Kevin B. Thurbide
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kevin B. Thurbide has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
Ernest Darko
University of Calgary
7 shared publicationsChristine Mah
Department of Chemistry, University of Calgary, 2500 University Dr., NW, Calgary, Alberta T2N 1N4, Canada
3 shared publicationsEmmanuel A. Nai
Department of Chemistry University of Calgary Calgary Alberta Canada
3 shared publicationsJianmin Zhang
Department of Chemistry, University of Calgary, 2500 University Drive, N.W. Calgary, Alberta T2N 1N4, Canada
3 shared publicationsKaylan H. McKelvie
University of Calgary
3 shared publicationsAdrian G. Clark
Department of Chemistry, University of Calgary, Calgary, Alberta T2N 1N4, Canada
2 shared publications
Latest Publications
- 25 February 2026
- Published by Canadian Science Publishing in Canadian Journal of Chemistry
Characteristics of sulfolane as a novel stationary phase in supercritical fluid chromatography
Sulfolane (C 4 H 8 SO 2 ) is a small, polar, aprotic, cyclic molecule largely used as a solvent in oil and gas production for its interesting selectivity towards aromatic compounds. Here, sulfolane is examined as a novel stationary phase for use in capillary column supercritical fluid chromatography with flame ionization detection (SFC-FID). A 2 m × 250 µm stainless steel capillary was found to be optimal for retaining the sulfolane phase and achieving practical retention times for most analytes. Under typical conditions of 65 °C and 120 atm, the dynamic solubility of sulfolane in the supercritical CO 2 mobile phase was measured to be only 0.6 g/L. This translated into minimal system detector noise for various mobile phase pressure and temperature settings that produced a moderate CO 2 density of 0.4 g/mL or lower. In this way, the phase normally provided good performance and very little background interference in the FID over several hours of operation. Due to its thickness (∼4 µm) the phase produced plate heights about 10-fold larger than optimal capillary SFC performance, but with an elevated sample capacity near 50 µg of injected analyte. Good retention and peak shape were obtained for various polar and non-polar analytes. Conversely, organic acids and bases yielded poor peak shape and low recovery on the column. Adding water to the sulfolane coating produced significant changes in analyte selectivity. Compared to a longer conventional SFC column, the relatively short sulfolane column demonstrated high selectivity towards aromatic analytes over saturates in the analysis of a gasoline sample. Results indicate that sulfolane might be a potentially useful alternative stationary phase for the selective SFC analysis of aromatics in various petroleum samples.
- 25 February 2026
- Published by Canadian Science Publishing in Canadian Journal of Chemistry
Characteristics of sulfolane as a novel stationary phase in supercritical fluid chromatography
Sulfolane (C 4 H 8 SO 2 ) is a small, polar, aprotic, cyclic molecule largely used as a solvent in oil and gas production for its interesting selectivity towards aromatic compounds. Here, sulfolane is examined as a novel stationary phase for use in capillary column supercritical fluid chromatography with flame ionization detection (SFC-FID). A 2 m × 250 µm stainless steel capillary was found to be optimal for retaining the sulfolane phase and achieving practical retention times for most analytes. Under typical conditions of 65 °C and 120 atm, the dynamic solubility of sulfolane in the supercritical CO 2 mobile phase was measured to be only 0.6 g/L. This translated into minimal system detector noise for various mobile phase pressure and temperature settings that produced a moderate CO 2 density of 0.4 g/mL or lower. In this way, the phase normally provided good performance and very little background interference in the FID over several hours of operation. Due to its thickness (∼4 µm) the phase produced plate heights about 10-fold larger than optimal capillary SFC performance, but with an elevated sample capacity near 50 µg of injected analyte. Good retention and peak shape were obtained for various polar and non-polar analytes. Conversely, organic acids and bases yielded poor peak shape and low recovery on the column. Adding water to the sulfolane coating produced significant changes in analyte selectivity. Compared to a longer conventional SFC column, the relatively short sulfolane column demonstrated high selectivity towards aromatic analytes over saturates in the analysis of a gasoline sample. Results indicate that sulfolane might be a potentially useful alternative stationary phase for the selective SFC analysis of aromatics in various petroleum samples.
- 4 November 2024
- Published by Wiley in Journal of Separation Science
- Vol. 47 (21) , e70008
A Dual Column pH Switchable Water Stationary Phase System for Separation Control in Supercritical Fluid Chromatography
A dual column system comprised of a pH switchable water stationary phase column and a conventional non‐polar capillary column is introduced for use in Supercritical Fluid Chromatography (SFC). By removing or adding NH4OH to the system hydration source, the water stationary phase pH can be rapidly switched between acidic (measured at pH∼3) and basic (measured at pH∼9) in seconds, while the operating character of the conventional column is unchanged. This switch modulates the velocity of ionizable analytes about 20‐fold in the system, whereas non‐ionizable analytes are not affected. In this way, the retention time of acids and/or bases can be reproducibly altered (<1% RSD; n = 3) in SFC separations. As a result, analyte selectivity and resolution can be readily controlled during analyses. For example, a selectivity reversal (alpha from 0.4 to 1.6) and a resolution increase (from 0 to 13) are demonstrated. Rapid stationary phase pH switching also allows multiple acids, bases, and/or neutral analytes to be determined simultaneously. Applications demonstrate that this method can greatly simplify complex mixture analysis in SFC by helping to separate target analytes from interfering matrix components.
- 4 November 2024
- Published by Wiley in Journal of Separation Science
- Vol. 47 (21) , e70008
A Dual Column pH Switchable Water Stationary Phase System for Separation Control in Supercritical Fluid Chromatography
A dual column system comprised of a pH switchable water stationary phase column and a conventional non‐polar capillary column is introduced for use in Supercritical Fluid Chromatography (SFC). By removing or adding NH4OH to the system hydration source, the water stationary phase pH can be rapidly switched between acidic (measured at pH∼3) and basic (measured at pH∼9) in seconds, while the operating character of the conventional column is unchanged. This switch modulates the velocity of ionizable analytes about 20‐fold in the system, whereas non‐ionizable analytes are not affected. In this way, the retention time of acids and/or bases can be reproducibly altered (<1% RSD; n = 3) in SFC separations. As a result, analyte selectivity and resolution can be readily controlled during analyses. For example, a selectivity reversal (alpha from 0.4 to 1.6) and a resolution increase (from 0 to 13) are demonstrated. Rapid stationary phase pH switching also allows multiple acids, bases, and/or neutral analytes to be determined simultaneously. Applications demonstrate that this method can greatly simplify complex mixture analysis in SFC by helping to separate target analytes from interfering matrix components.
- 25 April 2024
- Published by Springer Nature in Chromatographia
- Vol. 87 (6) , 363-373
Flameless Operating Mode for Improved Multiple Flame Photometric Detection in Gas Chromatography
- 25 April 2024
- Published by Springer Nature in Chromatographia
- Vol. 87 (6) , 363-373
Flameless Operating Mode for Improved Multiple Flame Photometric Detection in Gas Chromatography
- 6 December 2023
- Published by Springer Nature in Chromatographia
- Vol. 87 (2) , 87-93
A Method to Externally Adjust the Column Length in Gas Chromatography Using a Water Stationary Phase
- 6 December 2023
- Published by Springer Nature in Chromatographia
- Vol. 87 (2) , 87-93
A Method to Externally Adjust the Column Length in Gas Chromatography Using a Water Stationary Phase
- 1 December 2023
- Published by Canadian Science Publishing in Canadian Journal of Chemistry
- Vol. 101 (12) , 933-942
Characteristics of a novel alkali flame ionization detector as an air sensor for volatile organo-nitrogen compounds
A novel alkali flame ionization detector (AFID) is introduced and characterized for use as an air sensor (i.e., without chromatographic separation) for organo-nitrogen compounds. Using a planar channeled quartz design, a simple, lightweight architecture for the portable device is presented, which yields sensitive and selective response toward nitrogen-containing analytes. For instance, the AFID sensor offers a detection limit of 30 pg N/s and a selectivity for nitrogen response over carbon of nearly two orders of magnitude. Further, nitrogen response is linear over the 1000-fold range of concentrations investigated. Relative to a flame photometric detector (FPD) device also used in a sensor mode, the AFID is observed to provide 100 times greater S/N values for nitrogen analytes with a nitrogen-to-carbon selectivity that is about 15 times larger. When using the AFID and FPD sensors in tandem, it is found that the response ratio of the simultaneous signals generated by each produces characteristic values that more clearly identify the presence or absence of nitrogen in unknown analytes. The AFID sensor was used to detect organo-nitrogen analytes in several samples, and results indicate that it could be a useful approach for portable air sensing of nitrogen compounds.
- 1 December 2023
- Published by Canadian Science Publishing in Canadian Journal of Chemistry
- Vol. 101 (12) , 933-942
Characteristics of a novel alkali flame ionization detector as an air sensor for volatile organo-nitrogen compounds
A novel alkali flame ionization detector (AFID) is introduced and characterized for use as an air sensor (i.e., without chromatographic separation) for organo-nitrogen compounds. Using a planar channeled quartz design, a simple, lightweight architecture for the portable device is presented, which yields sensitive and selective response toward nitrogen-containing analytes. For instance, the AFID sensor offers a detection limit of 30 pg N/s and a selectivity for nitrogen response over carbon of nearly two orders of magnitude. Further, nitrogen response is linear over the 1000-fold range of concentrations investigated. Relative to a flame photometric detector (FPD) device also used in a sensor mode, the AFID is observed to provide 100 times greater S/N values for nitrogen analytes with a nitrogen-to-carbon selectivity that is about 15 times larger. When using the AFID and FPD sensors in tandem, it is found that the response ratio of the simultaneous signals generated by each produces characteristic values that more clearly identify the presence or absence of nitrogen in unknown analytes. The AFID sensor was used to detect organo-nitrogen analytes in several samples, and results indicate that it could be a useful approach for portable air sensing of nitrogen compounds.
- 4 August 2023
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1278, 341686
A novel switchable water stationary phase for supercritical fluid chromatography
- 4 August 2023
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1278, 341686
A novel switchable water stationary phase for supercritical fluid chromatography
- 8 October 2022
- Published by Springer Nature in Chromatographia
- Vol. 85 (12) , 1087-1096
Supercritical Fluid Chromatography of Organic Bases Using a Modified Water Stationary Phase
- 8 October 2022
- Published by Springer Nature in Chromatographia
- Vol. 85 (12) , 1087-1096
Supercritical Fluid Chromatography of Organic Bases Using a Modified Water Stationary Phase
- 6 January 2022
- Published by Springer Nature in Chromatographia
- Vol. 85 (2) , 105-113
Selective Separation of Polar Unsaturated Organics Using a Water Stationary Phase in Gas Chromatography
- 6 January 2022
- Published by Springer Nature in Chromatographia
- Vol. 85 (2) , 105-113
Selective Separation of Polar Unsaturated Organics Using a Water Stationary Phase in Gas Chromatography
- 1 January 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1189, 339254
Sulfolane as a novel stationary phase for analytical separations by gas chromatography
- 1 January 2022
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1189, 339254
Sulfolane as a novel stationary phase for analytical separations by gas chromatography
- 1 October 2020
- Published by Canadian Science Publishing in Canadian Journal of Chemistry
- Vol. 98 (10) , 623-629
Characteristics of a novel on-line micro pressurized liquid extraction method
A novel on-line micro pressurized liquid extraction (μPLE) method is introduced, which directly interfaces miniaturized solid sample preparation with HPLC for fast analysis. The technique employs rapid heating to remove analytes from 5–10 mg samples in typically 20–40 s using only about 300 μL of solvent. The resulting extract is then internally transferred to an HPLC injector for chromatographic analysis. Results show that good analyte recoveries can be achieved, similar to conventional PLE and off-line μPLE approaches, without manual sample handling. For example, 103% ± 3% (n = 4) of the acetylsalicylic acid present in pharmaceutical tablets was extracted into methanol after 20 s at 180 °C. Further, 105% ± 9% (n = 4) of the caffeine present in a green tea sample was extracted into methanol after 40 s at 275 °C. Typical time to analysis was about 95 s total for most samples, and solvents could also be easily alternated during trials to increase extract selectivity. The on-line μPLE system was applied to the extraction of model PAHs from a biochar matrix and was found to extract 97% ± 5% (n = 4) of anthracene present in the sample after a 30 s static and 60 s dynamic extraction at 220 °C. This yield is much better than results obtained by previous approaches and is attributed to the small size, high temperature, low thermal mass, and dynamic flow of the system. Findings indicate that the on-line μPLE system can greatly assist in such extractions and provide a useful method for rapidly preparing solid samples for analysis using little solvent.
- 1 October 2020
- Published by Canadian Science Publishing in Canadian Journal of Chemistry
- Vol. 98 (10) , 623-629
Characteristics of a novel on-line micro pressurized liquid extraction method
A novel on-line micro pressurized liquid extraction (μPLE) method is introduced, which directly interfaces miniaturized solid sample preparation with HPLC for fast analysis. The technique employs rapid heating to remove analytes from 5–10 mg samples in typically 20–40 s using only about 300 μL of solvent. The resulting extract is then internally transferred to an HPLC injector for chromatographic analysis. Results show that good analyte recoveries can be achieved, similar to conventional PLE and off-line μPLE approaches, without manual sample handling. For example, 103% ± 3% (n = 4) of the acetylsalicylic acid present in pharmaceutical tablets was extracted into methanol after 20 s at 180 °C. Further, 105% ± 9% (n = 4) of the caffeine present in a green tea sample was extracted into methanol after 40 s at 275 °C. Typical time to analysis was about 95 s total for most samples, and solvents could also be easily alternated during trials to increase extract selectivity. The on-line μPLE system was applied to the extraction of model PAHs from a biochar matrix and was found to extract 97% ± 5% (n = 4) of anthracene present in the sample after a 30 s static and 60 s dynamic extraction at 220 °C. This yield is much better than results obtained by previous approaches and is attributed to the small size, high temperature, low thermal mass, and dynamic flow of the system. Findings indicate that the on-line μPLE system can greatly assist in such extractions and provide a useful method for rapidly preparing solid samples for analysis using little solvent.