MBMatheus Coelho Bandeca

Matheus Coelho Bandeca

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Matheus Coelho Bandeca has a total of 260 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Clinical performance of preheating thermoviscous composite resin for non-carious cervical lesions restoration: A 24-month randomized clinical trial

    by Michael Willian Favoreto, Taynara de Souza Carneiro, Romina Ñaupari-Villasante, Deisy Cristina Cordeiro, Gabriel David Cochinski, Thais Vilalba Paniagua Machado Do Nascimento, Thalita de Paris Matos, Matheus Coelho Bandeca, Alessandra Reis, Alessandro D. Loguercio


  • Open Access

    A 48-month clinical performance of hybrid ceramic fragment restorations manufactured in CAD/CAM in non-carious cervical lesions: case report

    by Michael Willian Favoreto, Gabriel David Cochinski, Eveline Claudia Martini, Thalita de Paris Matos, Matheus Coelho Bandeca, Alessandro Dourado Loguercio

    Favoreto MW, et al. Restor Dent Endod. 2024 Aug;49(3):e32. https://doi.org/10.5395/rde.2024.49.e32


  • Open Access

    In-office dental bleaching in adolescents using 6% hydrogen peroxide with different application tips: randomized clinical trial

    by Taynara de Souza Carneiro, Michael Willian Favoreto, Michel Wendlinger Cantanhede Ferreira, Laís Giacomini Bernardi, Heloísa Forville de Andrade, Matheus Coelho Bandeca, Alessandra Reis, Laura Ceballos García, Alessandro Dourado Loguercio

    Despite the availability of in-office bleaching gels with a 6% concentration of hydrogen peroxide (HP), these gels have not been evaluated in younger patients. They are commercially available with a tip, associated or not with a brush, where the tip with a brush spreads the gel over the entire surface to have a smaller thickness (thin layer) since the manufacturers indicate the application of a thin layer of gel.


  • Análise da capacidade de vedamento bacteriano na interface entre implante e pilar em dois sistemas de junção / Analysis of bacterial sealing capacity at the interface between implants and abutments in two joining systems

    by Marcelly Anny Gonçalves de Oliveira, Michael Willian Favoreto, Andriele Breus Portela, Camila Mendes Camargo, Fábio André dos Santos, Marcela Claudino da Silva Nardino, Matheus Coelho Bandeca, Shelon Cristina Souza Pinto

    Avaliar in vitro a contaminação bacteriana na interface implante-pilar em implantes dentários com conexões dos tipos hexágono interno e hexágono externo, por meio de análise microbiológica. Foram analisados 24 conjuntos (n = 12), os quais foram divididos nos seguintes grupos: conexão hexágono interno (HI); conexão hexágono externo (HE); controle positivo (CP) e controle negativo (CN). Todos os grupos foram contaminados no interior do implante com Escherichia coli, exceto o grupo CN. Em seguida, os pilares foram conectados, aplicado torque de 20 N e os conjuntos foram imersos em uma solução de caldo Brain Heart Infusion (BHI), onde foram mantidos durante 14 dias. Os conjuntos foram desconectados por contra torque e porções do caldo de cultura foram coletadas e plaqueadas em Ágar BHI por 24 horas, para observar a formação das unidades formadoras de colônias (CFUs). Depois, foi realizada a coleta de uma porção das CFUs para esfregaço e coloração de Gram. Após os 14 dias, houve turbidez do meio e presença de depósitos em 6/11 tubos de ensaio do hexágono interno e 5/11 para hexágono externo, não havendo diferença estatística (p > 0,05) entre os grupos. Foi confirmado o crescimento dos bacilos Gram-negativos, onde foi possível visualizar a presença de Escherichia coli nas placas correspondentes aos tubos de ensaio que apresentaram turbidez anteriormente. Os resultados do presente estudo sugerem que o tipo de implante não beneficia a redução da contaminação bacteriana através da conexão implante-pilar.

  • Open Access

    Dimensional stability of stored extended-pour irreversible hydrocolloids materials

    by Rudys Rodolfo de Jesus Tavarez, Etevaldo Matos Maia-Filho, Adriana Santos Malheiros, Oswaldo Serra Santos-Neto, Shelon Cristina Souza Pinto, Flavio das Neves, Leticia Machado Gonçalves, Matheus Coelho Bandeca

    The purpose of this study was to evaluate the linear dimensional stability of four extended-pour irreversible hydrocolloids (EPIHs). Material and Methods: Five samples per material (Cavex ColorChange, Cavex Orthotrace, Jeltrate Plus, and Orthoprint) were prepared following the manufacturers’ instructions. The samples were prepared using a cylindrical matrix coupled with a nylon-polyamide ring. Two parallel, 25-mm equidistant lines were made on its surface following ANSI/American Dental Association (ADA) Specification 18 for plaster reproducibility and compatibility and Specification 19 for linear dimensional change. The samples were stored in an environment with a relative humidity of 70% (± 3) and temperature of 28°C (± 2). Photo images were obtained using a digital camera to record images for 120 hours, with a standardized distance of 80cm between the lens and the specimen. Adobe Photoshop CS3 software was used for the measurement of the recorded images. The measurements refer to the equivalent distance between the two parallel lines printed on the samples. Data were analyzed using one-way analysis of variance (ANOVA) and Tukey’s test for multiple comparisons between the means of the groups. Results: There was no statistically significant difference (p > 0.05) when EPIHs were compared at the same time of evaluation. Orthoprint, Cavex Orthotrace, and Cavex Colorchange presented with least dimensional stability up to 24 hours (p > 0.05) of storage, followed by Jeltrate Plus (48 hours). Conclusions: Storage of EPIHs for more than 24 hours for Cavex ColorChange and 48 hours for others EPIHs studied produces significant dimensional changes in the impressions stored at a humidity of 70% (± 3) and temperature of 28°C (± 2). Extended storage times produce large dimensional changes.


  • Open Access

    Personality traits, psychosocial effects and quality of life of patients submitted to dental bleaching

    by Elize Bonafé, Márcia Rezende, Marina Molinari Machado, Suellen Nogueira Linares Lima, Eduardo Fernandez, Marcia M. P. Baldani, Alessandra Reis, Alessandro Dourado Loguercio, Matheus Coelho Bandeca

    Background: Perception is defined as the ability to distinguish through the senses. All perception is dependent on factors such as personality, previously lived experiences and cultural elements. When planning an aesthetic treatment, consider the way the patients perceive the changes and outcomes is essential for reaching their expectations. The objective of this study was to assess if there was predominance of a personality trait of patient undergoing dental bleaching and if this treatment could promote changes in this traits, in the psychosocial impact and quality of life of these individuals. Methods: The assessment of personality characteristics, quality of life, psychosocial and self-perception was a cross-sectional observational study and it was carried out by applying questionnaires to 55 patients that were submitted to a clinical phase. The psychometric instruments used were NEO FFI-R (personality), PIDAQ (psychosocial effect) and WHOQOL-BREF (quality of life). Each test domain was prior and after bleaching by Wilcoxon Signed Rank test (α = 0.05). The internal consistencies of each scale were evaluated by Cronbach's alpha. Results: No statistical significant differences among personality traits means were observed among participants but there was predominance of two predominant personality traits in this study: conscientiousness (45.5%) and extraversion (34.5%). In four test domains of the PIDAQ, significant differences were observed before and after dental bleaching. The overall perception of the PIDAQ was also statistically significant demonstrating an improvement. There were no differences on overall or specific domains scores of the WHOQOL before and after treatment. Conclusions: Subjects who underwent dental treatment improved their self-confidence and reduced concerns about dental aesthetics, social and personality impact of dental alterations. Trial registration: This study was conducted in parallel to a clinical investigation that aimed to evaluate tooth sensitivity related to dental bleaching technique and registered in REBEC clinical registry under protocol RBR-6pt2n3 in 13 November 2013.


  • Open Access

    Evaluation of the Bond Strength of Densely Sintered Ceramics Subjected to Extended Firing

    by Samuel Oliveira Costa, Suellen Nogueira Linares Lima, Maria Victória Nassif, Andres Felipe Millan Cardenas, Rudys Rodolfo de Jesus Tavarez, Darlon Martins Lima, Matheus Coelho Bandeca

    Introduction: Critical failures in ceramic materials can be caused by the processing mode, which includes all steps taken in the manufacture of a ceramic part, from molding to firing. Purpose: To evaluate the effect of extended firing on bond strength in densely sintered ceramics of the zirconium reinforced lithium silicate, lithium disilicate, and feldspathic ceramic. Materials and Methods: Three types of ceramics were evaluated: zirconium reinforced lithium silicate, lithium disilicate, feldspathic ceramic. A total of 6 ceramic blocks, two for each material were used in the study. Each block was cut into four square sections. A total of 24 ceramic surfaces were randomly distributed into 6 groups (n = 4 surfaces per group) divided according to the variables: heat treatment: conventional firing or extended firing; test time: immediate (24 hours after cementation) or longevity (after 1000 cycles of thermo-cycling). The bond strength tests were performed in a semi-universal test machine for microshear bond strength. For data analysis, the Shapiro-Wilk test was performed to evaluate the normality between the groups measured, and regarding homoscedasticity (homogeneity of variances) by the Bartlett test. The comparisons between the groups were made using the nonparametric Kruskal-Wallis test. Results: There was no statistically significant difference of the resistance values in relation to the thermal treatment methods (conventional firing and extended firing) in any ceramic group (p <0.05). Among the times (immediate and long), there was a statistically significant difference (p <0.05), with higher resistance values for immediate time. Conclusion: Extended firing did not influence the micro-shear bond strength of zirconium reinforced lithium silicate, lithium disilicate, feldspathic ceramic.

  • Open Access

    Effect of surface treatments on the adhesive properties of metallic brackets on fluorotic enamel

    by Mariana Huilcapi, Ana Armas-Vega, Andres Felipe Millan Cardenas, Lucila Cristina Rodrigues Araujo, Jessica Bedoya Ocampo, Matheus Coelho Bandeca, Fabiana Suelen Figuerêdo de Siqueira, Alessandro Loguercio

    Objective: To compare the effectiveness of the pretreatment with sandblasting and deproteinization with NaOCl on bond strength (SBS), in situ conversion degree (CD) of brackets in fluorotic enamel, and enamel etching pattern. Methods: A total of 90 non-carious maxillary premolars were used. The teeth were then assigned to six experimental groups according to: enamel surface (sound and fluorotic enamel); surface treatment (Regular etch with 37% phosphoric acid [RE]; 5.2% sodium hypochlorite + phosphoric acid [NaOCl + RE]; sandblasting + phosphoric acid [sandblasting + RE]). After storage in distilled water (37°C/24h), the specimens were tested at 1 mm/min until failure (SBS). Enamel-resin cement interfaces were evaluated for CD using micro-Raman spectroscopy. The enamel-etching pattern was evaluated under a scanning electron microscope. Data from SBS and in situ CD values were analyzed using ANOVA two-away and Tukey test (α=0.05). The enamel etching pattern was evaluated only qualitatively. Results: For sound enamel, RE showed the highest SBS values, when compared to NaOCl + RE and Sandblasting + RE groups (p< 0.01). Regarding CD, only NaOCl + RE significantly compromised the mean DC, in comparison with other groups (p= 0.002). For fluorotic enamel, the Sandblasting + RE group significantly increased the mean SBS values, in comparison with RE group (p= 0.01) and no significant change was observed for CD (p> 0.52). Conclusions: The application of NaOCl or sandblasting associated to phosphoric acid improved the SBS of the brackets in fluorotic enamel without compromising the CD of the resin cement, with improving of enamel interprismatic conditioning.


  • Open Access

    Co-Loaded Curcumin and Methotrexate Nanocapsules Enhance Cytotoxicity against Non-Small-Cell Lung Cancer Cells

    by Loanda Aparecida Cabral Rudnik, Paulo Vitor Farago, Jane Manfron Budel, Amanda Lyra, Fernanda Malaquias Barboza, Traudi Klein, Carla Cristine Kanunfre, Jessica Mendes Nadal, Matheus Coelho Bandéca, Vijayasankar Raman, et al.

    Background: As part of the efforts to find natural alternatives for cancer treatment and to overcome the barriers of cellular resistance to chemotherapeutic agents, polymeric nanocapsules containing curcumin and/or methotrexate were prepared by an interfacial deposition of preformed polymer method. Methods: Physicochemical properties, drug release experiments and in vitro cytotoxicity of these nanocapsules were performed against the Calu-3 lung cancer cell line. Results: The colloidal suspensions of nanocapsules showed suitable size (287 to 325 nm), negative charge (−33 to −41 mV) and high encapsulation efficiency (82.4 to 99.4%). Spherical particles at nanoscale dimensions were observed by scanning electron microscopy. X-ray diffraction analysis indicated that nanocapsules exhibited a non-crystalline pattern with a remarkable decrease of crystalline peaks of the raw materials. Fourier-transform infrared spectra demonstrated no chemical bond between the drug(s) and polymers. Drug release experiments evidenced a controlled release pattern with no burst effect for nanocapsules containing curcumin and/or methotrexate. The nanoformulation containing curcumin and methotrexate (NCUR/MTX-2) statistically decreased the cell viability of Calu-3. The fluorescence and morphological analyses presented a predominance of early apoptosis and late apoptosis as the main death mechanisms for Calu-3. Conclusions: Curcumin and methotrexate co-loaded nanocapsules can be further used as a novel therapeutic strategy for treating non-small-cell lung cancer.


  • Open Access

    Comparison of three methods for monitoring dentin erosion progression

    by Shelon Cristina Souza Pinto, Suellen Nogueira Linares Lima, Maria Vitoria Nassif, Christian Zakian, Hooi Pin Chew, Ian Pretty, Roger Ellwood, José Eduardo Cezar Sampaio, Matheus Bandeca

    Background: Clinical assessment and monitoring of dental erosion in vivo is challenging, although a number of clinical indices have been proposed but these are unlikely to be sensitive enough to quantify erosion with sufficient sensitivity to allow comparison of different therapies. In this respect, some of the techniques predominantly employed for the assessment of dental caries such as Quantitative light- induced fluorescence (QLF) and Optical coherence tomography (OCT) may also have utility for the assessment for erosion both in vivo and in vitro. The aim of the present study was to test three techniques (QLF, OCT and SMH) for the assessment of dentine erosion in a product testing model, using dentifrices to reduce erosion susceptibility. Dentine erosion was evaluated comparing the methods. Methods: Human dentine specimens were treated with one of two dentifrice slurries or mineral water (control group), followed by an erosive challenge and storage overnight in artificial saliva. These procedures were performed over 5 days. The following two dentifrices were tested: Duraphat™ 5000 (5000ppm Sodium Fluoride) and Colgate Sensitive Pro-Relief™ (8% arginine plus calcium carbonate and 1450ppm Fluoride). All groups showed a progressivedecrease in SMH and increase in scattering for OCT (P<0.05) indicating mineral loss. Results: The two dentifrice groups demonstrated significantly less softening than the control group (P0.05). Conclusion: SMH and OCT techniques were able to detect a significant protective effect against in vitro erosion whensamples were pre-treated with either dentifrice formulation. Dentifrices containing high concentrations of fluoride andarginine associated with calcium carbonate and fluoride have a protective effect against dentinal erosion.