Yasuyuki Matsuda
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yasuyuki Matsuda has a total of 467 co-authors. Here are the top co-authors by number of shared publications:
- Stefan Ulmer
Heinrich Heine University Düsseldorf
13 shared publications - Christian Smorra
Heinrich-Heine Universität Düsseldorf
10 shared publications - Klaus Blaum
Max-Planck-Institut für Kernphysik, Heidelberg, Germany
10 shared publications - Christian Ospelkaus
Institut für Quantenoptik, Leibniz Universität, Hannover, Germany
9 shared publications - Barbara Maria Latacz
CERN, Geneva, Switzerland
8 shared publications - Markus Fleck
RIKEN
8 shared publications
Latest Publications
- 1 July 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (7)
A 400-m polarization-maintaining optical fiber delivery system with a commercial wavelength meter for laser cooling of radioactive Fr
We developed a 400-m polarization-maintaining optical fiber delivery system for magneto-optical trapping of radioactive Fr atoms at RIKEN in Japan. The optical system is useful for the precise studies of the electron’s electric dipole moment and the parity nonconservation effect in atomic systems. The power saturation effect due to the stimulated Brillouin scattering in the fiber was investigated. Polarization fluctuation was optimized to be below 5 × 10−3. The absolute frequency of the stabilized laser was measured with an absolute accuracy of 1.5 MHz using a high-performance commercial wavelength meter. In addition, the absolute frequencies of hyperfine transitions of iodine molecules (127I2) near 718 nm were determined. We demonstrated laser cooling of Rb with 440-m optical fiber delivery.
- 1 July 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (7)
A 400-m polarization-maintaining optical fiber delivery system with a commercial wavelength meter for laser cooling of radioactive Fr
We developed a 400-m polarization-maintaining optical fiber delivery system for magneto-optical trapping of radioactive Fr atoms at RIKEN in Japan. The optical system is useful for the precise studies of the electron’s electric dipole moment and the parity nonconservation effect in atomic systems. The power saturation effect due to the stimulated Brillouin scattering in the fiber was investigated. Polarization fluctuation was optimized to be below 5 × 10−3. The absolute frequency of the stabilized laser was measured with an absolute accuracy of 1.5 MHz using a high-performance commercial wavelength meter. In addition, the absolute frequencies of hyperfine transitions of iodine molecules (127I2) near 718 nm were determined. We demonstrated laser cooling of Rb with 440-m optical fiber delivery.
- Open Access
- 1 March 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (3)
Optimizing antihydrogen production via slow plasma merging
We present advances in plasma control and diagnosis, leading to the production of exceptionally large quantities of neutral antimatter. We measure the time-dependent temperature and density distribution of antiprotons and positrons while slowly combining them to make antihydrogen atoms in a nested Penning–Malmberg trap. The total antihydrogen yield and the number of atoms escaping the trap as a beam are greatest when the positron temperature is lowest and when antiprotons enter the positron plasma at the smallest radius. We control these parameters by changing the rate at which we lower the electrostatic barrier between the antiproton and positron plasmas and by heating the positrons. With the optimal settings, we produce 2.3×106 antihydrogen atoms per 15-min run, surpassing the previous state of the art (3.1×104 atoms in 4 min) and the most recent advances in other experiments by factors of 20 and 5, respectively.
- 1 March 2026
- Published by AIP Publishing in Physics of Plasmas
- Vol. 33 (3)
Open AccessOptimizing antihydrogen production via slow plasma merging
We present advances in plasma control and diagnosis, leading to the production of exceptionally large quantities of neutral antimatter. We measure the time-dependent temperature and density distribution of antiprotons and positrons while slowly combining them to make antihydrogen atoms in a nested Penning–Malmberg trap. The total antihydrogen yield and the number of atoms escaping the trap as a beam are greatest when the positron temperature is lowest and when antiprotons enter the positron plasma at the smallest radius. We control these parameters by changing the rate at which we lower the electrostatic barrier between the antiproton and positron plasmas and by heating the positrons. With the optimal settings, we produce 2.3×106 antihydrogen atoms per 15-min run, surpassing the previous state of the art (3.1×104 atoms in 4 min) and the most recent advances in other experiments by factors of 20 and 5, respectively.
- Open Access
- 22 January 2026
- Published by Springer Nature in Research Square
Antiproton Trapping for 614 days
We report the trapping and continuous monitoring of a cloud of antiprotons (\pbar{}) for 614 days in the BASE reservoir trap at CERN, representing the longest confinement of antimatter achieved to date. The experiment is operated at an exceptionally low particle-loss rate of less than one antiproton per month, with intervals approaching up to five months without a single loss, and demonstrating one year of continuous experiment operation within which only three particles were consumed. This unprecedented stability establishes a new paradigm for high-precision studies of exotic and ultra-rare charged particles. Our approach is readily extendable to other species, including highly charged ions and prospective antimatter systems such as $\overline{\mathrm{H}}_2^-$, $\overline{\mathrm{H}}^+$, and $\overline{\mathrm{d}}$. By analyzing all BASE reservoir trap data collected since 2014, we set a five-fold improved lower bound on the directly constrained antiproton lifetime. Beyond its fundamental implications, this advance enables future transport and precision measurements on \pbar{} and other exotic ions in dedicated offline laboratories, opening new frontiers in antimatter research.- 22 January 2026
- Published by Springer Nature in Research Square
Open AccessAntiproton Trapping for 614 days
We report the trapping and continuous monitoring of a cloud of antiprotons (\pbar{}) for 614 days in the BASE reservoir trap at CERN, representing the longest confinement of antimatter achieved to date. The experiment is operated at an exceptionally low particle-loss rate of less than one antiproton per month, with intervals approaching up to five months without a single loss, and demonstrating one year of continuous experiment operation within which only three particles were consumed. This unprecedented stability establishes a new paradigm for high-precision studies of exotic and ultra-rare charged particles. Our approach is readily extendable to other species, including highly charged ions and prospective antimatter systems such as $\overline{\mathrm{H}}_2^-$, $\overline{\mathrm{H}}^+$, and $\overline{\mathrm{d}}$. By analyzing all BASE reservoir trap data collected since 2014, we set a five-fold improved lower bound on the directly constrained antiproton lifetime. Beyond its fundamental implications, this advance enables future transport and precision measurements on \pbar{} and other exotic ions in dedicated offline laboratories, opening new frontiers in antimatter research. - Open Access
- 23 July 2025
- Published by Springer Nature in Nature
- Vol. 644 (8075) , 1-5
Coherent spectroscopy with a single antiproton spin
Coherent quantum transition spectroscopy is a powerful tool in metrology1, quantum information processing2, magnetometry3 and precision tests of the standard model4. It was applied with great success in proton and deuteron magnetic moment measurements5, which culminated in maser spectroscopy with sub-parts-per-trillion resolution6 and many other experiments at the forefront of physics7. All of these experiments were performed on macroscopic ensembles of particles, whereas the coherent spectroscopy of a ‘free’ single nuclear spin has, to our knowledge, never been reported before. Here we demonstrate coherent quantum transition spectroscopy of the spin of a single antiproton stored in a cryogenic Penning-trap system. We apply a multi-trap technique8, detect the antiproton spin state using the continuous Stern–Gerlach effect9 and transport the particle to the homogeneous magnetic field of a precision trap (PT). Here we induce the coherent dynamics and analyse the result by quantum-projection measurements in the analysis trap (AT)10. We observe, for the first time, Rabi oscillations of an antiproton spin and achieve in time-series measurements spin-inversion probabilities greater than 80% at spin coherence times of about 50 s. Scans of single-particle spin resonances show inversions greater than 70%, at transition linewidths 16 times narrower than in previous measurements8, limited by cyclotron frequency measurement decoherence. This achievement marks a notable step towards at least tenfold improved tests of matter/antimatter symmetry using proton and antiproton magnetic moments.
- 23 July 2025
- Published by Springer Nature in Nature
- Vol. 644 (8075) , 1-5
Open AccessCoherent spectroscopy with a single antiproton spin
Coherent quantum transition spectroscopy is a powerful tool in metrology1, quantum information processing2, magnetometry3 and precision tests of the standard model4. It was applied with great success in proton and deuteron magnetic moment measurements5, which culminated in maser spectroscopy with sub-parts-per-trillion resolution6 and many other experiments at the forefront of physics7. All of these experiments were performed on macroscopic ensembles of particles, whereas the coherent spectroscopy of a ‘free’ single nuclear spin has, to our knowledge, never been reported before. Here we demonstrate coherent quantum transition spectroscopy of the spin of a single antiproton stored in a cryogenic Penning-trap system. We apply a multi-trap technique8, detect the antiproton spin state using the continuous Stern–Gerlach effect9 and transport the particle to the homogeneous magnetic field of a precision trap (PT). Here we induce the coherent dynamics and analyse the result by quantum-projection measurements in the analysis trap (AT)10. We observe, for the first time, Rabi oscillations of an antiproton spin and achieve in time-series measurements spin-inversion probabilities greater than 80% at spin coherence times of about 50 s. Scans of single-particle spin resonances show inversions greater than 70%, at transition linewidths 16 times narrower than in previous measurements8, limited by cyclotron frequency measurement decoherence. This achievement marks a notable step towards at least tenfold improved tests of matter/antimatter symmetry using proton and antiproton magnetic moments.
- Open Access
- 20 March 2025
- Published by Springer Nature in Research Square
Coherent Spectroscopy with a Single Antiproton Spin
Coherent quantum transition spectroscopy is a powerful tool in quantum-sensing and metrology (1), quantum information processing (2), accurate magnetometry (3), high-precision tests of the fundamental laws of nature, and searches for physics beyond the Standard Model (4). In atomic physics measurements, it was applied with great success in proton and deuteron magnetic moment measurements (5), which culminated for example in MASER spectroscopy with sub-parts per trillion resolution (6), in record-constraints on the neutron electric dipole moment (7), and many other experiments at the forefront of physics. All these experiments were performed on macroscopic ensembles of particles, while the coherent spectroscopy of a “quasifree” single nuclear spin has never been reported before. In this manuscript, we demonstrate the first non-destructive coherent quantum transition spectroscopy of the spin of a single trapped antiproton, stored in a cryogenic Penning-trap system. We apply a multi-trap technique (8), detect the antiproton spin-state using the continuous Stern-Gerlach-effect (9), and transport the particle to the homogeneous and stabilized magnetic field of a precision trap (PT). Here, we induce the coherent dynamics, and analyze the result by a quantum-projection measurement in the analysis trap (10). In our measurements, we observe for the first time Rabi-oscillations of a single nuclear magnetic moment, and achieve in time series measurements spin inversion probabilities above 80% at spin coherence times of ≈ 50s. Scans of single-particle spin resonance spectra show inversions > 70%, at transition line-widths 16 times narrower than in our previous measurements (8), limited by cyclotron frequency measurement decoherence. This achievement marks a major step towards at least 10-fold improved measurements of the proton and antiproton magnetic moments, and thus, substantially improved tests of matter/antimatter symmetry in the baryon-sector.
- 20 March 2025
- Published by Springer Nature in Research Square
Open AccessCoherent Spectroscopy with a Single Antiproton Spin
Coherent quantum transition spectroscopy is a powerful tool in quantum-sensing and metrology (1), quantum information processing (2), accurate magnetometry (3), high-precision tests of the fundamental laws of nature, and searches for physics beyond the Standard Model (4). In atomic physics measurements, it was applied with great success in proton and deuteron magnetic moment measurements (5), which culminated for example in MASER spectroscopy with sub-parts per trillion resolution (6), in record-constraints on the neutron electric dipole moment (7), and many other experiments at the forefront of physics. All these experiments were performed on macroscopic ensembles of particles, while the coherent spectroscopy of a “quasifree” single nuclear spin has never been reported before. In this manuscript, we demonstrate the first non-destructive coherent quantum transition spectroscopy of the spin of a single trapped antiproton, stored in a cryogenic Penning-trap system. We apply a multi-trap technique (8), detect the antiproton spin-state using the continuous Stern-Gerlach-effect (9), and transport the particle to the homogeneous and stabilized magnetic field of a precision trap (PT). Here, we induce the coherent dynamics, and analyze the result by a quantum-projection measurement in the analysis trap (10). In our measurements, we observe for the first time Rabi-oscillations of a single nuclear magnetic moment, and achieve in time series measurements spin inversion probabilities above 80% at spin coherence times of ≈ 50s. Scans of single-particle spin resonance spectra show inversions > 70%, at transition line-widths 16 times narrower than in our previous measurements (8), limited by cyclotron frequency measurement decoherence. This achievement marks a major step towards at least 10-fold improved measurements of the proton and antiproton magnetic moments, and thus, substantially improved tests of matter/antimatter symmetry in the baryon-sector.
- Open Access
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
Trap-integrated fluorescence detection with silicon photomultipliers for sympathetic laser cooling in a cryogenic Penning trap
We present a fluorescence-detection system for laser-cooled 9Be+ ions based on silicon photomultipliers (SiPMs) operated at 4 K and integrated into our cryogenic 1.9 T multi-Penning-trap system. Our approach enables fluorescence detection in a hermetically sealed cryogenic Penning-trap chamber with limited optical access, where state-of-the-art detection using a telescope and photomultipliers at room temperature would be extremely difficult. We characterize the properties of the SiPM in a cryocooler at 4 K, where we measure a dark count rate below 1 s−1 and a detection efficiency of 2.5(3)%. We further discuss the design of our cryogenic fluorescence-detection trap and analyze the performance of our detection system by fluorescence spectroscopy of 9Be+ ion clouds during several runs of our sympathetic laser-cooling experiment.
- 1 December 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (12)
Open AccessTrap-integrated fluorescence detection with silicon photomultipliers for sympathetic laser cooling in a cryogenic Penning trap
We present a fluorescence-detection system for laser-cooled 9Be+ ions based on silicon photomultipliers (SiPMs) operated at 4 K and integrated into our cryogenic 1.9 T multi-Penning-trap system. Our approach enables fluorescence detection in a hermetically sealed cryogenic Penning-trap chamber with limited optical access, where state-of-the-art detection using a telescope and photomultipliers at room temperature would be extremely difficult. We characterize the properties of the SiPM in a cryocooler at 4 K, where we measure a dark count rate below 1 s−1 and a detection efficiency of 2.5(3)%. We further discuss the design of our cryogenic fluorescence-detection trap and analyze the performance of our detection system by fluorescence spectroscopy of 9Be+ ion clouds during several runs of our sympathetic laser-cooling experiment.
- Open Access
- 1 November 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (11)
BASE-STEP: A transportable antiproton reservoir for fundamental interaction studies
Currently, the world’s only source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of fundamental interactions and their symmetries. However, magnetic field fluctuations from the facility operation limit the precision of upcoming measurements. To overcome this limitation, we have designed the transportable antiproton trap system BASE-STEP to relocate antiprotons to laboratories with a calm magnetic environment. We anticipate that the transportable antiproton trap will facilitate enhanced tests of charge, parity, and time-reversal invariance with antiprotons and provide new experimental possibilities of using transported antiprotons and other accelerator-produced exotic ions. We present here the technical design of the transportable trap system. This includes the transportable superconducting magnet, the cryogenic inlay consisting of the trap stack and detection systems, and the differential pumping section to suppress the residual gas flow into the cryogenic trap chamber.
- 1 November 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (11)
Open AccessBASE-STEP: A transportable antiproton reservoir for fundamental interaction studies
Currently, the world’s only source of low-energy antiprotons is the AD/ELENA facility located at CERN. To date, all precision measurements on single antiprotons have been conducted at this facility and provide stringent tests of fundamental interactions and their symmetries. However, magnetic field fluctuations from the facility operation limit the precision of upcoming measurements. To overcome this limitation, we have designed the transportable antiproton trap system BASE-STEP to relocate antiprotons to laboratories with a calm magnetic environment. We anticipate that the transportable antiproton trap will facilitate enhanced tests of charge, parity, and time-reversal invariance with antiprotons and provide new experimental possibilities of using transported antiprotons and other accelerator-produced exotic ions. We present here the technical design of the transportable trap system. This includes the transportable superconducting magnet, the cryogenic inlay consisting of the trap stack and detection systems, and the differential pumping section to suppress the residual gas flow into the cryogenic trap chamber.
- Open Access
- 1 October 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (10)
Ultra-thin polymer foil cryogenic window for antiproton deceleration and storage
We present the design and characterization of a cryogenic window based on an ultra-thin aluminized biaxially oriented polyethylene terephthalate foil at T < 10 K, which can withstand a pressure difference larger than 1 bar at a leak rate <1×10−9 mbar l/s. Its thickness of ∼1.7 μm makes it transparent to various types of particles over a broad energy range. To optimize the transfer of 100 keV antiprotons through the window, we tested the degrading properties of different aluminum coated polymer foils of thicknesses between 900 and 2160 nm, concluding that 1760 nm foil decelerates antiprotons to an average energy of 5 keV. We have also explicitly studied the permeation as a function of coating thickness and temperature and have performed extensive thermal and mechanical endurance and stress tests. Our final design integrated into the experiment has an effective open surface consisting of seven holes with a diameter of 1 mm and will transmit up to 2.5% of the injected 100 keV antiproton beam delivered by the Antiproton Decelerator and Extra Low ENergy Antiproton ring facility of CERN.
- 1 October 2023
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 94 (10)
Open AccessUltra-thin polymer foil cryogenic window for antiproton deceleration and storage
We present the design and characterization of a cryogenic window based on an ultra-thin aluminized biaxially oriented polyethylene terephthalate foil at T < 10 K, which can withstand a pressure difference larger than 1 bar at a leak rate <1×10−9 mbar l/s. Its thickness of ∼1.7 μm makes it transparent to various types of particles over a broad energy range. To optimize the transfer of 100 keV antiprotons through the window, we tested the degrading properties of different aluminum coated polymer foils of thicknesses between 900 and 2160 nm, concluding that 1760 nm foil decelerates antiprotons to an average energy of 5 keV. We have also explicitly studied the permeation as a function of coating thickness and temperature and have performed extensive thermal and mechanical endurance and stress tests. Our final design integrated into the experiment has an effective open surface consisting of seven holes with a diameter of 1 mm and will transmit up to 2.5% of the injected 100 keV antiproton beam delivered by the Antiproton Decelerator and Extra Low ENergy Antiproton ring facility of CERN.
- Open Access
- 1 August 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (8) , 083303
Reducing the background temperature for cyclotron cooling in a cryogenic Penning–Malmberg trap
Magnetized nonneutral plasma composed of electrons or positrons couples to the local microwave environment via cyclotron radiation. The equilibrium plasma temperature depends on the microwave energy density near the cyclotron frequency. Fine copper meshes and cryogenic microwave absorbing material were used to lower the effective temperature of the radiation environment in ASACUSA's Cusp trap, resulting in significantly reduced plasma temperature.
- 1 August 2022
- Published by AIP Publishing in Physics of Plasmas
- Vol. 29 (8) , 083303
Open AccessReducing the background temperature for cyclotron cooling in a cryogenic Penning–Malmberg trap
Magnetized nonneutral plasma composed of electrons or positrons couples to the local microwave environment via cyclotron radiation. The equilibrium plasma temperature depends on the microwave energy density near the cyclotron frequency. Fine copper meshes and cryogenic microwave absorbing material were used to lower the effective temperature of the radiation environment in ASACUSA's Cusp trap, resulting in significantly reduced plasma temperature.