Florence Edwards-Lévy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Florence Edwards-Lévy has a total of 118 co-authors. Here are the top co-authors by number of shared publications:
- Clément de Loubens
Université Grenoble Alpes
4 shared publications - Julien Deschamps
Aix Marseille University CNRS Centrale Marseille IRPHE Marseille France
4 shared publications M.-C. Lévy
Laboratoire de Pharmacotechnie, UMR/CNRS 6013, Faculté de Pharmacie, 51 rue Cognacq-Jay, 51096 Reims Cédex, France
4 shared publications- Marc Leonetti
I.R.P.H.E., Aix-Marseille Université, CNRS, Technopôle de Château-Gombert, F-13384, Marseille Cedex 13, France
4 shared publications Christian Thuillez
3 shared publicationsDominique Laurent-Maquin
INSERM U926, Université de Reims-Champagne Ardenne, Faculté d’Odontologie, 51 rue Cognacq-Jay, 51100 Reims, France
3 shared publications
Latest Publications
- 17 July 2017
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 48 (1) , 68-74
Deformability- and size-based microcapsule sorting
Biomedical applications often require to sort cells according to their physical properties, such as size, density or deformability. In recent years, microfluidics has provided a variety of tools to sort micro-objects. We present here a simple microfluidic device consisting of a channel containing a semi-cylindrical obstacle against which capsules are squeezed by the flow, followed by a diverging chamber where streamlines separate. We demonstrate that this basic system is capable of sorting elastic microcapsules according to their size at low flow strength, and according to the stiffness of their membrane at high flow strength. Contrary to most existing sorting devices, we show that the present one is very sensitive and capable of discriminating between capsules with differences in membrane elasticity of order unity.
- 17 July 2017
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 48 (1) , 68-74
Deformability- and size-based microcapsule sorting
Biomedical applications often require to sort cells according to their physical properties, such as size, density or deformability. In recent years, microfluidics has provided a variety of tools to sort micro-objects. We present here a simple microfluidic device consisting of a channel containing a semi-cylindrical obstacle against which capsules are squeezed by the flow, followed by a diverging chamber where streamlines separate. We demonstrate that this basic system is capable of sorting elastic microcapsules according to their size at low flow strength, and according to the stiffness of their membrane at high flow strength. Contrary to most existing sorting devices, we show that the present one is very sensitive and capable of discriminating between capsules with differences in membrane elasticity of order unity.
- 17 March 2017
- Published by IOP Publishing in Fluid Dynamics Research
- Vol. 49 (3) , 035501
Perturbations of the flow induced by a microcapsule in a capillary tube
Soft microcapsules moving in a cylindrical capillary deform from quasi-spherical shapes to elongated shapes with an inversion of curvature at the rear. We investigated the perturbation of the flow by particle tracking velocimetry around deformed microcapsules in confined flow. These experiments are completed by numerical simulations. Microcapsules are made of a thin membrane of polymerized human albumin and their shear elastic moduli are previously characterized in a cross flow chamber. Firstly, the velocity of the microcapsule can be calculated by theoretical predictions for rigid spheres, even for large deformations as 'parachute-like' shapes, if a relevant definition of the ratio of confinement is chosen. Secondly, at the rear and the front of the microcapsule, the existence of multiple recirculation regions is governed by the local curvature of the membrane. The amplitudes of these perturbations increase with the microcapsule deformation, whereas their axial extents are comparable to the radius of the capillary whatever the confinement and the capillary number. We conclude that whereas the motion of microcapsules in confined flow has quantitative similitudes with rigid spheres in terms of velocity and axial extent of the perturbation, their presence induces variations in the flow field that are related to the local deformation of the membrane as in droplets.
- 17 March 2017
- Published by IOP Publishing in Fluid Dynamics Research
- Vol. 49 (3) , 035501
Perturbations of the flow induced by a microcapsule in a capillary tube
Soft microcapsules moving in a cylindrical capillary deform from quasi-spherical shapes to elongated shapes with an inversion of curvature at the rear. We investigated the perturbation of the flow by particle tracking velocimetry around deformed microcapsules in confined flow. These experiments are completed by numerical simulations. Microcapsules are made of a thin membrane of polymerized human albumin and their shear elastic moduli are previously characterized in a cross flow chamber. Firstly, the velocity of the microcapsule can be calculated by theoretical predictions for rigid spheres, even for large deformations as 'parachute-like' shapes, if a relevant definition of the ratio of confinement is chosen. Secondly, at the rear and the front of the microcapsule, the existence of multiple recirculation regions is governed by the local curvature of the membrane. The amplitudes of these perturbations increase with the microcapsule deformation, whereas their axial extents are comparable to the radius of the capillary whatever the confinement and the capillary number. We conclude that whereas the motion of microcapsules in confined flow has quantitative similitudes with rigid spheres in terms of velocity and axial extent of the perturbation, their presence induces variations in the flow field that are related to the local deformation of the membrane as in droplets.
- 1 February 2017
- Published by Elsevier in Carbohydrate Polymers
- Vol. 157, 275-281
Influence of chemically modified alginate esters on the preparation of microparticles by transacylation with protein in W/O emulsions
- 1 February 2017
- Published by Elsevier in Carbohydrate Polymers
- Vol. 157, 275-281
Influence of chemically modified alginate esters on the preparation of microparticles by transacylation with protein in W/O emulsions
- 10 June 2016
- Published by Springer Nature in Colloid and Polymer Science
- Vol. 294 (8) , 1381-1389
Characterization of the mechanical properties of cross-linked serum albumin microcapsules: effect of size and protein concentration
- 10 June 2016
- Published by Springer Nature in Colloid and Polymer Science
- Vol. 294 (8) , 1381-1389
Characterization of the mechanical properties of cross-linked serum albumin microcapsules: effect of size and protein concentration
- Top Cited Papers
- 12 April 2016
- Published by Wolters Kluwer Health in Circulation
- Vol. 133 (15) , 1484-1497
Selective Stimulation of Cardiac Lymphangiogenesis Reduces Myocardial Edema and Fibrosis Leading to Improved Cardiac Function Following Myocardial Infarction
Background—: The lymphatic system regulates interstitial tissue fluid balance, and lymphatic malfunction causes edema. The heart has an extensive lymphatic network displaying a dynamic range of lymph flow in physiology. Myocardial edema occurs in many cardiovascular diseases, eg, myocardial infarction (MI) and chronic heart failure, suggesting that cardiac lymphatic transport may be insufficient in pathology. Here, we investigate in rats the impact of MI and subsequent chronic heart failure on the cardiac lymphatic network. Further, we evaluate for the first time the functional effects of selective therapeutic stimulation of cardiac lymphangiogenesis post-MI. Methods and Results—: We investigated cardiac lymphatic structure and function in rats with MI induced by either temporary occlusion (n=160) or permanent ligation (n=100) of the left coronary artery. Although MI induced robust, intramyocardial capillary lymphangiogenesis, adverse remodeling of epicardial precollector and collector lymphatics occurred, leading to reduced cardiac lymphatic transport capacity. Consequently, myocardial edema persisted for several months post-MI, extending from the infarct to noninfarcted myocardium. Intramyocardial-targeted delivery of the vascular endothelial growth factor receptor 3–selective designer protein VEGF-C C152S , using albumin-alginate microparticles, accelerated cardiac lymphangiogenesis in a dose-dependent manner and limited precollector remodeling post-MI. As a result, myocardial fluid balance was improved, and cardiac inflammation, fibrosis, and dysfunction were attenuated. Conclusions—: We show that, despite the endogenous cardiac lymphangiogenic response post-MI, the remodeling and dysfunction of collecting ducts contribute to the development of chronic myocardial edema and inflammation-aggravating cardiac fibrosis and dysfunction. Moreover, our data reveal that therapeutic lymphangiogenesis may be a promising new approach for the treatment of cardiovascular diseases.
- 12 April 2016
- Published by Wolters Kluwer Health in Circulation
- Vol. 133 (15) , 1484-1497
Top Cited PapersSelective Stimulation of Cardiac Lymphangiogenesis Reduces Myocardial Edema and Fibrosis Leading to Improved Cardiac Function Following Myocardial Infarction
Background—: The lymphatic system regulates interstitial tissue fluid balance, and lymphatic malfunction causes edema. The heart has an extensive lymphatic network displaying a dynamic range of lymph flow in physiology. Myocardial edema occurs in many cardiovascular diseases, eg, myocardial infarction (MI) and chronic heart failure, suggesting that cardiac lymphatic transport may be insufficient in pathology. Here, we investigate in rats the impact of MI and subsequent chronic heart failure on the cardiac lymphatic network. Further, we evaluate for the first time the functional effects of selective therapeutic stimulation of cardiac lymphangiogenesis post-MI. Methods and Results—: We investigated cardiac lymphatic structure and function in rats with MI induced by either temporary occlusion (n=160) or permanent ligation (n=100) of the left coronary artery. Although MI induced robust, intramyocardial capillary lymphangiogenesis, adverse remodeling of epicardial precollector and collector lymphatics occurred, leading to reduced cardiac lymphatic transport capacity. Consequently, myocardial edema persisted for several months post-MI, extending from the infarct to noninfarcted myocardium. Intramyocardial-targeted delivery of the vascular endothelial growth factor receptor 3–selective designer protein VEGF-C C152S , using albumin-alginate microparticles, accelerated cardiac lymphangiogenesis in a dose-dependent manner and limited precollector remodeling post-MI. As a result, myocardial fluid balance was improved, and cardiac inflammation, fibrosis, and dysfunction were attenuated. Conclusions—: We show that, despite the endogenous cardiac lymphangiogenic response post-MI, the remodeling and dysfunction of collecting ducts contribute to the development of chronic myocardial edema and inflammation-aggravating cardiac fibrosis and dysfunction. Moreover, our data reveal that therapeutic lymphangiogenesis may be a promising new approach for the treatment of cardiovascular diseases.
- 26 January 2016
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 789, 750-767
Tank-treading of microcapsules in shear flow
We investigated experimentally the deformation of soft microcapsules and the dynamics of their membrane in simple shear flows. Firstly, the tank-treading motion, i.e. the rotation of the membrane, was visualized and quantified by tracking particles included in the membrane by a new protocol. The period of membrane rotation increased quadratically with the extension of the long axis. The tracking of the distance between two close microparticles showed membrane contraction at the tips and stretching on the sides, a specific property of soft particles such as capsules. The present experimental results are discussed in regard to previous numerical simulations. This analysis showed that the variation of the tank-treading period with the Taylor parameter (deformation) cannot be explained by purely elastic membrane models. It suggests a strong effect of membrane viscosity whose order of magnitude is determined. Secondly, two distinct shapes of sheared microcapsules were observed. For moderate deformations, the shape was a steady ellipsoid in the shear plane. For larger deformations, the capsule became asymmetric and presented an S-like shape. When the viscous shear stress increased by three orders of magnitude, the short axis decreased by 70 % whereas the long axis increased by 100 % before any break-up. The inclination angle decreased from 40° to 8°, almost aligned with the flow direction as expected by theory and numerics on capsules and from experiments, theory and numerics on drops and vesicles. Whatever the microcapsule size and the concentration of proteins, the characteristic lengths of the shape, the Taylor parameter and the inclination angle satisfy master curves versus the long axis or the normalized shear stress or the capillary number in agreement with theory for non-negligible membrane viscosity in the regime of moderate deformations. Finally, we observed that very small deviation from sphericity gave rise to swinging motion, i.e. shape oscillations, in the small-deformation regime. In conclusion, this study of tank-treading motion supports the role of membrane viscosity on the dynamics of microcapsules in shear flow by independent methods that compare experimental data both with numerical results in the regime of large deformations and with theory in the regime of moderate deformations.
- 26 January 2016
- Published by Cambridge University Press (CUP) in Journal of Fluid Mechanics
- Vol. 789, 750-767
Tank-treading of microcapsules in shear flow
We investigated experimentally the deformation of soft microcapsules and the dynamics of their membrane in simple shear flows. Firstly, the tank-treading motion, i.e. the rotation of the membrane, was visualized and quantified by tracking particles included in the membrane by a new protocol. The period of membrane rotation increased quadratically with the extension of the long axis. The tracking of the distance between two close microparticles showed membrane contraction at the tips and stretching on the sides, a specific property of soft particles such as capsules. The present experimental results are discussed in regard to previous numerical simulations. This analysis showed that the variation of the tank-treading period with the Taylor parameter (deformation) cannot be explained by purely elastic membrane models. It suggests a strong effect of membrane viscosity whose order of magnitude is determined. Secondly, two distinct shapes of sheared microcapsules were observed. For moderate deformations, the shape was a steady ellipsoid in the shear plane. For larger deformations, the capsule became asymmetric and presented an S-like shape. When the viscous shear stress increased by three orders of magnitude, the short axis decreased by 70 % whereas the long axis increased by 100 % before any break-up. The inclination angle decreased from 40° to 8°, almost aligned with the flow direction as expected by theory and numerics on capsules and from experiments, theory and numerics on drops and vesicles. Whatever the microcapsule size and the concentration of proteins, the characteristic lengths of the shape, the Taylor parameter and the inclination angle satisfy master curves versus the long axis or the normalized shear stress or the capillary number in agreement with theory for non-negligible membrane viscosity in the regime of moderate deformations. Finally, we observed that very small deviation from sphericity gave rise to swinging motion, i.e. shape oscillations, in the small-deformation regime. In conclusion, this study of tank-treading motion supports the role of membrane viscosity on the dynamics of microcapsules in shear flow by independent methods that compare experimental data both with numerical results in the regime of large deformations and with theory in the regime of moderate deformations.
- 8 July 2015
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 16 (8) , 2296-2307
Serum Albumin-Alginate Microparticles Prepared by Transacylation: Relationship between Physicochemical, Structural and Functional Properties
Our laboratory develops a method of microencapsulation using a transacylation reaction in a water-in-oil (W/O) emulsion. The method is based on the creation of amide bonds between free amine functions of a protein (human serum albumin (HSA)) and ester groups of propylene glycol alginate (PGA) in the inner aqueous phase after alkalization. The aim of this work is to study the influence of physicochemical properties of HSA–PGA mixtures on microparticle characteristics. Microparticles were prepared varying the concentrations of PGA and HSA, then characterized (inner structure, size, swelling rate, release kinetics). PGA and each polymer mixture used in the microencapsulation procedure were examined in order to elucidate the mechanism of microstructure formation. It was found that the morphology and functional properties of HSA–alginate microparticles were related to the two polymer concentrations in the aqueous solution. Actually, the polymer concentration variations led to physicochemical changes, which affected the microparticle structure and functional properties.
- 8 July 2015
- Published by American Chemical Society (ACS) in Biomacromolecules
- Vol. 16 (8) , 2296-2307
Serum Albumin-Alginate Microparticles Prepared by Transacylation: Relationship between Physicochemical, Structural and Functional Properties
Our laboratory develops a method of microencapsulation using a transacylation reaction in a water-in-oil (W/O) emulsion. The method is based on the creation of amide bonds between free amine functions of a protein (human serum albumin (HSA)) and ester groups of propylene glycol alginate (PGA) in the inner aqueous phase after alkalization. The aim of this work is to study the influence of physicochemical properties of HSA–PGA mixtures on microparticle characteristics. Microparticles were prepared varying the concentrations of PGA and HSA, then characterized (inner structure, size, swelling rate, release kinetics). PGA and each polymer mixture used in the microencapsulation procedure were examined in order to elucidate the mechanism of microstructure formation. It was found that the morphology and functional properties of HSA–alginate microparticles were related to the two polymer concentrations in the aqueous solution. Actually, the polymer concentration variations led to physicochemical changes, which affected the microparticle structure and functional properties.
- 1 April 2015
- Published by Elsevier in Neuroscience
- Vol. 290, 445-453
Chronic delivery of α-melanocyte-stimulating hormone in rat hypothalamus using albumin-alginate microparticles: Effects on food intake and body weight
- 1 April 2015
- Published by Elsevier in Neuroscience
- Vol. 290, 445-453
Chronic delivery of α-melanocyte-stimulating hormone in rat hypothalamus using albumin-alginate microparticles: Effects on food intake and body weight
- 24 December 2014
- Published by Springer Nature in Angiogenesis
- Vol. 18 (2) , 191-200
Role of M2-like macrophage recruitment during angiogenic growth factor therapy
Therapeutic angiogenesis has yet to fulfill its promise for the clinical treatment of ischemic diseases. Given the impact of macrophages during pathophysiological angiogenesis, we asked whether macrophages may similarly modulate vascular responses to targeted angiogenic therapies. Mouse matrigel plug assay and rat myocardial infarction (MI) model were used to assess angiogenic therapy with either VEGF-A or FGF-2 with HGF (F+H) delivered locally via albumin–alginate microcapsules. The infiltration of classical M1-type and alternative M2-like macrophages was assessed. Clodronate was used to prevent macrophage recruitment, and the VEGFR2 blocking antibody, DC101, to prevent VEGF-A signaling. At 3 weeks after matrigel implantation, the combination therapy (F+H) led to increased total, and specifically M2-like, macrophage infiltration versus control and VEGF-A plugs, correlating with the angiogenic response. In contrast, VEGF-A preferential recruited M1-type macrophages. In agreement with a direct role of M2-like macrophages in F+H-induced vessel growth, clodronate radically decreased angiogenesis. Further, DC101 reduced F+H-induced angiogenesis, without altering macrophage infiltration, revealing macrophage-derived VEGF-A as a crucial determinant of tissue responsiveness. Similarly, increased cardiac M2-like macrophage infiltration was found following F+H therapy post-MI, with strong correlation between macrophage levels and angiogenic and arteriogenic responses. In conclusion, M2-like macrophages play a decisive role, linked to VEGF-A production, in regulation of tissue responsiveness to angiogenic therapies including the combination of F+H. Our data suggest that future attempts at therapeutic revascularization in ischemic patients might benefit from coupling targeted growth factor delivery with either direct or indirect approaches to recruit pro-angiogenic macrophages in order to maximize therapeutic angiogenic/arteriogenic responses.
- 24 December 2014
- Published by Springer Nature in Angiogenesis
- Vol. 18 (2) , 191-200
Role of M2-like macrophage recruitment during angiogenic growth factor therapy
Therapeutic angiogenesis has yet to fulfill its promise for the clinical treatment of ischemic diseases. Given the impact of macrophages during pathophysiological angiogenesis, we asked whether macrophages may similarly modulate vascular responses to targeted angiogenic therapies. Mouse matrigel plug assay and rat myocardial infarction (MI) model were used to assess angiogenic therapy with either VEGF-A or FGF-2 with HGF (F+H) delivered locally via albumin–alginate microcapsules. The infiltration of classical M1-type and alternative M2-like macrophages was assessed. Clodronate was used to prevent macrophage recruitment, and the VEGFR2 blocking antibody, DC101, to prevent VEGF-A signaling. At 3 weeks after matrigel implantation, the combination therapy (F+H) led to increased total, and specifically M2-like, macrophage infiltration versus control and VEGF-A plugs, correlating with the angiogenic response. In contrast, VEGF-A preferential recruited M1-type macrophages. In agreement with a direct role of M2-like macrophages in F+H-induced vessel growth, clodronate radically decreased angiogenesis. Further, DC101 reduced F+H-induced angiogenesis, without altering macrophage infiltration, revealing macrophage-derived VEGF-A as a crucial determinant of tissue responsiveness. Similarly, increased cardiac M2-like macrophage infiltration was found following F+H therapy post-MI, with strong correlation between macrophage levels and angiogenic and arteriogenic responses. In conclusion, M2-like macrophages play a decisive role, linked to VEGF-A production, in regulation of tissue responsiveness to angiogenic therapies including the combination of F+H. Our data suggest that future attempts at therapeutic revascularization in ischemic patients might benefit from coupling targeted growth factor delivery with either direct or indirect approaches to recruit pro-angiogenic macrophages in order to maximize therapeutic angiogenic/arteriogenic responses.
- 12 May 2014
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 10 (25) , 4561-4568
Mechanical characterization of cross-linked serum albumin microcapsules
Controlling the deformation of microcapsules and capsules is essential in numerous biomedical applications. The mechanical properties of the membrane of microcapsules made of cross-linked human serum albumin (HSA) are revealed by two complementary experiments in the linear elastic regime. The first provides the surfacic shear elastic modulus Gs by the study of small deformations of a single capsule trapped in an elongational flow: Gs varies from 0.002 to 5 N m−1. The second gives the volumic Young's modulus E of the membrane by shallow and local indentations of the membrane with an AFM probe: E varies from 20 kPa to 1 MPa. The surfacic and volumic elastic moduli increase with the size of the capsule up to three orders of magnitude and with the protein concentration of the membrane. The membrane thickness is evaluated from these two membrane mechanical characteristics and increases with the size and the initial HSA concentration from 2 to 20 μm.
- 12 May 2014
- Published by Royal Society of Chemistry (RSC) in Soft Matter
- Vol. 10 (25) , 4561-4568
Mechanical characterization of cross-linked serum albumin microcapsules
Controlling the deformation of microcapsules and capsules is essential in numerous biomedical applications. The mechanical properties of the membrane of microcapsules made of cross-linked human serum albumin (HSA) are revealed by two complementary experiments in the linear elastic regime. The first provides the surfacic shear elastic modulus Gs by the study of small deformations of a single capsule trapped in an elongational flow: Gs varies from 0.002 to 5 N m−1. The second gives the volumic Young's modulus E of the membrane by shallow and local indentations of the membrane with an AFM probe: E varies from 20 kPa to 1 MPa. The surfacic and volumic elastic moduli increase with the size of the capsule up to three orders of magnitude and with the protein concentration of the membrane. The membrane thickness is evaluated from these two membrane mechanical characteristics and increases with the size and the initial HSA concentration from 2 to 20 μm.