Dilip Kumar Agarwal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Dilip Kumar Agarwal has a total of 58 co-authors. Here are the top co-authors by number of shared publications:
- Vinayak P. Dravid
Department of Materials Science and Engineering Northwestern University Evanston Illinois USA
5 shared publications - Gajendra S. Shekhawat
Northwestern University
4 shared publications - Arindam Kushagra
Birla Institute of Technology and Science, Pilani, Hyderabad Campus, Medchal
2 shared publications - Egon Anderson Ozer
Division of Infectious Diseases, Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA
2 shared publications - Judd Franklin Hultquist
Division of Infectious Diseases, Northwestern University Feinberg School of Medicine, Chicago, IL 60611, USA
2 shared publications - Julius B. Lucks
Northwestern University
2 shared publications
Latest Publications
- 23 March 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 280, 117395
Nanomechanical systems for the rapid detection of HIV-1 p24 antigen
- 23 March 2025
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 280, 117395
Nanomechanical systems for the rapid detection of HIV-1 p24 antigen
- 24 February 2025
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 19 (9) , 9096-9106
Ultrasensitive Water Contaminant Detection with Transcription Factor Interfaced Microcantilevers
Water contamination by harmful chemicals is a growing global concern, creating a need to develop technologies that can detect a range of target compounds at the required concentrations. Here, we address this need by merging biological allosteric transcription factors with DNA-coated nanomechanical microcantilevers to detect chemicals in water with a digital readout. After proof-of-concept demonstration and optimization to detect anhydrotetracycline with the TetR transcription factor, we use the CadC transcription factor to detect Pb2+ and Cd2+ in water at concentrations down to 2 and 1 ppb, respectively, in less than 15 min. A computational model suggests this improvement in sensitivity could be achieved by the DNA-coated microcantilever surface changing the transcription factor binding properties. Our findings demonstrate a promising approach for water quality monitoring with fast, highly sensitive, digital readout.
- 24 February 2025
- Published by American Chemical Society (ACS) in ACS Nano
- Vol. 19 (9) , 9096-9106
Ultrasensitive Water Contaminant Detection with Transcription Factor Interfaced Microcantilevers
Water contamination by harmful chemicals is a growing global concern, creating a need to develop technologies that can detect a range of target compounds at the required concentrations. Here, we address this need by merging biological allosteric transcription factors with DNA-coated nanomechanical microcantilevers to detect chemicals in water with a digital readout. After proof-of-concept demonstration and optimization to detect anhydrotetracycline with the TetR transcription factor, we use the CadC transcription factor to detect Pb2+ and Cd2+ in water at concentrations down to 2 and 1 ppb, respectively, in less than 15 min. A computational model suggests this improvement in sensitivity could be achieved by the DNA-coated microcantilever surface changing the transcription factor binding properties. Our findings demonstrate a promising approach for water quality monitoring with fast, highly sensitive, digital readout.
- Open Access
Ultra-sensitive water contaminant detection with transcription factor interfaced microcantilevers
Water contamination is a growing global concern, creating a need to develop technologies that can detect a range of target compounds at the required thresholds. Here, we address this need by merging biological allosteric transcription factors with DNA coated nanomechanical microcantilevers to detect chemicals in water with digital readout. After proof-of-concept demonstration and optimization to detect tetracycline with the TetR transcription factor, we use the CadC transcription factor to detect Pb 2+ and Cd 2+ in water at concentrations down to 2 ppb and 1 ppb, respectively, in less than fifteen minutes. A computational model suggests this improvement in sensitivity could be achieved by the DNA coated microcantilever surface changing transcription factor binding properties. Our findings demonstrate a promising new approach for water quality monitoring with fast, highly sensitive, digital readouts.
Open AccessUltra-sensitive water contaminant detection with transcription factor interfaced microcantilevers
Water contamination is a growing global concern, creating a need to develop technologies that can detect a range of target compounds at the required thresholds. Here, we address this need by merging biological allosteric transcription factors with DNA coated nanomechanical microcantilevers to detect chemicals in water with digital readout. After proof-of-concept demonstration and optimization to detect tetracycline with the TetR transcription factor, we use the CadC transcription factor to detect Pb 2+ and Cd 2+ in water at concentrations down to 2 ppb and 1 ppb, respectively, in less than fifteen minutes. A computational model suggests this improvement in sensitivity could be achieved by the DNA coated microcantilever surface changing transcription factor binding properties. Our findings demonstrate a promising new approach for water quality monitoring with fast, highly sensitive, digital readouts.
- Open Access
- 31 July 2023
- Published by Royal Society of Chemistry (RSC) in RSC Medicinal Chemistry
- Vol. 14 (9) , 1722-1733
De novodesign of a stapled peptide targeting SARS-CoV-2 spike protein receptor-binding domain
Binding configuration of ade novostapled peptide on SARS-CoV-2 spike protein, as predicted by molecular simulation. Stapled residues enhance peptide stability while interacting residues engage key amino acids on the protein receptor-binding domain.
- 31 July 2023
- Published by Royal Society of Chemistry (RSC) in RSC Medicinal Chemistry
- Vol. 14 (9) , 1722-1733
Open AccessDe novodesign of a stapled peptide targeting SARS-CoV-2 spike protein receptor-binding domain
Binding configuration of ade novostapled peptide on SARS-CoV-2 spike protein, as predicted by molecular simulation. Stapled residues enhance peptide stability while interacting residues engage key amino acids on the protein receptor-binding domain.
- Open Access
- 12 June 2023
- Published by CAB PUBLISHER in International Journal of Medical and Biomedical Studies
- Vol. 7 (6) , 01-10
Process Validation of Paracetamol Tablets: A Comprehensive Study Based on ICH Guidelines
This research paper aims to provide a comprehensive understanding of the process validation of Paracetamol tablets according to the guidelines outlined by the International Council for Harmonisation of Technical Requirements forPharmaceuticals for Human Use (ICH). Paracetamol is a widely used analgesic and antipyretic drug, and ensuring the quality, safety, and efficacy of its dosage form is of utmost importance. This study encompasses the three stages of process validation, namely process design, process qualification, and continued process verification, with a focus oncritical parameters and attributes. The article also explores the role of regulatory guidelines, such as the ICH Q8 (R2), Q9,and Q10, in facilitating effective process validation. (1) Key words: Process Validation, ICH, CPP, CQA, SPC, Change Control, VMP;
- 12 June 2023
- Published by CAB PUBLISHER in International Journal of Medical and Biomedical Studies
- Vol. 7 (6) , 01-10
Open AccessProcess Validation of Paracetamol Tablets: A Comprehensive Study Based on ICH Guidelines
This research paper aims to provide a comprehensive understanding of the process validation of Paracetamol tablets according to the guidelines outlined by the International Council for Harmonisation of Technical Requirements forPharmaceuticals for Human Use (ICH). Paracetamol is a widely used analgesic and antipyretic drug, and ensuring the quality, safety, and efficacy of its dosage form is of utmost importance. This study encompasses the three stages of process validation, namely process design, process qualification, and continued process verification, with a focus oncritical parameters and attributes. The article also explores the role of regulatory guidelines, such as the ICH Q8 (R2), Q9,and Q10, in facilitating effective process validation. (1) Key words: Process Validation, ICH, CPP, CQA, SPC, Change Control, VMP;
- 2 June 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (23) , 8105-8109
Rapid and Sensitive Detection of Antigen from SARS-CoV-2 Variants of Concern by a Multivalent Minibinder-Functionalized Nanomechanical Sensor
New platforms for the rapid and sensitive detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants of concern are urgently needed. Here we report the development of a nanomechanical sensor based on the deflection of a microcantilever capable of detecting the SARS-CoV-2 spike (S) glycoprotein antigen using computationally designed multivalent minibinders immobilized on a microcantilever surface. The sensor exhibits rapid (<5 min) detection of the target antigens down to concentrations of 0.05 ng/mL (362 fM) and is more than an order of magnitude more sensitive than an antibody-based cantilever sensor. Validation of the sensor with clinical samples from 33 patients, including 9 patients infected with the Omicron (BA.1) variant observed detection of antigen from nasopharyngeal swabs with cycle threshold (Ct) values as high as 39, suggesting a limit of detection similar to that of the quantitative reverse transcription polymerase chain reaction (RT-qPCR). Our findings demonstrate the use of minibinders and nanomechanical sensors for the rapid and sensitive detection of SARS-CoV-2 and potentially other disease markers.
- 2 June 2022
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 94 (23) , 8105-8109
Rapid and Sensitive Detection of Antigen from SARS-CoV-2 Variants of Concern by a Multivalent Minibinder-Functionalized Nanomechanical Sensor
New platforms for the rapid and sensitive detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) variants of concern are urgently needed. Here we report the development of a nanomechanical sensor based on the deflection of a microcantilever capable of detecting the SARS-CoV-2 spike (S) glycoprotein antigen using computationally designed multivalent minibinders immobilized on a microcantilever surface. The sensor exhibits rapid (<5 min) detection of the target antigens down to concentrations of 0.05 ng/mL (362 fM) and is more than an order of magnitude more sensitive than an antibody-based cantilever sensor. Validation of the sensor with clinical samples from 33 patients, including 9 patients infected with the Omicron (BA.1) variant observed detection of antigen from nasopharyngeal swabs with cycle threshold (Ct) values as high as 39, suggesting a limit of detection similar to that of the quantitative reverse transcription polymerase chain reaction (RT-qPCR). Our findings demonstrate the use of minibinders and nanomechanical sensors for the rapid and sensitive detection of SARS-CoV-2 and potentially other disease markers.
- 17 September 2021
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 195, 113647
Highly sensitive and ultra-rapid antigen-based detection of SARS-CoV-2 using nanomechanical sensor platform
- 17 September 2021
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 195, 113647
Highly sensitive and ultra-rapid antigen-based detection of SARS-CoV-2 using nanomechanical sensor platform
- Open Access
- 14 January 2020
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 30 (2) , 025009
A study of surface stress and flexural rigidity of symmetrically and asymmetrically biofunctionalized microcantilevers
Dynamic sensing using microcantilevers has held the centre stage for a long time in biomolecular detection. In this work, we have reported a comparative study of dynamic responses of asymmetric (top or bottom surface) and symmetric (both top and bottom surfaces) modifications (biofunctionalization) of silicon nitride/oxide microcantilevers. For the first time, surface stress (in terms of surface energy/area) has been shown to govern the change in resonant frequency by studying the dynamic responses of asymmetrically and symmetrically modified microcantilevers using a conventional laser doppler vibrometer. The resonant frequency of asymmetrically modified microcantilever was found to be lower than that of symmetrically modified one by a magnitude of ~0.4 kHz. Also, it was observed that the amplitude of oscillation increased from symmetrically modified to asymmetrically modified microcantilever. Consequentially, we have reported (by means of mathematical calculations and nanoindentation experiments) the increase in flexural rigidity as well as surface stress from symmetric modification to the asymmetric one. Owing to the decrease in the resonant frequencies as well as downward bending of microcantilevers, we conclude that compressive surface stress is developed after surface modifications. This work will be of immense interest to the researchers working in the field of dynamic sensing using MEMS-based sensors.
- 14 January 2020
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 30 (2) , 025009
Open AccessA study of surface stress and flexural rigidity of symmetrically and asymmetrically biofunctionalized microcantilevers
Dynamic sensing using microcantilevers has held the centre stage for a long time in biomolecular detection. In this work, we have reported a comparative study of dynamic responses of asymmetric (top or bottom surface) and symmetric (both top and bottom surfaces) modifications (biofunctionalization) of silicon nitride/oxide microcantilevers. For the first time, surface stress (in terms of surface energy/area) has been shown to govern the change in resonant frequency by studying the dynamic responses of asymmetrically and symmetrically modified microcantilevers using a conventional laser doppler vibrometer. The resonant frequency of asymmetrically modified microcantilever was found to be lower than that of symmetrically modified one by a magnitude of ~0.4 kHz. Also, it was observed that the amplitude of oscillation increased from symmetrically modified to asymmetrically modified microcantilever. Consequentially, we have reported (by means of mathematical calculations and nanoindentation experiments) the increase in flexural rigidity as well as surface stress from symmetric modification to the asymmetric one. Owing to the decrease in the resonant frequencies as well as downward bending of microcantilevers, we conclude that compressive surface stress is developed after surface modifications. This work will be of immense interest to the researchers working in the field of dynamic sensing using MEMS-based sensors.
- 24 December 2019
- Published by IOP Publishing in Nanotechnology
- Vol. 31 (11) , 115503
Sensitive detection of cardiac troponin-I protein using fabricated piezoresistive microcantilevers by a novel method of asymmetric biofunctionalization
Microcantilever-based sensor platform has attracted a lot of attention over the time in detection of a variety of molecules due to their miniaturized dimensions. Sensitivity enhancement is an important aspect of such sensors, especially when used for point-of-care diagnostic purpose. However, the major concern while operating these sensors in deflection mode is their sensitivity which mainly relies on selective chemical modification protocols employed on these sensor surfaces. One of the ways of getting better sensitivity is through asymmetric (one side) biofunctionalization of the sensor surface. In the presented work here, we have demonstrated a novel approach of asymmetric biofunctionalization of proteins in overall sensitivity enhancement of piezoresistive silicon nitride-oxide microcantilever sensor platform inside a flow chamber. Herein, using our developed surface chemistry, asymmetrically biofunctionalized microcantilevers first exhibited a greater electrical response in terms of piezoresistance change than their symmetric counterpart in the detection of human immunoglobulins (HIgGs) protein. Finally, these microcantilevers were employed to exhibit the enhanced sensitivity towards the detection of a crucial cardiac marker protein, i.e. Troponin-I (cTnI) down to 250 ng ml −1 using asymmetric biofunctionalization process. This study shows that the developed asymmetric biofunctionalization methodology may be used as a general protocol to detect other important biomarkers of clinical applications with improved sensitivity.
- 24 December 2019
- Published by IOP Publishing in Nanotechnology
- Vol. 31 (11) , 115503
Sensitive detection of cardiac troponin-I protein using fabricated piezoresistive microcantilevers by a novel method of asymmetric biofunctionalization
Microcantilever-based sensor platform has attracted a lot of attention over the time in detection of a variety of molecules due to their miniaturized dimensions. Sensitivity enhancement is an important aspect of such sensors, especially when used for point-of-care diagnostic purpose. However, the major concern while operating these sensors in deflection mode is their sensitivity which mainly relies on selective chemical modification protocols employed on these sensor surfaces. One of the ways of getting better sensitivity is through asymmetric (one side) biofunctionalization of the sensor surface. In the presented work here, we have demonstrated a novel approach of asymmetric biofunctionalization of proteins in overall sensitivity enhancement of piezoresistive silicon nitride-oxide microcantilever sensor platform inside a flow chamber. Herein, using our developed surface chemistry, asymmetrically biofunctionalized microcantilevers first exhibited a greater electrical response in terms of piezoresistance change than their symmetric counterpart in the detection of human immunoglobulins (HIgGs) protein. Finally, these microcantilevers were employed to exhibit the enhanced sensitivity towards the detection of a crucial cardiac marker protein, i.e. Troponin-I (cTnI) down to 250 ng ml −1 using asymmetric biofunctionalization process. This study shows that the developed asymmetric biofunctionalization methodology may be used as a general protocol to detect other important biomarkers of clinical applications with improved sensitivity.
- Open Access
- 20 November 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 8 (1) , 18-26
A label-free aptasensor FET based on Au nanoparticle decorated Co 3 O 4 nanorods and a SWCNT layer for detection of cardiac troponin T protein
Acute myocardial infarction (AMI) is a serious health problem that must be identified in its early stages. Considerable progress has been made in understanding the condition of AMI through ascertaining the role of biomarkers, such as myoglobin, cardiac troponin proteins (T and I), creatine kinase-MB, and fatty acid-binding protein (FABP). A field-effect transistor (FET) is an effective platform; however, innovations are required in all layers of the FET for it to become robust and highly sensitive. For the first time, we made use of the synergistic combination of noble metal nanoparticles (AuNPs) with Co3O4 for the detection of cardiac troponin T (cTnT) in a FET platform. We determined the morphology of Au-decorated Co3O4 NRs and their electronic properties by characterizing the channel layer using electron microscopies and transient measurements. Subsequently, we performed the detection of cardiac troponin T by immobilizing its complementary biotinylated DNA aptamer on the channel surface using a drop-casting method. To understand the changes in drain current caused by this interaction, we probed our SWCNT–Co3O4 NR transistor with limited gate and drain bias (≤1 V), achieving a sensitivity of 0.5 μA μg−1 mL−1 for the Au-decorated NRs. A 250% increase in the sensitivity and a limit of detection (LOD) of 0.1 μg mL−1 were achieved by using this device. Finally, selectivity studies proved that this synergistic combination works well in the FET configuration for the successful detection of cTnT.
- 20 November 2019
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 8 (1) , 18-26
Open AccessA label-free aptasensor FET based on Au nanoparticle decorated Co 3 O 4 nanorods and a SWCNT layer for detection of cardiac troponin T protein
Acute myocardial infarction (AMI) is a serious health problem that must be identified in its early stages. Considerable progress has been made in understanding the condition of AMI through ascertaining the role of biomarkers, such as myoglobin, cardiac troponin proteins (T and I), creatine kinase-MB, and fatty acid-binding protein (FABP). A field-effect transistor (FET) is an effective platform; however, innovations are required in all layers of the FET for it to become robust and highly sensitive. For the first time, we made use of the synergistic combination of noble metal nanoparticles (AuNPs) with Co3O4 for the detection of cardiac troponin T (cTnT) in a FET platform. We determined the morphology of Au-decorated Co3O4 NRs and their electronic properties by characterizing the channel layer using electron microscopies and transient measurements. Subsequently, we performed the detection of cardiac troponin T by immobilizing its complementary biotinylated DNA aptamer on the channel surface using a drop-casting method. To understand the changes in drain current caused by this interaction, we probed our SWCNT–Co3O4 NR transistor with limited gate and drain bias (≤1 V), achieving a sensitivity of 0.5 μA μg−1 mL−1 for the Au-decorated NRs. A 250% increase in the sensitivity and a limit of detection (LOD) of 0.1 μg mL−1 were achieved by using this device. Finally, selectivity studies proved that this synergistic combination works well in the FET configuration for the successful detection of cTnT.