Richard Hayden Jones
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Richard Hayden Jones has a total of 85 co-authors. Here are the top co-authors by number of shared publications:
- Alexander Varshavsky
Tianqiao and Chrissy Chen Institute for Neuroscience, Division of Biology and Biological Engineering, California Institute of Technology
2 shared publications Christopher S. Brower
Division of Biology, California Institute of Technology, Pasadena, CA 91125
2 shared publicationsAlexander A Morgan
Department of Pediatrics, Stanford University School of Medicine, Stanford, CA 94305, USA
1 shared publicationAlexis S. Davis
Division of Neonatal and Developmental Medicine, Department of Pediatrics, Stanford University School of Medicine, Palo Alto, CA, 94304, USA
1 shared publicationAllison Park
Department of Computer Science, Stanford University, Stanford, California, United States of America
1 shared publicationAmanda Regodón Wallin
Karolinska Institutet, Stockholm, Sweden
1 shared publication
Latest Publications
- 1 September 2026
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 23 (10) , 1895-1903
A Road Map for Addressing Incidental Findings in Pediatric Radiology
- 1 September 2026
- Published by Elsevier in Journal of the American College of Radiology
- Vol. 23 (10) , 1895-1903
A Road Map for Addressing Incidental Findings in Pediatric Radiology
- Open Access
- 25 November 2022
- Published by Springer Nature in Cureus
- Vol. 14 (11) , e31897
COVID-19 Diagnosis on Chest Radiograph Using Artificial Intelligence
Background: The coronavirus disease 2019 (COVID-19) pandemic has disrupted the world since 2019, causing significant morbidity and mortality in developed and developing countries alike. Although substantial resources have been diverted to developing diagnostic, preventative, and treatment measures, disparities in the availability and efficacy of these tools vary across countries. We seek to assess the ability of commercial artificial intelligence (AI) technology to diagnose COVID-19 by analyzing chest radiographs. Materials and methods: Chest radiographs taken from symptomatic patients within two days of polymerase chain reaction (PCR) tests were assessed for COVID-19 infection by board-certified radiologists and commercially available AI software. Sixty patients with negative and 60 with positive COVID reverse transcription-polymerase chain reaction (RT-PCR) tests were chosen. Results were compared against results of the PCR test for accuracy and statistically analyzed by receiver operating characteristic (ROC) curves along with area under the curve (AUC) values. Results: A total of 120 chest radiographs (60 positive and 60 negative RT-PCR tests) radiographs were analyzed. The AI software performed significantly better than chance (p = 0.001) and did not differ significantly from the radiologist ROC curve (p = 0.78). Conclusion: Commercially available AI software was not inferior compared with trained radiologists in accurately identifying COVID-19 cases by analyzing radiographs. While RT-PCR testing remains the standard, current advances in AI help correctly analyze chest radiographs to diagnose COVID-19 infection.
- 25 November 2022
- Published by Springer Nature in Cureus
- Vol. 14 (11) , e31897
Open AccessCOVID-19 Diagnosis on Chest Radiograph Using Artificial Intelligence
Background: The coronavirus disease 2019 (COVID-19) pandemic has disrupted the world since 2019, causing significant morbidity and mortality in developed and developing countries alike. Although substantial resources have been diverted to developing diagnostic, preventative, and treatment measures, disparities in the availability and efficacy of these tools vary across countries. We seek to assess the ability of commercial artificial intelligence (AI) technology to diagnose COVID-19 by analyzing chest radiographs. Materials and methods: Chest radiographs taken from symptomatic patients within two days of polymerase chain reaction (PCR) tests were assessed for COVID-19 infection by board-certified radiologists and commercially available AI software. Sixty patients with negative and 60 with positive COVID reverse transcription-polymerase chain reaction (RT-PCR) tests were chosen. Results were compared against results of the PCR test for accuracy and statistically analyzed by receiver operating characteristic (ROC) curves along with area under the curve (AUC) values. Results: A total of 120 chest radiographs (60 positive and 60 negative RT-PCR tests) radiographs were analyzed. The AI software performed significantly better than chance (p = 0.001) and did not differ significantly from the radiologist ROC curve (p = 0.78). Conclusion: Commercially available AI software was not inferior compared with trained radiologists in accurately identifying COVID-19 cases by analyzing radiographs. While RT-PCR testing remains the standard, current advances in AI help correctly analyze chest radiographs to diagnose COVID-19 infection.
- Open Access
- 28 August 2021
- Published by Elsevier in Radiology Case Reports
- Vol. 16 (11) , 3341-3345
Successful reduction of recalcitrant ileocolic intussusception with a double-balloon-tipped catheter that prevents air leaks and catheter expulsion
- 28 August 2021
- Published by Elsevier in Radiology Case Reports
- Vol. 16 (11) , 3341-3345
Open AccessSuccessful reduction of recalcitrant ileocolic intussusception with a double-balloon-tipped catheter that prevents air leaks and catheter expulsion
- Open Access
- 15 October 2020
- Published by Egyptian Knowledge Bank in Annals of Pediatric Surgery
- Vol. 16 (1) , 1-6
Case report: Amyand hernia reincarnate and the utility of computed tomography
Background: An Amyand hernia is a rare condition in which the vermiform appendix follows the bowel as it bulges through the inguinal canal. Originally described by Claudius Amyand in 1735 in an 11-year-old boy who had a pin in the appendix (Philos Trans R Soc Lond. 1735;39:329–36), we describe here the first case with CT depicting all components of Dr. Amyand’s original case. Case presentation: A 10-year-old boy presented with right lower quadrant and groin pain. CT imaging revealed a retained metallic foreign body perforating the appendix, acute appendicitis, and an Amyand hernia. A laparoscopic attempt at reduction failed due to tethering by the needle and inflammation of the hernia sac, requiring an open inguinal exploration and excision of the hernia sac. The patient was discharged on postoperative day 2 with plans for delayed hernia repair. Conclusions: CT is a crucial diagnostic test for surgical decision-making in Amyand hernias. In this case, it accurately classified the hernia and led to anticipation of unsuccessful laparoscopic hernia reduction. Management in the setting of foreign body and perforation includes appendectomy and tissue herniorrhaphy with delayed formal inguinal hernia repair after inflammation has subsided.
- 15 October 2020
- Published by Egyptian Knowledge Bank in Annals of Pediatric Surgery
- Vol. 16 (1) , 1-6
Open AccessCase report: Amyand hernia reincarnate and the utility of computed tomography
Background: An Amyand hernia is a rare condition in which the vermiform appendix follows the bowel as it bulges through the inguinal canal. Originally described by Claudius Amyand in 1735 in an 11-year-old boy who had a pin in the appendix (Philos Trans R Soc Lond. 1735;39:329–36), we describe here the first case with CT depicting all components of Dr. Amyand’s original case. Case presentation: A 10-year-old boy presented with right lower quadrant and groin pain. CT imaging revealed a retained metallic foreign body perforating the appendix, acute appendicitis, and an Amyand hernia. A laparoscopic attempt at reduction failed due to tethering by the needle and inflammation of the hernia sac, requiring an open inguinal exploration and excision of the hernia sac. The patient was discharged on postoperative day 2 with plans for delayed hernia repair. Conclusions: CT is a crucial diagnostic test for surgical decision-making in Amyand hernias. In this case, it accurately classified the hernia and led to anticipation of unsuccessful laparoscopic hernia reduction. Management in the setting of foreign body and perforation includes appendectomy and tissue herniorrhaphy with delayed formal inguinal hernia repair after inflammation has subsided.
- 21 June 2019
- Published by Springer Nature in Journal of Perinatology
- Vol. 39 (8) , 1111-1117
Prenatally diagnosed omphalocele: characteristics associated with adverse neonatal outcomes
Objective To characterize factors associated with adverse neonatal outcomes in prenatally diagnosed omphalocele cases. Study design Prenatally diagnosed omphalocele cases at a single referral center from 1 January 2009 to 31 December 2017 were retrospectively reviewed. Clinical variables and antenatal imaging measurements were collected. Associations between prenatal and neonatal characteristics and the adverse outcome of death or prolonged length of stay (LOS) were analyzed. Results Out of 63 fetal cases, 33 were live-born, > 50% had other anomalies, and neonatal mortality was 12%. Adverse outcomes were associated with neonatal variables, including lower median 1-min Apgar score, initial mechanical ventilation, and late-onset sepsis, but not approach to omphalocele closure. With multivariate analysis, death or prolonged LOS was associated only with low lung volumes by fetal MRI (OR 34 (3–422), p = 0.006). Conclusion Low lung volumes by fetal MRI were associated with death or prolonged LOS in neonates with prenatally diagnosed omphalocele and may guide clinicians with counseling families.
- 21 June 2019
- Published by Springer Nature in Journal of Perinatology
- Vol. 39 (8) , 1111-1117
Prenatally diagnosed omphalocele: characteristics associated with adverse neonatal outcomes
Objective To characterize factors associated with adverse neonatal outcomes in prenatally diagnosed omphalocele cases. Study design Prenatally diagnosed omphalocele cases at a single referral center from 1 January 2009 to 31 December 2017 were retrospectively reviewed. Clinical variables and antenatal imaging measurements were collected. Associations between prenatal and neonatal characteristics and the adverse outcome of death or prolonged length of stay (LOS) were analyzed. Results Out of 63 fetal cases, 33 were live-born, > 50% had other anomalies, and neonatal mortality was 12%. Adverse outcomes were associated with neonatal variables, including lower median 1-min Apgar score, initial mechanical ventilation, and late-onset sepsis, but not approach to omphalocele closure. With multivariate analysis, death or prolonged LOS was associated only with low lung volumes by fetal MRI (OR 34 (3–422), p = 0.006). Conclusion Low lung volumes by fetal MRI were associated with death or prolonged LOS in neonates with prenatally diagnosed omphalocele and may guide clinicians with counseling families.
- Top Cited PapersOpen Access
- 27 November 2018
- Published by Public Library of Science (PLoS) in PLOS Medicine
- Vol. 15 (11) , e1002699
Deep-learning-assisted diagnosis for knee magnetic resonance imaging: Development and retrospective validation of MRNet
Magnetic resonance imaging (MRI) of the knee is the preferred method for diagnosing knee injuries. However, interpretation of knee MRI is time-intensive and subject to diagnostic error and variability. An automated system for interpreting knee MRI could prioritize high-risk patients and assist clinicians in making diagnoses. Deep learning methods, in being able to automatically learn layers of features, are well suited for modeling the complex relationships between medical images and their interpretations. In this study we developed a deep learning model for detecting general abnormalities and specific diagnoses (anterior cruciate ligament [ACL] tears and meniscal tears) on knee MRI exams. We then measured the effect of providing the model’s predictions to clinical experts during interpretation. Our dataset consisted of 1,370 knee MRI exams performed at Stanford University Medical Center between January 1, 2001, and December 31, 2012 (mean age 38.0 years; 569 [41.5%] female patients). The majority vote of 3 musculoskeletal radiologists established reference standard labels on an internal validation set of 120 exams. We developed MRNet, a convolutional neural network for classifying MRI series and combined predictions from 3 series per exam using logistic regression. In detecting abnormalities, ACL tears, and meniscal tears, this model achieved area under the receiver operating characteristic curve (AUC) values of 0.937 (95% CI 0.895, 0.980), 0.965 (95% CI 0.938, 0.993), and 0.847 (95% CI 0.780, 0.914), respectively, on the internal validation set. We also obtained a public dataset of 917 exams with sagittal T1-weighted series and labels for ACL injury from Clinical Hospital Centre Rijeka, Croatia. On the external validation set of 183 exams, the MRNet trained on Stanford sagittal T2-weighted series achieved an AUC of 0.824 (95% CI 0.757, 0.892) in the detection of ACL injuries with no additional training, while an MRNet trained on the rest of the external data achieved an AUC of 0.911 (95% CI 0.864, 0.958). We additionally measured the specificity, sensitivity, and accuracy of 9 clinical experts (7 board-certified general radiologists and 2 orthopedic surgeons) on the internal validation set both with and without model assistance. Using a 2-sided Pearson’s chi-squared test with adjustment for multiple comparisons, we found no significant differences between the performance of the model and that of unassisted general radiologists in detecting abnormalities. General radiologists achieved significantly higher sensitivity in detecting ACL tears (p-value = 0.002; q-value = 0.019) and significantly higher specificity in detecting meniscal tears (p-value = 0.003; q-value = 0.019). Using a 1-tailed t test on the change in performance metrics, we found that providing model predictions significantly increased clinical experts’ specificity in identifying ACL tears (p-value < 0.001; q-value = 0.006). The primary limitations of our study include lack of surgical ground truth and the small size of the panel of clinical experts. Our deep learning model can rapidly generate accurate clinical pathology classifications of knee MRI exams from both internal and external datasets. Moreover, our results support the assertion that deep learning models can improve the performance of clinical experts during medical imaging interpretation. Further research is needed to validate the model prospectively and to determine its utility in the clinical setting.
- 27 November 2018
- Published by Public Library of Science (PLoS) in PLOS Medicine
- Vol. 15 (11) , e1002699
Top Cited PapersOpen AccessDeep-learning-assisted diagnosis for knee magnetic resonance imaging: Development and retrospective validation of MRNet
Magnetic resonance imaging (MRI) of the knee is the preferred method for diagnosing knee injuries. However, interpretation of knee MRI is time-intensive and subject to diagnostic error and variability. An automated system for interpreting knee MRI could prioritize high-risk patients and assist clinicians in making diagnoses. Deep learning methods, in being able to automatically learn layers of features, are well suited for modeling the complex relationships between medical images and their interpretations. In this study we developed a deep learning model for detecting general abnormalities and specific diagnoses (anterior cruciate ligament [ACL] tears and meniscal tears) on knee MRI exams. We then measured the effect of providing the model’s predictions to clinical experts during interpretation. Our dataset consisted of 1,370 knee MRI exams performed at Stanford University Medical Center between January 1, 2001, and December 31, 2012 (mean age 38.0 years; 569 [41.5%] female patients). The majority vote of 3 musculoskeletal radiologists established reference standard labels on an internal validation set of 120 exams. We developed MRNet, a convolutional neural network for classifying MRI series and combined predictions from 3 series per exam using logistic regression. In detecting abnormalities, ACL tears, and meniscal tears, this model achieved area under the receiver operating characteristic curve (AUC) values of 0.937 (95% CI 0.895, 0.980), 0.965 (95% CI 0.938, 0.993), and 0.847 (95% CI 0.780, 0.914), respectively, on the internal validation set. We also obtained a public dataset of 917 exams with sagittal T1-weighted series and labels for ACL injury from Clinical Hospital Centre Rijeka, Croatia. On the external validation set of 183 exams, the MRNet trained on Stanford sagittal T2-weighted series achieved an AUC of 0.824 (95% CI 0.757, 0.892) in the detection of ACL injuries with no additional training, while an MRNet trained on the rest of the external data achieved an AUC of 0.911 (95% CI 0.864, 0.958). We additionally measured the specificity, sensitivity, and accuracy of 9 clinical experts (7 board-certified general radiologists and 2 orthopedic surgeons) on the internal validation set both with and without model assistance. Using a 2-sided Pearson’s chi-squared test with adjustment for multiple comparisons, we found no significant differences between the performance of the model and that of unassisted general radiologists in detecting abnormalities. General radiologists achieved significantly higher sensitivity in detecting ACL tears (p-value = 0.002; q-value = 0.019) and significantly higher specificity in detecting meniscal tears (p-value = 0.003; q-value = 0.019). Using a 1-tailed t test on the change in performance metrics, we found that providing model predictions significantly increased clinical experts’ specificity in identifying ACL tears (p-value < 0.001; q-value = 0.006). The primary limitations of our study include lack of surgical ground truth and the small size of the panel of clinical experts. Our deep learning model can rapidly generate accurate clinical pathology classifications of knee MRI exams from both internal and external datasets. Moreover, our results support the assertion that deep learning models can improve the performance of clinical experts during medical imaging interpretation. Further research is needed to validate the model prospectively and to determine its utility in the clinical setting.
- Open Access
- 1 August 2018
- Published by SAGE Publications in Journal of Investigative Medicine
- Vol. 66 (6) , 980-985
Lumbar Spine Bone Mineral Density Z-Score Discrepancies by Dual X-Ray Absorptiometry Do Not Predict Vertebral Fractures in Children
Dual X-ray absorptiometry (DXA) remains the most common mode of bone mineral density (BMD) evaluation. In adults, presence of a lumbar spine (LS) BMD T-score discrepancy (>1 SD difference between adjacent vertebrae) can indicate a vertebral fracture. In children, however, the clinical significance of such discrepancies is unknown. We conducted a retrospective study to evaluate the association between LS DXA and LS morphology to elucidate the clinical significance of an LS BMD Z-score discrepancy. We identified 360 DXA scans performed between September 2014 and May 2016 in patients 5–18 years of age. DXA scans were cross-referenced against available LS radiographs and vertebral fracture assessment (VFA) within the 6 months preceding or following a DXA scan. After excluding 44 DXA scans because of spinal hardware, incomplete DXA, or repeat scans, 316 DXA scans were included; 81 (25.6%) had either an LS radiograph or a VFA. Twenty-five of 81 patients (30.9%) had >1 SD difference between adjacent vertebrae in LS BMD Z-score. Two of these 25 patients (8%) had a lumbar vertebral fracture documented by a spine radiograph. Of the remaining 56 patients who did not have a discrepancy >1 SD, 6 patients (11%) had a lumbar vertebral fracture. Discrepancies in LS BMD Z-scores were not associated with lumbar vertebral fractures and, in the absence of fractures, likely represented vertebral developmental variants in children whose skeletons are still growing. Therefore, it does not appear justified to recommend further imaging based solely on the results of a DXA scan without clinically meaningful indications.
- 1 August 2018
- Published by SAGE Publications in Journal of Investigative Medicine
- Vol. 66 (6) , 980-985
Open AccessLumbar Spine Bone Mineral Density Z-Score Discrepancies by Dual X-Ray Absorptiometry Do Not Predict Vertebral Fractures in Children
Dual X-ray absorptiometry (DXA) remains the most common mode of bone mineral density (BMD) evaluation. In adults, presence of a lumbar spine (LS) BMD T-score discrepancy (>1 SD difference between adjacent vertebrae) can indicate a vertebral fracture. In children, however, the clinical significance of such discrepancies is unknown. We conducted a retrospective study to evaluate the association between LS DXA and LS morphology to elucidate the clinical significance of an LS BMD Z-score discrepancy. We identified 360 DXA scans performed between September 2014 and May 2016 in patients 5–18 years of age. DXA scans were cross-referenced against available LS radiographs and vertebral fracture assessment (VFA) within the 6 months preceding or following a DXA scan. After excluding 44 DXA scans because of spinal hardware, incomplete DXA, or repeat scans, 316 DXA scans were included; 81 (25.6%) had either an LS radiograph or a VFA. Twenty-five of 81 patients (30.9%) had >1 SD difference between adjacent vertebrae in LS BMD Z-score. Two of these 25 patients (8%) had a lumbar vertebral fracture documented by a spine radiograph. Of the remaining 56 patients who did not have a discrepancy >1 SD, 6 patients (11%) had a lumbar vertebral fracture. Discrepancies in LS BMD Z-scores were not associated with lumbar vertebral fractures and, in the absence of fractures, likely represented vertebral developmental variants in children whose skeletons are still growing. Therefore, it does not appear justified to recommend further imaging based solely on the results of a DXA scan without clinically meaningful indications.
- 1 November 2017
- Published by Elsevier in Clinical Radiology
- Vol. 72 (11) , 995.e1-995.e9
Small hepatocellular carcinomas displayed as a ring enhancing mass on arterial phase MRI in the chronically diseased liver
- 1 November 2017
- Published by Elsevier in Clinical Radiology
- Vol. 72 (11) , 995.e1-995.e9
Small hepatocellular carcinomas displayed as a ring enhancing mass on arterial phase MRI in the chronically diseased liver
- Open Access
- 1 January 2016
- Published by Open Access Pub in Journal of Colon And Rectal Cancer
- Vol. 1 (1) , 45-54
Taller Haustral Folds in the Proximal Colon: A Potential Factor Contributing to Interval Colorectal Cancer
- 1 January 2016
- Published by Open Access Pub in Journal of Colon And Rectal Cancer
- Vol. 1 (1) , 45-54
Open AccessTaller Haustral Folds in the Proximal Colon: A Potential Factor Contributing to Interval Colorectal Cancer