PPPetro Plieshkov

Petro Plieshkov

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Petro Plieshkov has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Determining weight coefficients in the control system for a symmetry-compensating device using a fuzzy logic apparatus

    by Petro Plieshkov, Vasyl Zinzura, Kateryna Petrova, Valentyn Soldatenko, Andrii Nekrasov

    This study investigates processes of automatic control over parameters of the distribution network mode at a voltage of 6–10 kV with a sharply changing asymmetric load. The task addressed relates to the compromised efficiency of existing systems for automatic control over symmetry-compensating devices, which are based on multi-criteria optimization methods with unchanged weight coefficients. Such systems continue to give maximum priority to reducing the steady-state voltage deviation even if it meets regulatory requirements. This leads to incomplete utilization of regulating reserve of the symmetry-compensating device. The system of automatic control over the symmetry-compensating device has been improved by integrating a fuzzy controller into its structure. This controller changes the values of weight coefficients in the objective function depending on the current values of the network mode parameters. The computer simulation has confirmed the effectiveness of the designed system, which provided a reduction in the mathematical expectations of the reactive power factor M[tanφ] by 13.9% and the voltage unbalance factor M[k2U] by 8.5% compared to the baseline. The increase in the efficiency of the control system is explained by its ability to adaptively change the weight coefficients. Thus, if there is a margin for the steady-state voltage deviation, the fuzzy controller reduces the weight coefficient that meets this criterion, directing the regulating resource of the symmetrical-compensating device to increase the level of reactive power compensation and reduce the level of asymmetry. A feature of the designed control system is the use of the levels of approximation of the current values of the steady-state deviation and voltage asymmetry to their regulatory permissible limits as input variables in the fuzzy controller. The designed automatic control system could be used in distribution electrical networks with a voltage of 6–10 kV at a sharply changing asymmetrical load


  • Open Access

    Synthesis of a robust system for automatic control of energy-efficient lighting under conditions of parametric uncertainty

    by P.H. Plieshkov, V.V. Zinzura, K.H. Petrova, N.YU. Harasova, V.P. Soldatenko

    The article solves the current scientific and practical problem of ensuring the stability and energy efficiency of automatic industrial lighting systems. Under conditions of long-term operation, parametric degradation of the optical medium and temperature aging of LED components occur. This leads to a significant decrease in the quality of transient processes when using classical proportional-integral-differential regulators, the occurrence of overregulation and flickering of light harmful to the eyesight of workers. The purpose of this study is to develop an algorithm for robust control of the industrial LED lighting system based on the synthesis apparatus to ensure stable regulatory indicators of visual comfort under conditions of operational degradation of equipment and the action of uncontrolled external disturbances. To achieve the set goal, a mathematical synthesis apparatus was applied within the framework of an extended mixed sensitivity problem. A system of weighting filters was formed that provide the system with astaticity and robust resistance to high-frequency noise. Finding the suboptimal controller was carried out by solving a system of algebraic matrix Riccati equations in the state space. The results of computer simulation confirmed the significant advantage of the proposed method. It was established that under conditions of parametric degradation, the classical controller allows a significant level of overshoot, while the synthesized robust controller eliminates overshoot and stably maintains the regulatory level of illumination. The scientific novelty of the study lies in the justification and application of the robust synthesis method with direct penalty of the control effort directly for LED lighting systems, which makes sharp current surges in the drivers impossible. The practical significance of the results obtained lies in the possibility of implementing the algorithm in industrial microcontrollers to ensure high visual comfort, optimize energy consumption and extend the service life of the equipment. Further research in this direction should be focused on integrating the developed algorithm with fuzzy logic methods to create hybrid adaptive smart lighting control systems

  • Optimal Control of Active Power Generation Levels by Renewable Energy Plants

    by Petro Plieshkov, Valentyn Soldatenko, Vasyl Zinzura, Serhii Plieshkov

    Petro Plieshkov, Professor, Candidate of Technical Sciences, Head of the Department of Electrical Systems and Energy Management, Central Ukrainian National Technical University, Kropyvnytskyi, Ukraine, ORCID: https://orcid.org/0000-0003-2141-4811, e-mail: kafedra.etsem@gmail.com Valentyn Soldatenko, Associate Professor, Candidate of Technical Sciences, Associate Professor of the Department of Electrical Systems and Energy Management, Central Ukrainian National Technical University, Kropyvnytskyi, Ukraine, ORCID: https://orcid.org/0000-0002-7781-9343, e-mail: kirovograd41@gmail.com Vasyl Zinzura, Associate Professor, Candidate of Technical Sciences, Associate Professor of the Department of Electrical Systems and Energy Management, Central Ukrainian National Technical University, Kropyvnytskyi, Ukraine, ORCID: https://orcid.org/0000-0001-6357-064X, e-mail: vasiliyzinzura@gmail.com Oleksandr Sirikov, Associate Professor, Candidate of Technical Sciences, Associate Professor of the Department of Electrical Systems and Energy Management, Central Ukrainian National Technical University, Kropyvnytskyi, Ukraine, ORCID: https://orcid.org/0000-0002-7058-2697, e-mail: asirikov@i.ua Serhii Plieshkov, Associate Professor, Candidate of Technical Sciences, Associate Professor of the Department of Automation of Production Processes, Central Ukrainian National Technical University, Kropyvnytskyi, Ukraine, ORCID: https://orcid.org/0000-0002-3120-5397, e-mail: sergploff@gmail.com. The purpose of this article is to develop an effective approach to automated control of the level of active power generation in systems based on renewable energy sources in order to ensure maximum electricity generation while complying with the regulatory permissible voltage deviation limits at the points of connection of electricity consumers to the distribution grid. The article analyzes the problems that arise when generating electricity from renewable sources in the conditions of distribution grids - in particular, exceeding the permissible voltage level at the points of connection and reducing the economic efficiency of generation when using typical automatic control systems. It is proposed to improve the system for automatic control of the level of active power generation by installations with renewable energy sources by formalizing the control process as a multi-criteria optimization problem. The main criteria are profit from the sale of electricity and economic losses from voltage quality disturbances. The problem is solved by the method of approximation to the utopian point using the Chebyshev metric and numerical methods of discrete optimization. For this purpose, a step-by-step algorithm was developed, which involves discretization of the area of permissible generation values, calculation of the Pareto-optimal set, determination of the utopian point and minimization of the distance to it. In order to assess the effectiveness of the proposed approach, a computer model of the automatic control system was built, which is based on the specified algorithm. The model was tested in a simulation environment, where it was compared with a traditional control system that provides a strict limitation of the voltage deviation. The simulation results showed that the proposed approach provides an increase in the volume of electricity supply to the network by 8.1% compared to the base model. At the same time, the level of the steady-state voltage deviation at the connection point meets the regulatory requirements for the quality of electricity (integral probability - 95%). Thus, the improved automatic control system allows achieving both technical and economic optimality of the functioning of renewable energy sources in the power system

  • Determination of the optimal point of connection of the solar power plant to the electrical network by computer simulation

    by Petro Plieshkov, Central Ukrainian National Technical University, Vasyl Zinzura, Serhii Plieshkov, Valentyn Soldatenko

    Petro Plieshkov, Professor, Doctor in Technics (Doctor of Technic Sciences), Central Ukrainian National Technical University, Kropivnitskiy, Ukraine, e-mail: plieshkov@gmail.com, ORCID ID: 0000-0003-2141-4811 Vasyl Zinzura, Associate Professor, PhD in Technics (Candidate of Technics Sciences), Central Ukrainian National Technical University, Kropivnitskiy, Ukraine, e-mail: vasiliyzinzura@gmail.com, ORCID ID: 0000-0001-6357-064X Serhii Plieshkov, Associate Professor, PhD in Technics (Candidate of Technics Sciences), Central Ukrainian National Technical University, Kropivnitskiy, Ukraine, e-mail: sergploff@gmail.com, ORCID ID: 0000-0002-3120-5397 Valentyn Soldatenko, Associate Professor, PhD in Technics (Candidate of Technics Sciences), Central Ukrainian National Technical University, Kropivnitskiy, Ukraine, e-mail: kirovograd41@gmail.com, ORCID ID: 0000-0002-7781-9343 Abstract The purpose of this study is to minimize the negative impact of the solar power plant on the value of the steady voltage deviation and the level of electricity losses by determining the optimal place for its connection to the distribution network. Currently, quite a large number of methods of optimal placement of renewable sources of electricity in electrical networks have been developed. However, most of them either do not fully take into account the multifunctional influence of renewable energy sources on the parameters of the electric network regime, or are quite difficult to use. In order to solve the problem of optimal placement of renewable sources of electricity in electric networks, it is proposed to use the method of computer simulation modeling. The essence of this method is to determine the optimal place for connecting a renewable energy source to the electrical network based on the analysis of the results of computer simulation modeling of network mode parameters. This approach is the most acceptable in the case of connecting a solar power plant of average power to the electrical network of an industrial enterprise. The developed computer simulation model of a distribution electric network with a solar power plant allows for the research of network mode parameters, including the determination of the level of active power loss in network elements and the level of steady voltage deviation. The specified computer simulation models of the distribution electric network with a solar power plant made it possible to determine the optimal place for connecting the solar power plant based on the values of power losses in the elements of the electric network at the level of the established voltage deviation. The results of computer modeling of an electrical network with a solar power plant confirmed the need to take into account not only the values of the established voltage deviation, but also the amount of electrical energy losses in the network elements in the process of choosing a place to install a solar power plant. The results of the research can be used in solving the problems of determining the place of connection of a medium-power solar power plant to the electrical network of an industrial enterprise. The purpose of this study is to minimize the negative impact of the solar power plant on the value of the steady voltage deviation and the level of electricity losses by determining the optimal place for its connection to the distribution network. Currently, quite a large number of methods of optimal placement of renewable sources of electricity in electrical networks have been developed. However, most of them either do not fully take into account the multifunctional influence of renewable energy sources on the parameters of the electric network regime, or are quite difficult to use. In order to solve the problem of optimal placement of renewable sources of electricity in electric networks, it is proposed to use the method of computer simulation modeling. The essence of this method is to determine the optimal place for connecting a renewable energy source to the electrical network based on the analysis of the results of computer simulation modeling of network mode parameters. This approach is the most acceptable in the case of connecting a solar power plant of average power to the electrical network of an industrial enterprise. The developed computer simulation model of a distribution electric network with a solar power plant allows for the research of network mode parameters, including the determination of the level of active power loss in network elements and the level of steady voltage deviation. The specified computer simulation models of the distribution electric network with a solar power plant made it possible to determine the optimal place for connecting the solar power plant based on the values of power losses in the elements of the electric network at the level of the established voltage deviation. The results of computer modeling of an electrical network with a solar power plant confirmed the need to take into account not only the values of the established voltage deviation, but also the amount of electrical energy losses in the network elements in the process of choosing a place to install a solar power plant. The results of the research can be used in solving the problems of determining the place of connection of a medium-power solar power plant to the electrical network of an industrial enterprise. Keywords solar power plant, computer modeling, distribution network Full Text: PDF References 1. Aderibigbe M., Adoghe A., Agbetuyi F., Airoboman A. (2021). A Review on Optimal Placement of Distributed Generators for Reliability Improvement on Distribution Network. IEEE PES/IAS PowerAfrica, Nairobi, Kenya, pp. 1-5. DOI: 10.1109/PowerAfrica52236.2021.9543266 [in English]. 2. Khasanov, M., Kamel, S., Jurado, F., Kurbanov, A., and Jalilov, U. (2023) Photovoltaic-based Distributed Generation Allocation in Distribution Network for Energy Loss Minimization. E3S Web of Conferences, Vol. 434. DOI:10.1051/e3sconf/202343401015 [in English]. 3. Kansal, S., Kumar, V. & Tyagi B. (2016). Hybrid approach for optimal placement of multiple DGs of multiple types in distribution networks. International Journal of Electrical Power & Energy Systems, Vol. 75, P. 226-235 DOI: https://doi.org/10.1016/j.ijepes.2015.09.002 [in English]. 4. Chen, M., Ma, S., Soltani, Z., Ayyanar, R., Vittal, V. & Khorsand M. (2023). Optimal Placement of PV Smart Inverters With Volt-VAr Control in Electric Distribution Systems. IEEE Systems Journal,. Vol. 17, No.3, P. 3436-3446. DOI: 10.1109/JSYST.2023.3256121 [in English]. 5. Salam I.U., Yousif M., Numan M., Zeb K., Billah M. (2023) Optimizing Distributed Generation Placement and Sizing in Distribution Systems: A Multi-Objective Analysis of Power Losses, Reliability, and Operational Constraints. Energies, vol.16 (16), 5907; DOI: 10.3390/en16165907 [in English]. 6. Plieshkov, P.H., Haras'ova, N.Yu. & Soldatenko, V.P. (2018). Optymal'ne keruvannia rezhymom roboty kombinovanoi elektroenerhetychnoi systemy z vidnovliuvanymy dzherelamy enerhii [Optimal Control of the Work of the Hybrid Electric Energy System With Renevable Sources of Energy]. Visnyk Natsional'noho tekhnichnoho universytetu «KhPI». Seriia: Problemy udoskonaliuvannia elektrychnykh mashyn i aparativ. Teoriia i praktyka - Bulletin of the National Technical University "KhPI". Collection of scientific works. Series: Problems of Improvement of Electric Machines and Apparatus, 32(1308), 64–70. DOI: 10.20998/2079-3944.2018.32 [in Ukrainian]. 7. Plieshkov, P., Soldatenko, V., Zinzura, V. & Plieshkov S. (2020). Determining weight coefficients for an optimal system of control over electric energy generation in a combined electric power system. Eastern-European Journal of Enterprise Technologies, Vol. 103, No 1/2020, P. 77 – 82. DOI: https://doi.org/10.15587/1729-4061.2020.193362 [in English]. 8. Power systems analysis software DIgSILENT PowerFactory. Retrieved from: http://www.digsilent.de/Software/DIgSILENT_PowerFactory/PFv14_Software.pdf. 9. Akintunde, A. et al. (2021). Power Quality Considerations for Distributed Generation Integration in the Nigerian Distribution Network Using NEPLAN Software. International Journal of Energy Economics and Policy, No. 11, P. 331-342. DOI:10.32479/ijeep.11145 [in English]. 10. Perelmuter, V. (2020). Advanced Simulation of Alternative Energy (1st ed.). CRC Press. 314 p. DOI: https://doi.org/10.1201/9780429324055 [in English]. Citations 1. Aderibigbe M., Adoghe A., Agbetuyi F., Airoboman A. (2021). A Review on Optimal Placement of Distributed Generators for Reliability Improvement on Distribution Network. IEEE PES/IAS PowerAfrica, Nairobi, Kenya, pp. 1-5. DOI: 10.1109/PowerAfrica52236.2021.9543266. 2. Khasanov, M., Kamel, S., Jurado, F., Kurbanov, A., and Jalilov, U. (2023) Photovoltaic-based Distributed Generation Allocation in Distribution Network for Energy Loss Minimization. E3S Web of Conferences. Vol. 434. DOI:10.1051/e3sconf/202343401015 3. Kansal S., Kumar V., Tyagi B. Hybrid approach for optimal placement of multiple DGs of multiple types in distribution networks. International Journal of Electrical Power & Energy Systems. 2016. Vol. 75. Р. 226-235 DOI: https://doi.org/10.1016/j.ijepes.2015.09.002. 4. Chen M., Ma S., Soltani Z., Ayyanar R., Vittal V., Khorsand M. Optimal Placement of PV Smart Inverters With Volt-VAr Control in Electric Distribution Systems. IEEE Systems Journal. 2023. Vol. 17, No. 3. Р. 3436-3446. DOI: 10.1109/JSYST.2023.3256121. 5. Salam I.U., Yousif M., Numan M., Zeb K., Billah M. Optimizing Distributed Generation Placement and Sizing in Distribution Systems: A Multi-Objective Analysis of Power Losses, Reliability, and Operational Constraints. Energies. 2023. Vol.16 (16). Р. 5907. DOI: 10.3390/en16165907 6. Плєшков П.Г., Гарасьова Н.Ю., Солдатенко В.П. Оптимальне керування режимом роботи комбінованої електроенергетичної системи з відновлюваними джерелами енергії. Вісник Національного технічного університету «ХПІ». Серія: Проблеми удосконалювання електричних машин і апаратів. Теорія і практика. 2018. №32 (1308). С. 64-70. 7. Plieshkov P., Soldatenko V., Zinzura V., Plieshkov S. Determining weight coefficients for an optimal system of control over electric energy generation in a combined electric power system. Eastern-European Journal of Enterprise Technologies. 2020. Vol. 103, No 1/2020. P. 77 – 82. DOI: https://doi.org/10.15587/1729-4061.2020.193362. 8. Power systems analysis software DIgSILENT PowerFactory. – Режим доступу: http://www.digsilent.de/Software/DIgSILENT_PowerFactory/PFv14_Software.pdf. 9. Akintunde A., Owoicho O., Shomefun T., Olowoleni O., Ignatius O., Abdulkareem A. Power Quality Considerations for Distributed Generation Integration in the Nigerian Distribution Network Using NEPLAN Software. International Journal of Energy Economics and Policy. 2021. No. 11. Р. 331-342. DOI:10.32479/ijeep.11145 10. Perelmuter, V. Advanced Simulation of Alternative Energy (1st ed.). CRC Press. 2020. 314 p. DOI: https://doi.org/10.1201/9780429324055 Copyright (c) 2023 Petro Plieshkov, Vasyl Zinzura, Serhii Plieshkov, Valentyn Soldatenko


  • Optimal Control of the Modes of Distribution Electrical Networks With Solar Power Plants Under Unbalanced Load

    by Central Ukrainian National Technical University, Artem Sachenko, Sergii Plieshkov, Petro Plieshkov, Vasyl Zinzura

    The article is devoted to improving the system of automatic control of modes of distribution electric networks containing solar power plants in order to achieve a simultaneous reduction of steady-state voltage deviations, voltage asymmetry at the terminals of consumers while maximizing the level of electricity generation by solar power plants. Ensuring normal permissible levels of electricity quality indicators in distribution networks is one of the most pressing issues that arise in the design and operation of modern distribution networks. Deterioration of the quality of electricity in electrical networks leads to the appearance of such negative phenomena, increase in additional losses in the elements of the electrical network, reduce the service life of electrical equipment, reduce the productivity of production equipment and others. The most significant negative impact on the functioning of the elements of electrical distribution networks, including electricity consumers, is observed with increasing levels of steady-state deviation and voltage asymmetry above the normative values. Modern solar inverters allow you to control the level of steady voltage deviation at the point of their connection to the mains. The design features of the construction of inverters of solar power plants allow them to change (within certain limits) not only the level of steady-state voltage deviation, but also to affect the level of voltage asymmetry and the parameters of the reactive power mode. In view of this, the task of improving automatic control systems for the distribution of electric networks with solar power plants, the implementation of which will take into account the multifunctional influence of solar inverters on the parameters of these networks is quite relevant. For the research, a fragment of a typical distribution electrical network with a nominal voltage of 10 kV was used, which contains a solar power plant that connects directly to the 10 kV busbars. The authors of the article set the problem of controlling the parameters of the mode of distribution electric network with solar power plants in the form of the problem of multicriteria optimization. An approach to solving this problem is also proposed, which is based on the method of solving problems of multicriteria optimization by approaching the utopian point in the space of criteria. Approximate calculations are carried out, which confirm the possibility of applying the proposed approach to the construction of systems for automatic control of the parameters of the mode of distribution electrical networks with solar power plants

  • Automatic control of electrical distribution network mode with the voltage unbalance

    by P.H. Plieshkov, V.V. Zinzura, S.P. Plieshkov

    Automatic control of electrical distribution network mode with the voltage unbalance


  • Problems of Determining the Efficiency and Ranking of Energy-saving Measures at the Objects of the Budget Sphere

    by Central Ukrainian National Technical University, Petro Pleshkov, Sergiy Serebrennikov, Central Ukrainian National Technical Universit, Kateryna Petrova, Ivan Savelenko, Oleksandr Sirikov