Amanda Spraggs-Hughes
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Amanda Spraggs-Hughes has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
William M. Ricci
7 shared publicationsChristopher M. McAndrew
6 shared publications- Michael J. Gardner
Department of Orthopedic Surgery, Stanford University School of Medicine, Palo Alto, CA
6 shared publications Steven M. Cherney
Department of Orthopaedic Surgery, University of Arkansas for Medical Science, Little Rock, AR;†Department of Orthopaedic Surgery, Washington University School of Medicine, St. Louis, MO; and‡Department of Orthopaedic Surgery, Stanford University School of Medicine, Redwood City, CA
4 shared publicationsChristopher T. Cosgrove
Department of Orthopaedic Surgery, Washington University School of Medicine, St. Louis, MO
3 shared publicationsMichael J. Gardner
3 shared publications
Latest Publications
- Open Access
- 3 July 2025
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 5 (4) , 693-698
Representation of female authorship among American Shoulder and Elbow Surgeons meetings from 2008 to 2022
- 3 July 2025
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 5 (4) , 693-698
Open AccessRepresentation of female authorship among American Shoulder and Elbow Surgeons meetings from 2008 to 2022
- 1 November 2019
- Published by Elsevier in Journal of Surgical Education
- Vol. 76 (6) , 1484-1491
Cross-Sectional Survey Results on Mental Health Among Orthopedic Surgery Residents Across North America
- 1 November 2019
- Published by Elsevier in Journal of Surgical Education
- Vol. 76 (6) , 1484-1491
Cross-Sectional Survey Results on Mental Health Among Orthopedic Surgery Residents Across North America
- 15 April 2019
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 27 (8) , 287-294
Clinical Practice Guidelines in Action: Differences in Femoral Neck Fracture Management by Trauma and Arthroplasty Training
Introduction: The purpose of this study was to survey trauma and arthroplasty surgeons to investigate associations between subspecialty training and management of geriatric femoral neck fractures and to compare treatments with the American Academy of Orthopaedic Surgeons clinical practice guidelines. Methods: Five hundred fifty-six surgeons completed the online survey consisting of two sections: (1) surgeon demographics and (2) two geriatric hip fracture cases with questions regarding treatment decisions. Results: In both clinical scenarios, arthroplasty surgeons were more likely than trauma surgeons to recommend total hip arthroplasty (THA) (case 1: 96% versus 84%; case 2: 29% versus 10%; P ≤ 0.02) and spinal anesthesia (case 1: 70% versus 40%; case 2: 62% versus 38%; P < 0.01). Surgeons who have made changes based on clinical practice guidelines (n = 96; 21% of surveyed) cited more use of THA (n = 56; 58% of respondents) and cemented stems (n = 28; 29% of respondents). Conclusion: Arthroplasty surgeons are more likely to recommend THA over hemiarthroplasty and have a higher expectation for spinal anesthesia for the management of geriatric femoral neck fractures.
- 15 April 2019
- Published by Wolters Kluwer Health in Journal of the American Academy of Orthopaedic Surgeons
- Vol. 27 (8) , 287-294
Clinical Practice Guidelines in Action: Differences in Femoral Neck Fracture Management by Trauma and Arthroplasty Training
Introduction: The purpose of this study was to survey trauma and arthroplasty surgeons to investigate associations between subspecialty training and management of geriatric femoral neck fractures and to compare treatments with the American Academy of Orthopaedic Surgeons clinical practice guidelines. Methods: Five hundred fifty-six surgeons completed the online survey consisting of two sections: (1) surgeon demographics and (2) two geriatric hip fracture cases with questions regarding treatment decisions. Results: In both clinical scenarios, arthroplasty surgeons were more likely than trauma surgeons to recommend total hip arthroplasty (THA) (case 1: 96% versus 84%; case 2: 29% versus 10%; P ≤ 0.02) and spinal anesthesia (case 1: 70% versus 40%; case 2: 62% versus 38%; P < 0.01). Surgeons who have made changes based on clinical practice guidelines (n = 96; 21% of surveyed) cited more use of THA (n = 56; 58% of respondents) and cemented stems (n = 28; 29% of respondents). Conclusion: Arthroplasty surgeons are more likely to recommend THA over hemiarthroplasty and have a higher expectation for spinal anesthesia for the management of geriatric femoral neck fractures.
- 1 October 2018
- Published by Elsevier in Value in Health
- Vol. 21, S306-S307
PMS110 - RESEARCH APPLICATIONS OF PATIENT REPORTED OUTCOME MEASURES IN AN ACADEMIC ORTHOPAEDIC SURGERY DEPARTMENT
- 1 October 2018
- Published by Elsevier in Value in Health
- Vol. 21, S306-S307
PMS110 - RESEARCH APPLICATIONS OF PATIENT REPORTED OUTCOME MEASURES IN AN ACADEMIC ORTHOPAEDIC SURGERY DEPARTMENT
- 1 October 2018
- Published by Elsevier in Value in Health
- Vol. 21, S357
PRM8 - CLINICAL APPLICATION AND USAGE OF PATIENT REPORTED OUTCOME MEASURES IN AN ORTHOPAEDIC OUTPATIENT SETTING
- 1 October 2018
- Published by Elsevier in Value in Health
- Vol. 21, S357
PRM8 - CLINICAL APPLICATION AND USAGE OF PATIENT REPORTED OUTCOME MEASURES IN AN ORTHOPAEDIC OUTPATIENT SETTING
- 1 July 2018
- Published by Elsevier in Clinical Biomechanics
- Vol. 56, 46-51
In-vivo stiffness assessment of distal femur fracture locked plating constructs
- 1 July 2018
- Published by Elsevier in Clinical Biomechanics
- Vol. 56, 46-51
In-vivo stiffness assessment of distal femur fracture locked plating constructs
- 1 July 2018
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 32 (7) , 361-367
A Novel Indirect Reduction Technique in Ankle Syndesmotic Injuries: A Cadaveric Study
Objective: To describe a novel technique using preoperative computed tomography (CT) to plan clamp tine placement along the trans-syndesmotic axis (TSA). We hypothesized that preoperative CT imaging provides a reliable template on which to plan optimal clamp tine positioning along the TSA, reducing malreduction rates compared with other described techniques. Methods: CT images of 48 cadaveric through-knee specimens were obtained, and the TSA was measured as well as the optimal position of the medial clamp tine. The syndesmosis was then fully destabilized. Indirect clamp reductions were performed with the medial clamp tine placed at positions 10 degrees anterior to the TSA, along the TSA, and at both 10 and 20 degrees posterior to the TSA. The specimens were then separately reduced using manual digital pressure and palpation alone. CT was performed after each clamp and manual reduction. Results: On average, reduction clamp tines were within 3 ± 2 degrees of the desired angle and within 5% ± 4% of the templated location along the tibial line for all clamp reduction attempts. Palpation and direct visualization produced the overall lowest malreduction rates in all measurements: 4.9% and 3.0%, respectively. Off-axis clamping 10 degrees anterior or 20 degrees posterior to the patient-specific TSA demonstrated an increased overall malreduction rate: 15.8% and 11.3%, respectively. Significantly more over-compression occurred when a reduction clamp was used versus manual digital reduction alone (8.6% vs. 0%). Conclusions: Reduction clamp placement directly along an optimal clamping vector can be facilitated by preoperative CT measurements of the uninjured ankle. However, even in this setting, the use of reduction clamps increases the risk for syndesmotic malreduction and over-compression compared with manual digital reduction or direct visualization.
- 1 July 2018
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 32 (7) , 361-367
A Novel Indirect Reduction Technique in Ankle Syndesmotic Injuries: A Cadaveric Study
Objective: To describe a novel technique using preoperative computed tomography (CT) to plan clamp tine placement along the trans-syndesmotic axis (TSA). We hypothesized that preoperative CT imaging provides a reliable template on which to plan optimal clamp tine positioning along the TSA, reducing malreduction rates compared with other described techniques. Methods: CT images of 48 cadaveric through-knee specimens were obtained, and the TSA was measured as well as the optimal position of the medial clamp tine. The syndesmosis was then fully destabilized. Indirect clamp reductions were performed with the medial clamp tine placed at positions 10 degrees anterior to the TSA, along the TSA, and at both 10 and 20 degrees posterior to the TSA. The specimens were then separately reduced using manual digital pressure and palpation alone. CT was performed after each clamp and manual reduction. Results: On average, reduction clamp tines were within 3 ± 2 degrees of the desired angle and within 5% ± 4% of the templated location along the tibial line for all clamp reduction attempts. Palpation and direct visualization produced the overall lowest malreduction rates in all measurements: 4.9% and 3.0%, respectively. Off-axis clamping 10 degrees anterior or 20 degrees posterior to the patient-specific TSA demonstrated an increased overall malreduction rate: 15.8% and 11.3%, respectively. Significantly more over-compression occurred when a reduction clamp was used versus manual digital reduction alone (8.6% vs. 0%). Conclusions: Reduction clamp placement directly along an optimal clamping vector can be facilitated by preoperative CT measurements of the uninjured ankle. However, even in this setting, the use of reduction clamps increases the risk for syndesmotic malreduction and over-compression compared with manual digital reduction or direct visualization.
- 1 January 2018
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 32 (1) , 43-51
Functional Outcomes of Syndesmotic Injuries Based on Objective Reduction Accuracy at a Minimum 1-Year Follow-Up
Objective: To evaluate whether objective syndesmosis reduction predicts functional outcomes and pain scores in patients with operatively treated syndesmotic injuries at a minimum 1-year follow-up. Design: Prospective Cohort. Setting: Urban Level I Trauma Center. Patients: Sixty-nine patients with operatively treated syndesmotic injuries were initially identified and consented for inclusion in the study. Nine patients were excluded perioperatively. Twelve patients were lost to follow-up. Forty-eight patients with operatively treated unilateral syndesmotic injuries were available and participated at the final follow-up. Intervention: Trans-syndesmotic stabilization with either 1 or 2 quadricortical position screws. Postoperatively, bilateral ankle computed tomography scans were obtained to objectively assess syndesmosis reduction accuracy. Main Outcome Measurements: Olerud–Molander Ankle Score, Short Musculoskeletal Function Assessment Dysfunction Index and Bother Index, and Numeric Pain Rating Scales at a minimum 1-year postoperative follow-up. Results: At 1-year follow-up, there was no significant difference in functional outcomes between reduced and malreduced groups at the 1.5-, 2-, and 3-mm thresholds for linear measurements. Similarly, there was no functional difference between the reduced and malreduced groups for rotational malreductions at a 10 or 15 degrees threshold. Patients with state-sponsored insurance (Medicaid) had significantly worse functional scores and pain scores when compared with the groups with private insurance, Medicare, or no insurance. Conclusions: At 1-year follow-up, functional outcomes were not related to objective measures of syndesmosis reduction. Level of Evidence: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.
- 1 January 2018
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 32 (1) , 43-51
Functional Outcomes of Syndesmotic Injuries Based on Objective Reduction Accuracy at a Minimum 1-Year Follow-Up
Objective: To evaluate whether objective syndesmosis reduction predicts functional outcomes and pain scores in patients with operatively treated syndesmotic injuries at a minimum 1-year follow-up. Design: Prospective Cohort. Setting: Urban Level I Trauma Center. Patients: Sixty-nine patients with operatively treated syndesmotic injuries were initially identified and consented for inclusion in the study. Nine patients were excluded perioperatively. Twelve patients were lost to follow-up. Forty-eight patients with operatively treated unilateral syndesmotic injuries were available and participated at the final follow-up. Intervention: Trans-syndesmotic stabilization with either 1 or 2 quadricortical position screws. Postoperatively, bilateral ankle computed tomography scans were obtained to objectively assess syndesmosis reduction accuracy. Main Outcome Measurements: Olerud–Molander Ankle Score, Short Musculoskeletal Function Assessment Dysfunction Index and Bother Index, and Numeric Pain Rating Scales at a minimum 1-year postoperative follow-up. Results: At 1-year follow-up, there was no significant difference in functional outcomes between reduced and malreduced groups at the 1.5-, 2-, and 3-mm thresholds for linear measurements. Similarly, there was no functional difference between the reduced and malreduced groups for rotational malreductions at a 10 or 15 degrees threshold. Patients with state-sponsored insurance (Medicaid) had significantly worse functional scores and pain scores when compared with the groups with private insurance, Medicare, or no insurance. Conclusions: At 1-year follow-up, functional outcomes were not related to objective measures of syndesmosis reduction. Level of Evidence: Prognostic Level II. See Instructions for Authors for a complete description of levels of evidence.
- 1 August 2017
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 31 (8) , 440-446
Medial Clamp Tine Positioning Affects Ankle Syndesmosis Malreduction
Objectives: To determine whether the position of the medial clamp tine during syndesmotic reduction affected reduction accuracy. Design: Prospective cohort. Setting: Urban Level 1 trauma center. Patients: Seventy-two patients with operatively treated syndesmotic injuries. Intervention: Patients underwent operative fixation of their ankle syndesmotic injuries using reduction forceps. The position of the medial clamp tine was then recorded with intraoperative fluoroscopy. Malreduction rates were then assessed with bilateral ankle computerized tomography. Main Outcome Measurement: Fibular position within the incisura was measured with respect to the uninjured side to determine whether a malreduction had occurred. Malreductions were then analyzed for associations with injury pattern, patient demographics, and the location of the medial clamp tine. Results: A statistically significant association was found between medial clamp position and sagittal plane syndesmosis malreduction. In reference to anterior fibular translation, there was a 0% malreduction rate in the 18 patients where the clamp tine was placed in the anterior third, a 19.4% malreduction rate in the middle third, and 60% malreduction rate in the posterior third (P = 0.006). In reference to posterior fibular translation, there was a 11.1% malreduction when clamp placement was in the anterior third, a 16.1% malreduction rate in the middle third, and 60% malreduction rate in the posterior third (P = 0.062). There were no significant associations between medial clamp position and coronal plane malreductions (overcompression or undercompression) (P = 1). Conclusions: When using reduction forceps for syndesmotic reduction, the position of the medial clamp tine can be highly variable. The angle created with off-axis syndesmotic clamping is likely a major culprit in iatrogenic malreduction. Sagittal plane malreduction appears to be highly sensitive to clamp obliquity, which is directly related to the medial clamp tine placement. Based on these data, we recommend placing the medial clamp tine in the anterior third of the tibial line on the lateral view to minimize malreduction risk. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
- 1 August 2017
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 31 (8) , 440-446
Medial Clamp Tine Positioning Affects Ankle Syndesmosis Malreduction
Objectives: To determine whether the position of the medial clamp tine during syndesmotic reduction affected reduction accuracy. Design: Prospective cohort. Setting: Urban Level 1 trauma center. Patients: Seventy-two patients with operatively treated syndesmotic injuries. Intervention: Patients underwent operative fixation of their ankle syndesmotic injuries using reduction forceps. The position of the medial clamp tine was then recorded with intraoperative fluoroscopy. Malreduction rates were then assessed with bilateral ankle computerized tomography. Main Outcome Measurement: Fibular position within the incisura was measured with respect to the uninjured side to determine whether a malreduction had occurred. Malreductions were then analyzed for associations with injury pattern, patient demographics, and the location of the medial clamp tine. Results: A statistically significant association was found between medial clamp position and sagittal plane syndesmosis malreduction. In reference to anterior fibular translation, there was a 0% malreduction rate in the 18 patients where the clamp tine was placed in the anterior third, a 19.4% malreduction rate in the middle third, and 60% malreduction rate in the posterior third (P = 0.006). In reference to posterior fibular translation, there was a 11.1% malreduction when clamp placement was in the anterior third, a 16.1% malreduction rate in the middle third, and 60% malreduction rate in the posterior third (P = 0.062). There were no significant associations between medial clamp position and coronal plane malreductions (overcompression or undercompression) (P = 1). Conclusions: When using reduction forceps for syndesmotic reduction, the position of the medial clamp tine can be highly variable. The angle created with off-axis syndesmotic clamping is likely a major culprit in iatrogenic malreduction. Sagittal plane malreduction appears to be highly sensitive to clamp obliquity, which is directly related to the medial clamp tine placement. Based on these data, we recommend placing the medial clamp tine in the anterior third of the tibial line on the lateral view to minimize malreduction risk. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.
- Open Access
- 1 June 2017
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 31 (6) , 339-344
Open Tibia Shaft Fractures and Soft-Tissue Coverage: The Effects of Management by an Orthopaedic Microsurgical Team
Objectives: To compare the timing of soft-tissue (flap) coverage and occurrence of complications before and after the establishment of an integrated orthopaedic trauma/microsurgical team. Design: Retrospective cohort study. Setting: A single level 1 trauma center. Patients: Twenty-eight subjects (13 pre- and 15 post-integration) with open tibia shaft fractures (OTA/AO 42A, 42B, and 42C) treated with flap coverage between January 2009 and March 2015. Intervention: Flap coverage for open tibia shaft fractures treated before (“preintegration”) and after (“postintegration”) implementation of an integrated orthopaedic trauma/microsurgical team. Main Outcome Measure: Time from index injury to flap coverage. Results: The unadjusted median time to coverage was 7 days (95% confidence interval, 5.9–8.1) preintegration, and 6 days (95% confidence interval, 4.6–7.4) postintegration (P = 0.48). For preintegration, 9 (69%) of the patients experienced complications, compared with 7 (47%) postintegration (P = 0.23). Conclusions: After formation of an integrated orthopaedic trauma/microsurgery team, we observed a 1-day decrease in median days to coverage from index injury. Complications overall were lowered in the postintegration group, although statistically insignificant. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 June 2017
- Published by Wolters Kluwer Health in Journal of Orthopaedic Trauma
- Vol. 31 (6) , 339-344
Open AccessOpen Tibia Shaft Fractures and Soft-Tissue Coverage: The Effects of Management by an Orthopaedic Microsurgical Team
Objectives: To compare the timing of soft-tissue (flap) coverage and occurrence of complications before and after the establishment of an integrated orthopaedic trauma/microsurgical team. Design: Retrospective cohort study. Setting: A single level 1 trauma center. Patients: Twenty-eight subjects (13 pre- and 15 post-integration) with open tibia shaft fractures (OTA/AO 42A, 42B, and 42C) treated with flap coverage between January 2009 and March 2015. Intervention: Flap coverage for open tibia shaft fractures treated before (“preintegration”) and after (“postintegration”) implementation of an integrated orthopaedic trauma/microsurgical team. Main Outcome Measure: Time from index injury to flap coverage. Results: The unadjusted median time to coverage was 7 days (95% confidence interval, 5.9–8.1) preintegration, and 6 days (95% confidence interval, 4.6–7.4) postintegration (P = 0.48). For preintegration, 9 (69%) of the patients experienced complications, compared with 7 (47%) postintegration (P = 0.23). Conclusions: After formation of an integrated orthopaedic trauma/microsurgery team, we observed a 1-day decrease in median days to coverage from index injury. Complications overall were lowered in the postintegration group, although statistically insignificant. Level of Evidence: Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.