Changkun Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Changkun Chen has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Jie Chen
Institute of Disaster Prevention Science and Safety Technology, Central South University, Changsha, China
8 shared publicationsPeng Lei
Institute of Disaster Prevention Science & Safety Technology, Central South University, Changsha, People’s Republic of China
5 shared publicationsWeibing Jiao
5 shared publicationsYulun Zhang
Institute of Disaster Prevention Science & Safety Technology, Central South University, Changsha, People’s Republic of China
5 shared publicationsXiaolong Zhao
Central South University
4 shared publicationsCongling Shi
China Academy of Safety Science and Technology
3 shared publications
Latest Publications
- Open Access
Experimental Investigation of Flame Spread Characteristics in Cable Fires Within Covered Trays Under Different Tilt Angles
In the actual installation of cables, inclined cable laying within covered cable trays is a relatively common method. To investigate the effects of different tilt angles on the combustion behavior of cables within covered cable trays, aluminum conductor polyethylene-insulated power cables were used as the test cables. The flame morphology, temperature distribution, and fire spread rate during the cable combustion process were analyzed for experimental scenarios for which the cable laying angles and the ignition positions changed. The results indicate that the inclination angle of the covered cable tray has a significant impact on flame propagation and temperature distribution. For the ignition located at the lowest part of the cable, the fire spread rate increases significantly with the tilt angle. In contrast, for the ignition located at the highest part of the cable, the fire spread rate initially decreases slightly and then increases, with a relatively smaller overall change in magnitude. Under both ignition positions, the flame spread rate significantly increases at 15–30°. Therefore, in actual cable installation processes, cables within covered troughs should avoid large-angle inclinations.
Open AccessExperimental Investigation of Flame Spread Characteristics in Cable Fires Within Covered Trays Under Different Tilt Angles
In the actual installation of cables, inclined cable laying within covered cable trays is a relatively common method. To investigate the effects of different tilt angles on the combustion behavior of cables within covered cable trays, aluminum conductor polyethylene-insulated power cables were used as the test cables. The flame morphology, temperature distribution, and fire spread rate during the cable combustion process were analyzed for experimental scenarios for which the cable laying angles and the ignition positions changed. The results indicate that the inclination angle of the covered cable tray has a significant impact on flame propagation and temperature distribution. For the ignition located at the lowest part of the cable, the fire spread rate increases significantly with the tilt angle. In contrast, for the ignition located at the highest part of the cable, the fire spread rate initially decreases slightly and then increases, with a relatively smaller overall change in magnitude. Under both ignition positions, the flame spread rate significantly increases at 15–30°. Therefore, in actual cable installation processes, cables within covered troughs should avoid large-angle inclinations.
- Open Access
- 2 September 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 63
Experimental study on the diffusion and burning characteristics of continuous liquid fuel spillage on sloped ground in open space
- 2 September 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 63
Open AccessExperimental study on the diffusion and burning characteristics of continuous liquid fuel spillage on sloped ground in open space
- 15 August 2024
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 206
Experimental study on the effect of longitudinal ventilation on spill fire characteristics in sloped tunnels
- 15 August 2024
- Published by Elsevier in International Journal of Thermal Sciences
- Vol. 206
Experimental study on the effect of longitudinal ventilation on spill fire characteristics in sloped tunnels
- 27 June 2024
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 150 (15) , 11639-11652
Experimental study on the flame spread behavior and heat transfer model of upward-bending cable
- 27 June 2024
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 150 (15) , 11639-11652
Experimental study on the flame spread behavior and heat transfer model of upward-bending cable
- Open Access
Experimental Study on Combustion Behavior of U-Shaped Cables with Different Bending Forms and Angles
Cables are usually bent into a U-shape to cross obstacles during installation: this includes the upward-bending mode (UBM) and the downward-bending mode (DBM). An experimental study was conducted to investigate the combustion behavior of U-shaped cables with the above bending forms and different angles. The ignition point was set in the middle of the U-shaped cables and the temperature distribution, flame spread rate (FSR), mass loss rate (MLR), flame dimensional characteristics, etc. were measured and analyzed. The results showed that FSR and MLR are positively related to the bending angles, and the FSR is the highest in UBM 90°, close to 6.51 cm/min, which is four times higher than that in the bending angle 0° condition. In the UBM, the heat radiation and convection from the cable flame to the unburned region were more intense and the “eruptive fire phenomenon” occurred during the combustion process, leading to a sharp increase in the FSR in a short time. However, the thermal convection and radiation from the burning region to the unburned region were weakened in the DBM. Meanwhile, the molten outer sheath (PE) would flow along the cables, heating and igniting the unburned region in the DBM. In addition, the FSR, MLR, and peak temperature increased in the UBM compared to the DBM. The highest flame temperature occurred in UBD 90°, approximately 1023 °C.
Open AccessExperimental Study on Combustion Behavior of U-Shaped Cables with Different Bending Forms and Angles
Cables are usually bent into a U-shape to cross obstacles during installation: this includes the upward-bending mode (UBM) and the downward-bending mode (DBM). An experimental study was conducted to investigate the combustion behavior of U-shaped cables with the above bending forms and different angles. The ignition point was set in the middle of the U-shaped cables and the temperature distribution, flame spread rate (FSR), mass loss rate (MLR), flame dimensional characteristics, etc. were measured and analyzed. The results showed that FSR and MLR are positively related to the bending angles, and the FSR is the highest in UBM 90°, close to 6.51 cm/min, which is four times higher than that in the bending angle 0° condition. In the UBM, the heat radiation and convection from the cable flame to the unburned region were more intense and the “eruptive fire phenomenon” occurred during the combustion process, leading to a sharp increase in the FSR in a short time. However, the thermal convection and radiation from the burning region to the unburned region were weakened in the DBM. Meanwhile, the molten outer sheath (PE) would flow along the cables, heating and igniting the unburned region in the DBM. In addition, the FSR, MLR, and peak temperature increased in the UBM compared to the DBM. The highest flame temperature occurred in UBD 90°, approximately 1023 °C.
- 30 July 2022
- Published by Springer Nature in Fire Technology
- Vol. 60 (2) , 1163-1184
Experimental Study on Effect of Infiltration Depth on Burning Characteristic and Fuel Residual Feature of Inert Porous Media Bed Soaked by Combustible Liquid
- 30 July 2022
- Published by Springer Nature in Fire Technology
- Vol. 60 (2) , 1163-1184
Experimental Study on Effect of Infiltration Depth on Burning Characteristic and Fuel Residual Feature of Inert Porous Media Bed Soaked by Combustible Liquid
- Open Access
- 1 December 2021
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 28
Study on temperature variation and pulsation frequency of diesel-wetted wood powder fire with different fuel component ratios and burner diameters
- 1 December 2021
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 28
Open AccessStudy on temperature variation and pulsation frequency of diesel-wetted wood powder fire with different fuel component ratios and burner diameters
- Open Access
- 29 October 2021
- Published by Oxford University Press (OUP) in Transportation Safety and Environment
- Vol. 3 (4)
Experimental study on the effect of canyon cross wind on temperature distribution of buoyancy-induced smoke layer in tunnel fires
Experiments were conducted in a 1:20 arced tunnel model to investigate the effect of canyon cross wind on buoyancy-induced smoke flow characteristics of pool fires, involving smoke movement behaviour and longitudinal temperature distribution of smoke layer. The canyon wind speed, longitudinal fire location and fire size were varied. Results show that there are two special smoke behaviours with the fire source positioned at different flow field zones. When the fire source is positioned at the negative pressure zone, with increasing canyon wind speed, the smoke always exists upstream mainly due to the vortex, and the smoke temperature near the fire source increases first and then decreases. However, when the fire source is located in the transition zone and the unidirectional flow zone, there is no smoke appearing upstream with a certain canyon wind speed. Meanwhile, the smoke temperature near the fire sources are decreases with increasing canyon wind speed. The dimensionless temperature rise of the smoke layer ΔTs* along the longitudinal direction of the tunnel follows a good exponential decay. As the canyon wind speed increases, the longitudinal decay rate of ΔTs* decreases. The longitudinal decay rate of ΔTs* downstream of the fire is related to the fire location and canyon wind speed, and independent of the fire size. The empirical correlations for predicting the longitudinal decay of ΔTs* downstream of the fire are established. For a relatively large-scale fire, the longitudinal decay rate of ΔTs* upstream of the fire increases as the distance between the fire source and the upstream portal increases, especially for larger canyon wind speeds.
- 29 October 2021
- Published by Oxford University Press (OUP) in Transportation Safety and Environment
- Vol. 3 (4)
Open AccessExperimental study on the effect of canyon cross wind on temperature distribution of buoyancy-induced smoke layer in tunnel fires
Experiments were conducted in a 1:20 arced tunnel model to investigate the effect of canyon cross wind on buoyancy-induced smoke flow characteristics of pool fires, involving smoke movement behaviour and longitudinal temperature distribution of smoke layer. The canyon wind speed, longitudinal fire location and fire size were varied. Results show that there are two special smoke behaviours with the fire source positioned at different flow field zones. When the fire source is positioned at the negative pressure zone, with increasing canyon wind speed, the smoke always exists upstream mainly due to the vortex, and the smoke temperature near the fire source increases first and then decreases. However, when the fire source is located in the transition zone and the unidirectional flow zone, there is no smoke appearing upstream with a certain canyon wind speed. Meanwhile, the smoke temperature near the fire sources are decreases with increasing canyon wind speed. The dimensionless temperature rise of the smoke layer ΔTs* along the longitudinal direction of the tunnel follows a good exponential decay. As the canyon wind speed increases, the longitudinal decay rate of ΔTs* decreases. The longitudinal decay rate of ΔTs* downstream of the fire is related to the fire location and canyon wind speed, and independent of the fire size. The empirical correlations for predicting the longitudinal decay of ΔTs* downstream of the fire are established. For a relatively large-scale fire, the longitudinal decay rate of ΔTs* upstream of the fire increases as the distance between the fire source and the upstream portal increases, especially for larger canyon wind speeds.
- Open Access
- 10 March 2021
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 11 (17) , 10340-10352
Environmental investigation of pollutants in coal mine operation and waste dump area monitored in Ordos Region, China
The increasingly severe emissions of greenhouse and poisonous gases from environmentally unsafe stockpiled coal mine waste dumps have urged people from the academia as well as the industry to focus on environmental impact assessment. In this study, one-year air pollutant monitoring was conducted at the Qipanjing coalfield in Inner Mongolia of China for determining the distribution pattern statue of pollutant exposure and its main driving factors. We used FTIR spectroscopy to measure the inorganic compounds in particulate matter with a diameter of less than 2.5 μm. The spatial and temporal distribution characteristics of leading pollutants, including PM2.5, PM10, SO2, NO2, O3 and CO were analyzed. Firstly, the research showed that the temporal and spatial distribution of pollutants in the coal mine waste area is non-homogeneous. Secondly, some meteorological parameters, such as wind speed, relative humidity, temperature, and rainfall, were found to have significant effects on air pollutant distribution. Stable atmospheric conditions were unfavorable for the diffusion of pollutants and prolong the pollution process. Finally, in the vicinity of coalfields, SO2 and NO2 are present in high concentrations in air. Primary reasons for such high values are coal mining-related activities and active mine fires. This study will help to offer valuable and detailed information for understanding and interpreting the pollution source.
- 10 March 2021
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 11 (17) , 10340-10352
Open AccessEnvironmental investigation of pollutants in coal mine operation and waste dump area monitored in Ordos Region, China
The increasingly severe emissions of greenhouse and poisonous gases from environmentally unsafe stockpiled coal mine waste dumps have urged people from the academia as well as the industry to focus on environmental impact assessment. In this study, one-year air pollutant monitoring was conducted at the Qipanjing coalfield in Inner Mongolia of China for determining the distribution pattern statue of pollutant exposure and its main driving factors. We used FTIR spectroscopy to measure the inorganic compounds in particulate matter with a diameter of less than 2.5 μm. The spatial and temporal distribution characteristics of leading pollutants, including PM2.5, PM10, SO2, NO2, O3 and CO were analyzed. Firstly, the research showed that the temporal and spatial distribution of pollutants in the coal mine waste area is non-homogeneous. Secondly, some meteorological parameters, such as wind speed, relative humidity, temperature, and rainfall, were found to have significant effects on air pollutant distribution. Stable atmospheric conditions were unfavorable for the diffusion of pollutants and prolong the pollution process. Finally, in the vicinity of coalfields, SO2 and NO2 are present in high concentrations in air. Primary reasons for such high values are coal mining-related activities and active mine fires. This study will help to offer valuable and detailed information for understanding and interpreting the pollution source.
- 2 March 2021
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 28 (26) , 34489-34500
Experimental investigation of temperature distribution and spontaneous combustion tendency of coal gangue stockpiles in storage
In this study, an experimental model about the coal gangue stockpiles in semi-open storage was developed. According to the model’s requirements, the corresponding coal gangues were piled up in the factory building, the heat source and collection points were arranged, and the four operating temperatures were selected from 70 to 350 °C for heating. A series of fire experiments concerning the temperature distributions of the coal gangue piles were conducted systematically. The spontaneous combustion tendency of coal gangue samples under kinds of the four heat sources was analyzed using scanning electron microscope (SEM), thermal gravity analysis, and differential thermal gravity (TG-DTG). Under the action of thermal damage, the surface of micropores in coal gangue becomes rough. Heat accumulation is, in nature, most likely to occur near 0.1~0.4 m away from the heat source of coal pile. Simultaneously, on each of the measured flat layers, the greater the horizontal distance from the heat source is, the lower the heated temperature of gangues is, and the lower the temperature change rate is, indicating that the horizontal heat conduction is also gradually weakened. The experimental model provides an empirical basis for studying the distribution of temperature field in the depth of gangue pile and kinetics reaction mechanism of spontaneous combustion.
- 2 March 2021
- Published by Springer Nature in Environmental Science and Pollution Research
- Vol. 28 (26) , 34489-34500
Experimental investigation of temperature distribution and spontaneous combustion tendency of coal gangue stockpiles in storage
In this study, an experimental model about the coal gangue stockpiles in semi-open storage was developed. According to the model’s requirements, the corresponding coal gangues were piled up in the factory building, the heat source and collection points were arranged, and the four operating temperatures were selected from 70 to 350 °C for heating. A series of fire experiments concerning the temperature distributions of the coal gangue piles were conducted systematically. The spontaneous combustion tendency of coal gangue samples under kinds of the four heat sources was analyzed using scanning electron microscope (SEM), thermal gravity analysis, and differential thermal gravity (TG-DTG). Under the action of thermal damage, the surface of micropores in coal gangue becomes rough. Heat accumulation is, in nature, most likely to occur near 0.1~0.4 m away from the heat source of coal pile. Simultaneously, on each of the measured flat layers, the greater the horizontal distance from the heat source is, the lower the heated temperature of gangues is, and the lower the temperature change rate is, indicating that the horizontal heat conduction is also gradually weakened. The experimental model provides an empirical basis for studying the distribution of temperature field in the depth of gangue pile and kinetics reaction mechanism of spontaneous combustion.