Sergej A. Kostromin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sergej A. Kostromin has a total of 128 co-authors. Here are the top co-authors by number of shared publications:
- Hamlet Khodzhibagiyan
Joint Institute for Nuclear Research
4 shared publications E. V. Samsonov
3 shared publicationsN. A. Morozov
3 shared publications- Vladimir V. Borisov
Joint Institute for Nuclear Research, Dubna, Russia
3 shared publications - A. V. Butenko
Joint Institute for Nuclear Research
2 shared publications - Aleksei Melnikov
Institute for Nuclear Research
2 shared publications
Latest Publications
- 1 November 2024
- Published by Pleiades Publishing Ltd in JETP Letters
- Vol. 120 (10) , 779-787
Compensation of the Effect of the Imperfection of the Nuclotron/JINR Lattice on the Proton Polarization near an Integer Spin Resonance (Brief Review)
A number of open questions remain in the manipulation of the spins of colliding beams, which is a key aspect in the operation of polarized beam colliders such as the Nuclotron-based ion collider facility (JINR, Dubna, Russia) and the electron ion collider (BNL, United States). The spin transparency regime, which is the only realistic regime to control the deuteron polarization, has not yet been approved experimentally. With the existing configuration of the JINR accelerator complex, a pilot spin transparency experiment could be performed on a proton beam in the Nuclotron synchrotron. The dynamics of the proton beam polarization during the fast crossing of spin resonance guided by spin navigators based on regular orbit-steerer dipoles has been analyzed in this work. A scheme has been designed to compensate the coherent action of Nuclotron lattice imperfections on spin. In this scheme, the spin field induced by lattice imperfections is determined from the adiabatic deviation of spins in the resonance region, taking into account the synchrotron energy modulation. Integer-resonance strengths can be compensated down to the limits conditioned by orbital beam emittances. The numerical simulation of the proposed spin compensator has confirmed that the spin transparency regime in an imperfect Nuclotron lattice with a strongly distorted closed orbit can be experimentally verified.
- 1 November 2024
- Published by Pleiades Publishing Ltd in JETP Letters
- Vol. 120 (10) , 779-787
Compensation of the Effect of the Imperfection of the Nuclotron/JINR Lattice on the Proton Polarization near an Integer Spin Resonance (Brief Review)
A number of open questions remain in the manipulation of the spins of colliding beams, which is a key aspect in the operation of polarized beam colliders such as the Nuclotron-based ion collider facility (JINR, Dubna, Russia) and the electron ion collider (BNL, United States). The spin transparency regime, which is the only realistic regime to control the deuteron polarization, has not yet been approved experimentally. With the existing configuration of the JINR accelerator complex, a pilot spin transparency experiment could be performed on a proton beam in the Nuclotron synchrotron. The dynamics of the proton beam polarization during the fast crossing of spin resonance guided by spin navigators based on regular orbit-steerer dipoles has been analyzed in this work. A scheme has been designed to compensate the coherent action of Nuclotron lattice imperfections on spin. In this scheme, the spin field induced by lattice imperfections is determined from the adiabatic deviation of spins in the resonance region, taking into account the synchrotron energy modulation. Integer-resonance strengths can be compensated down to the limits conditioned by orbital beam emittances. The numerical simulation of the proposed spin compensator has confirmed that the spin transparency regime in an imperfect Nuclotron lattice with a strongly distorted closed orbit can be experimentally verified.
- 11 September 2023
- Published by Pleiades Publishing Ltd in JETP Letters
- Vol. 118 (6) , 387-394
Proton-Spin-Flipping System Based on Orbit-Steerer Dipoles in the Nuclotron/JINR Operating at the γG = 7 Spin Resonance
We propose a system to produce multiple spin-reversals of a polarized proton beam based on orbit-steerer dipoles already installed in the Nuclotron, a superconducting synchrotron at the Joint Institute for Nuclear Research, when the latter operates in the spin-transparency regime. The beam momentum of 3.54 GeV/c corresponds to the integer spin-resonance γG = 7. We report the results of numerical simulation of the proton spin dynamics pertinent to the acceleration up to γG = 7, including the adiabatic capture of spins by navigators and the subsequent multiple spin flips. A feasibility of the pilot experiment to verify our approach with the current magnetic lattice of the Nuclotron is discussed. To preserve the beam polarization during the crossing of integer resonances we propose to employ intentional resonance-strength enhancements effected by controlled variations of the beam orbit during acceleration.
- 11 September 2023
- Published by Pleiades Publishing Ltd in JETP Letters
- Vol. 118 (6) , 387-394
Proton-Spin-Flipping System Based on Orbit-Steerer Dipoles in the Nuclotron/JINR Operating at the γG = 7 Spin Resonance
We propose a system to produce multiple spin-reversals of a polarized proton beam based on orbit-steerer dipoles already installed in the Nuclotron, a superconducting synchrotron at the Joint Institute for Nuclear Research, when the latter operates in the spin-transparency regime. The beam momentum of 3.54 GeV/c corresponds to the integer spin-resonance γG = 7. We report the results of numerical simulation of the proton spin dynamics pertinent to the acceleration up to γG = 7, including the adiabatic capture of spins by navigators and the subsequent multiple spin flips. A feasibility of the pilot experiment to verify our approach with the current magnetic lattice of the Nuclotron is discussed. To preserve the beam polarization during the crossing of integer resonances we propose to employ intentional resonance-strength enhancements effected by controlled variations of the beam orbit during acceleration.
- Open Access
- 1 March 2021
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 16 (03) , T03003
Heavy ion collider NICA at JINR
Main scientific goal of the NICA/MPD project (Nuclotron-based Ion Collider fAcility/ Multi Purpose Detector) under construction at JINR (Dubna) is exploration of the phase diagram of strongly interacting matter in the region of high compression. The planned experimental program includes studies of possible signs of the phase transitions and critical phenomena in heavy ion (up to Au) collisions at the center-of-mass energies up to 11 GeV/u. The collider experiment provides optimum conditions for efficient energy scan measurements. Attainment of the required average luminosity of the order of 1027 cm-2·s-1 for such physics experiment faces several accelerator physics and technology challenges. Contrary to high energy colliders, the luminosity of NICA case will be mostly limited by the Laslett tune shift, while the beam-beam tune shift parameter will be negligibly small. Flexible operational procedures for the beam storage and short bunch formation have been developed to provide maximum peak luminosity over wide energy range. Beam cooling is critical to counteract luminosity decay due to intra-beam scattering. NICA collider design addresses these issues and satisfies all the requirements for the colliding beams experiments.
- 1 March 2021
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 16 (03) , T03003
Open AccessHeavy ion collider NICA at JINR
Main scientific goal of the NICA/MPD project (Nuclotron-based Ion Collider fAcility/ Multi Purpose Detector) under construction at JINR (Dubna) is exploration of the phase diagram of strongly interacting matter in the region of high compression. The planned experimental program includes studies of possible signs of the phase transitions and critical phenomena in heavy ion (up to Au) collisions at the center-of-mass energies up to 11 GeV/u. The collider experiment provides optimum conditions for efficient energy scan measurements. Attainment of the required average luminosity of the order of 1027 cm-2·s-1 for such physics experiment faces several accelerator physics and technology challenges. Contrary to high energy colliders, the luminosity of NICA case will be mostly limited by the Laslett tune shift, while the beam-beam tune shift parameter will be negligibly small. Flexible operational procedures for the beam storage and short bunch formation have been developed to provide maximum peak luminosity over wide energy range. Beam cooling is critical to counteract luminosity decay due to intra-beam scattering. NICA collider design addresses these issues and satisfies all the requirements for the colliding beams experiments.
- Open Access
- 27 July 2020
- Published by Pleiades Publishing Ltd in Physics of Particles and Nuclei Letters
- Vol. 17 (4) , 447-452
Optimization the Optical Structure of the NICA Collider
The optimization of the optical structure of the NICA Collider is presented. The Collider optics settings are given for a working point of 9.44/9.44 and a bare gold nuclei beam with energies of 1, 3, and 4.5 GeV/u. The dynamic aperture simulation and optimization results are given. The tolerance of the magnetic field errors for the Collider structural elements and the closed orbit adjustment precision are discussed.
- 27 July 2020
- Published by Pleiades Publishing Ltd in Physics of Particles and Nuclei Letters
- Vol. 17 (4) , 447-452
Open AccessOptimization the Optical Structure of the NICA Collider
The optimization of the optical structure of the NICA Collider is presented. The Collider optics settings are given for a working point of 9.44/9.44 and a bare gold nuclei beam with energies of 1, 3, and 4.5 GeV/u. The dynamic aperture simulation and optimization results are given. The tolerance of the magnetic field errors for the Collider structural elements and the closed orbit adjustment precision are discussed.
- 25 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-6
Production and Test Status of the Superconducting Magnets for the NICA Project and the SIS100 Synchrotron
NICA is an international project - accelerator collider complex under construction at the Joint Institute for Nuclear Research in Dubna. The facility is aimed at providing collider experiments with heavy ions up to gold in the center of mass energy from 4 to 11 GeV/u and an average luminosity up to 1e-27 cm $^-2$ s $^{-1}$ for Au $^{79+}$ . Collision experiments with polarized deuterons and protons are also foreseen. The facility includes two injector chains, a new superconducting booster synchrotron, the existing 6 AGeV superconducting synchrotron Nuclotron, and a new superconducting collider consisting of two rings, each 503 m in circumference. The planned FAIR synchrotron SIS100 has to deliver high intensity beams for the FAIR project at GSI, Darmstadt. This machine will use fast-cycling 4 T/s magnets with a magnetic field up to 2 T. The NICA booster synchrotron, the NICA collider and the heavy ion synchrotron SIS100 are based on iron-dominated window frame-type magnets with a hollow superconductor winding analogous to the Nuclotron magnet. Progress in the manufacturing and testing of the NICA magnets and the SIS100 superconducting magnets is presented.- 25 February 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 29 (5) , 1-6
Production and Test Status of the Superconducting Magnets for the NICA Project and the SIS100 Synchrotron
NICA is an international project - accelerator collider complex under construction at the Joint Institute for Nuclear Research in Dubna. The facility is aimed at providing collider experiments with heavy ions up to gold in the center of mass energy from 4 to 11 GeV/u and an average luminosity up to 1e-27 cm $^-2$ s $^{-1}$ for Au $^{79+}$ . Collision experiments with polarized deuterons and protons are also foreseen. The facility includes two injector chains, a new superconducting booster synchrotron, the existing 6 AGeV superconducting synchrotron Nuclotron, and a new superconducting collider consisting of two rings, each 503 m in circumference. The planned FAIR synchrotron SIS100 has to deliver high intensity beams for the FAIR project at GSI, Darmstadt. This machine will use fast-cycling 4 T/s magnets with a magnetic field up to 2 T. The NICA booster synchrotron, the NICA collider and the heavy ion synchrotron SIS100 are based on iron-dominated window frame-type magnets with a hollow superconductor winding analogous to the Nuclotron magnet. Progress in the manufacturing and testing of the NICA magnets and the SIS100 superconducting magnets is presented.- 30 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-5
Magnetic Measurements of the NICA Booster Superferric Magnets
Nuclotron-based Ion Collider fAcility (NICA) is a new accelerator collider complex currently under construction at the Joint Institute for Nuclear Research (JINR) in Dubna, Russia. The facility includes a new superconducting booster synchrotron whose layout includes 40 dipole and 48 quadrupole superferric magnets. Booster magnets are under serial production, assembling and testing at the new test facility at JINR, Dubna. The designs of NICA magnets are based on the Nuclotron magnet design. The dipole magnets for the NICA booster have a length of 2.14 m, an aperture of 128/165 mm, and a curved yoke with bending radius of 14.1 m. Two quadrupole magnets are connected together to form a doublet. Measurement of the magnetic field parameters are assumed for each booster magnet. 80% of the dipole magnets and 10% of the doublets have successfully passed the tests. We present the cold test results that were obtained from the magnetic measurements of dipole magnets and compare them with the requirements of the specification. Preliminary results of cold magnetic measurements of the first serial doublets are summarized here.
- 30 January 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-5
Magnetic Measurements of the NICA Booster Superferric Magnets
Nuclotron-based Ion Collider fAcility (NICA) is a new accelerator collider complex currently under construction at the Joint Institute for Nuclear Research (JINR) in Dubna, Russia. The facility includes a new superconducting booster synchrotron whose layout includes 40 dipole and 48 quadrupole superferric magnets. Booster magnets are under serial production, assembling and testing at the new test facility at JINR, Dubna. The designs of NICA magnets are based on the Nuclotron magnet design. The dipole magnets for the NICA booster have a length of 2.14 m, an aperture of 128/165 mm, and a curved yoke with bending radius of 14.1 m. Two quadrupole magnets are connected together to form a doublet. Measurement of the magnetic field parameters are assumed for each booster magnet. 80% of the dipole magnets and 10% of the doublets have successfully passed the tests. We present the cold test results that were obtained from the magnetic measurements of dipole magnets and compare them with the requirements of the specification. Preliminary results of cold magnetic measurements of the first serial doublets are summarized here.
- 27 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-5
Testing of the Superconducting Magnets for the SIS100 Synchrotron
The SIS100, a novel heavy ion synchrotron, is the main accelerator of the FAIR complex (Facility for Antiproton and Ion Research), which is currently being constructed in Darmstadt, Germany. Over 400 superconducting magnets have been contracted either at industry or by collaboration partners. In order to fulfil the requirements for quality assurance, the magnets will be intensively tested at ambient and cryogenic conditions. The testing campaign considers mechanical dimension control (including the height of the yoke's gap), electrical tests, and measurements of the magnetic field induction. Two new test facilities were built for the sake of superconducting magnet testing. The first facility is located at the GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany. The object is constructed to provide a comprehensive testing program dedicated to series dipole cryomodules. The second test facility is located at the Joint Institute for Nuclear Research (JINR), Dubna, Russian Federation, where quadrupole and corrector magnets are going to be tested. This paper presents the status report concerning the magnet production, testing strategy, and capability and extent of development of the test stations.
- 27 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 28 (3) , 1-5
Testing of the Superconducting Magnets for the SIS100 Synchrotron
The SIS100, a novel heavy ion synchrotron, is the main accelerator of the FAIR complex (Facility for Antiproton and Ion Research), which is currently being constructed in Darmstadt, Germany. Over 400 superconducting magnets have been contracted either at industry or by collaboration partners. In order to fulfil the requirements for quality assurance, the magnets will be intensively tested at ambient and cryogenic conditions. The testing campaign considers mechanical dimension control (including the height of the yoke's gap), electrical tests, and measurements of the magnetic field induction. Two new test facilities were built for the sake of superconducting magnet testing. The first facility is located at the GSI Helmholtzzentrum für Schwerionenforschung GmbH, Darmstadt, Germany. The object is constructed to provide a comprehensive testing program dedicated to series dipole cryomodules. The second test facility is located at the Joint Institute for Nuclear Research (JINR), Dubna, Russian Federation, where quadrupole and corrector magnets are going to be tested. This paper presents the status report concerning the magnet production, testing strategy, and capability and extent of development of the test stations.
- 6 December 2016
- Published by Pleiades Publishing Ltd in Physics of Particles and Nuclei Letters
- Vol. 13 (7) , 855-861
Measurement of the magnetic-field parameters of the NICA Booster dipole magnet
- 6 December 2016
- Published by Pleiades Publishing Ltd in Physics of Particles and Nuclei Letters
- Vol. 13 (7) , 855-861
Measurement of the magnetic-field parameters of the NICA Booster dipole magnet
- 24 June 2014
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 59 (6) , 917-924
C235-V3 cyclotron for a proton therapy center to be installed in the hospital complex of radiation medicine (Dimitrovgrad)
Proton therapy is an effective method of treating oncologic diseases. In Russia, construction of several centers for proton and ion therapy is slated for the years to come. A proton therapy center in...
- 24 June 2014
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 59 (6) , 917-924
C235-V3 cyclotron for a proton therapy center to be installed in the hospital complex of radiation medicine (Dimitrovgrad)
Proton therapy is an effective method of treating oncologic diseases. In Russia, construction of several centers for proton and ion therapy is slated for the years to come. A proton therapy center in...
- 6 January 2012
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 57 (1) , 106-112
Beam dynamics in a C253-V3 cyclotron for proton therapy
In recent years, oncologic diseases have become a severe issue in developed countries. Proton therapy is viewed as one of the most efficient methods of treating oncologic diseases. The results of...
- 6 January 2012
- Published by Pleiades Publishing Ltd in Technical Physics
- Vol. 57 (1) , 106-112
Beam dynamics in a C253-V3 cyclotron for proton therapy
In recent years, oncologic diseases have become a severe issue in developed countries. Proton therapy is viewed as one of the most efficient methods of treating oncologic diseases. The results of...