Frank G. Shellock
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Frank G. Shellock has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
- Blake Titterington
Loyola Marymount University, 1 LMU Drive, Los Angeles, CA 90045
2 shared publications - Bozena Culo
Loyola Marymount University, 1 LMU Drive, Los Angeles, CA 90045, United States of America
2 shared publications John V. Crues
ProNet Imaging Medical Group and RadNet Management Los Angeles California USA
2 shared publicationsAleksandar N. Nacev
Promaxo Oakland California USA
1 shared publicationAlireza Hatamifar
Department of Chemistry and Biochemistry, Seaver College of Science and Engineering, Loyola Marymount University, Los Angeles, CA
1 shared publicationAndrew Webb
Department of Radiology Leiden University Medical Center Leiden Netherlands
1 shared publication
Latest Publications
- 31 July 2025
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (10) , 2131
Clinical Use of the Swoop Portable MR Imaging System
We have a large clinical experience (>500 patients) with the ultra-low-field, portable brain MRI (Swoop Portable MR Imaging System, Hyperfine; www.hyperfine.io). This video article gives an overview of the scanner characteristics, scan procedure, and representative clinical images obtained from our experience. The portable MRI system is a useful adjunct to high-field MRI for critically ill patients, avoiding the time and risks associated with moving critically ill patients and their life support teams from the intensive care unit to the conventional scanner. The ultra-low-field environment also allows for decreased susceptibility artifacts and improved safety, allowing patients with active and passive medical devices to have diagnostic MRI, which may not be otherwise available. We demonstrate substantial artifact reduction from extensive dental amalgam as well as safe scanning of a patient with a non-MR-conditional pacemaker. The ability to detect contrast enhancement at ultra-low-field with standard-dose IV gadolinium is also shown.
- 31 July 2025
- Published by American Society of Neuroradiology (ASNR) in American Journal of Neuroradiology
- Vol. 46 (10) , 2131
Clinical Use of the Swoop Portable MR Imaging System
We have a large clinical experience (>500 patients) with the ultra-low-field, portable brain MRI (Swoop Portable MR Imaging System, Hyperfine; www.hyperfine.io). This video article gives an overview of the scanner characteristics, scan procedure, and representative clinical images obtained from our experience. The portable MRI system is a useful adjunct to high-field MRI for critically ill patients, avoiding the time and risks associated with moving critically ill patients and their life support teams from the intensive care unit to the conventional scanner. The ultra-low-field environment also allows for decreased susceptibility artifacts and improved safety, allowing patients with active and passive medical devices to have diagnostic MRI, which may not be otherwise available. We demonstrate substantial artifact reduction from extensive dental amalgam as well as safe scanning of a patient with a non-MR-conditional pacemaker. The ability to detect contrast enhancement at ultra-low-field with standard-dose IV gadolinium is also shown.
- Open Access
- 4 July 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 61 (4) , 1633-1634
Transitioning From the 5 Gauss to the 9 Gauss Threshold to Prevent Unintended Programming Changes for Certain Active Implants
- 4 July 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 61 (4) , 1633-1634
Open AccessTransitioning From the 5 Gauss to the 9 Gauss Threshold to Prevent Unintended Programming Changes for Certain Active Implants
- 28 May 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 60 (6) , 2341-2342
Editorial for “Auditory Effects of Acoustic Noise From 3‐T Brain MRI in Neonates With Hearing Protection”
- 28 May 2024
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 60 (6) , 2341-2342
Editorial for “Auditory Effects of Acoustic Noise From 3‐T Brain MRI in Neonates With Hearing Protection”
- Open Access
- 28 September 2023
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 59 (5) , 1514-1522
Managing Patients With Unlabeled Passive Implants on MR Systems Operating Below 1.5 T
The standard of care for managing a patient with an implant is to identify the item and to assess the relative safety of scanning the patient. Because the 1.5 T MR system is the most prevalent scanner in the world and 3 T is the highest field strength in widespread use, implants typically have “MR Conditional” (i.e., an item with demonstrated safety in the MR environment within defined conditions) labeling at 1.5 and/or 3 T only. This presents challenges for a facility that has a scanner operating at a field strength below 1.5 T when encountering a patient with an implant, because scanning the patient is considered “off‐label.” In this case, the supervising physician is responsible for deciding whether to scan the patient based on the risks associated with the implant and the benefit of magnetic resonance imaging (MRI). For a passive implant, the MRI safety‐related concerns are static magnetic field interactions (i.e., force and torque) and radiofrequency (RF) field‐induced heating. The worldwide utilization of scanners operating below 1.5 T combined with the increasing incidence of patients with implants that need MRI creates circumstances that include patients potentially being subjected to unsafe imaging conditions or being denied access to MRI because physicians often lack the knowledge to perform an assessment of risk vs. benefit. Thus, physicians must have a complete understanding of the MRI‐related safety issues that impact passive implants when managing patients with these products on scanners operating below 1.5 T. This monograph provides an overview of the various clinical MR systems operating below 1.5 T and discusses the MRI‐related factors that influence safety for passive implants. Suggestions are provided for the management of patients with passive implants labeled MR Conditional at 1.5 and/or 3 T, referred to scanners operating below 1.5 T. The purpose of this information is to empower supervising physicians with the essential knowledge to perform MRI exams confidently and safely in patients with passive implants.Level of Evidence: 1Technical Efficacy: Stage 3
- 28 September 2023
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 59 (5) , 1514-1522
Open AccessManaging Patients With Unlabeled Passive Implants on MR Systems Operating Below 1.5 T
The standard of care for managing a patient with an implant is to identify the item and to assess the relative safety of scanning the patient. Because the 1.5 T MR system is the most prevalent scanner in the world and 3 T is the highest field strength in widespread use, implants typically have “MR Conditional” (i.e., an item with demonstrated safety in the MR environment within defined conditions) labeling at 1.5 and/or 3 T only. This presents challenges for a facility that has a scanner operating at a field strength below 1.5 T when encountering a patient with an implant, because scanning the patient is considered “off‐label.” In this case, the supervising physician is responsible for deciding whether to scan the patient based on the risks associated with the implant and the benefit of magnetic resonance imaging (MRI). For a passive implant, the MRI safety‐related concerns are static magnetic field interactions (i.e., force and torque) and radiofrequency (RF) field‐induced heating. The worldwide utilization of scanners operating below 1.5 T combined with the increasing incidence of patients with implants that need MRI creates circumstances that include patients potentially being subjected to unsafe imaging conditions or being denied access to MRI because physicians often lack the knowledge to perform an assessment of risk vs. benefit. Thus, physicians must have a complete understanding of the MRI‐related safety issues that impact passive implants when managing patients with these products on scanners operating below 1.5 T. This monograph provides an overview of the various clinical MR systems operating below 1.5 T and discusses the MRI‐related factors that influence safety for passive implants. Suggestions are provided for the management of patients with passive implants labeled MR Conditional at 1.5 and/or 3 T, referred to scanners operating below 1.5 T. The purpose of this information is to empower supervising physicians with the essential knowledge to perform MRI exams confidently and safely in patients with passive implants.Level of Evidence: 1Technical Efficacy: Stage 3
- 7 June 2022
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 92, 82-87
Near field communication (NFC) device: Evaluation of MRI issues
- 7 June 2022
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 92, 82-87
Near field communication (NFC) device: Evaluation of MRI issues
- 1 May 2020
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 295 (2) , 314-315
MRI and Patients with Non–MRI-conditional Cardiac Devices: Further Evidence of Safety
- 1 May 2020
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 295 (2) , 314-315
MRI and Patients with Non–MRI-conditional Cardiac Devices: Further Evidence of Safety
- 1 March 2020
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 214 (3) , 524-528
MRI Evaluation of an Atrial-Anchored Transcatheter Mitral Valve Replacement Implant
OBJECTIVE. A medical implant that is made from metal must undergo proper MRI testing to ensure patient safety. The purpose of this investigation was to assess issues with MRI with a newly developed...
- 1 March 2020
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 214 (3) , 524-528
MRI Evaluation of an Atrial-Anchored Transcatheter Mitral Valve Replacement Implant
OBJECTIVE. A medical implant that is made from metal must undergo proper MRI testing to ensure patient safety. The purpose of this investigation was to assess issues with MRI with a newly developed...
- 1 February 2020
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 66, 219-225
MRI safety and imaging artifacts evaluated for a cannulated screw used for guided growth surgery
- 1 February 2020
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 66, 219-225
MRI safety and imaging artifacts evaluated for a cannulated screw used for guided growth surgery
- Open Access
- 1 July 2019
- Published by Georg Thieme Verlag KG in Archives of Plastic Surgery
- Vol. 46 (04) , 375-380
Reconsidering the “MR Unsafe” breast tissue expander with magnetic infusion port: A case report and literature review
Breast tissue expanders (TEs) with magnetic infusion ports are labeled “MR Unsafe.” Therefore, patients with these implants are typically prevented from undergoing magnetic resonance imaging (MRI). We report a patient with a total submuscular breast TE who inadvertently underwent an MRI exam. She subsequently developed expander exposure, requiring explantation and autologous reconstruction. The safety profile of TEs with magnetic ports and the use of MRI in patients with these implants is surprisingly controversial. Therefore, we present our case report, a systematic literature review, and propose procedural guidelines to help ensure the safety of patients with TEs with magnetic ports that need to undergo MRI exams.
- 1 July 2019
- Published by Georg Thieme Verlag KG in Archives of Plastic Surgery
- Vol. 46 (04) , 375-380
Open AccessReconsidering the “MR Unsafe” breast tissue expander with magnetic infusion port: A case report and literature review
Breast tissue expanders (TEs) with magnetic infusion ports are labeled “MR Unsafe.” Therefore, patients with these implants are typically prevented from undergoing magnetic resonance imaging (MRI). We report a patient with a total submuscular breast TE who inadvertently underwent an MRI exam. She subsequently developed expander exposure, requiring explantation and autologous reconstruction. The safety profile of TEs with magnetic ports and the use of MRI in patients with these implants is surprisingly controversial. Therefore, we present our case report, a systematic literature review, and propose procedural guidelines to help ensure the safety of patients with TEs with magnetic ports that need to undergo MRI exams.
- 12 November 2018
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 57, 250-253
Assessment of metallic patient support devices and other items at 7-Tesla: Findings applied to 46 additional devices
- 12 November 2018
- Published by Elsevier in Magnetic Resonance Imaging
- Vol. 57, 250-253
Assessment of metallic patient support devices and other items at 7-Tesla: Findings applied to 46 additional devices