Susana Moreira
Research Subjects
Susana Moreira has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Paulo Barbosa Lourenco
University of Minho
6 shared publications - Luis F. Ramos
ISISE, Department of Civil Engineering, University of Minho, Guimarães, Portugal
5 shared publications - Rafael Aguilar
Pontificia Universidad Católica del Perú
4 shared publications - Carolina Briceño
Department of Civil Engineering
3 shared publications - Daniel Vicentini Oliveira
University of Minho
3 shared publications Mauricio Gonzales
Pontificia Universidad Católica del Perú - PUCP
2 shared publications
Latest Publications
- 1 January 2022
- Published by Lviv Polytechnic National University in Current Issues in Research, Conservation and Restoration of Historic Fortifications
- Vol. 17 (2022) , 9-21
CROSS-BORDER FORTRESSES IN PORTUGAL; INSPECTION AND DIAGNOSIS
Aiming at promoting careful and heritage-respecting rehabilitation interventions, in line with the recommendations of ICOMOS (International Council on Monuments and Sites), the Rehabilitation Nucleus of the Construction Institute (NR-IC), integrated in the Faculty of Engineering of the University of Porto (FEUP), has participated in several conservation and requalification projects. The development and implementation of a consolidated and holistic methodology of inspection and diagnosis aims to intervene in these historic structures by respecting their authenticity and integrity. This paper focused on the NR-IC experience in the analysis, inspection, and diagnosis of structures with ancient defensive walls existing in Portugal’s border, while addressing several practical cases in different contexts and state of conservation. These structures have lost their original defense function, assuming nowadays a symbolic character of historical memory. In some cases, these structures were maintained, although in other cases they were abandoned, having reached the present time quite degraded. In this context, this paper focuses on three cases studies: the Cross-border Fortresses on the river Minho (Portugal-Spain border), the Guimarães Castle, cradle of the Portuguese nationality; and the Peniche Fortress representing maritime defensive structures. The wall’s structural system is characterized as well as the distinct inspection and diagnoses approaches recommended for each structure. Particularly, the systematization, recording, and processing of information is described and commented during the inspection phase, taking into account the large size of most of the structures involved.
- 1 January 2022
- Published by Lviv Polytechnic National University in Current Issues in Research, Conservation and Restoration of Historic Fortifications
- Vol. 17 (2022) , 9-21
CROSS-BORDER FORTRESSES IN PORTUGAL; INSPECTION AND DIAGNOSIS
Aiming at promoting careful and heritage-respecting rehabilitation interventions, in line with the recommendations of ICOMOS (International Council on Monuments and Sites), the Rehabilitation Nucleus of the Construction Institute (NR-IC), integrated in the Faculty of Engineering of the University of Porto (FEUP), has participated in several conservation and requalification projects. The development and implementation of a consolidated and holistic methodology of inspection and diagnosis aims to intervene in these historic structures by respecting their authenticity and integrity. This paper focused on the NR-IC experience in the analysis, inspection, and diagnosis of structures with ancient defensive walls existing in Portugal’s border, while addressing several practical cases in different contexts and state of conservation. These structures have lost their original defense function, assuming nowadays a symbolic character of historical memory. In some cases, these structures were maintained, although in other cases they were abandoned, having reached the present time quite degraded. In this context, this paper focuses on three cases studies: the Cross-border Fortresses on the river Minho (Portugal-Spain border), the Guimarães Castle, cradle of the Portuguese nationality; and the Peniche Fortress representing maritime defensive structures. The wall’s structural system is characterized as well as the distinct inspection and diagnoses approaches recommended for each structure. Particularly, the systematization, recording, and processing of information is described and commented during the inspection phase, taking into account the large size of most of the structures involved.
- 1 January 2019
- Published by Springer Nature
- p. 1462-1470
Seismic Assessment of the Church of San Sebastian in Cusco, Peru by Means of Pushover Nonlinear Analysis
- 1 January 2019
- Published by Springer Nature
- p. 1462-1470
Seismic Assessment of the Church of San Sebastian in Cusco, Peru by Means of Pushover Nonlinear Analysis
- 1 January 2019
- Published by Springer Nature
- p. 2431-2438
Preliminary Structural Diagnosis of the Sacsamarca Church in Peru Using Photogrammetry and IR Thermography
- 1 January 2019
- Published by Springer Nature
- p. 2431-2438
Preliminary Structural Diagnosis of the Sacsamarca Church in Peru Using Photogrammetry and IR Thermography
- 26 July 2018
- Published by Taylor & Francis in International Journal of Architectural Heritage
- Vol. 13 (1) , 140-152
SEISMIC VULNERABILITY ASSESSMENT OF A 17th CENTURY ADOBE CHURCH IN THE PERUVIAN ANDES
A large part of Peruvian heritage corresponds to Colonial Andean churches, which are economically and culturally essential for the development of several villages. Particularly, adobe churches are very vulnerable to earthquakes due to the brittle material behavior, the weak connections, and the absence of a rigid diaphragm. This article aims at performing the seismic vulnerability assessment of an adobe heritage church: “Virgen de la Asuncion” of Sacsamarca located in the province of Ayacucho in the Andean region of Peru; using a rapid screening method and a more complex numerical analysis. First, the damage survey was carried out through visual inspection and infrared thermography, while the material characterization was performed by applying flat-jack tests. Later, the seismic vulnerability assessment was carried out in two stages. The first was based on simplified criteria for masonry structures, and the other on a pushover analysis of global performance. From this evaluation, it was possible to conclude that the church is indeed vulnerable to Peruvian seismic demands.
- 26 July 2018
- Published by Taylor & Francis in International Journal of Architectural Heritage
- Vol. 13 (1) , 140-152
SEISMIC VULNERABILITY ASSESSMENT OF A 17th CENTURY ADOBE CHURCH IN THE PERUVIAN ANDES
A large part of Peruvian heritage corresponds to Colonial Andean churches, which are economically and culturally essential for the development of several villages. Particularly, adobe churches are very vulnerable to earthquakes due to the brittle material behavior, the weak connections, and the absence of a rigid diaphragm. This article aims at performing the seismic vulnerability assessment of an adobe heritage church: “Virgen de la Asuncion” of Sacsamarca located in the province of Ayacucho in the Andean region of Peru; using a rapid screening method and a more complex numerical analysis. First, the damage survey was carried out through visual inspection and infrared thermography, while the material characterization was performed by applying flat-jack tests. Later, the seismic vulnerability assessment was carried out in two stages. The first was based on simplified criteria for masonry structures, and the other on a pushover analysis of global performance. From this evaluation, it was possible to conclude that the church is indeed vulnerable to Peruvian seismic demands.
- 1 February 2018
- Published by Elsevier in Construction and Building Materials
- Vol. 163, 643-655
Experimental results on mechanical behaviour of metal anchors in historic stone masonry
- 1 February 2018
- Published by Elsevier in Construction and Building Materials
- Vol. 163, 643-655
Experimental results on mechanical behaviour of metal anchors in historic stone masonry
- 3 November 2016
- Published by Taylor & Francis
- p. 1590-1597
Seismic design of tension wall-diaphragm anchorage for historical unreinforced masonry buildings
The absence of appropriate structural connections is known to be one of the main factors contributing to the activation of out-of-plane mechanisms of masonry walls that can compromise the entire stability of a building. The high vulnerability of historical unreinforced masonry buildings to these types of mechanisms imposes the necessity to develop engineered strengthening solutions capable of ensuring positive wall-diaphragm anchorage to work in tension. A design methodology was developed covering aspects related to the estimation of the seismic demand and the design of a retrofit solution studied experimentally. The proposed design for the tension wall-diaphragm anchorage is one more step for the integrated approach to develop an "engineered strengthening", which started with the experimental campaign on the prototypes proposed by the company Monumenta Lda. The proposed procedure is a force-based design method and aims at assisting practitioners on implementing a simplified calculation of the tension anchors.
- 3 November 2016
- Published by Taylor & Francis
- p. 1590-1597
Seismic design of tension wall-diaphragm anchorage for historical unreinforced masonry buildings
The absence of appropriate structural connections is known to be one of the main factors contributing to the activation of out-of-plane mechanisms of masonry walls that can compromise the entire stability of a building. The high vulnerability of historical unreinforced masonry buildings to these types of mechanisms imposes the necessity to develop engineered strengthening solutions capable of ensuring positive wall-diaphragm anchorage to work in tension. A design methodology was developed covering aspects related to the estimation of the seismic demand and the design of a retrofit solution studied experimentally. The proposed design for the tension wall-diaphragm anchorage is one more step for the integrated approach to develop an "engineered strengthening", which started with the experimental campaign on the prototypes proposed by the company Monumenta Lda. The proposed procedure is a force-based design method and aims at assisting practitioners on implementing a simplified calculation of the tension anchors.
A students' challenge for the estimation of the maximum compressive load of masonry prisms / Studentenwettbewerb zur Ermittlung der maximalen Druckfestigkeit von Mauerwerksprismen
The paper presents the “IMC Students' Challenge” competition held in 2014, during the 9th International Masonry Conference, in Guimarães. The objective of the competition was to predict the maximum compressive load of two masonry prisms built of solid bricks, and of hollow blocks, with mortar joints. To increase the complexity of the problem, all prisms were tested under eccentric load. The students, who enthusiastically participated in the final laboratory tests, presented different approaches to estimate the maximum eccentric compressive force on masonry prisms. The challenge was a great experience, not only for students and conference participants, but also for sponsors and organizers.
A students' challenge for the estimation of the maximum compressive load of masonry prisms / Studentenwettbewerb zur Ermittlung der maximalen Druckfestigkeit von Mauerwerksprismen
The paper presents the “IMC Students' Challenge” competition held in 2014, during the 9th International Masonry Conference, in Guimarães. The objective of the competition was to predict the maximum compressive load of two masonry prisms built of solid bricks, and of hollow blocks, with mortar joints. To increase the complexity of the problem, all prisms were tested under eccentric load. The students, who enthusiastically participated in the final laboratory tests, presented different approaches to estimate the maximum eccentric compressive force on masonry prisms. The challenge was a great experience, not only for students and conference participants, but also for sponsors and organizers.
- 15 December 2015
- Published by Taylor & Francis in International Journal of Architectural Heritage
- Vol. 10 (2-3) , 217-234
Design Parameters for Seismically Retrofitted Masonry-To-Timber Connections: Injection Anchors
Proper structural connections play an important role in ensuring seismic loads distribution and developing global damage mechanisms of structures. In historical unreinforced masonry buildings, effective connections between masonry walls and timber floors or walls through the use of anchors can prevent the occurrence of out-of-plane mechanisms and promote box-like behavior. Particularly for historic structures, injection anchors can comply with requirements as decreased architectural impact and minimum intervention. Therefore, this article aims at developing structural design parameters and recommendations that allow the design of connections retrofitted with injection anchors, found in historical unreinforced masonry buildings, built during the 19th century, in Portugal. Existing strength prediction formulae based on behavior models, and idealized force-displacement curves were developed to better fit the results obtained from a series of quasi-static monotonic and cyclic pullout tests carried out on pairs of injection anchors. Behavior models were able to approximate the experimental results, if adapted to the specificities of historical masonry. Further validation is needed, particularly for the combined cone-bond model. From the idealized curves, displacement acceptance criteria, expected forces, and behavior factors were proposed, according to the performance-based approaches recommended by EC8-Part 3 and ASCE/SEI 41–13. Finally, retrofit design recommendations were addressed.
- 15 December 2015
- Published by Taylor & Francis in International Journal of Architectural Heritage
- Vol. 10 (2-3) , 217-234
Design Parameters for Seismically Retrofitted Masonry-To-Timber Connections: Injection Anchors
Proper structural connections play an important role in ensuring seismic loads distribution and developing global damage mechanisms of structures. In historical unreinforced masonry buildings, effective connections between masonry walls and timber floors or walls through the use of anchors can prevent the occurrence of out-of-plane mechanisms and promote box-like behavior. Particularly for historic structures, injection anchors can comply with requirements as decreased architectural impact and minimum intervention. Therefore, this article aims at developing structural design parameters and recommendations that allow the design of connections retrofitted with injection anchors, found in historical unreinforced masonry buildings, built during the 19th century, in Portugal. Existing strength prediction formulae based on behavior models, and idealized force-displacement curves were developed to better fit the results obtained from a series of quasi-static monotonic and cyclic pullout tests carried out on pairs of injection anchors. Behavior models were able to approximate the experimental results, if adapted to the specificities of historical masonry. Further validation is needed, particularly for the combined cone-bond model. From the idealized curves, displacement acceptance criteria, expected forces, and behavior factors were proposed, according to the performance-based approaches recommended by EC8-Part 3 and ASCE/SEI 41–13. Finally, retrofit design recommendations were addressed.
- 1 December 2014
- Published by Elsevier in Engineering Structures
- Vol. 81, 98-109
Experimental behavior of masonry wall-to-timber elements connections strengthened with injection anchors
- 1 December 2014
- Published by Elsevier in Engineering Structures
- Vol. 81, 98-109
Experimental behavior of masonry wall-to-timber elements connections strengthened with injection anchors
- 1 February 2013
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 35 (1-2) , 1-15
Dynamic structural health monitoring of Saint Torcato church
- 1 February 2013
- Published by Elsevier in Mechanical Systems and Signal Processing
- Vol. 35 (1-2) , 1-15
Dynamic structural health monitoring of Saint Torcato church