TVTuomas Virén

Tuomas Virén

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Tuomas Virén has a total of 78 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Variability in Breast Radiotherapy Treatment Plan Evaluation: A Multi-Institutional Study of Expert Agreement and Decision-Making  

    by Hiran Maladenige, Janne Heikkilä, Jan Seppälä, Tuomas Virén, Juuso T. J. Honkanen, Akseli Leino, Karoliina Hundlinger, Tero Vatanen, Laura Tuomikoski, Tiina Seppälä, et al.

    Objective: To quantify inter- and intra-rater variability in comparative breast radiotherapy treatment plan evaluation and determine how individual evaluation criteria contribute to overall plan selection. Approach: Nine medical physicists from four radiotherapy centres independently evaluated paired treatment plans (original and systematically modified plans) for 21 left-sided breast cancer patients treated with tangential volumetric modulated arc therapy. Plans were evaluated using target- and organ-at-risk-related criteria in two blinded rounds. Inter- and intra-rater agreement were assessed using Fleiss' and Cohen's kappa, respectively. A mixed-effects logistic regression model was used to quantify the influence of individual evaluation criteria on the final verdict. Main results: Inter-rater agreement varied across evaluation criteria. Organ-specific dose assessments showed high agreement (κ=0.74-0.94), whereas integrative criteria, including target dose homogeneity, overall organ-at-risk dose, control of low-dose spread, and the final verdict, showed lower agreement (κ=0.45-0.63). In contrast, intra-rater agreement remained high (mean κ=0.82), indicating consistent individual evaluation behaviour. Mixed-effects modelling identified a hierarchy of decision-making priorities. Overall organ-at-risk dose, target coverage, and ipsilateral lung dose had the greatest influence on final verdict (odds ratio: 10–16), whereas other criteria contributed less. Criteria with greater influence on decision-making generally showed higher inter-rater agreement. Significance: Radiotherapy plan evaluation is both variable and structured. Variability arises from differences in how evaluators prioritize competing dose-volume factors rather than from inconsistency in individual assessments. The relationship between criterion importance and observer agreement provides insight into clinical decision-making and establishes a reference framework for developing and validating objective treatment plan evaluation methods.

  • Open Access

    KaSARi: a national framework for standardized, automated, and predictive radiotherapy in Finland

    by Jan Seppälä, Maria Tengström, Henri Korkalainen, Tuomas Virén, Juuso Tj Honkanen, Juha Nikkinen, Kaisa Lehtiö, Annika Ålgars, Jani Keyriläinen, Sami Suilamo, et al.

    Background and purpose: National radiotherapy (RT) data infrastructures are emerging to support treatment quality assurance and outcome research. However, prospective nationwide integration of full DICOM-RT data with toxicity and patient-reported outcome measures (PROMs) remains uncommon. KaSARi (Key advances in Standardizing, Automating, and predicting Risks in RT) was established to create national research infrastructure for prospective RT data collection and integration in Finland.Materials and methods: KaSARi is a prospective, consent-based multicenter cohort infrastructure involving Finnish university and central hospitals. All adult patients receiving RT are eligible. DICOM-RT datasets from treatment planning and oncology information systems are linked to clinician-graded toxicity, PROMs and relevant clinical variables. The infrastructure builds on previously validated multi-institutional DICOM workflows and follows FAIR (Findable, Accessible, Interoperable, Reusable) data principles. Predefined work packages support data harmonization, scalable data processing and enable downstream applications such as AI-based segmentation, dose prediction, and outcome modeling.Results: Patient recruitment started in May 2025. By February 2026, 221 patients had been enrolled at the coordinating center, initially including breast cancer patients and subsequently expanding to all RT indications. Recruitment at a second center began in November 2025, with 37 patients enrolled. The infrastructure is projected to include approximately 29,000 patients over 15 years. Integration of dosimetric, clinical and PROM data is progressing through a phased national implementation as additional centers join the network.Interpretation: KaSARi represents a national infrastructure prospectively integrating full DICOM-RT datasets with clinician-graded toxicity and PROMs across all RT indications within a unified research protocol. The study provides a foundation for nationwide outcome modeling, harmonization of RT practices and development and validation of data-driven AI-based methods.


  • Open Access

    Automated daily adaptation for breast cancer radiotherapy: benefits of deep learning-driven dose prediction workflow for CBCT-based adaptation

    by Nina Pesonen, Tuomas Virén, Mikko Mankinen, Akseli Leino, Janne Heikkilä, Hiran Cg Maladenige, Jan Seppälä, Henri Korkalainen

    Objective. Daily anatomical variations can jeopardize the quality of modern radiotherapy. Adaptive radiotherapy (ART) aims to address this by adjusting treatment plans according to the patient’s daily anatomy. However, as implementation of ART is currently time-consuming, laborious, and expensive, its routine clinical use remains limited. In this study, we investigate the feasibility of using deep learning (DL)-based dose prediction with automated treatment planning and daily cone-beam CTs (CBCTs) to evaluate the clinical benefits of daily replanning in breast cancer RT. Approach. Dataset of 28 breast cancer patients treated with Volumetric Modulated Arc Therapy and their daily CBCTs ( n = 15) were used to evaluate the dosimetric impact of daily anatomical variations. In-house developed DL-based dose prediction engine and automated planning solution were used to create dose accumulated and adaptive plans to determine the potential benefits of daily replanning. Main results. Adaptation improved the planning target volume (PTV) dose coverage in 25 of 28 patients and increased the fractions achieving the clinical goal (PTV V 38.05 Gy > 95%) from 35% to 93%. Moreover, ipsilateral lung V 1 6 Gy , heart V 4 Gy , and contralateral lung V 2 .5 Gy decreased by 0.4 pp, 0.6 pp, and 0.2 pp, respectively. Using an adaptation criterion based on DL prediction, approximately 25% of fractions were identified for replanning, resulting in a 1.2 pp increase in PTV V 3 8.05 Gy and reduced organs at risk (OAR) doses. Significance. This study demonstrated the feasibility of a CBCT-based automated workflow for breast cancer ART that combines DL-driven dose prediction with automated planning. The approach showed the benefit of replanning each fraction, improved PTV coverage, and offered potential OAR sparing, while also highlighting that daily adaptation may not benefit all patients on all fractions. With appropriately defined thresholds, the workflow can function as a decision-support tool, providing a practical framework to guide adaptive decision-making and optimize the use of clinical resources.


  • Open Access

    A comprehensive dose-volume histogram-based index for radiotherapy treatment plan quality evaluation: application to breast cancer radiotherapy

    by Hiran Cg Maladenige, Jan Seppälä, Tuomas Virén, Juuso Tj Honkanen, Janne Heikkilä, Akseli Leino, Henri Korkalainen

    Advances in radiotherapy have increased treatment plan complexity, making manual quality evaluation more subjective and variable. While deep learning approaches offer automation in planning, evaluation remains a manual bottleneck. Existing indices evaluate individual aspects in isolation and lack a unified perspective. To address this, we developed the advanced dose distribution index (ADDI), a comprehensive dose-volume histogram- and biological dose response-based metric for automation-friendly quality evaluation. ADDI summarizes treatment plan quality as a polar vector, ADDI( r , θ ), where the magnitude ( r ) reflects overall quality and the angle ( θ ) captures the balance between target and organ-at-risk dose. We validated ADDI across four breast cancer groups involving whole-breast irradiation with and without regional nodal irradiation for both lateralities, comprising 778 patients. ADDI demonstrated significant differences between groups, with left-sided and node-inclusive treatments having worse scores (i.e. higher dose exposure) than right-sided and node-exclusive cases. Additionally, ADDI responded to anatomical features such as planning target volume size, cardiothoracic ratio, central lung distance, and maximal heart distance, highlighting its sensitivity to patient-specific anatomical factors. These results indicate that ADDI effectively captures clinically meaningful variations in dose distribution and provides a unified, objective tool that is compatible with both automated and manual treatment planning workflows.

  • Open Access

    The benefit of DIBH on irradiated lung volume is overestimated in right-sided breast cancer VMAT with node involvement

    by Mikko Mankinen, Tuomas Virén, Jan Seppälä, Kristiina Vuolukka, Kimmo Myllyoja, Janne Heikkilä, Tuomas Koivumäki


  • 50 Hz magnetic field influences caspase-3 activity and cell cycle distribution in ionizing radiation exposed SH-SY5Y neuroblastoma cells

    by Valtteri Nieminen, Maria-Viola Martikainen, Saija Kalliomäki, Tuomas Virén, Jan Seppälä, Jukka Juutilainen, Jonne Naarala, Jukka Luukkonen

    PurposeEarlier evidence suggests that extremely low frequency magnetic fields (ELF MFs) can modify the effects of carcinogenic agents. However, the studies conducted so far with ionizing radiation as the co-exposure agent are sparse and have provided inconclusive results. We investigated whether 50 Hz MFs alone, or in combination with ionizing radiation alter cell biological variables relevant to cancer and the biological effects of ionizing radiation.Materials and methodsHuman SH-SY5Y neuroblastoma cells were sham exposed or exposed to 100 or 500 mu T MF for 24 h either before or after ionizing radiation exposure (0, 0.4 or 2 Gy). After the exposures, cells were assayed for viability, clonogenicity, reactive oxygen species, caspase-3 activity, and cell cycle distribution. Cell cycle distribution was assayed with propidium iodide staining followed by flow cytometry analysis and ROS levels were assayed together with cell viability by double staining with DeepRed and Sytox Blue followed by flow cytometry analysis.ResultsIncreased caspase-3 activity was observed in cells exposed to 500 mu T MF before or after ionizing radiation. Furthermore, exposure to the 500 mu T MF after the ionizing radiation decreased the percentage of cells in S-phase. No changes in the ROS levels, clonogenicity, or viability of the cells were observed in the MF exposed groups compared to the corresponding sham exposed groups, and no MF effects were observed in cells exposed at 100 mu T.ConclusionsOnly the 500 mu T magnetic flux density affected SH-SY5Y cells significantly. The effects were small but may nevertheless help to understand how MFs modify the effects of ionizing radiation. The increase in caspase-3 activity may not reflect effects on apoptosis, as no changes were observed in the subG1 phase of the cell cycle. In contrast to some earlier findings, 50 Hz MF exposure after ionizing radiation was not less effective than MF treatment given prior to ionizing radiation.

  • Quantitative Dual Contrast CT Technique for Evaluation of Articular Cartilage Properties

    by Abhisek Bhattarai, Juuso T. J. Honkanen, Katariina A. H. Myller, Mithilesh Prakash, Miitu Korhonen, Annina E. A. Saukko, Tuomas Virén, Antti Joukainen, Amit N. Patwa, Heikki Kröger, et al.

    Impact injuries of cartilage may initiate post-traumatic degeneration, making early detection of injury imperative for timely surgical or pharmaceutical interventions. Cationic (positively-charged) CT contrast agents detect loss of cartilage proteoglycans (PGs) more sensitively than anionic (negatively-charged) or non-ionic (non-charged, i.e., electrically neutral) agents. However, degeneration related loss of PGs and increase in water content have opposite effects on the diffusion of the cationic agent, lowering its sensitivity. In contrast to cationic agents, diffusion of non-ionic agents is governed only by steric hindrance and water content of cartilage. We hypothesize that sensitivity of an iodine(I)-based cationic agent may be enhanced by simultaneous use of a non-ionic gadolinium(Gd)-based agent. We introduce a quantitative dual energy CT technique (QDECT) for simultaneous quantification of two contrast agents in cartilage. We employ this technique to improve the sensitivity of cationic CA4+ (q =+4) by normalizing its partition in cartilage with that of non-ionic gadoteridol. The technique was evaluated with measurements of contrast agent mixtures of known composition and human osteochondral samples (n = 57) after immersion (72 h) in mixture of CA4+ and gadoteridol. Samples were arthroscopically graded and biomechanically tested prior to QDECT (50/100 kV). QDECT determined contrast agent mixture compositions correlated with the true compositions (R2= 0.99, average error = 2.27%). Normalizing CA4+ partition in cartilage with that of gadoteridol improved correlation with equilibrium modulus (from ρ = 0.701 to 0.795). To conclude, QDECT enables simultaneous quantification of I and Gd contrast agents improving diagnosis of cartilage integrity and biomechanical status.


  • Accuracy and reliability of a hand‐held in vivo skin indentation device to assess skin elasticity

    by T. Virén, J. T. Iivarinen, J. K. Sarin, I. Harvima, H. N. Mayrovitz

    Objective: The aim of this study was to evaluate the performance of a hand‐held indentation device for fast and reliable determination of skin stiffness.Methods: Device accuracy to indentation depths of 0.6 and 1.3 mm was first evaluated on plastic foam materials with mechanical properties verified by a laboratory material testing device. Subsequently, the device's sensitivity to detect age‐related changes in skin stiffness was evaluated among 46 healthy women (18–79 years). Finally, the reproducibility of the method was tested with six healthy subjects.Results: High correlation was detected between indentation stiffness of reference material and Young's modulus determined with mechanical testing device (0.6 mm indenter: r = 0.97, P = 0.05; 1.3 mm indenter: r = 0.98, P = 0.04). Age‐related decrease of 38% in skin stiffness was observed in healthy volunteers (P < 0.05). The coefficient of variation for 0.6 and 1.3 mm indenters was 7.4% and 8.5%, respectively. No trend related to hysteresis effect was observed from repeated measurements.Conclusions: The presented indentation technique was accurate against the laboratory material testing device. Furthermore, skin changes related to ageing could be detected with the indentation technique. The new device was found to be feasible for monitoring skin stiffness in cosmetics and clinical conditions.


  • Open Access

    Ultrasound Arthroscopy of Hip in Treatment of Osteochondritis Dissecans

    by Antti Joukainen, Tuomas Virén, Pekko Penttilä, Jukka Liukkonen, Pia Henriikka Puhakka, Heikki Kröger, Juha Töyräs

    An ultrasound arthroscopy (UA) technique is a promising tool for the evaluation of the articular cartilage during arthroscopic examination. However, the applicability of UA for the evaluation of the hip joint is unknown. We describe a UA assessment of a patient with osteochondritis dissecans at the femoral head. An ultrasound catheter designed for intravascular imaging was inserted into the hip joint by use of conventional arthroscopic portals, and the cartilage surfaces of the femoral head and acetabulum were investigated with ultrasound. UA provided essential quantitative information on the integrity of the articular cartilage and the condition of the subchondral plate not assessable with conventional arthroscopy. Furthermore, the UA technique provided the possibility to monitor arthroscopy‐assisted retrograde drilling and bone transplantation in the hip joint. Technique Video: video See video under supplementary data.