineering, Shandong Jianzhu University, Jinan 250101, China
1 shared publication - Ruiqi Wang
State Grid Corporation of China, Shandong Electric Power Research Institute, Jinan, China
1 shared publication
Latest Publications
- 4 June 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 56, 104718
Images based fault diagnosis of air handling unit via combining kernel slow feature analysis and deep learning method
- 4 June 2022
- Published by Elsevier in Journal of Building Engineering
- Vol. 56, 104718
Images based fault diagnosis of air handling unit via combining kernel slow feature analysis and deep learning method
- 2 January 2018
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 18 (1) , 64-78
A strategy for the partition of MRF zones in axial fan simulation
In axial fan simulation using multiple reference frame (MRF) method, an inappropriate size of rotating zone may affect the accuracy of results. In order to study the influence of axial and radial sizes in a wide flow rate range, five rotating zone sizes were investigated at seven flow rate points from 0 to 11.3 m3/s in a simplified fan setup configuration. Comparing the fan characteristic curves, it is found that the accuracy of simulation results is sensitive both to axial size and radial size, and the sensitivity varies with flow rates. In order to accurately predict the fan performance, it is recommended that the MRF rotating zone be long enough to cover the rotating backflow and pre-rotation area upstream the fan for prediction at low flow rates, and the radial size of MRF zone be large enough to include the trailing vortexes for prediction at middle to high flow rates. While the other sizes are not very influential, as long as the integrity of the blades is included.
- 2 January 2018
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 18 (1) , 64-78
A strategy for the partition of MRF zones in axial fan simulation
In axial fan simulation using multiple reference frame (MRF) method, an inappropriate size of rotating zone may affect the accuracy of results. In order to study the influence of axial and radial sizes in a wide flow rate range, five rotating zone sizes were investigated at seven flow rate points from 0 to 11.3 m3/s in a simplified fan setup configuration. Comparing the fan characteristic curves, it is found that the accuracy of simulation results is sensitive both to axial size and radial size, and the sensitivity varies with flow rates. In order to accurately predict the fan performance, it is recommended that the MRF rotating zone be long enough to cover the rotating backflow and pre-rotation area upstream the fan for prediction at low flow rates, and the radial size of MRF zone be large enough to include the trailing vortexes for prediction at middle to high flow rates. While the other sizes are not very influential, as long as the integrity of the blades is included.
- 29 December 2017
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 17 (4) , 240-255
An iterative correction method for the input fan curve in an actuator disk model
The 3D fan zone model is a recently developed variant of the actuator disk models, based on an input fan curve to simulate the fan effect. However, the fan curves are typically obtained in experimental situations under common standards, which could be different from the operating scenario in simulation, specifically, the definitions of flowrate and the fan appurtenances effect. In order to adapt the typical fan curve for the 3D fan zone model, an iterative correction method to modify the flowrate and exclude the fan appurtenances effect was proposed. The embedded evaluation method for fan appurtenances effect was improved by taking the fan effect into account. To verify, the iterative correction method was applied to an axial cooling fan simulation. With corrected fan curve, the maximum deviation of fan total pressure reduced from 282.6 to 0.7 Pa. The iterative correction method of fan curve is highly recommended.
- 29 December 2017
- Published by Taylor & Francis in International Journal of Ventilation
- Vol. 17 (4) , 240-255
An iterative correction method for the input fan curve in an actuator disk model
The 3D fan zone model is a recently developed variant of the actuator disk models, based on an input fan curve to simulate the fan effect. However, the fan curves are typically obtained in experimental situations under common standards, which could be different from the operating scenario in simulation, specifically, the definitions of flowrate and the fan appurtenances effect. In order to adapt the typical fan curve for the 3D fan zone model, an iterative correction method to modify the flowrate and exclude the fan appurtenances effect was proposed. The embedded evaluation method for fan appurtenances effect was improved by taking the fan effect into account. To verify, the iterative correction method was applied to an axial cooling fan simulation. With corrected fan curve, the maximum deviation of fan total pressure reduced from 282.6 to 0.7 Pa. The iterative correction method of fan curve is highly recommended.