Jeff Thiel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jeff Thiel has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
Bryan W. Cunitz
Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington,Seattle, Washington
4 shared publications- Michael R. Bailey
Department of Urology, University of Washington, Seattle, Washington
4 shared publications - Adam D. Maxwell
Department of Urology, University of Washington School of Medicine, Seattle, Washington
3 shared publications Barbrina Dunmire
Center for Industrial and Medical Ultrasound, Applied Physics Laboratory, University of Washington,Seattle, Washington
2 shared publications- Daniel F. Leotta
Applied Physics Laboratory, Center for Industrial and Medical Ultrasound, University of Washington, Seattle, WA, USA
2 shared publications - Ian Metzler
Department of Urology, University of Washington School of Medicine, Seattle, Washington
2 shared publications
Latest Publications
- 9 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (12: Breaki) , 1868-1878
Histotripsy-Induced Bactericidal Activity Correlates to Size of Cavitation Cloud In Vitro
Large abscesses are walled-off collections of pus and bacteria that often do not respond to antibiotic therapy. Standard of care involves percutaneous placement of indwelling catheter(s) for drainage, a long and uncomfortable process with high rehospitalization rates. The long-term goal of this work is to develop therapeutic ultrasound approaches to eradicate bacteria within abscesses as a noninvasive therapeutic alternative. Inertial cavitation induced by short pulses of focused ultrasound (histotripsy) is known to generate lethal mechanical damage in bacteria. Prior studies with Escherichia coli (E. coli) in suspension demonstrated that bactericidal effects increase with increasing peak negative amplitude, treatment time and duty cycle. The current study investigated correlates of bactericidal activity with histotripsy cavitation cloud size. Histotripsy was applied to E. coli suspensions in 10-mL sample vials at 810 kHz, 1.2 MHz, or 3.25 MHz for 40 minutes. The cavitation activity in the sample vials was separately observed with high-speed photography. The cavitation cloud area was quantified from those images. A linear relationship was observed between bacterial inactivation and cavitation cloud size (R 2 = 0.96), regardless of the acoustic parameters (specifically frequency, pulse duration and power) used to produce the cloud.
- 9 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (12: Breaki) , 1868-1878
Histotripsy-Induced Bactericidal Activity Correlates to Size of Cavitation Cloud In Vitro
Large abscesses are walled-off collections of pus and bacteria that often do not respond to antibiotic therapy. Standard of care involves percutaneous placement of indwelling catheter(s) for drainage, a long and uncomfortable process with high rehospitalization rates. The long-term goal of this work is to develop therapeutic ultrasound approaches to eradicate bacteria within abscesses as a noninvasive therapeutic alternative. Inertial cavitation induced by short pulses of focused ultrasound (histotripsy) is known to generate lethal mechanical damage in bacteria. Prior studies with Escherichia coli (E. coli) in suspension demonstrated that bactericidal effects increase with increasing peak negative amplitude, treatment time and duty cycle. The current study investigated correlates of bactericidal activity with histotripsy cavitation cloud size. Histotripsy was applied to E. coli suspensions in 10-mL sample vials at 810 kHz, 1.2 MHz, or 3.25 MHz for 40 minutes. The cavitation activity in the sample vials was separately observed with high-speed photography. The cavitation cloud area was quantified from those images. A linear relationship was observed between bacterial inactivation and cavitation cloud size (R 2 = 0.96), regardless of the acoustic parameters (specifically frequency, pulse duration and power) used to produce the cloud.
- Open Access
- 23 July 2024
- Published by Elsevier in WFUMB Ultrasound Open
- Vol. 2 (2)
A novel 4D volumetric M-mode ultrasound scanning technique for evaluation of intravascular volume and hemodynamic parameters
- 23 July 2024
- Published by Elsevier in WFUMB Ultrasound Open
- Vol. 2 (2)
Open AccessA novel 4D volumetric M-mode ultrasound scanning technique for evaluation of intravascular volume and hemodynamic parameters
- Open Access
- 21 March 2022
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 207 (5) , 1067-1076
Fragmentation of Stones by Burst Wave Lithotripsy in the First 19 Humans
Purpose:We report stone comminution in the first 19 human subjects by burst wave lithotripsy (BWL), which is the transcutaneous application of focused, cyclic ultrasound pulses.Materials and Method...
- 21 March 2022
- Published by Wolters Kluwer Health in Journal of Urology
- Vol. 207 (5) , 1067-1076
Open AccessFragmentation of Stones by Burst Wave Lithotripsy in the First 19 Humans
Purpose:We report stone comminution in the first 19 human subjects by burst wave lithotripsy (BWL), which is the transcutaneous application of focused, cyclic ultrasound pulses.Materials and Method...
- 1 October 2021
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 150 (4_Suppleme) , A33
Novel use of a lung ultrasound sensor for detection of lung interstitial syndrome
The number and distribution of lung ultrasound (LUS) imaging artifacts—B-lines—is correlated with the presence of lung interstitial syndrome such as viral infection, acute respiratory distress syndrome, and pulmonary edema. The detection and quantification of B-lines requires specific training and is machine and operator dependent. In select clinical scenarios continuous hands-free monitoring of lung function is preferred, e.g., COVID-19 infection. The goals of this work were to: (1) identify RF signal features associated with B-lines and (2) develop a single-element, wearable, automated non-imaging lung ultrasound sensor (LUSS) for continuous monitoring. Verasonics Ultrasound Engine with a phased array probe (4.5 MHz) was used to perform standard 10-zone LUS in ten patients with confirmed pulmonary edema, and in five healthy volunteers. The RF data corresponding to each B-mode image and a series of 35 plane wave acquisitions were collected for off-line Doppler, decorrelation, and spectral analyses. B-line thickness and number were associated with peaks of Doppler power at the pleural line. Ten 10 × 5 mm2 5 MHz LUSS, powered by custom-built multiplexed transmit-receive circuit, were fabricated and tested with the same Doppler sequence and signal processing in a lung-mimicking sponge phantom containing variable volumes of water. [Work supported by NIH R01EB023910.]
- 1 October 2021
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 150 (4_Suppleme) , A33
Novel use of a lung ultrasound sensor for detection of lung interstitial syndrome
The number and distribution of lung ultrasound (LUS) imaging artifacts—B-lines—is correlated with the presence of lung interstitial syndrome such as viral infection, acute respiratory distress syndrome, and pulmonary edema. The detection and quantification of B-lines requires specific training and is machine and operator dependent. In select clinical scenarios continuous hands-free monitoring of lung function is preferred, e.g., COVID-19 infection. The goals of this work were to: (1) identify RF signal features associated with B-lines and (2) develop a single-element, wearable, automated non-imaging lung ultrasound sensor (LUSS) for continuous monitoring. Verasonics Ultrasound Engine with a phased array probe (4.5 MHz) was used to perform standard 10-zone LUS in ten patients with confirmed pulmonary edema, and in five healthy volunteers. The RF data corresponding to each B-mode image and a series of 35 plane wave acquisitions were collected for off-line Doppler, decorrelation, and spectral analyses. B-line thickness and number were associated with peaks of Doppler power at the pleural line. Ten 10 × 5 mm2 5 MHz LUSS, powered by custom-built multiplexed transmit-receive circuit, were fabricated and tested with the same Doppler sequence and signal processing in a lung-mimicking sponge phantom containing variable volumes of water. [Work supported by NIH R01EB023910.]
- Open Access
- 1 April 2021
- Published by SAGE Publications in Journal of Endourology
- Vol. 35 (4) , 506-511
First In-Human Burst Wave Lithotripsy for Kidney Stone Comminution: Initial Two Case Studies
Purpose: To test the effectiveness (Participant A) and tolerability (Participant B) of urinary stone comminution in the first-in-human trial of a new technology, burst-wave lithotripsy (BWL). Materials and Methods: An investigational BWL and ultrasonic propulsion system was used to target a 7-mm kidney stone in the operating room before ureteroscopy (Participant A). The same system was used to target a 7.5 mm ureterovesical junction stone in clinic without anesthesia (Participant B). Results: For Participant A, a ureteroscope inserted after 9 minutes of BWL observed fragmentation of the stone to <2 mm fragments. Participant B tolerated the procedure without pain from BWL, required no anesthesia, and passed the stone on day 15. Conclusions: The first-in-human tests of BWL pulses were successful in that a renal stone was comminuted in <10 minutes, and BWL was also tolerated by an awake subject for a distal ureteral stone. Clinical Trial NCT03873259 and NCT02028559.
- 1 April 2021
- Published by SAGE Publications in Journal of Endourology
- Vol. 35 (4) , 506-511
Open AccessFirst In-Human Burst Wave Lithotripsy for Kidney Stone Comminution: Initial Two Case Studies
Purpose: To test the effectiveness (Participant A) and tolerability (Participant B) of urinary stone comminution in the first-in-human trial of a new technology, burst-wave lithotripsy (BWL). Materials and Methods: An investigational BWL and ultrasonic propulsion system was used to target a 7-mm kidney stone in the operating room before ureteroscopy (Participant A). The same system was used to target a 7.5 mm ureterovesical junction stone in clinic without anesthesia (Participant B). Results: For Participant A, a ureteroscope inserted after 9 minutes of BWL observed fragmentation of the stone to <2 mm fragments. Participant B tolerated the procedure without pain from BWL, required no anesthesia, and passed the stone on day 15. Conclusions: The first-in-human tests of BWL pulses were successful in that a renal stone was comminuted in <10 minutes, and BWL was also tolerated by an awake subject for a distal ureteral stone. Clinical Trial NCT03873259 and NCT02028559.
- 5 February 2018
- Published by Springer Nature in Nature Medicine
- Vol. 24 (3) , 368-374
Congenital Zika virus infection as a silent pathology with loss of neurogenic output in the fetal brain
Zika virus infection of pregnant nonhuman primates results in the loss of fetal neuronal progenitor cells, even in the absence of overt microcephaly. Zika virus (ZIKV) is a flavivirus with teratogenic effects on fetal brain, but the spectrum of ZIKV-induced brain injury is unknown, particularly when ultrasound imaging is normal. In a pregnant pigtail macaque (Macaca nemestrina) model of ZIKV infection, we demonstrate that ZIKV-induced injury to fetal brain is substantial, even in the absence of microcephaly, and may be challenging to detect in a clinical setting. A common and subtle injury pattern was identified, including (i) periventricular T2-hyperintense foci and loss of fetal noncortical brain volume, (ii) injury to the ependymal epithelium with underlying gliosis and (iii) loss of late fetal neuronal progenitor cells in the subventricular zone (temporal cortex) and subgranular zone (dentate gyrus, hippocampus) with dysmorphic granule neuron patterning. Attenuation of fetal neurogenic output demonstrates potentially considerable teratogenic effects of congenital ZIKV infection even without microcephaly. Our findings suggest that all children exposed to ZIKV in utero should receive long-term monitoring for neurocognitive deficits, regardless of head size at birth.
- 5 February 2018
- Published by Springer Nature in Nature Medicine
- Vol. 24 (3) , 368-374
Congenital Zika virus infection as a silent pathology with loss of neurogenic output in the fetal brain
Zika virus infection of pregnant nonhuman primates results in the loss of fetal neuronal progenitor cells, even in the absence of overt microcephaly. Zika virus (ZIKV) is a flavivirus with teratogenic effects on fetal brain, but the spectrum of ZIKV-induced brain injury is unknown, particularly when ultrasound imaging is normal. In a pregnant pigtail macaque (Macaca nemestrina) model of ZIKV infection, we demonstrate that ZIKV-induced injury to fetal brain is substantial, even in the absence of microcephaly, and may be challenging to detect in a clinical setting. A common and subtle injury pattern was identified, including (i) periventricular T2-hyperintense foci and loss of fetal noncortical brain volume, (ii) injury to the ependymal epithelium with underlying gliosis and (iii) loss of late fetal neuronal progenitor cells in the subventricular zone (temporal cortex) and subgranular zone (dentate gyrus, hippocampus) with dysmorphic granule neuron patterning. Attenuation of fetal neurogenic output demonstrates potentially considerable teratogenic effects of congenital ZIKV infection even without microcephaly. Our findings suggest that all children exposed to ZIKV in utero should receive long-term monitoring for neurocognitive deficits, regardless of head size at birth.
- Open Access
- 1 September 2016
- Published by SAGE Publications in Journal of Endourology
- Vol. 30 (9) , 958-962
Stone-Mode Ultrasound for Determining Renal Stone Size
Purpose The purpose of this study was to measure the accuracy of stone-specific algorithms (S-mode) and the posterior acoustic shadow for determining kidney stone size with ultrasound in-vivo. Materials and methods Thirty-four subjects with 115 renal stones were prospectively recruited and scanned with S-mode on a research ultrasound (US) system. S-mode is gray-scale US adjusted to enhance stone contrast and resolution by minimizing compression and averaging, and increasing line density and frequency. Stone and shadow width were compared to a recent computed tomography (CT) scan and, in five subjects with 18 stones, S-mode was compared to a clinical US system. Results Overall, 84% of stones identified on CT were detected on S-mode and 66% of these shadowed. Seventy-three percent of the stone measurements and 85% of the shadow measurements were within 2 mm of the size on CT. A posterior acoustic shadow was present in 89% of stones over 5 mm versus 53% of stones under 5 mm. S-mode visualized 78% of stones, versus 61% for the clinical system. S-mode stone and shadow measurements differed from CT by 1.6 ± 1.0 mm and 0.8 ± 0.6 mm, respectively, compared with 2.0 ± 1.5 mm and 1.6 ± 1.0 mm for the clinical system. Conclusions S-mode offers improved visualization and sizing of renal stones. With S-mode, sizing of the stone itself and the posterior acoustic shadow were similarly accurate. Stones that do not shadow are most likely <5 mm and small enough to pass spontaneously.
- 1 September 2016
- Published by SAGE Publications in Journal of Endourology
- Vol. 30 (9) , 958-962
Open AccessStone-Mode Ultrasound for Determining Renal Stone Size
Purpose The purpose of this study was to measure the accuracy of stone-specific algorithms (S-mode) and the posterior acoustic shadow for determining kidney stone size with ultrasound in-vivo. Materials and methods Thirty-four subjects with 115 renal stones were prospectively recruited and scanned with S-mode on a research ultrasound (US) system. S-mode is gray-scale US adjusted to enhance stone contrast and resolution by minimizing compression and averaging, and increasing line density and frequency. Stone and shadow width were compared to a recent computed tomography (CT) scan and, in five subjects with 18 stones, S-mode was compared to a clinical US system. Results Overall, 84% of stones identified on CT were detected on S-mode and 66% of these shadowed. Seventy-three percent of the stone measurements and 85% of the shadow measurements were within 2 mm of the size on CT. A posterior acoustic shadow was present in 89% of stones over 5 mm versus 53% of stones under 5 mm. S-mode visualized 78% of stones, versus 61% for the clinical system. S-mode stone and shadow measurements differed from CT by 1.6 ± 1.0 mm and 0.8 ± 0.6 mm, respectively, compared with 2.0 ± 1.5 mm and 1.6 ± 1.0 mm for the clinical system. Conclusions S-mode offers improved visualization and sizing of renal stones. With S-mode, sizing of the stone itself and the posterior acoustic shadow were similarly accurate. Stones that do not shadow are most likely <5 mm and small enough to pass spontaneously.
- 1 December 2015
- Published by Wolters Kluwer Health in Ultrasound Quarterly
- Vol. 31 (4) , 243-249
Variability in Stiffness Assessment in a Thyroid Nodule Using Shear Wave Imaging
Purpose The aim of the study was to assess intrareader and interreader variability in placing a region of interest in the elastography color map in the thyroid nodule. Method and Materials After institutional review board approval, elastograms were obtained by shear wave elastography from 38 individuals, with a total of 60 thyroid nodules. Two readers reviewed all images while blinded to the cytopathology or final histopathology results and to each other's measurements. For each image, readers first performed a qualitative assessment and recorded presence of stiff region(s) and number of stiff regions. Then, they placed a 3-mm circular region of interest on the stiffest region to quantify the mean and maximum stiffness in kilopascals. Intrareader and interreader agreement was summarized for categorical variables using Cohen κ and for continuous variables using the concordance correlation coefficient (CCC) and coefficient of variation. Results There was good overall intrareader and interreader agreement for the presence of stiff regions and number of stiff regions after classifying them as 0, 1, and greater than 1 regions (κ = 0.78–0.81 and 0.74–0.79, respectively). There was also good overall agreement for the the following quantitative measurements: mean kPa (CCC = 0.97 and 0.93) and max kPa (CCC = 0.97 and 0.93). The intrareader and interreader coefficient of variation was 13% and 21% for mean kPa and 14% and 21% for max kPa. Conclusions There can be differences in measurement of stiffness by 2 different operators in softer nodules with shear wave imaging because of the lack of brighter areas on the color elastograms. A standardized technique is necessary to be able to compare results from 1 study to the next.
- 1 December 2015
- Published by Wolters Kluwer Health in Ultrasound Quarterly
- Vol. 31 (4) , 243-249
Variability in Stiffness Assessment in a Thyroid Nodule Using Shear Wave Imaging
Purpose The aim of the study was to assess intrareader and interreader variability in placing a region of interest in the elastography color map in the thyroid nodule. Method and Materials After institutional review board approval, elastograms were obtained by shear wave elastography from 38 individuals, with a total of 60 thyroid nodules. Two readers reviewed all images while blinded to the cytopathology or final histopathology results and to each other's measurements. For each image, readers first performed a qualitative assessment and recorded presence of stiff region(s) and number of stiff regions. Then, they placed a 3-mm circular region of interest on the stiffest region to quantify the mean and maximum stiffness in kilopascals. Intrareader and interreader agreement was summarized for categorical variables using Cohen κ and for continuous variables using the concordance correlation coefficient (CCC) and coefficient of variation. Results There was good overall intrareader and interreader agreement for the presence of stiff regions and number of stiff regions after classifying them as 0, 1, and greater than 1 regions (κ = 0.78–0.81 and 0.74–0.79, respectively). There was also good overall agreement for the the following quantitative measurements: mean kPa (CCC = 0.97 and 0.93) and max kPa (CCC = 0.97 and 0.93). The intrareader and interreader coefficient of variation was 13% and 21% for mean kPa and 14% and 21% for max kPa. Conclusions There can be differences in measurement of stiffness by 2 different operators in softer nodules with shear wave imaging because of the lack of brighter areas on the color elastograms. A standardized technique is necessary to be able to compare results from 1 study to the next.