Lukas Koch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Lukas Koch has a total of 1000 co-authors. Here are the top co-authors by number of shared publications:
- Kevin Scott McFarland
University of Rochester
36 shared publications M. Smy
University of California Irvine, Irvine, CA 92697
35 shared publicationsM. Tzanov
Louisiana State University, Baton Rouge, LA 70803
35 shared publications- P. N. Ratoff
Cockcroft Institute
35 shared publications T. Kutter
Louisiana State University, Baton Rouge, LA 70803
35 shared publications- Takayuki Hasegawa
High Energy Accelerator Research Organization (KEK)
35 shared publications
Latest Publications
- Open Access
- 1 August 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (08) , P08018
Charge readout electronics for the DUNE horizontal drift far detector: design and performance in ProtoDUNE-HD
DUNE (Deep Underground Neutrino Experiment) is a long-baseline neutrino oscillation experiment currently under construction, whose far detectors will be the largest liquid argon time projection chambers ever built. This detector design calls for custom-built cryogenic front-end electronics to meet its performance requirements. This paper describes the charge readout electronics that will be used in the DUNE horizontal drift (HD) far detector and presents performance results using data from the ProtoDUNE-HD detector, a 770 ton liquid argon time projection chamber operated at the CERN Neutrino Platform in 2024 that served as the final prototype of the DUNE HD design.
- 1 August 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (08) , P08018
Open AccessCharge readout electronics for the DUNE horizontal drift far detector: design and performance in ProtoDUNE-HD
DUNE (Deep Underground Neutrino Experiment) is a long-baseline neutrino oscillation experiment currently under construction, whose far detectors will be the largest liquid argon time projection chambers ever built. This detector design calls for custom-built cryogenic front-end electronics to meet its performance requirements. This paper describes the charge readout electronics that will be used in the DUNE horizontal drift (HD) far detector and presents performance results using data from the ProtoDUNE-HD detector, a 770 ton liquid argon time projection chamber operated at the CERN Neutrino Platform in 2024 that served as the final prototype of the DUNE HD design.
- Open Access
- 3 June 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (11)
Measurement of exclusive π + -argon interactions using ProtoDUNE-SP
We present the measurement of π + -argon inelastic cross sections using the ProtoDUNE single-phase liquid argon time projection chamber in the incident π + kinetic energy range of 500–800 MeV in multiple exclusive channels (absorption, charge exchange, and the remaining inelastic interactions). The results of this analysis are important inputs to simulations of liquid argon neutrino experiments such as the Deep Underground Neutrino Experiment and the Short Baseline Neutrino program at Fermi National Accelerator Laboratory. They will be employed to improve the modeling of final state interactions within neutrino event generators used by these experiments, as well as the modeling of π + -argon secondary interactions within the liquid argon. This is the first measurement of π + -argon absorption at this kinetic energy range as well as the first ever measurement of π + -argon charge exchange.
- 3 June 2026
- Published by American Physical Society (APS) in Physical Review D
- Vol. 113 (11)
Open AccessMeasurement of exclusive π + -argon interactions using ProtoDUNE-SP
We present the measurement of π + -argon inelastic cross sections using the ProtoDUNE single-phase liquid argon time projection chamber in the incident π + kinetic energy range of 500–800 MeV in multiple exclusive channels (absorption, charge exchange, and the remaining inelastic interactions). The results of this analysis are important inputs to simulations of liquid argon neutrino experiments such as the Deep Underground Neutrino Experiment and the Short Baseline Neutrino program at Fermi National Accelerator Laboratory. They will be employed to improve the modeling of final state interactions within neutrino event generators used by these experiments, as well as the modeling of π + -argon secondary interactions within the liquid argon. This is the first measurement of π + -argon absorption at this kinetic energy range as well as the first ever measurement of π + -argon charge exchange.
- 28 April 2026
- Published by International Association for Statistical Computing in Journal of Data Science, Statistics, and Visualisation
- Vol. 6 (2)
Plotting correlated data
A very common task in data visualization is to plot many data points with some measured y-value as a function of fixed x-values. Uncertainties on the y-values are typically presented as vertical error bars that represent either a Frequentist confidence interval or Bayesian credible interval for each data point. Most of the time, these error bars represent a 68% confidence/credibility level, which leads to the intuition that a model fits the data reasonably well if its prediction lies within the error bars of roughly two thirds of the data points. Unfortunately, this and other intuitions no longer work when the uncertainties of the data points are correlated. In those cases, the error bars only show the square root of the diagonal elements of the covariance matrix. If the covariance has non negligible off-diagonal elements, we simply do not have enough information in the plot to judge whether a drawn model line agrees well with the data or not. In this paper we will demonstrate this problem and discuss ways to add more information to the plots to make it easier to judge the agreement between the data and some model prediction in the plot, as well as glean some insight where the model might be deficient. This is done by adding information about the correlation between neighbouring bins, and showing the contribution of the first principal component of the uncertainties.
- 28 April 2026
- Published by International Association for Statistical Computing in Journal of Data Science, Statistics, and Visualisation
- Vol. 6 (2)
Plotting correlated data
A very common task in data visualization is to plot many data points with some measured y-value as a function of fixed x-values. Uncertainties on the y-values are typically presented as vertical error bars that represent either a Frequentist confidence interval or Bayesian credible interval for each data point. Most of the time, these error bars represent a 68% confidence/credibility level, which leads to the intuition that a model fits the data reasonably well if its prediction lies within the error bars of roughly two thirds of the data points. Unfortunately, this and other intuitions no longer work when the uncertainties of the data points are correlated. In those cases, the error bars only show the square root of the diagonal elements of the covariance matrix. If the covariance has non negligible off-diagonal elements, we simply do not have enough information in the plot to judge whether a drawn model line agrees well with the data or not. In this paper we will demonstrate this problem and discuss ways to add more information to the plots to make it easier to judge the agreement between the data and some model prediction in the plot, as well as glean some insight where the model might be deficient. This is done by adding information about the correlation between neighbouring bins, and showing the contribution of the first principal component of the uncertainties.
- Open Access
- 9 February 2026
- Published by Springer Nature in Communications Physics
- Vol. 9 (1)
Probing Earth’s missing potassium using the antimatter signature of geoneutrinos
- 9 February 2026
- Published by Springer Nature in Communications Physics
- Vol. 9 (1)
Open AccessProbing Earth’s missing potassium using the antimatter signature of geoneutrinos
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , P01040
Covering unknown correlations in Bayesian priors by inflating uncertainties
Bayesian analyses require that all variable model parameters are given a prior probability distribution. This can pose a challenge for analyses where multiple experiments are combined if these experiments use different parameterisations for their nuisance parameters. If the parameters in the two models describe exactly the same physics, they should be 100% correlated in the prior. If the parameters describe independent physics, they should be uncorrelated. But if they describe related or overlapping physics, it is not trivial to determine what the joint prior distribution should look like. Even if the priors for each experiment are well motivated, the unknown correlations between them can have unintended consequences for the posterior probability of the parameters of interest, potentially leading to underestimated uncertainties. In this paper we show that it is possible to choose a prior parametrisation that ensures conservative posterior uncertainties for the parameters of interest under some very general assumptions.
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , P01040
Covering unknown correlations in Bayesian priors by inflating uncertainties
Bayesian analyses require that all variable model parameters are given a prior probability distribution. This can pose a challenge for analyses where multiple experiments are combined if these experiments use different parameterisations for their nuisance parameters. If the parameters in the two models describe exactly the same physics, they should be 100% correlated in the prior. If the parameters describe independent physics, they should be uncorrelated. But if they describe related or overlapping physics, it is not trivial to determine what the joint prior distribution should look like. Even if the priors for each experiment are well motivated, the unknown correlations between them can have unintended consequences for the posterior probability of the parameters of interest, potentially leading to underestimated uncertainties. In this paper we show that it is possible to choose a prior parametrisation that ensures conservative posterior uncertainties for the parameters of interest under some very general assumptions.
- Open Access
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , P01010
Muon tracking in a LiquidO opaque scintillator detector
LiquidO is an innovative radiation detector concept. The core idea is to exploit stochastic light confinement in a highly scattering medium to self-segment the detector volume. In this paper, we demonstrate event-by-event muon tracking in a LiquidO opaque scintillator detector prototype. The detector consists of a 30 mm cubic scintillator volume instrumented with 64 wavelength-shifting fibres arranged in an 8 × 8 grid with a 3.2 mm pitch and read out by silicon photomultipliers. A wax-based opaque scintillator with a scattering length of approximately 0.5 mm is used. The tracking performance of this LiquidO detector is characterised with cosmic-ray muons and the position resolution is demonstrated to be 450 μm per row of fibres. These results highlight the potential of LiquidO opaque scintillator detectors to achieve fine spatial resolution, enabling precise particle tracking and imaging.
- 1 January 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (01) , P01010
Open AccessMuon tracking in a LiquidO opaque scintillator detector
LiquidO is an innovative radiation detector concept. The core idea is to exploit stochastic light confinement in a highly scattering medium to self-segment the detector volume. In this paper, we demonstrate event-by-event muon tracking in a LiquidO opaque scintillator detector prototype. The detector consists of a 30 mm cubic scintillator volume instrumented with 64 wavelength-shifting fibres arranged in an 8 × 8 grid with a 3.2 mm pitch and read out by silicon photomultipliers. A wax-based opaque scintillator with a scattering length of approximately 0.5 mm is used. The tracking performance of this LiquidO detector is characterised with cosmic-ray muons and the position resolution is demonstrated to be 450 μm per row of fibres. These results highlight the potential of LiquidO opaque scintillator detectors to achieve fine spatial resolution, enabling precise particle tracking and imaging.
- Open Access
- 2 June 2025
- Published by Elsevier in Astroparticle Physics
- Vol. 172
COCOA: A compact Compton camera for astrophysical observation of MeV-scale gamma rays
- 2 June 2025
- Published by Elsevier in Astroparticle Physics
- Vol. 172
Open AccessCOCOA: A compact Compton camera for astrophysical observation of MeV-scale gamma rays
- Open Access
- 12 May 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (9)
Supernova pointing capabilities of DUNE
The determination of the direction of a stellar core collapse via its neutrino emission is crucial for the identification of the progenitor for a multimessenger follow-up. A highly effective method of reconstructing supernova directions within the Deep Underground Neutrino Experiment (DUNE) is introduced. The supernova neutrino pointing resolution is studied by simulating and reconstructing electron-neutrino charged-current absorption on Ar 40 and elastic scattering of neutrinos on electrons. Procedures to reconstruct individual interactions, including a newly developed technique called “brems flipping,” as well as the burst direction from an ensemble of interactions are described. Performance of the burst direction reconstruction is evaluated for supernovae happening at a distance of 10 kpc for a specific supernova burst flux model. The pointing resolution is found to be 3.4 degrees at 68% coverage for a perfect interaction-channel classification and a fiducial mass of 40 kton, and 6.6 degrees for a 10 kton fiducial mass respectively. Assuming a 4% rate of charged-current interactions being misidentified as elastic scattering, DUNE’s burst pointing resolution is found to be 4.3 degrees (8.7 degrees) at 68% coverage. Published by the American Physical Society 2025
- 12 May 2025
- Published by American Physical Society (APS) in Physical Review D
- Vol. 111 (9)
Open AccessSupernova pointing capabilities of DUNE
The determination of the direction of a stellar core collapse via its neutrino emission is crucial for the identification of the progenitor for a multimessenger follow-up. A highly effective method of reconstructing supernova directions within the Deep Underground Neutrino Experiment (DUNE) is introduced. The supernova neutrino pointing resolution is studied by simulating and reconstructing electron-neutrino charged-current absorption on Ar 40 and elastic scattering of neutrinos on electrons. Procedures to reconstruct individual interactions, including a newly developed technique called “brems flipping,” as well as the burst direction from an ensemble of interactions are described. Performance of the burst direction reconstruction is evaluated for supernovae happening at a distance of 10 kpc for a specific supernova burst flux model. The pointing resolution is found to be 3.4 degrees at 68% coverage for a perfect interaction-channel classification and a fiducial mass of 40 kton, and 6.6 degrees for a 10 kton fiducial mass respectively. Assuming a 4% rate of charged-current interactions being misidentified as elastic scattering, DUNE’s burst pointing resolution is found to be 4.3 degrees (8.7 degrees) at 68% coverage. Published by the American Physical Society 2025
- Open Access
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , E05001
ERRATUM: Post-hoc regularisation of unfolded cross-section measurements
ERRATUM: Post-hoc regularisation of unfolded cross-section measurements, Koch, Lukas ERRATUM: Post-hoc regularisation of unfolded cross-section measurements, Koch, Lukas
- 1 May 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (05) , E05001
Open AccessERRATUM: Post-hoc regularisation of unfolded cross-section measurements
ERRATUM: Post-hoc regularisation of unfolded cross-section measurements, Koch, Lukas ERRATUM: Post-hoc regularisation of unfolded cross-section measurements, Koch, Lukas