Hideyuki Hasebe
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Hideyuki Hasebe has a total of 130 co-authors. Here are the top co-authors by number of shared publications:
Yoshitaka Furuyashiki
15 shared publicationsKentaro Yoshida
Department of Cardiology, Institute of Medicine, University of Tsukuba, Tsukuba, Japan
8 shared publications- Kentaro Yoshida
Department of Cardiology Institute of Medicine, University of Tsukuba Tsukuba Japan
8 shared publications - Akihiko Nogami
Department of Cardiology Institute of Medicine, University of Tsukuba Tsukuba Japan
6 shared publications Masaki Ieda
Department of Cardiology, Institute of Medicine, University of Tsukuba
4 shared publicationsAkihiko Nogami
Department of Cardiology Institute of Medicine, University of Tsukuba Tsukuba Japan
3 shared publications
Latest Publications
- Open Access
- 31 March 2025
- Published by Elsevier in HeartRhythm Case Reports
- Vol. 11 (6) , 572-576
Detailed delineation and electrophysiological assessments of an atriofascicular pathway masking antegrade right bundle branch block
- 31 March 2025
- Published by Elsevier in HeartRhythm Case Reports
- Vol. 11 (6) , 572-576
Open AccessDetailed delineation and electrophysiological assessments of an atriofascicular pathway masking antegrade right bundle branch block
- Open Access
- 21 November 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 8 (12) , ytae604
Unidirectional reconnection of an inter-atrial epicardial connection with wide right atrial insertion site: a case report
Background: The epicardial connections (ECs) via intercaval fibres connecting the right-sided pulmonary veins (PVs) and right atrium (RA) can preclude isolation of the right-sided PVs. Such ECs occasionally have a unidirectional conduction property. Case summary: A 62-year-old man was referred to our institution for catheter ablation of paroxysmal atrial fibrillation (PAF). Circumferential antral PV isolation was performed via point-by-point radiofrequency (RF) applications. Thirty months after the ablation session, a recurrence of PAF was observed and a second procedure was performed. The right-sided PV was reconnected via an EC. Radiofrequency application at the RA insertion eliminated the EC. Thirty minutes thereafter, the right-sided PVs were reconnected. However, repetitive firings from the right-sided PVs did not conduct to the RA, indicating a unidirectional (RA to PV) reconnection of the EC, which was resolved by RF applications at the PV insertion. This time, the PV insertion of the EC was targeted and the unidirectional reconnection was successfully eliminated. The patient has remained free from any tachyarrhythmias for 3 years. Discussion: Although the mechanism of the unidirectional conduction property is unclear, source-sink mismatch and anisotropy are likely involved in the mechanism, as with accessory pathways. Electrophysiologists should be aware of the potential for unidirectional reconnection of ECs.
- 21 November 2024
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 8 (12) , ytae604
Open AccessUnidirectional reconnection of an inter-atrial epicardial connection with wide right atrial insertion site: a case report
Background: The epicardial connections (ECs) via intercaval fibres connecting the right-sided pulmonary veins (PVs) and right atrium (RA) can preclude isolation of the right-sided PVs. Such ECs occasionally have a unidirectional conduction property. Case summary: A 62-year-old man was referred to our institution for catheter ablation of paroxysmal atrial fibrillation (PAF). Circumferential antral PV isolation was performed via point-by-point radiofrequency (RF) applications. Thirty months after the ablation session, a recurrence of PAF was observed and a second procedure was performed. The right-sided PV was reconnected via an EC. Radiofrequency application at the RA insertion eliminated the EC. Thirty minutes thereafter, the right-sided PVs were reconnected. However, repetitive firings from the right-sided PVs did not conduct to the RA, indicating a unidirectional (RA to PV) reconnection of the EC, which was resolved by RF applications at the PV insertion. This time, the PV insertion of the EC was targeted and the unidirectional reconnection was successfully eliminated. The patient has remained free from any tachyarrhythmias for 3 years. Discussion: Although the mechanism of the unidirectional conduction property is unclear, source-sink mismatch and anisotropy are likely involved in the mechanism, as with accessory pathways. Electrophysiologists should be aware of the potential for unidirectional reconnection of ECs.
- Open Access
- 7 November 2024
- Published by Elsevier in Heart Rhythm O2
- Vol. 6 (1) , 103-107
Radiofrequency catheter ablation of persistent atrial fibrillation in a patient with cor triatriatum sinister
- 7 November 2024
- Published by Elsevier in Heart Rhythm O2
- Vol. 6 (1) , 103-107
Open AccessRadiofrequency catheter ablation of persistent atrial fibrillation in a patient with cor triatriatum sinister
- Open Access
- 10 October 2024
- Published by Elsevier in HeartRhythm Case Reports
- Vol. 11 (1) , 51-55
Cryoballoon ablation eliminated an epicardial conduction over the lateral mitral isthmus refractory to radiofrequency and chemical ablation: A case report
- 10 October 2024
- Published by Elsevier in HeartRhythm Case Reports
- Vol. 11 (1) , 51-55
Open AccessCryoballoon ablation eliminated an epicardial conduction over the lateral mitral isthmus refractory to radiofrequency and chemical ablation: A case report
- Open Access
- 5 October 2024
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 25 (1) , 37-38
Pivoting turn-around activation guided successful slow pathway ablation in the cavotricuspid isthmus
- 5 October 2024
- Published by Elsevier in Indian Pacing and Electrophysiology Journal
- Vol. 25 (1) , 37-38
Open AccessPivoting turn-around activation guided successful slow pathway ablation in the cavotricuspid isthmus
- 20 May 2024
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 35 (7) , 1461-1470
Vein of Marshall chemical ablation decreases atrial fibrillation drivers detected by CARTOFINDER
Introduction: This study sought to elucidate the impact of vein of Marshall (VOM) chemical ablation on atrial fibrillation (AF) drivers by investigating the changes in CARTOFINDER mappings before and after VOM chemical ablation in patients with persistent AF.Methods: This study included 23 consecutive patients undergoing catheter ablation for long‐persistent AF (>18 months). VOM chemical ablation was performed following pulmonary vein isolation. CARTOFINDER and AF cycle length (AFCL) maps were created in the left atrium (LA) before and after VOM chemical ablation. The LA was divided into 8 segments, and the number of focal activation points with 6 or more repetitions was counted in each segment.Results: The number of focal activation points was largest in the LA appendage (LAA). After VOM chemical ablation, the number of focal activation points in the LA decreased significantly (37 [interquartile range, IQR: 19–55] vs. 15 [IQR: 7–21], p < .001), and median AFCL was significantly prolonged (159 [147–168] vs. 164 [150–173] ms, p < .001). In the assessment of each segment, significant decreases in focal activation points were observed in the inferior, lateral, and anterior segments and LAA. Among the focal activation points disappearing after chemical ablation, the number in the non‐ethanol‐affected area was significantly larger than that in the affected area (13 [8–25] vs. 4 [1–10], p < .001).Conclusions: VOM chemical ablation decreases AF drivers detected by CARTOFINDER. Mechanisms other than direct myocardial damage are considered to contribute the attenuation of AF drivers.
- 20 May 2024
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 35 (7) , 1461-1470
Vein of Marshall chemical ablation decreases atrial fibrillation drivers detected by CARTOFINDER
Introduction: This study sought to elucidate the impact of vein of Marshall (VOM) chemical ablation on atrial fibrillation (AF) drivers by investigating the changes in CARTOFINDER mappings before and after VOM chemical ablation in patients with persistent AF.Methods: This study included 23 consecutive patients undergoing catheter ablation for long‐persistent AF (>18 months). VOM chemical ablation was performed following pulmonary vein isolation. CARTOFINDER and AF cycle length (AFCL) maps were created in the left atrium (LA) before and after VOM chemical ablation. The LA was divided into 8 segments, and the number of focal activation points with 6 or more repetitions was counted in each segment.Results: The number of focal activation points was largest in the LA appendage (LAA). After VOM chemical ablation, the number of focal activation points in the LA decreased significantly (37 [interquartile range, IQR: 19–55] vs. 15 [IQR: 7–21], p < .001), and median AFCL was significantly prolonged (159 [147–168] vs. 164 [150–173] ms, p < .001). In the assessment of each segment, significant decreases in focal activation points were observed in the inferior, lateral, and anterior segments and LAA. Among the focal activation points disappearing after chemical ablation, the number in the non‐ethanol‐affected area was significantly larger than that in the affected area (13 [8–25] vs. 4 [1–10], p < .001).Conclusions: VOM chemical ablation decreases AF drivers detected by CARTOFINDER. Mechanisms other than direct myocardial damage are considered to contribute the attenuation of AF drivers.
- 26 February 2024
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 35 (4) , 802-810
Delivery catheter system carries more physiological right ventricular septal pacing than stylet system
Introduction: The Mt. FUJI multicenter trial demonstrated that a delivery catheter system had a higher rate of successful right ventricular (RV) lead deployment on the RV septum (RVS) than a conventional stylet system. In this subanalysis of the Mt. FUJI trial, we assessed the differences in electrocardiogram (ECG) parameters during RV pacing between a delivery catheter system and a stylet system and their associations with the lead tip positions.Methods: Among 70 patients enrolled in the Mt FUJI trial, ECG parameters, RV lead tip positions, and lead depth inside the septum assessed by computed tomography were compared between the catheter group (n = 36) and stylet group (n = 34).Results: The paced QRS duration (QRS‐d), corrected paced QT (QTc), and JT interval (JTc) were significantly shorter in the catheter group than in the stylet group (QRS‐d: 130 ± 19 vs. 142 ± 15 ms, p = .004; QTc: 476 ± 25 vs. 514 ± 20 ms, p < .001; JTc: 347 ± 24 vs. 372 ± 17 ms, p < .001). This superiority of the catheter group was maintained in a subgroup analysis of patients with an RV lead tip position at the septum. The lead depth inside the septum was greater in the catheter group than in the stylet group, and there was a significant negative correlation between the paced QRS‐d and the lead depth.Conclusion: Using a delivery catheter system carries more physiological depolarization and repolarization during RVS pacing and deeper screw penetration in the septum in comparison to conventional stylet system. The lead depth could have a more impact on the ECG parameters rather than the type of pacing lead.
- 26 February 2024
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 35 (4) , 802-810
Delivery catheter system carries more physiological right ventricular septal pacing than stylet system
Introduction: The Mt. FUJI multicenter trial demonstrated that a delivery catheter system had a higher rate of successful right ventricular (RV) lead deployment on the RV septum (RVS) than a conventional stylet system. In this subanalysis of the Mt. FUJI trial, we assessed the differences in electrocardiogram (ECG) parameters during RV pacing between a delivery catheter system and a stylet system and their associations with the lead tip positions.Methods: Among 70 patients enrolled in the Mt FUJI trial, ECG parameters, RV lead tip positions, and lead depth inside the septum assessed by computed tomography were compared between the catheter group (n = 36) and stylet group (n = 34).Results: The paced QRS duration (QRS‐d), corrected paced QT (QTc), and JT interval (JTc) were significantly shorter in the catheter group than in the stylet group (QRS‐d: 130 ± 19 vs. 142 ± 15 ms, p = .004; QTc: 476 ± 25 vs. 514 ± 20 ms, p < .001; JTc: 347 ± 24 vs. 372 ± 17 ms, p < .001). This superiority of the catheter group was maintained in a subgroup analysis of patients with an RV lead tip position at the septum. The lead depth inside the septum was greater in the catheter group than in the stylet group, and there was a significant negative correlation between the paced QRS‐d and the lead depth.Conclusion: Using a delivery catheter system carries more physiological depolarization and repolarization during RVS pacing and deeper screw penetration in the septum in comparison to conventional stylet system. The lead depth could have a more impact on the ECG parameters rather than the type of pacing lead.
- 17 January 2024
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 35 (2) , 360-361
Perimitral conduction time: Check it before creating an empirical mitral isthmus block
- 17 January 2024
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 35 (2) , 360-361
Perimitral conduction time: Check it before creating an empirical mitral isthmus block
- 15 September 2023
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 34 (11) , 2262-2272
Unidirectional conduction characterizing epicardial connections in patients with atrial tachyarrhythmias
Introduction: Electrophysiological characteristics of epicardial connections (ECs) in atria and pulmonary veins (PVs) are unclear despite their important contributions to atrial fibrillation (AF). Unidirectional conduction associated with source‐sink mismatch can occur in ECs due to their fine fibers with abrupt changes in orientation. We detailed the prevalence and electrophysiological characteristics of unidirectional conduction in the atria and investigated its association with the clinical manifestation of AF.Methods: This study retrospectively reviewed electrophysiological studies and radiofrequency catheter ablation in 261 consecutive patients with AF.Results: Unidirectional conduction was observed during ablation encircling the PVs in eight (3.1%) patients, and all occurred in the suspected (N = 4) or definitively (N = 4) recognized ECs. These ECs included three intercaval bundles, four septopulmonary bundles, and one Marshall bundle, and were first manifested in a second procedure in 6 (75%) patients. The unidirectional property was from PV to atrium (exit conduction) in all intercaval bundles and three septopulmonary bundles, and from atrium to PV (entrance conduction) in the remaining two bundles. Intercaval bundles acted as a limb of bi‐atrial macro‐reentrant tachycardia (50%, three of the six including previous cases). Ablation of the exit outside the PVs, including the right atrium, eliminated ECs in three (38%) patients. All patients remain free from arrhythmia recurrence after a mean 13‐month follow‐up.Conclusion: A unidirectional conduction property was closely associated with the EC, as estimated by histological findings. Recognition of this fact by electrophysiologists may help to clarify mechanisms for AF and atrial tachycardia and guide the creation of efficient and safe ablation lesion sets.
- 15 September 2023
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 34 (11) , 2262-2272
Unidirectional conduction characterizing epicardial connections in patients with atrial tachyarrhythmias
Introduction: Electrophysiological characteristics of epicardial connections (ECs) in atria and pulmonary veins (PVs) are unclear despite their important contributions to atrial fibrillation (AF). Unidirectional conduction associated with source‐sink mismatch can occur in ECs due to their fine fibers with abrupt changes in orientation. We detailed the prevalence and electrophysiological characteristics of unidirectional conduction in the atria and investigated its association with the clinical manifestation of AF.Methods: This study retrospectively reviewed electrophysiological studies and radiofrequency catheter ablation in 261 consecutive patients with AF.Results: Unidirectional conduction was observed during ablation encircling the PVs in eight (3.1%) patients, and all occurred in the suspected (N = 4) or definitively (N = 4) recognized ECs. These ECs included three intercaval bundles, four septopulmonary bundles, and one Marshall bundle, and were first manifested in a second procedure in 6 (75%) patients. The unidirectional property was from PV to atrium (exit conduction) in all intercaval bundles and three septopulmonary bundles, and from atrium to PV (entrance conduction) in the remaining two bundles. Intercaval bundles acted as a limb of bi‐atrial macro‐reentrant tachycardia (50%, three of the six including previous cases). Ablation of the exit outside the PVs, including the right atrium, eliminated ECs in three (38%) patients. All patients remain free from arrhythmia recurrence after a mean 13‐month follow‐up.Conclusion: A unidirectional conduction property was closely associated with the EC, as estimated by histological findings. Recognition of this fact by electrophysiologists may help to clarify mechanisms for AF and atrial tachycardia and guide the creation of efficient and safe ablation lesion sets.
- Open Access
- 22 August 2023
- Published by Elsevier in HeartRhythm Case Reports
- Vol. 9 (11) , 785-789
Left posterolateral short atrioventricular Mahaim pathway connecting the left atrium to the left ventricular epicardium
- 22 August 2023
- Published by Elsevier in HeartRhythm Case Reports
- Vol. 9 (11) , 785-789
Open AccessLeft posterolateral short atrioventricular Mahaim pathway connecting the left atrium to the left ventricular epicardium