Ana Isabel Santos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ana Isabel Santos has a total of 231 co-authors. Here are the top co-authors by number of shared publications:
- Nuno Matela
Instituto de Biofísica e Engenharia Biomédica, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal
8 shared publications - Pedro Almeida
Instituto de Biofísica e Engenharia Biomédica, Faculdade de Ciências, Universidade de Lisboa, 1749-016 Lisboa, Portugal
8 shared publications - Catarina Ortigãao
LIP - Laboratório de Instrumentação e Física Experimental de Partículas, Lisboa, Portugal
7 shared publications - Joao Varela
Laboratório de Instrumentação e Física Experimental de Partículas
7 shared publications - Nuno C. Ferreira
University of Coimbra
7 shared publications A. Trindade
LIP, Lisboa, Portugal
6 shared publications
Latest Publications
- 1 January 2020
- Published by European Association of Nuclear Medicine
European Nuclear Medicine Guide
The European Nuclear Medicine Guide offers a thorough overview of a wide variety of topics related to nuclear medicine for professionals in the field, including: Nuclear medicine-related basic science and technical procedures In vivo imaging with radiopharmaceuticals Hybrid/multimodality imaging Radionuclide-guided surgery Dosimetry Radionuclide therapy Techniques related to nuclear physics in medicine Medical applications of radiobiology and radiation protection
- 1 January 2020
- Published by European Association of Nuclear Medicine
European Nuclear Medicine Guide
The European Nuclear Medicine Guide offers a thorough overview of a wide variety of topics related to nuclear medicine for professionals in the field, including: Nuclear medicine-related basic science and technical procedures In vivo imaging with radiopharmaceuticals Hybrid/multimodality imaging Radionuclide-guided surgery Dosimetry Radionuclide therapy Techniques related to nuclear physics in medicine Medical applications of radiobiology and radiation protection
- 3 May 2017
- Published by Bioscientifica in Endocrine Abstracts
The role of 99mTc-sestamibi in amiodarone-induced thyrotoxicosis - Case report
Introduction: Amiodarone is an antiarrhythmic iodine-rich drug, known to induce thyroid dysfunction both due to its high iodine content and through amiodarone-induced thyrotoxicosis (AIT), being this latter process classified into three different types. Type 1 is associated with increased thyroid hormone synthesis; type 2 is a destructive process with thyroid hormone release and type 3 is thought to be a mixture of the former two. Since treatment options are different, there has been a growing need for a diagnostic method that could accurately distinguish these types and therefore allow targeted therapy. 99mTc-sestamibi scintigraphy has been gaining a specific role in this matter: with recognized increased uptake by epithelial cells that show high mitochondrial concentration, it allows the physician to visually differentiate between necrotic or destroyed tissue (which shows absent or very low uptake of the radiopharmaceutical) from hypermetabolic cells (with increased uptake). Case report: A 72-year-old male with atrial fibrillation treated with amiodarone for 10 years was sent to our Endocrinology outpatient clinic for new-onset asymptomatic subclinical hyperthyroidism (FT3 2.56 pg/ml (2.00 4.40); TT3 85 ng/dl (80–200); FT4 1.59 ng/dl (0.93–1.70); TT4 10.0 (5.1–14.1); TSH 0.03 mU/l (0.27–4.20)). He had a history of euthyroid benign nodular disease. We admitted AIT type 2, but considering the mild thyroid dysfunction, we chose to pursue further evaluation with 99mTc sestamibi scintigraphy, in order to initiate targeted therapy. Scintigraphic images showed initial uptake by the thyroid gland with rapid washout, a pattern described in literature as corresponding to AIT type 3. The patient’s thyroid hormones normalized before starting any medication and he is currently on follow-up. Conclusion: This case report is illustrative of the possible role of 99mTc sestamibi scintigraphy in diagnosis and management of thyroid disfunction induced by amiodarone. However, more expertise is further needed.
- 3 May 2017
- Published by Bioscientifica in Endocrine Abstracts
The role of 99mTc-sestamibi in amiodarone-induced thyrotoxicosis - Case report
Introduction: Amiodarone is an antiarrhythmic iodine-rich drug, known to induce thyroid dysfunction both due to its high iodine content and through amiodarone-induced thyrotoxicosis (AIT), being this latter process classified into three different types. Type 1 is associated with increased thyroid hormone synthesis; type 2 is a destructive process with thyroid hormone release and type 3 is thought to be a mixture of the former two. Since treatment options are different, there has been a growing need for a diagnostic method that could accurately distinguish these types and therefore allow targeted therapy. 99mTc-sestamibi scintigraphy has been gaining a specific role in this matter: with recognized increased uptake by epithelial cells that show high mitochondrial concentration, it allows the physician to visually differentiate between necrotic or destroyed tissue (which shows absent or very low uptake of the radiopharmaceutical) from hypermetabolic cells (with increased uptake). Case report: A 72-year-old male with atrial fibrillation treated with amiodarone for 10 years was sent to our Endocrinology outpatient clinic for new-onset asymptomatic subclinical hyperthyroidism (FT3 2.56 pg/ml (2.00 4.40); TT3 85 ng/dl (80–200); FT4 1.59 ng/dl (0.93–1.70); TT4 10.0 (5.1–14.1); TSH 0.03 mU/l (0.27–4.20)). He had a history of euthyroid benign nodular disease. We admitted AIT type 2, but considering the mild thyroid dysfunction, we chose to pursue further evaluation with 99mTc sestamibi scintigraphy, in order to initiate targeted therapy. Scintigraphic images showed initial uptake by the thyroid gland with rapid washout, a pattern described in literature as corresponding to AIT type 3. The patient’s thyroid hormones normalized before starting any medication and he is currently on follow-up. Conclusion: This case report is illustrative of the possible role of 99mTc sestamibi scintigraphy in diagnosis and management of thyroid disfunction induced by amiodarone. However, more expertise is further needed.
- Open Access
- 30 January 2016
- Published by Taylor & Francis in Revista Portuguesa de Pneumologia
- Vol. 22 (1) , 27-33
Pulmonary ventilation/perfusion single photon emission tomography – Initial experience of a Nuclear Medicine Department
Lung ventilation/perfusion scintigraphy with planar images (V/QS-planar) is very useful for the diagnosis and follow-up of pulmonary thromboembolism (PTE). Acquiring tomographic images (V/QS-SPECT) is a recent development with potential to increase the technique's accuracy. The purpose of this work is to evaluate the added benefits of V/QS-SPECT studies as opposed to traditional planar imaging. We prospectively revised 53 V/QS-planar and V/QS-SPECT exams, performed according to the European Association of Nuclear Medicine guidelines. We evaluated the exams independently, by consensus of two Nuclear Medicine physicians. For both methods, we gave each lung a score expressing the dimension and extension of perfusion defects with normal ventilation. For each lung, we compared the scores with the paired Wilcoxon test, estimating the 95% confidence interval (95 CI) for the respective difference. We performed V/QS-SPECT exams without technical difficulties. The paired Wilcoxon test estimated the score difference to be -0.75 (95 CI of -1.0 to -0.5; p-value=9.6 × 10(-7)), expressing a statistically significant difference of about 1 subsegmental defect between both methods, with V/QS-SPECT detecting more defects. The results demonstrate that V/QS-SPECT identifies a slightly larger number of perfusion defects than V/QS-planar, suggesting a higher sensitivity of this technique. However, more studies are necessary to evaluate the clinical meaning of this fact. V/QS-SPECT demonstrates a higher capability to identify perfusion defects. This method looks promising, allowing for a greater role of this exam in pulmonary thromboembolism diagnosis and follow-up.
- 30 January 2016
- Published by Taylor & Francis in Revista Portuguesa de Pneumologia
- Vol. 22 (1) , 27-33
Open AccessPulmonary ventilation/perfusion single photon emission tomography – Initial experience of a Nuclear Medicine Department
Lung ventilation/perfusion scintigraphy with planar images (V/QS-planar) is very useful for the diagnosis and follow-up of pulmonary thromboembolism (PTE). Acquiring tomographic images (V/QS-SPECT) is a recent development with potential to increase the technique's accuracy. The purpose of this work is to evaluate the added benefits of V/QS-SPECT studies as opposed to traditional planar imaging. We prospectively revised 53 V/QS-planar and V/QS-SPECT exams, performed according to the European Association of Nuclear Medicine guidelines. We evaluated the exams independently, by consensus of two Nuclear Medicine physicians. For both methods, we gave each lung a score expressing the dimension and extension of perfusion defects with normal ventilation. For each lung, we compared the scores with the paired Wilcoxon test, estimating the 95% confidence interval (95 CI) for the respective difference. We performed V/QS-SPECT exams without technical difficulties. The paired Wilcoxon test estimated the score difference to be -0.75 (95 CI of -1.0 to -0.5; p-value=9.6 × 10(-7)), expressing a statistically significant difference of about 1 subsegmental defect between both methods, with V/QS-SPECT detecting more defects. The results demonstrate that V/QS-SPECT identifies a slightly larger number of perfusion defects than V/QS-planar, suggesting a higher sensitivity of this technique. However, more studies are necessary to evaluate the clinical meaning of this fact. V/QS-SPECT demonstrates a higher capability to identify perfusion defects. This method looks promising, allowing for a greater role of this exam in pulmonary thromboembolism diagnosis and follow-up.
- 3 January 2015
- Published by Elsevier in International Journal of Cardiology
- Vol. 182, 381-383
Takotsubo cardiomyopathy, beyond ventriculography and classical bidimensional echocardiography
- 3 January 2015
- Published by Elsevier in International Journal of Cardiology
- Vol. 182, 381-383
Takotsubo cardiomyopathy, beyond ventriculography and classical bidimensional echocardiography
- 17 April 2014
- Published by Bioscientifica in Endocrine Abstracts
Prevalence and risk of malignancy of thyroid incidentalomas discovered by 18F-fluorodeoxyglucose positron emission tomography
The use of 18F-fluorodeoxyglucose positron emission tomography (18F-FDG–PET) has increased the detection of thyroid incidentalomas (TI). These are associated with a risk of malignancy between 25 and 50%. Some studies show an association between SUVmax uptake and malignancy. The objective of this study was to determine the prevalence of malignancy on 18F-FDG–PET positive thyroid nodules and to evaluate the relationship between SUVmax uptake and malignancy in a population of patients followed in a central hospital. We evaluated retrospectively all 18F-FDG–PET exams performed between 2008 and 2013. The inclusion criterion was focal thyroid uptake in patients studied for non-thyroid purposes. From the 1810 18F-FDG–PET exams (1384 patients), 3.2% (43) fulfilled the inclusion criteria, 60.5% were females (28), mean age was 68 years. Thyroid ultrasound was done in 39.5% (17) with an average nodule size of 20.5 mm. FNAC was performed in 37.2% (16) with 50% (8) benign, 31% (5) non-diagnostic, 6.5% (1) suspicious for papillary carcinoma and 12.5% (2) papillary carcinoma. Surgery was performed in the latter two categories, with a histological classification of papillary carcinoma in all three procedures (one with distant metastasis). The median SUVmax was five for the benign cases and 7.95 for the malignant ones (P=0.38). Focal 18F-FDG–PET thyroid uptake had a prevalence of 3.2%. The prevalence of malignancy was 19% on 18F-FDG–PET positive exams. Only 37.2% were evaluated by FNAC. Two possible explanations are the end of life status of these patients but also the lack of knowledge, on non-endocrine services, regarding the risk of malignancy of TI patients. A trend towards a higher risk of malignancy with higher SUVmax was found although it was not statistically significant. The limitations of the current work reflect an undervaluation of patients at risk and the rather high number of non-diagnostic FNAC.
- 17 April 2014
- Published by Bioscientifica in Endocrine Abstracts
Prevalence and risk of malignancy of thyroid incidentalomas discovered by 18F-fluorodeoxyglucose positron emission tomography
The use of 18F-fluorodeoxyglucose positron emission tomography (18F-FDG–PET) has increased the detection of thyroid incidentalomas (TI). These are associated with a risk of malignancy between 25 and 50%. Some studies show an association between SUVmax uptake and malignancy. The objective of this study was to determine the prevalence of malignancy on 18F-FDG–PET positive thyroid nodules and to evaluate the relationship between SUVmax uptake and malignancy in a population of patients followed in a central hospital. We evaluated retrospectively all 18F-FDG–PET exams performed between 2008 and 2013. The inclusion criterion was focal thyroid uptake in patients studied for non-thyroid purposes. From the 1810 18F-FDG–PET exams (1384 patients), 3.2% (43) fulfilled the inclusion criteria, 60.5% were females (28), mean age was 68 years. Thyroid ultrasound was done in 39.5% (17) with an average nodule size of 20.5 mm. FNAC was performed in 37.2% (16) with 50% (8) benign, 31% (5) non-diagnostic, 6.5% (1) suspicious for papillary carcinoma and 12.5% (2) papillary carcinoma. Surgery was performed in the latter two categories, with a histological classification of papillary carcinoma in all three procedures (one with distant metastasis). The median SUVmax was five for the benign cases and 7.95 for the malignant ones (P=0.38). Focal 18F-FDG–PET thyroid uptake had a prevalence of 3.2%. The prevalence of malignancy was 19% on 18F-FDG–PET positive exams. Only 37.2% were evaluated by FNAC. Two possible explanations are the end of life status of these patients but also the lack of knowledge, on non-endocrine services, regarding the risk of malignancy of TI patients. A trend towards a higher risk of malignancy with higher SUVmax was found although it was not statistically significant. The limitations of the current work reflect an undervaluation of patients at risk and the rather high number of non-diagnostic FNAC.
- 25 March 2014
- Published by Georg Thieme Verlag KG in Klinische Padiatrie
- Vol. 226 (04) , 225-232
Renal Radionuclide Imaging, an Evergreen Forty Years Old
Urinary tract congenital abnormalities (UCA) and febrile infections (UTI) are, respectively, 2 of the commonest congenital and acquired health problems in childhood. In both, radionuclide imaging still represent a cornerstone of diagnostic imaging, although the involved techniques are more or less the same from the early ’80 s. During the last 2 decades, published papers focused on a deep revision about the optimal use and usefulness of such imaging tools in affected children, with the aim of reducing invasiveness, radiation burden and costs without losing efficacy. This approach leads to different results. In UCA, no consensus for a diagnostic algorithm was up to now reached, whilst, about febrile UTIs, guidelines were published in 2007 by the UK’s National Institute for Clinical Excellence (NICE) and by the European Society of Paediatric Radiology (ESPR), in 2011 by the American Academy of Paediatrics (AAP), and in 2012 by the Italian Society of Paediatric Nephrology (SINP). Nevertheless, new data continuously arise and the scientific debate always revives. Every imaging tool now available has its own strengths and weaknesses, and so all published guidelines. All this body of knowledge must be critically analysed for obtaining a complete, up-to-date and flexible overview about these “always hot” topics. Kongenitale Anomalien und fieberhafte Infektionen der Niere und ableitenden Harnwege gehören zu den häufigsten Erkrankungen im Kindesalter. Die Radionuklid-Bildgebung ist seit den frühen 80iger Jahren bis heute ein Eckpfeiler der Diagnostik dieser Erkrankungen. In den letzten 2 Jahrzehnten gab es tiefgreifende Diskussionen über den optimalen Einsatz und den Wert dieser Methoden insbesondere im Hinblick auf eine Verringerung der Invasivität, der Strahlenexposition und der Kosten ohne dabei die Effizienz zu gefährden. Dieser Prozess hat für die Diagnostik der Harntraktanomalien bis heute zu keinem Konsens geführt. Dagegen wurden für die nuklearmedizinische Diagnostik der fieberhaften Infekte der Niere und Harnwege neue Leitlinien 2007 durch das Nationale Institut für Klinische Exzellenz (NICE) in Großbritannien und durch die Europäische Gesellschaft für Pädiatrische Radiologie (ESPR), sowie 2011 durch die Amerikanische Akademie für Pädiatrie (AAP) und 2012 durch die Italienische Gesellschaft für Pädiatrische Nephrologie (SINP) veröffentlicht. Die kontinuierlich aktualisierte Datenlage führt jedoch auch in diesem Gebiet zu einem ständigen Wiederaufleben der wissenschaftlichen Debatten. Jedes derzeit verfügbare bildgebende Verfahren hat – wie auch jede publizierte Leitlinie – ihre eigenen Stärken und Schwächen. Dieses Wissen muss kritisch analysiert werden, um einen komplexen, zeitgemäßen und flexiblen Überblick auf diesem vieldiskutierten Gebiet zu erhalten.
- 25 March 2014
- Published by Georg Thieme Verlag KG in Klinische Padiatrie
- Vol. 226 (04) , 225-232
Renal Radionuclide Imaging, an Evergreen Forty Years Old
Urinary tract congenital abnormalities (UCA) and febrile infections (UTI) are, respectively, 2 of the commonest congenital and acquired health problems in childhood. In both, radionuclide imaging still represent a cornerstone of diagnostic imaging, although the involved techniques are more or less the same from the early ’80 s. During the last 2 decades, published papers focused on a deep revision about the optimal use and usefulness of such imaging tools in affected children, with the aim of reducing invasiveness, radiation burden and costs without losing efficacy. This approach leads to different results. In UCA, no consensus for a diagnostic algorithm was up to now reached, whilst, about febrile UTIs, guidelines were published in 2007 by the UK’s National Institute for Clinical Excellence (NICE) and by the European Society of Paediatric Radiology (ESPR), in 2011 by the American Academy of Paediatrics (AAP), and in 2012 by the Italian Society of Paediatric Nephrology (SINP). Nevertheless, new data continuously arise and the scientific debate always revives. Every imaging tool now available has its own strengths and weaknesses, and so all published guidelines. All this body of knowledge must be critically analysed for obtaining a complete, up-to-date and flexible overview about these “always hot” topics. Kongenitale Anomalien und fieberhafte Infektionen der Niere und ableitenden Harnwege gehören zu den häufigsten Erkrankungen im Kindesalter. Die Radionuklid-Bildgebung ist seit den frühen 80iger Jahren bis heute ein Eckpfeiler der Diagnostik dieser Erkrankungen. In den letzten 2 Jahrzehnten gab es tiefgreifende Diskussionen über den optimalen Einsatz und den Wert dieser Methoden insbesondere im Hinblick auf eine Verringerung der Invasivität, der Strahlenexposition und der Kosten ohne dabei die Effizienz zu gefährden. Dieser Prozess hat für die Diagnostik der Harntraktanomalien bis heute zu keinem Konsens geführt. Dagegen wurden für die nuklearmedizinische Diagnostik der fieberhaften Infekte der Niere und Harnwege neue Leitlinien 2007 durch das Nationale Institut für Klinische Exzellenz (NICE) in Großbritannien und durch die Europäische Gesellschaft für Pädiatrische Radiologie (ESPR), sowie 2011 durch die Amerikanische Akademie für Pädiatrie (AAP) und 2012 durch die Italienische Gesellschaft für Pädiatrische Nephrologie (SINP) veröffentlicht. Die kontinuierlich aktualisierte Datenlage führt jedoch auch in diesem Gebiet zu einem ständigen Wiederaufleben der wissenschaftlichen Debatten. Jedes derzeit verfügbare bildgebende Verfahren hat – wie auch jede publizierte Leitlinie – ihre eigenen Stärken und Schwächen. Dieses Wissen muss kritisch analysiert werden, um einen komplexen, zeitgemäßen und flexiblen Überblick auf diesem vieldiskutierten Gebiet zu erhalten.
- 8 October 2012
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 154 (4) , 446-458
Estimation of the collective dose in the Portuguese population due to medical procedures in 2010
In a wide range of medical fields, technological advancements have led to an increase in the average collective dose in national populations worldwide. Periodic estimations of the average collective population dose due to medical exposure is, therefore of utmost importance, and is now mandatory in countries within the European Union (article 12 of EURATOM directive 97/43). Presented in this work is a report on the estimation of the collective dose in the Portuguese population due to nuclear medicine diagnostic procedures and the Top 20 diagnostic radiology examinations, which represent the 20 exams that contribute the most to the total collective dose in diagnostic radiology and interventional procedures in Europe. This work involved the collaboration of a multidisciplinary taskforce comprising representatives of all major Portuguese stakeholders (universities, research institutions, public and private healthcare providers, administrative services of the National Healthcare System, scientific and professional associations and private service providers). This allowed us to gather a comprehensive amount of data necessary for a robust estimation of the collective effective dose to the Portuguese population. The methodology used for data collection and dose estimation was based on European Commission recommendations, as this work was performed in the framework of the European wide Dose Datamed II project. This is the first study estimating the collective dose for the population in Portugal, considering such a wide national coverage and range of procedures and consisting of important baseline reference data. The taskforce intends to continue developing periodic collective dose estimations in the future. The estimated annual average effective dose for the Portuguese population was of 0.080±0.017 mSv caput−1 for nuclear medicine exams and of 0.96±0.68 mSv caput−1 for the Top 20 diagnostic radiology exams.
- 8 October 2012
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 154 (4) , 446-458
Estimation of the collective dose in the Portuguese population due to medical procedures in 2010
In a wide range of medical fields, technological advancements have led to an increase in the average collective dose in national populations worldwide. Periodic estimations of the average collective population dose due to medical exposure is, therefore of utmost importance, and is now mandatory in countries within the European Union (article 12 of EURATOM directive 97/43). Presented in this work is a report on the estimation of the collective dose in the Portuguese population due to nuclear medicine diagnostic procedures and the Top 20 diagnostic radiology examinations, which represent the 20 exams that contribute the most to the total collective dose in diagnostic radiology and interventional procedures in Europe. This work involved the collaboration of a multidisciplinary taskforce comprising representatives of all major Portuguese stakeholders (universities, research institutions, public and private healthcare providers, administrative services of the National Healthcare System, scientific and professional associations and private service providers). This allowed us to gather a comprehensive amount of data necessary for a robust estimation of the collective effective dose to the Portuguese population. The methodology used for data collection and dose estimation was based on European Commission recommendations, as this work was performed in the framework of the European wide Dose Datamed II project. This is the first study estimating the collective dose for the population in Portugal, considering such a wide national coverage and range of procedures and consisting of important baseline reference data. The taskforce intends to continue developing periodic collective dose estimations in the future. The estimated annual average effective dose for the Portuguese population was of 0.080±0.017 mSv caput−1 for nuclear medicine exams and of 0.96±0.68 mSv caput−1 for the Top 20 diagnostic radiology exams.
- 11 September 2012
- Published by Elsevier in Revista Española de Medicina Nuclear e Imagen Molecular
- Vol. 32 (2) , 98-101
Lung ventilation/perfusion scintigraphy in pulmonary capillary hemangiomatosis: A pattern to consider
- 11 September 2012
- Published by Elsevier in Revista Española de Medicina Nuclear e Imagen Molecular
- Vol. 32 (2) , 98-101
Lung ventilation/perfusion scintigraphy in pulmonary capillary hemangiomatosis: A pattern to consider
- 26 July 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 149 (4) , 438-443
Study of nuclear medicine practices in Portugal from an internal dosimetry perspective
Nuclear medicine practices involve the handling of a wide range of pharmaceuticals labelled with different radionuclides, for diagnostic and therapeutic purposes. This work intends to evaluate the potential risks of internal contamination of nuclear medicine staff in several Portuguese nuclear medicine services and to conclude about the requirement of a routine internal monitoring. A methodology proposed by the International Atomic Energy Agency (IAEA), providing a set of criteria to determine the need, or not, for an internal monitoring programme, was applied. The evaluation of the risk of internal contaminations in a given set of working conditions is based on the type and amount of radionuclides being handled, as well as the safety conditions with which they are manipulated. The application of the IAEA criteria showed that 73.1 % of all the workers included in this study should be integrated in a routine monitoring programme for internal contaminations; more specifically, 100 % of workers performing radioimmunoassay techniques should be monitored. This study suggests that a routine monitoring programme for internal exposures should be implemented in Portugal for most nuclear medicine workers.
- 26 July 2011
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 149 (4) , 438-443
Study of nuclear medicine practices in Portugal from an internal dosimetry perspective
Nuclear medicine practices involve the handling of a wide range of pharmaceuticals labelled with different radionuclides, for diagnostic and therapeutic purposes. This work intends to evaluate the potential risks of internal contamination of nuclear medicine staff in several Portuguese nuclear medicine services and to conclude about the requirement of a routine internal monitoring. A methodology proposed by the International Atomic Energy Agency (IAEA), providing a set of criteria to determine the need, or not, for an internal monitoring programme, was applied. The evaluation of the risk of internal contaminations in a given set of working conditions is based on the type and amount of radionuclides being handled, as well as the safety conditions with which they are manipulated. The application of the IAEA criteria showed that 73.1 % of all the workers included in this study should be integrated in a routine monitoring programme for internal contaminations; more specifically, 100 % of workers performing radioimmunoassay techniques should be monitored. This study suggests that a routine monitoring programme for internal exposures should be implemented in Portugal for most nuclear medicine workers.