Eric A. Burt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Eric A. Burt has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Todd A. Ely
Jet Propulsion Laboratory, California Institute of Technology, Pasadena, USA
5 shared publications Robert L. Tjoelker
Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA, USA
3 shared publications- Daphna G. Enzer
Jet Propulsion Laboratory, California Institute of Technology, Pasadena, CA, USA
2 shared publications - Fabrizio De Marchi
Department of Mechanical and Aerospace Engineering, Sapienza University of Rome, 00184 Rome, Italy
2 shared publications - Luciano Iess
Sapienza University of Rome
2 shared publications D. E. Robison
Jet Propulsion Laboratory, California Institute of Technology, Pasadena, USA
1 shared publication
Latest Publications
- Open Access
- 6 June 2026
- Published by American Geophysical Union (AGU) in Radio Science
- Vol. 61 (6)
Frequency Standard Contributions to Limitations on the Signal‐to‐Noise Ratio in Very Long Baseline Interferometric Observations
Since its observation in 2019, the first image of a super-massive black hole using Very Long Baseline Interferometry (VLBI) with an Earth-scale baseline has generated much scientific and public interest. Work is now underway to extend the baseline into space to obtain higher image resolution. Operating one or more VLBI nodes in space will require the use of frequency standards that are space-qualified, greatly reducing the number of options available. The coherence function is the metric usually used to determine the viability of a frequency standard. Here we show that is a useful but not sufficient metric for gauging frequency standard performance in VLBI and instead derive an expression for the clock-limited VLBI visibility S/N. We evaluate this expression for real frequency standards and find only the Ultra-Stable Oscillator (USO) and hydrogen maser to be viable for upcoming high-frequency VLBI with the USO only useful for very limited integration times (30 seconds at 90 GHz, 10 seconds at 230 GHz, 5 seconds at 345 GHz, and not viable at 630 GHz). The maser extends these, but may have prohibitive size for a space mission. We also evaluate emerging frequency standard technologies and find the optical local oscillator portion of optical clocks to be very promising (conservatively >100 seconds at 90 GHz, 60 seconds at 230 GHz, 40 seconds at 345 GHz, and 22 seconds at 630 GHz) when accounting for both performance and potential operation in space.- 6 June 2026
- Published by American Geophysical Union (AGU) in Radio Science
- Vol. 61 (6)
Open AccessFrequency Standard Contributions to Limitations on the Signal‐to‐Noise Ratio in Very Long Baseline Interferometric Observations
Since its observation in 2019, the first image of a super-massive black hole using Very Long Baseline Interferometry (VLBI) with an Earth-scale baseline has generated much scientific and public interest. Work is now underway to extend the baseline into space to obtain higher image resolution. Operating one or more VLBI nodes in space will require the use of frequency standards that are space-qualified, greatly reducing the number of options available. The coherence function is the metric usually used to determine the viability of a frequency standard. Here we show that is a useful but not sufficient metric for gauging frequency standard performance in VLBI and instead derive an expression for the clock-limited VLBI visibility S/N. We evaluate this expression for real frequency standards and find only the Ultra-Stable Oscillator (USO) and hydrogen maser to be viable for upcoming high-frequency VLBI with the USO only useful for very limited integration times (30 seconds at 90 GHz, 10 seconds at 230 GHz, 5 seconds at 345 GHz, and not viable at 630 GHz). The maser extends these, but may have prohibitive size for a space mission. We also evaluate emerging frequency standard technologies and find the optical local oscillator portion of optical clocks to be very promising (conservatively >100 seconds at 90 GHz, 60 seconds at 230 GHz, 40 seconds at 345 GHz, and 22 seconds at 630 GHz) when accounting for both performance and potential operation in space. - 11 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (4) , 506-515
An Algorithm to Estimate the Power Spectral Density From Allan Deviation
Complex architectures for wireless communications, digital electronics and space-based navigation interlink several oscillator-based devices such as clocks, transponders and synthesizers. Estimators characterizing their stability are critical for addressing the impact of random fluctuations (noise) on the overall system performance. Manufacturers typically specify this as an Allan/Hadamard Variance (AVAR/HVAR) profile in the time domain. However, stochastic processes constituting the noise are more thoroughly described in the frequency domain by the power spectral density function (PSD). Both are second-moment measures of the time series, but it is only possible to translate unambiguously from the PSD to the AVAR/HVAR, not vice versa, except in the case of a single noise type, a rather unrealistic case. This note presents an analytical method to generate an approximated PSD expressed as a set of power-laws defined in specific intervals in the frequency domain, starting from an AVAR/HVAR expressed as a set of power-laws in the time domain. The proposed algorithm is straightforward to implement, applicable to all noise types (and combinations thereof) and can be self-validated by reconstructing the corresponding AVAR/HVAR by direct computation. Coupling with well-established algorithms relying on the PSD for power-law noise generation [18], the ensuing method encompasses the capability for generating multi-colored noise in end-to-end simulations, as demonstrated hereby for NASA’s Deep Space Atomic Clock. We also report on the limitations of the algorithm and analytical expressions of the continuous version of the algorithm.
- 11 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 71 (4) , 506-515
An Algorithm to Estimate the Power Spectral Density From Allan Deviation
Complex architectures for wireless communications, digital electronics and space-based navigation interlink several oscillator-based devices such as clocks, transponders and synthesizers. Estimators characterizing their stability are critical for addressing the impact of random fluctuations (noise) on the overall system performance. Manufacturers typically specify this as an Allan/Hadamard Variance (AVAR/HVAR) profile in the time domain. However, stochastic processes constituting the noise are more thoroughly described in the frequency domain by the power spectral density function (PSD). Both are second-moment measures of the time series, but it is only possible to translate unambiguously from the PSD to the AVAR/HVAR, not vice versa, except in the case of a single noise type, a rather unrealistic case. This note presents an analytical method to generate an approximated PSD expressed as a set of power-laws defined in specific intervals in the frequency domain, starting from an AVAR/HVAR expressed as a set of power-laws in the time domain. The proposed algorithm is straightforward to implement, applicable to all noise types (and combinations thereof) and can be self-validated by reconstructing the corresponding AVAR/HVAR by direct computation. Coupling with well-established algorithms relying on the PSD for power-law noise generation [18], the ensuing method encompasses the capability for generating multi-colored noise in end-to-end simulations, as demonstrated hereby for NASA’s Deep Space Atomic Clock. We also report on the limitations of the algorithm and analytical expressions of the continuous version of the algorithm.
- 13 March 2023
- Published by American Physical Society (APS) in Physical Review D
- Vol. 107 (6) , 064032
Testing the gravitational redshift with an inner Solar System probe: The VERITAS case
The NASA Discovery-class mission VERITAS, selected in June 2021, will be launched toward Venus after 2027. In addition to the science instrumentation that will build global foundational geophysical datasets, VERITAS proposed to conduct a technology demonstration for the Deep Space Atomic Clock (DSAC-2). A first DSAC successfully operated in low-Earth orbit for more than two years, demonstrated the trapped ion atomic clock technology, and established a new level of performance for clocks in space. DSAC-2 would have further improvements in size, power, and performance. It would host a grade USO to produce a frequency output with short-term stability of less than (where is the averaging time). However, due to funding shortfalls, DSAC-2, had to be canceled. The initially foreseen presence of an atomic clock on board the probe, however, raised the question whether this kind of instrumentation could be useful not only for navigation and time transfer but also for fundamental physics tests. In this work, we consider the DSAC-2 atomic clock and VERITAS mission as a specific example to measure possible discrepancies in the redshift predicted by general relativity by using an atomic clock onboard an interplanetary spacecraft. In particular we investigate the possibility of measuring possible violations of the local Lorentz invariance and local position invariance principles. We perform accurate simulations of the experiment during the VERITAS cruise phase. We consider different parametrizations of the possible violations of the general relativity, different operational conditions, and several different assumptions on the expected measurement performance. We show that DSAC-2 onboard VERITAS would provide new and improved constraints with respect to the current knowledge. Our analysis shows the scientific value of atomic clocks like DSAC-2 hosted onboard interplanetary spacecraft.- 13 March 2023
- Published by American Physical Society (APS) in Physical Review D
- Vol. 107 (6) , 064032
Testing the gravitational redshift with an inner Solar System probe: The VERITAS case
The NASA Discovery-class mission VERITAS, selected in June 2021, will be launched toward Venus after 2027. In addition to the science instrumentation that will build global foundational geophysical datasets, VERITAS proposed to conduct a technology demonstration for the Deep Space Atomic Clock (DSAC-2). A first DSAC successfully operated in low-Earth orbit for more than two years, demonstrated the trapped ion atomic clock technology, and established a new level of performance for clocks in space. DSAC-2 would have further improvements in size, power, and performance. It would host a grade USO to produce a frequency output with short-term stability of less than (where is the averaging time). However, due to funding shortfalls, DSAC-2, had to be canceled. The initially foreseen presence of an atomic clock on board the probe, however, raised the question whether this kind of instrumentation could be useful not only for navigation and time transfer but also for fundamental physics tests. In this work, we consider the DSAC-2 atomic clock and VERITAS mission as a specific example to measure possible discrepancies in the redshift predicted by general relativity by using an atomic clock onboard an interplanetary spacecraft. In particular we investigate the possibility of measuring possible violations of the local Lorentz invariance and local position invariance principles. We perform accurate simulations of the experiment during the VERITAS cruise phase. We consider different parametrizations of the possible violations of the general relativity, different operational conditions, and several different assumptions on the expected measurement performance. We show that DSAC-2 onboard VERITAS would provide new and improved constraints with respect to the current knowledge. Our analysis shows the scientific value of atomic clocks like DSAC-2 hosted onboard interplanetary spacecraft.- 30 June 2021
- Published by Springer Nature in Nature
- Vol. 595 (7865) , 43-47
Demonstration of a trapped-ion atomic clock in space
Atomic clocks, which lock the frequency of an oscillator to the extremely stable quantized energy levels of atoms, are essential for navigation applications such as deep space exploration1 and global navigation satellite systems2, and are useful tools with which to address questions in fundamental physics3,4,5,6. Such satellite systems use precise measurement of signal propagation times determined by atomic clocks, together with propagation speed, to calculate position. Although space atomic clocks with low instability are an enabling technology for global navigation, they have not yet been applied to deep space navigation and have seen only limited application to space-based fundamental physics, owing to performance constraints imposed by the rigours of space operation7. Methods of electromagnetically trapping and cooling ions have revolutionized atomic clock performance8,9,10,11,12,13. Terrestrial trapped-ion clocks operating in the optical domain have achieved orders-of-magnitude improvements in performance over their predecessors and have become a key component in national metrology laboratory research programmes13, but transporting this new technology into space has remained challenging. Here we show the results from a trapped-ion atomic clock operating in space. On the ground, NASA’s Deep Space Atomic Clock demonstrated a short-term fractional frequency stability of 1.5 × 10−13/τ1/2 (where τ is the averaging time)14. Launched in 2019, the clock has operated for more than 12 months in space and demonstrated there a long-term stability of 3 × 10−15 at 23 days (no drift removal), and an estimated drift of 3.0(0.7) × 10−16 per day. Each of these exceeds current space clock performance by up to an order of magnitude15,16,17. The Deep Space Atomic Clock is particularly amenable to the space environment because of its low sensitivity to variations in radiation, temperature and magnetic fields. This level of space clock performance will enable one-way navigation in which signal delay times are measured in situ, making near-real-time navigation of deep space probes possible18.
- 30 June 2021
- Published by Springer Nature in Nature
- Vol. 595 (7865) , 43-47
Demonstration of a trapped-ion atomic clock in space
Atomic clocks, which lock the frequency of an oscillator to the extremely stable quantized energy levels of atoms, are essential for navigation applications such as deep space exploration1 and global navigation satellite systems2, and are useful tools with which to address questions in fundamental physics3,4,5,6. Such satellite systems use precise measurement of signal propagation times determined by atomic clocks, together with propagation speed, to calculate position. Although space atomic clocks with low instability are an enabling technology for global navigation, they have not yet been applied to deep space navigation and have seen only limited application to space-based fundamental physics, owing to performance constraints imposed by the rigours of space operation7. Methods of electromagnetically trapping and cooling ions have revolutionized atomic clock performance8,9,10,11,12,13. Terrestrial trapped-ion clocks operating in the optical domain have achieved orders-of-magnitude improvements in performance over their predecessors and have become a key component in national metrology laboratory research programmes13, but transporting this new technology into space has remained challenging. Here we show the results from a trapped-ion atomic clock operating in space. On the ground, NASA’s Deep Space Atomic Clock demonstrated a short-term fractional frequency stability of 1.5 × 10−13/τ1/2 (where τ is the averaging time)14. Launched in 2019, the clock has operated for more than 12 months in space and demonstrated there a long-term stability of 3 × 10−15 at 23 days (no drift removal), and an estimated drift of 3.0(0.7) × 10−16 per day. Each of these exceeds current space clock performance by up to an order of magnitude15,16,17. The Deep Space Atomic Clock is particularly amenable to the space environment because of its low sensitivity to variations in radiation, temperature and magnetic fields. This level of space clock performance will enable one-way navigation in which signal delay times are measured in situ, making near-real-time navigation of deep space probes possible18.
- Open Access
- 22 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (7) , 2590-2601
Allan Deviation of Atomic Clock Frequency Corrections: A New Diagnostic Tool for Characterizing Clock Disturbances
As atomic clocks and frequency standards are increasingly operated in situations where they are exposed to environmental disturbances, it becomes more necessary to understand how variations of each clock component impact the clock output, in particular the local oscillator (LO). Most microwave atomic clocks in operation today use quartz crystal LOs with excellent short-term noise variation but large unwanted long-term drift. Fortunately, this slow drift is mitigated by repeatedly comparing the atomic reference frequency to the LO and applying corrections each iteration through a control algorithm. This article focuses on the shot-to-shot corrections themselves. To optimize clock performance, it is important to determine whether disturbances on the output are due to variations of the LO that the control loop failed to remove or variations of the reference frequency itself. Some of this can be diagnosed using the output frequency’s Allan deviation (ADEV), the traditional measure of clock performance. However, the ADEV of the corrections reveals somewhat different information, specifically more direct information about all disturbances that the measurement system detects and compensates for, from the LO or elsewhere. In this article: we 1) derive the baseline shot-noise-limited noise floor for this ADEV, 2) validate and adjust for the complexities of our control loop with a computer model, and 3) examine model results and laboratory data that lie on or diverge from the noise floor to understand what divergences reveal about LO and/or clock behavior. Ultimately, we show how to use this corrections-ADEV as a diagnostic to help identify the source of disturbances and drift observed on the clock output.
- 22 February 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (7) , 2590-2601
Open AccessAllan Deviation of Atomic Clock Frequency Corrections: A New Diagnostic Tool for Characterizing Clock Disturbances
As atomic clocks and frequency standards are increasingly operated in situations where they are exposed to environmental disturbances, it becomes more necessary to understand how variations of each clock component impact the clock output, in particular the local oscillator (LO). Most microwave atomic clocks in operation today use quartz crystal LOs with excellent short-term noise variation but large unwanted long-term drift. Fortunately, this slow drift is mitigated by repeatedly comparing the atomic reference frequency to the LO and applying corrections each iteration through a control algorithm. This article focuses on the shot-to-shot corrections themselves. To optimize clock performance, it is important to determine whether disturbances on the output are due to variations of the LO that the control loop failed to remove or variations of the reference frequency itself. Some of this can be diagnosed using the output frequency’s Allan deviation (ADEV), the traditional measure of clock performance. However, the ADEV of the corrections reveals somewhat different information, specifically more direct information about all disturbances that the measurement system detects and compensates for, from the LO or elsewhere. In this article: we 1) derive the baseline shot-noise-limited noise floor for this ADEV, 2) validate and adjust for the complexities of our control loop with a computer model, and 3) examine model results and laboratory data that lie on or diverge from the noise floor to understand what divergences reveal about LO and/or clock behavior. Ultimately, we show how to use this corrections-ADEV as a diagnostic to help identify the source of disturbances and drift observed on the clock output.
- Open Access
- 10 December 2020
- Published by Springer Nature in Research Square
The Deep Space Atomic Clock: the first demonstration of a trapped ion atomic clock in space
Atomic clocks, which lock the frequency of an oscillator to the extremely stable quantized energy levels of atoms, are essential for navigation applications such as deep space exploration1 and the Global Positioning System (GPS)2 and as scientific tools for addressing questions in fundamental physics3,4,5,6. Atomic clocks that can be launched into space are an enabling technology for GPS, but to date have not been applied to deep space navigation and have seen only limited application to scientific questions due to performance constraints imposed by the rigors of space launch and operation7. The invention of methods to electromagnetically trap and cool ions has revolutionized atomic clock performance8,9,10,11,12,13. Terrestrial trapped ion clocks have achieved orders of magnitude improvements in performance over their predecessors and have become a key component in national metrology laboratories13. However, transporting this new technology into space has remained elusive. Here we show the results from the first-ever trapped ion atomic clock to operate in space. Launched in 2019, NASA’s Deep Space Atomic Clock (DSAC) has operated for more than 12 months, demonstrating a short-term fractional frequency stability of between 1 and 2 x 10-13 at 1 second of averaging time (measured on the ground), a long-term stability of 3 x 10-15 at 23 days, and an estimated drift of 3.0(0.7) x 10-16 per day. Each of these exceeds current space clock performance by as much as an order of magnitude14,15,16. We found the DSAC clock to be particularly amenable to the space environment, having low sensitivities to variations in radiation, temperature, and magnetic fields, and we were able to characterize these in detail. This level of space clock performance will enable new types of space navigation. In particular, the DSAC mission has demonstrated a process called one-way navigation whereby signal delay times are measured in-situ making near-real-time deep space probe navigation possible17.
- 10 December 2020
- Published by Springer Nature in Research Square
Open AccessThe Deep Space Atomic Clock: the first demonstration of a trapped ion atomic clock in space
Atomic clocks, which lock the frequency of an oscillator to the extremely stable quantized energy levels of atoms, are essential for navigation applications such as deep space exploration1 and the Global Positioning System (GPS)2 and as scientific tools for addressing questions in fundamental physics3,4,5,6. Atomic clocks that can be launched into space are an enabling technology for GPS, but to date have not been applied to deep space navigation and have seen only limited application to scientific questions due to performance constraints imposed by the rigors of space launch and operation7. The invention of methods to electromagnetically trap and cool ions has revolutionized atomic clock performance8,9,10,11,12,13. Terrestrial trapped ion clocks have achieved orders of magnitude improvements in performance over their predecessors and have become a key component in national metrology laboratories13. However, transporting this new technology into space has remained elusive. Here we show the results from the first-ever trapped ion atomic clock to operate in space. Launched in 2019, NASA’s Deep Space Atomic Clock (DSAC) has operated for more than 12 months, demonstrating a short-term fractional frequency stability of between 1 and 2 x 10-13 at 1 second of averaging time (measured on the ground), a long-term stability of 3 x 10-15 at 23 days, and an estimated drift of 3.0(0.7) x 10-16 per day. Each of these exceeds current space clock performance by as much as an order of magnitude14,15,16. We found the DSAC clock to be particularly amenable to the space environment, having low sensitivities to variations in radiation, temperature, and magnetic fields, and we were able to characterize these in detail. This level of space clock performance will enable new types of space navigation. In particular, the DSAC mission has demonstrated a process called one-way navigation whereby signal delay times are measured in-situ making near-real-time deep space probe navigation possible17.
- 28 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (6) , 950-961
Using the Deep Space Atomic Clock for Navigation and Science
Routine use of one-way radiometric tracking for deep space navigation and radio science is not possible today because spacecraft frequency and time references that use state-of-the-art ultrastable oscillators introduce errors from their intrinsic drift and instability on timescales past 100 s. The Deep Space Atomic Clock (DSAC), currently under development as a NASA Technology Demonstration Mission, is an advanced prototype of a space-flight suitable, mercury-ion atomic clock that can provide an unprecedented frequency and time stability in a space-qualified clock. Indeed, the ground-based results of the DSAC space demonstration unit have already achieved an Allan deviation of 2 × 10 -15 at one day; space performance on this order will enable the use of one-way radiometric signals for deep space navigation and radio science.
- 28 February 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 65 (6) , 950-961
Using the Deep Space Atomic Clock for Navigation and Science
Routine use of one-way radiometric tracking for deep space navigation and radio science is not possible today because spacecraft frequency and time references that use state-of-the-art ultrastable oscillators introduce errors from their intrinsic drift and instability on timescales past 100 s. The Deep Space Atomic Clock (DSAC), currently under development as a NASA Technology Demonstration Mission, is an advanced prototype of a space-flight suitable, mercury-ion atomic clock that can provide an unprecedented frequency and time stability in a space-qualified clock. Indeed, the ground-based results of the DSAC space demonstration unit have already achieved an Allan deviation of 2 × 10 -15 at one day; space performance on this order will enable the use of one-way radiometric signals for deep space navigation and radio science.
- 4 March 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 57 (3) , 629-635
A new trapped ion atomic clock based on 201Hg+
High-resolution spectroscopy has been performed on the ground-state hyperfine transitions in trapped 201Hg+ ions as part of a program to investigate the viability of 201Hg+ for clock applications. Part of the spectroscopy work was directed at magnetic-field-sensitive hyperfine lines with ¿mF =0, which allow accurate Doppler-free measurement of the magnetic field experienced by the trapped ions. Although it is possible to measure Doppler-free magnetic-field-sensitive transitions in the commonly used clock isotope, 199Hg+, it is more difficult. In this paper, we discuss how this 201Hg+ feature may be exploited to produce a more stable clock or one requiring less magnetic shielding in environments with magnetic field fluctuations far in excess of what is normally found in the laboratory. We have also determined that in discharge-lamp-based trapped mercury ion clocks, the optical pumping time for 201Hg+ is about 3 times shorter than that of 199Hg+ This can be used to reduce dead time in the interrogation cycle for these types of clocks, thereby reducing the impact of local oscillator noise aliasing effects.
- 4 March 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 57 (3) , 629-635
A new trapped ion atomic clock based on 201Hg+
High-resolution spectroscopy has been performed on the ground-state hyperfine transitions in trapped 201Hg+ ions as part of a program to investigate the viability of 201Hg+ for clock applications. Part of the spectroscopy work was directed at magnetic-field-sensitive hyperfine lines with ¿mF =0, which allow accurate Doppler-free measurement of the magnetic field experienced by the trapped ions. Although it is possible to measure Doppler-free magnetic-field-sensitive transitions in the commonly used clock isotope, 199Hg+, it is more difficult. In this paper, we discuss how this 201Hg+ feature may be exploited to produce a more stable clock or one requiring less magnetic shielding in environments with magnetic field fluctuations far in excess of what is normally found in the laboratory. We have also determined that in discharge-lamp-based trapped mercury ion clocks, the optical pumping time for 201Hg+ is about 3 times shorter than that of 199Hg+ This can be used to reduce dead time in the interrogation cycle for these types of clocks, thereby reducing the impact of local oscillator noise aliasing effects.
- 30 December 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 55 (12) , 2586-2595
A compensated multi-pole linear ion trap mercury frequency standard for ultra-stable timekeeping
The multi-pole linear ion trap frequency standard (LITS) being developed at the Jet Propulsion Laboratory (JPL) has demonstrated excellent short- and long-term stability. The technology has now demonstrated long-term field operation providing a new capability for timekeeping standards. Recently implemented enhancements have resulted in a record line Q of 5 times 1012 for a room temperature microwave atomic transition and a short-term fractional frequency stability of 5 times 10-14/tau1/2. A scheme for compensating the second order Doppler shift has led to a reduction of the combined sensitivity to the primary LITS systematic effects below 5 times 10-17 fractional frequency. Initial comparisons to JPL's cesium fountain clock show a systematic floor of less than 2 times 10-16. The compensated multi-pole LITS at JPL was operated continuously and unattended for a 9-mo period from October 2006 to July 2007. During that time it was used as the frequency reference for the JPL geodetic receiver known as JPLT, enabling comparisons to any clock used as a reference for an International GNSS Service (IGS) site. Comparisons with the laser-cooled primary frequency standards that reported to the Bureau International des Poids et Mesures (BIPM) over this period show a frequency deviation less than 2.7 times 10-17/day. In the capacity of a stand-alone ultra-stable flywheel, such a standard could be invaluable for long-term timekeeping applications in metrology labs while its methodology and robustness make it ideal for space applications as well.
- 30 December 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 55 (12) , 2586-2595
A compensated multi-pole linear ion trap mercury frequency standard for ultra-stable timekeeping
The multi-pole linear ion trap frequency standard (LITS) being developed at the Jet Propulsion Laboratory (JPL) has demonstrated excellent short- and long-term stability. The technology has now demonstrated long-term field operation providing a new capability for timekeeping standards. Recently implemented enhancements have resulted in a record line Q of 5 times 1012 for a room temperature microwave atomic transition and a short-term fractional frequency stability of 5 times 10-14/tau1/2. A scheme for compensating the second order Doppler shift has led to a reduction of the combined sensitivity to the primary LITS systematic effects below 5 times 10-17 fractional frequency. Initial comparisons to JPL's cesium fountain clock show a systematic floor of less than 2 times 10-16. The compensated multi-pole LITS at JPL was operated continuously and unattended for a 9-mo period from October 2006 to July 2007. During that time it was used as the frequency reference for the JPL geodetic receiver known as JPLT, enabling comparisons to any clock used as a reference for an International GNSS Service (IGS) site. Comparisons with the laser-cooled primary frequency standards that reported to the Bureau International des Poids et Mesures (BIPM) over this period show a frequency deviation less than 2.7 times 10-17/day. In the capacity of a stand-alone ultra-stable flywheel, such a standard could be invaluable for long-term timekeeping applications in metrology labs while its methodology and robustness make it ideal for space applications as well.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23271914,p. 1041-1049
Improvements to JPL's Compensated Multi-Pole Linear Ion Trap Standard and Long-Term Measurements at the 10-16 Level
The Multi-pole Linear Ion Trap Standard (LITS) being developed at the Jet Propulsion Laboratory (JPL) has demonstrated excellent short and long-term stability. The technology has now demonstrated long-term field operation providing a new capability for timekeeping standards. Recently implemented enhancements have resulted in a record room temperature microwave line Q of 5times1012, a short-term fractional frequency stability of 5times10-14/tau1/2 and reduction of the combined sensitivity to the primary LITS systematic effects below 5times10-17 fractional frequency. Initial comparisons to JPL's cesium fountain clock show a systematic floor of less than 2times10-16. The multi-pole LITS at JPL has been operating continuously and unattended since October, 2006 and is used as the frequency reference for the JPL geodetic receiver known as JPLT, enabling comparisons to any clock used as a reference for an IGS site. Initial comparisons with UTC over a 6-month period show a frequency deviation equivalent to less than 2.5times10-17/day. In the capacity of a stand-alone ultra-stable flywheel, such a standard could be invaluable for long-term timekeeping applications in metrology labs while its simplicity and robustness make it ideal for space applications as well.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 23271914,p. 1041-1049
Improvements to JPL's Compensated Multi-Pole Linear Ion Trap Standard and Long-Term Measurements at the 10-16 Level
The Multi-pole Linear Ion Trap Standard (LITS) being developed at the Jet Propulsion Laboratory (JPL) has demonstrated excellent short and long-term stability. The technology has now demonstrated long-term field operation providing a new capability for timekeeping standards. Recently implemented enhancements have resulted in a record room temperature microwave line Q of 5times1012, a short-term fractional frequency stability of 5times10-14/tau1/2 and reduction of the combined sensitivity to the primary LITS systematic effects below 5times10-17 fractional frequency. Initial comparisons to JPL's cesium fountain clock show a systematic floor of less than 2times10-16. The multi-pole LITS at JPL has been operating continuously and unattended since October, 2006 and is used as the frequency reference for the JPL geodetic receiver known as JPLT, enabling comparisons to any clock used as a reference for an IGS site. Initial comparisons with UTC over a 6-month period show a frequency deviation equivalent to less than 2.5times10-17/day. In the capacity of a stand-alone ultra-stable flywheel, such a standard could be invaluable for long-term timekeeping applications in metrology labs while its simplicity and robustness make it ideal for space applications as well.