RPRichard W. Prager

Richard W. Prager

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Richard W. Prager has a total of 178 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    High-resolution ultrasound imaging using unified pixel-based and filtered delay multiply and sum beamforming

    by Hao Guo, Hui-Wen Xie, Guang-Quan Zhou, Nghia Q. Nguyen, Richard W. Prager

    Unified pixel-based (PB) beamforming has previously been implemented for ultrasound imaging. It was shown to offer significant enhancements in lateral resolution compared to conventional dynamic focusing. Yet, there is still interference from clutter and high sidelobe artefacts that limit the the contrast resolution. In this paper, we propose a combination of the unified pixel-based approach with filtered delay multiply and sum (F-DMAS) as a way of further improving the image quality. This hybrid strategy leverages the spatial coherence among signals collected from regions far from the focal depth. As a result, it helps suppress artefacts from the sidelobes and clutter, which can enhance the contrast resolution on the generated image. The new beamformer is evaluated on both simulation and data from an experimental study. The results show that the proposed approach can significantly improve the lateral resolution and image contrast over the unified PB beamformer. Compared to the F-DMAS, it maintains the high contrast resolution while generating uniform brightness over the entire imaging region.


  • Photoacoustic-ultrasonic dual-mode microscopy with local speed-of-sound estimation

    by Wentian Chen, Chao Tao, Nghia Q. Nguyen, Richard W. Prager, Xiaojun Liu

    Synthetic aperture imaging and virtual point detection have been exploited to extend the depth of view of photoacoustic microscopy. The approach is commonly based on a constant assumed sound speed, which reduces image quality. We propose a new, to the best of our knowledge, self-adaptive technique to estimate the speed of sound when integrated with this hybrid strategy. It is accomplished through linear regression between the square of time of flight detected at individual virtual detectors and the square of their horizontal distances on the focal plane. The imaging results show our proposed method can significantly improve the lateral resolution, imaging intensity, and spatial precision for inhomogeneous tissue. (C) 2020 Optical Society of America

  • Open Access

    Mean-Squared Error Beamforming for Coherent Plane-Wave Compounding

    by Nghia Q. Nguyen, Richard W. Prager

    The goal of this paper is to implement a new minimum mean-squared error (MMSE) beamformer for coherent plane-wave compounding. In ultrasound imaging, an beamformer, in the MMSE approach, is usually derived as a multiplication of the minimum variance distortionless response (MVDR) output and a scalar, which is approximated by the coherent factor (CF). Beside the spatial smoothing adopted for estimating the data covariance matrix in MVDR beamforming, this approximation could be another factor that potentially reduces performance of the MMSE. In this paper, we extend the spatial coherent approach that we developed previously for MVDR beamforming, and show how this scalar can be estimated through an array of MVDR outputs. Advances of the proposed MMSE are evaluated on datasets available on PICMUS website. The imaging results show it offers improvements, in terms of spatial and contrast resolution, over the corresponding MVDR and a combination of MVDR beamforming and CF in the literature.


  • Open Access

    A Spatial Coherence Approach to Minimum Variance Beamforming for Plane-Wave Compounding

    by Nghia Q. Nguyen, Richard W. Prager

    A new approach to implement minimum variance distortionless response (MVDR) beamforming is introduced for coherent plane-wave compounding. MVDR requires the covariance matrix of the incoming signal to be estimated and a spatial smoothing approximation is usually adopted to prevent this calculation from being under-constrained. In a new approach, we analyze MVDR as a spatial filter that decorrelates signals received at individual channels before summation. Based on the analysis, we develop two MVDR beamformers without using any spatial smoothing. In the first, MVDR weights are applied to the received signals after accumulating the data over transmits at different angles, while the second involves weighting the data collected in individual transmits and compounding over the transducer elements. In both cases, the covariance matrix is estimated using a set of slightly different combinations of the echo data. We show the sufficient statistic for this estimation can be described by approximating the correlation among the backscattered ultrasound signals to their spatial coherence. Using the van Cittert-Zernike theorem, their statistical similarity is assessed by relating the spatial coherence to the profile of the source intensity. Both spatial-coherence-based MVDR beamformers are evaluated on datasets acquired from simulation, phantom and in vivo studies. Imaging results show that they offer improvements over simple coherent compounding in terms of spatial and contrast resolution. They also outperform other existing MVDR-based methods in the literature that are applied to coherent plane-wave compounding.


  • Improvements to ultrasonic beamformer design and implementation derived from the task-based analytical framework

    by Nghia Q. Nguyen, Richard W. Prager, Michael F. Insana

    The task-based framework, previously developed for beamformer comparison [Nguyen, Prager, and Insana, J. Acoust. Soc. Am. 140, 1048–1059 (2016)], is extended to design a new beamformer with potential applications in breast cancer diagnosis. The beamformer is based on a better approximation of the Bayesian strategy. It is a combination of the Wiener-filtered beamformer and an iterative process that adapts the generated image to specific features of the object. Through numerical studies, the new method is shown to outperform other beamformers drawn from the framework, but at an increase in computational cost. It requires a preprocessing step where the scattering field is segmented into regions with distinct statistical properties. Segmentation errors become a major limitation to the beamformer performance. All the beamformers under investigation are tested using data obtained from an instrumented ultrasound machine. They are implemented using a new time delay calculation, recently developed in the pixel-based beamforming studies presented here, which helps to overcome the challenge posed by the shift-variant nature of the imaging system. The efficacy of each beamformer is evaluated based on the quality of generated images in the context of the task-based framework. The in vitro results confirm the conclusions drawn from the simulations.


  • Open Access

    Ultrasound Pixel-Based Beamforming With Phase Alignments of Focused Beams

    by Nghia Q. Nguyen, Richard W. Prager

    We previously developed unified pixel-based (PB) beamforming to generate high-resolution sonograms, based on field pattern analysis. In this framework, we found that the transmit waveshape away from the focus could be characterized by two spherical pulses. These correspond to the maximal and minimal distances from the imaging point to the active aperture. The beamformer uses this model to select the highest energy signals from backscattered data. A spatiotemporal interpolation formula is used to provide a smooth transition in regions near the focal depth where there is no dominant reflected pulse. In this paper, we show that the unified PB approach is less robust at lower center frequencies. The interpolated data is suboptimal for a longer transmit waveshape. As a result, the spatial resolution at the focal depth is lower than that in other regions. By further exploring the field pattern, we propose a beamformer that is more robust to variations in beamwidth. The new method, named coherent PB beamforming, aligns and compounds the pulse data directly in the transition regions. In simulation and phantom studies, the coherent PB approach is shown to outperform the unified PB approach in spatial resolution. It helps regain optimal resolution at the focal depth while still maintaining good image quality in other regions. We also demonstrate the new method on in vivo data where its improvements over the unified PB method are demonstrated on scanned objects with a more complicated structure.


  • Minimum variance beamformers for coherent plane-wave compounding

    by Nghia Q. Nguyen, Richard W. Prager


  • Open Access

    Minimum Variance Approaches to Ultrasound Pixel-Based Beamforming

    by Nghia Q. Nguyen, Richard W. Prager

    We analyze the principles underlying minimum variance distortionless response (MVDR) beamforming in order to integrate it into a pixel-based algorithm. There is a challenge posed by the low echo signal-to-noise ratio (eSNR) when calculating beamformer contributions at pixels far away from the beam centreline. Together with the well-known scarcity of samples for covariance matrix estimation, this reduces the beamformer performance and degrades the image quality. To address this challenge, we implement the MVDR algorithm in two different ways. First, we develop the conventional minimum variance pixel-based (MVPB) beamformer that performs the MVDR after the pixel-based superposition step. This involves a combination of methods in the literature, extended over multiple transmits to increase the eSNR. Then we propose the coherent MVPB beamformer, where the MVDR is applied to data within individual transmits. Based on pressure field analysis, we develop new algorithms to improve the data alignment and matrix estimation, and hence overcome the low-eSNR issue. The methods are demonstrated on data acquired with an ultrasound open platform. The results show the coherent MVPB beamformer substantially outperforms the conventional MVPB in a series of experiments, including phantom and in vivo studies. Compared to the unified pixel-based beamformer, the newest delay-and-sum algorithm in [1], the coherent MVPB performs well on regions that conform to the diffuse scattering assumptions on which the minimum variance principles are based. It produces less good results for parts of the image that are dominated by specular reflections.


  • A task-based analytical framework for ultrasonic beamformer comparison

    by Nghia Q. Nguyen, Richard W. Prager, Michael F. Insana

    A task-based approach is employed to develop an analytical framework for ultrasound beamformer design and evaluation. In this approach, a Bayesian ideal-observer provides an idealized starting point and a way to measure information loss in practical beamformer designs. Different approximations of this ideal strategy are shown to lead to popular beamformers in the literature, including the matched filter, minimum variance (MV), and Wiener filter (WF) beamformers. Analysis of the approximations indicates that the WF beamformer should outperform the MV approach, especially in low echo signal-to-noise conditions. The beamformers are applied to five typical tasks from the BIRADS lexicon. Their performance is evaluated based on ability to discriminate idealized malignant and benign features. The numerical results show the advantages of the WF over the MV technique in general; although performance varies predictably in some contrast-limited tasks because of the model modifications required for the MV algorithm to avoid ill-conditioning.