Arijit Banerjee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Arijit Banerjee has a total of 88 co-authors. Here are the top co-authors by number of shared publications:
Steven B. Leeb
Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA, USA
12 shared publicationsJames L. Kirtley
Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, USA
10 shared publicationsShivang Agrawal
University of Illinois at Urbana-Champaign,Department of Electrical and Computer EngineeringUrbanaUSA
7 shared publications- Elie Libbos
Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
6 shared publications - Phuc Thanh Huynh
Electrical & Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois United States 61801
6 shared publications - Anuj Maheshwari
Department of Electrical and Computer Engineering, University of Illinois Urbana-Champaign, Urbana, IL, USA
5 shared publications
Latest Publications
- Open Access
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 1819-1829
Galvanically Isolated Measurement of SiC MOSFET Health in Electronic Power Converters
Wide band-gap semiconductors like silicon carbide (SiC) provide significant advantages over traditional silicon in power converter applications but their reliability continues to lag silicon MOSFETs making them difficult to deploy in critical infrastructure. In particular, bond-wire connections on SiC chips are prone to degradation due to the mismatch in thermal expansion coefficients between the wire material and the SiC substrate. Previous work by the authors and others have developed in-situ techniques to track MOSFET health, but are limited to monitoring a single device which increases the converter size and cost. This paper introduces a galvanically isolated measurement technique that enables a single circuit to monitor a pair of complementary switched MOSFETs, reducing the overhead of health monitoring by up to 50%. Evaluation of the design in an 800 V half bridge configuration shows measurement sensitivity sufficient to detect single bond-wire liftoff of typical SiC devices in both high and low side switch positions.
- 2 June 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Open Journal of Power Electronics
- Vol. 7, 1819-1829
Open AccessGalvanically Isolated Measurement of SiC MOSFET Health in Electronic Power Converters
Wide band-gap semiconductors like silicon carbide (SiC) provide significant advantages over traditional silicon in power converter applications but their reliability continues to lag silicon MOSFETs making them difficult to deploy in critical infrastructure. In particular, bond-wire connections on SiC chips are prone to degradation due to the mismatch in thermal expansion coefficients between the wire material and the SiC substrate. Previous work by the authors and others have developed in-situ techniques to track MOSFET health, but are limited to monitoring a single device which increases the converter size and cost. This paper introduces a galvanically isolated measurement technique that enables a single circuit to monitor a pair of complementary switched MOSFETs, reducing the overhead of health monitoring by up to 50%. Evaluation of the design in an 800 V half bridge configuration shows measurement sensitivity sufficient to detect single bond-wire liftoff of typical SiC devices in both high and low side switch positions.
- Open Access
- 10 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
Effects of Winding Asymmetry on Power Quality in Multiport Integrated Generator Rectifiers
Permanent magnet-based multiport integrated generator-rectifiers are well-suited for high-power generator applications due to their reliability, efficiency, and power density. However, the winding pattern of these generators introduces an imbalance in the mutual inductances between phases, resulting in second-order harmonics in the dc output current of the rectifier. This paper presents a dynamic model to explain the effects of these imbalances on the harmonic performance of the output dc power. Sequence component networks are derived to quantify the dc current ripple in terms of the unequal mutual inductances of the active port winding. A feedforward-based control strategy is proposed to reduce the current ripple, thereby compensating for asymmetry in the active port control system, and improving the quality of dc power delivered to the grid. The proposed concepts are validated through simulations of a 4-port, 120 kW prototype generator-rectifier system, with experimental validation performed on the same machine at a scaled-down power level.
- 10 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. PP (21686777) , 1
Open AccessEffects of Winding Asymmetry on Power Quality in Multiport Integrated Generator Rectifiers
Permanent magnet-based multiport integrated generator-rectifiers are well-suited for high-power generator applications due to their reliability, efficiency, and power density. However, the winding pattern of these generators introduces an imbalance in the mutual inductances between phases, resulting in second-order harmonics in the dc output current of the rectifier. This paper presents a dynamic model to explain the effects of these imbalances on the harmonic performance of the output dc power. Sequence component networks are derived to quantify the dc current ripple in terms of the unequal mutual inductances of the active port winding. A feedforward-based control strategy is proposed to reduce the current ripple, thereby compensating for asymmetry in the active port control system, and improving the quality of dc power delivered to the grid. The proposed concepts are validated through simulations of a 4-port, 120 kW prototype generator-rectifier system, with experimental validation performed on the same machine at a scaled-down power level.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Electronics Magazine
- Vol. 12 (4) , 119-124
IEEE PELS University Lab Kits Democratize Hands-On Power Electronics Education [Expert View]
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Power Electronics Magazine
- Vol. 12 (4) , 119-124
IEEE PELS University Lab Kits Democratize Hands-On Power Electronics Education [Expert View]
- Open Access
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (6) , 9295-9306
Modulation Depth Maximization for High Phase Count Drives With Emphasis on Variable Pole Operation
High-phase-count machines are well known to have reduced dc bus utilization compared to conventional three-phase drives. High-phase-count machines for fault tolerance and variable-pole induction machine drives are two examples. Variable-pole machines need more than three phases to support electronic pole changing. This article proposes two complementary approaches to improve variable pole induction machine base speed and high-speed torque capability. Base speed improvement is achieved with a modulation technique that increases dc bus utilization by 11.5% for the highest operating pole count. An optimization framework for loss minimization is developed considering the simultaneous operation of multiple poles and cases, including no synchronization between operating poles, stator flux synchronization, and stator voltage synchronization. The framework shows that voltage synchronization improves torque by 49.5% at maximum operating speed. A proposed control architecture enables one pole configuration to operate under vector control and others under scalar control, thereby eliminating parameter dependence for stator voltage synchronization. Experimental results on a toroidally wound 36-slot machine validate the proposed modulation strategy, control architecture, and high-speed torque improvement from synchronized stator voltage injection.
- 19 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (6) , 9295-9306
Open AccessModulation Depth Maximization for High Phase Count Drives With Emphasis on Variable Pole Operation
High-phase-count machines are well known to have reduced dc bus utilization compared to conventional three-phase drives. High-phase-count machines for fault tolerance and variable-pole induction machine drives are two examples. Variable-pole machines need more than three phases to support electronic pole changing. This article proposes two complementary approaches to improve variable pole induction machine base speed and high-speed torque capability. Base speed improvement is achieved with a modulation technique that increases dc bus utilization by 11.5% for the highest operating pole count. An optimization framework for loss minimization is developed considering the simultaneous operation of multiple poles and cases, including no synchronization between operating poles, stator flux synchronization, and stator voltage synchronization. The framework shows that voltage synchronization improves torque by 49.5% at maximum operating speed. A proposed control architecture enables one pole configuration to operate under vector control and others under scalar control, thereby eliminating parameter dependence for stator voltage synchronization. Experimental results on a toroidally wound 36-slot machine validate the proposed modulation strategy, control architecture, and high-speed torque improvement from synchronized stator voltage injection.
- Open Access
- 1 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 13584-13602
A Composite Converter Architecture for Wind Energy Systems Connected to AC Grid
A composite converter architecture consisting of a multiport generator and a set of power electronic converters is proposed for a wind energy system tied to an ac grid. The generated power is delivered to the grid by way of two paths: one via a passive rectifier and line-frequency inverter, and the other through an active rectifier and an inverter operating at switching frequencies higher than their respective fundamental frequencies, with the maximum power processed only 10% of the rated power. The remaining power is processed using the line-frequency path, employing reliable, efficient, and inexpensive diodes and switches. An analytical design framework shows that the high-frequency switch volt-ampere rating can be reduced by 67.9%. This results in an overall loss reduction ranging between 46.8% and 53% depending on the extracted power. Control and modulation strategies and a maximum power point tracking algorithm are presented. Experimental results obtained from a laboratory prototype validate the performance and the effectiveness of the proposed converter architecture, and its control and modulation strategies. This approach opens up opportunities for integrating ac-collection networks through an efficient, reliable, and cost-effective energy conversion system.
- 1 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (9) , 13584-13602
Open AccessA Composite Converter Architecture for Wind Energy Systems Connected to AC Grid
A composite converter architecture consisting of a multiport generator and a set of power electronic converters is proposed for a wind energy system tied to an ac grid. The generated power is delivered to the grid by way of two paths: one via a passive rectifier and line-frequency inverter, and the other through an active rectifier and an inverter operating at switching frequencies higher than their respective fundamental frequencies, with the maximum power processed only 10% of the rated power. The remaining power is processed using the line-frequency path, employing reliable, efficient, and inexpensive diodes and switches. An analytical design framework shows that the high-frequency switch volt-ampere rating can be reduced by 67.9%. This results in an overall loss reduction ranging between 46.8% and 53% depending on the extracted power. Control and modulation strategies and a maximum power point tracking algorithm are presented. Experimental results obtained from a laboratory prototype validate the performance and the effectiveness of the proposed converter architecture, and its control and modulation strategies. This approach opens up opportunities for integrating ac-collection networks through an efficient, reliable, and cost-effective energy conversion system.
- Open Access
- 4 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (1) , 652-664
Control Architecture for LLC Resonant Converters With High Input Disturbance Rejection Capability Using Output Diode Current
The controller design for the LLC resonant dc–dc converter is challenging due to the large number of poles whose locations vary with operating conditions. A controller's ability to reject input disturbance is required to reduce the input filter size, increase power density, and improve reliability. This article presents a control architecture utilizing the output diode current measurement that reduces the control-to-output transfer function for an LLC resonant converter to first order and provides a high degree of input voltage disturbance rejection with a marginal increase in implementation complexity. The increased disturbance rejection allows the reduction of the bulky dc-link capacitance at the output of the PFC in electric vehicle battery charging application. A small-signal model for the proposed control variable is derived, and loop analysis using a Bode plot highlights the advantages of the proposed method. Simulation results verify the proposed architecture's high disturbance rejection capabilities. The proposed control architecture is evaluated using a 1-kW front-end power factor correction (PFC) rectifier followed by an LLC resonant converter with an intermediate dc-link voltage of 400 V. The proposed approach achieves a 4.5× reduction in the energy storage requirement in the intermediate dc-link compared to direct frequency control without sacrificing output voltage ripple and efficiency of the LLC stage and total harmonic distortion at the input of the PFC stage.
- 4 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (1) , 652-664
Open AccessControl Architecture for LLC Resonant Converters With High Input Disturbance Rejection Capability Using Output Diode Current
The controller design for the LLC resonant dc–dc converter is challenging due to the large number of poles whose locations vary with operating conditions. A controller's ability to reject input disturbance is required to reduce the input filter size, increase power density, and improve reliability. This article presents a control architecture utilizing the output diode current measurement that reduces the control-to-output transfer function for an LLC resonant converter to first order and provides a high degree of input voltage disturbance rejection with a marginal increase in implementation complexity. The increased disturbance rejection allows the reduction of the bulky dc-link capacitance at the output of the PFC in electric vehicle battery charging application. A small-signal model for the proposed control variable is derived, and loop analysis using a Bode plot highlights the advantages of the proposed method. Simulation results verify the proposed architecture's high disturbance rejection capabilities. The proposed control architecture is evaluated using a 1-kW front-end power factor correction (PFC) rectifier followed by an LLC resonant converter with an intermediate dc-link voltage of 400 V. The proposed approach achieves a 4.5× reduction in the energy storage requirement in the intermediate dc-link compared to direct frequency control without sacrificing output voltage ripple and efficiency of the LLC stage and total harmonic distortion at the input of the PFC stage.
- Open Access
- 21 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (12) , 16659-16672
In Situ Detection of Bond Wire Lift-Off Events in Operational SiC MOSFETs
Bond wire lift-off is one of the main failure mechanisms for silicon carbide mosfet s. This occurs when the metallurgical weld between the bond-wire and the device source breaks creating an open circuit. The higher current on the remaining wires subjects them to additional thermal stress creating a positive feedback loop that can quickly lead to device failure if left unchecked. By detecting lift-off events during power converter operation damaged devices can be de-rated and equipment operators can be alerted to replace the power module before a failure occurs. This article presents an online, in situ monitoring circuit that can detect the incremental change in on-state inductance ( ${L_{\text{ds}}}$ ) caused by the redistribution of bond-wire current after a lift-off occurs. Unlike on-state resistance ( ${R_{\text{ds}}}$ ), the inductance does not depend on temperature, gate-oxide health, or gate-bias level. In addition, since the inductive impedance is frequency dependent, any bias related to converter operation can be suppressed by increasing the measurement frequency well above the switching frequency. Experimental results show that the proposed circuit can accurately measure inductive changes down to 10 pH, providing sufficient sensitivity to detect single wire lift-off events in test devices.
- 21 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 39 (12) , 16659-16672
Open AccessIn Situ Detection of Bond Wire Lift-Off Events in Operational SiC MOSFETs
Bond wire lift-off is one of the main failure mechanisms for silicon carbide mosfet s. This occurs when the metallurgical weld between the bond-wire and the device source breaks creating an open circuit. The higher current on the remaining wires subjects them to additional thermal stress creating a positive feedback loop that can quickly lead to device failure if left unchecked. By detecting lift-off events during power converter operation damaged devices can be de-rated and equipment operators can be alerted to replace the power module before a failure occurs. This article presents an online, in situ monitoring circuit that can detect the incremental change in on-state inductance ( ${L_{\text{ds}}}$ ) caused by the redistribution of bond-wire current after a lift-off occurs. Unlike on-state resistance ( ${R_{\text{ds}}}$ ), the inductance does not depend on temperature, gate-oxide health, or gate-bias level. In addition, since the inductive impedance is frequency dependent, any bias related to converter operation can be suppressed by increasing the measurement frequency well above the switching frequency. Experimental results show that the proposed circuit can accurately measure inductive changes down to 10 pH, providing sufficient sensitivity to detect single wire lift-off events in test devices.
- 8 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (3) , 2274-2284
Optimal Torque Angle for a Switched Brushless Doubly Fed Reluctance Machine
A brushless doubly fed reluctance machine (BDFRM) offers several advantages over a single-port machine since it requires a partially rated power converter, provides reduced maintenance, and operates without permanent magnets. A conventional design approach for BDFRMs considers equal electrical loadings on both of its windings and a torque angle of 90o, which are an extension of typical constraints for uniform air-gap sinusoidal machines. However, these constraints in BDFRM sacrifice torque density. Accounting for effect of the rotor flux-barriers on the mean and ripple torque, the optimization framework proposes a candidate design having unequal electrical loadings and a torque angle of 117o to maximize torque density. It is shown that the optimal design is capable of producing 84% more torque as compared to the conventional design approach. This article, first, shows that a torque angle of greater than 90o is required to maximize the torque-producing component of secondary stator current using space phasors. Next, a switched-drive architecture is described that reconfigures one of the stator excitations on the fly to enable a wide-speed range operation. Online reconfiguration extends the use of BDFRM to many wide-speed range applications, such as propulsion systems, while preserving the benefit of fractionally rated power electronics. Using the switched-drive architecture can reduce the converter voltage rating by 47% as compared to the conventional-drive for the prototype BDFRM. The experimental results are provided to validate the proposed analytical approach.
- 8 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (3) , 2274-2284
Optimal Torque Angle for a Switched Brushless Doubly Fed Reluctance Machine
A brushless doubly fed reluctance machine (BDFRM) offers several advantages over a single-port machine since it requires a partially rated power converter, provides reduced maintenance, and operates without permanent magnets. A conventional design approach for BDFRMs considers equal electrical loadings on both of its windings and a torque angle of 90o, which are an extension of typical constraints for uniform air-gap sinusoidal machines. However, these constraints in BDFRM sacrifice torque density. Accounting for effect of the rotor flux-barriers on the mean and ripple torque, the optimization framework proposes a candidate design having unequal electrical loadings and a torque angle of 117o to maximize torque density. It is shown that the optimal design is capable of producing 84% more torque as compared to the conventional design approach. This article, first, shows that a torque angle of greater than 90o is required to maximize the torque-producing component of secondary stator current using space phasors. Next, a switched-drive architecture is described that reconfigures one of the stator excitations on the fly to enable a wide-speed range operation. Online reconfiguration extends the use of BDFRM to many wide-speed range applications, such as propulsion systems, while preserving the benefit of fractionally rated power electronics. Using the switched-drive architecture can reduce the converter voltage rating by 47% as compared to the conventional-drive for the prototype BDFRM. The experimental results are provided to validate the proposed analytical approach.
- Open Access
- 28 June 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 254
Electro-thermal co-design of a variable pole toroidal induction motor
- 28 June 2024
- Published by Elsevier in Applied Thermal Engineering
- Vol. 254
Open AccessElectro-thermal co-design of a variable pole toroidal induction motor
- 13 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (2) , 1273-1285
Modeling and Control of a Bioinspired, Distributed Electromechanical Actuator System Emulating a Biological Spine
The robotic spine has a lot of potential for snake-like, quadruped, and humanoid robots, as it can improve their mobility, flexibility, and overall function. A common approach to developing an articulated spine uses geared motors to imitate vertebrae. Instead of using geared motors that rotate 360 degree, a bioinspired gearless electromechanical actuator was proposed and developed as an alternative, specifically for humanoid spine applications. The actuator trades off angular flexibility for torque, while the geared motor trades off speed for torque. This article compares the proposed actuator and conventional geared motors regarding torque, acceleration, and copper loss for a vertebra's angular flexibility. When its angular flexibility is lower than 14 $^\circ$ , the proposed actuator achieves higher torque capability without gears than with conventional motors. Lower angular flexibility, which means smaller airgaps, allows the proposed actuator to produce a much stronger torque for the same input power. The actuator's nonlinear electrical and mechanical dynamics models are developed and used for position control of a six-module distributed spine. In addition, two different position-control architectures are developed: an outer loop proportional-integral (PI) position controller with an inner loop PI current controller and an outer loop PI position controller with an inner loop PI torque controller.
- 13 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE/ASME Transactions on Mechatronics
- Vol. 30 (2) , 1273-1285
Modeling and Control of a Bioinspired, Distributed Electromechanical Actuator System Emulating a Biological Spine
The robotic spine has a lot of potential for snake-like, quadruped, and humanoid robots, as it can improve their mobility, flexibility, and overall function. A common approach to developing an articulated spine uses geared motors to imitate vertebrae. Instead of using geared motors that rotate 360 degree, a bioinspired gearless electromechanical actuator was proposed and developed as an alternative, specifically for humanoid spine applications. The actuator trades off angular flexibility for torque, while the geared motor trades off speed for torque. This article compares the proposed actuator and conventional geared motors regarding torque, acceleration, and copper loss for a vertebra's angular flexibility. When its angular flexibility is lower than 14 $^\circ$ , the proposed actuator achieves higher torque capability without gears than with conventional motors. Lower angular flexibility, which means smaller airgaps, allows the proposed actuator to produce a much stronger torque for the same input power. The actuator's nonlinear electrical and mechanical dynamics models are developed and used for position control of a six-module distributed spine. In addition, two different position-control architectures are developed: an outer loop proportional-integral (PI) position controller with an inner loop PI current controller and an outer loop PI position controller with an inner loop PI torque controller.