Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Valeria Garzarelli has a total of 60 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Mechanochemical upcycling of pyrolyzed cork waste into biocompatible superhydrophobic PDMS sponges for passive oil–water separation

    by Antonella Iaia, Roberta Di Maio, Clara Piccirillo, Valeria Garzarelli, Concetta Nobile, Alessia Rinaldi, Viviana Vergaro, Elisabetta Primiceri, Antonio Grieco, Maria Serena Chiriacò, et al.


  • Development of an Automated Edge-Detection Tool for Robust Cell Biology Assays

    by Alfredo De Cillis, Valeria Garzarelli, Alessia Foscarini, Maria Serena Chiriacò, Francesco Ferrara

  • Open Access

    Mechanochemical upcycling of pyrolyzed cork waste into biocompatible superhydrophobic PDMS sponges for passive oil–water separation

    by Antonella Iaia, Roberta Di Maio, Clara Piccirillo, Valeria Garzarelli, Concetta Nobile, Viviana Vergaro, Elisabetta Primiceri, Antonio Grieco, Maria Serena Chiriacò, Antonio Turco, et al.

    Oil spill pollution and oily wastewater remain persistent threats to aquatic ecosystems, driving the need for environmentally safe and high-performance separation materials. Here, we report a sustainable PDMS-based composite incorporating graphitic carbon derived from cork industrial waste via pyrolysis and solvent-free mechanochemical processing.pCork–PDMS sponges fabricated through solvent-free mechanochemical activation, hard templating, and microwave-assisted curing form robust and recyclable three-dimensional porous networks. The optimal formulation (2 wt% pCork) exhibits superhydrophobic and superoleophilic behavior (water contact angle >150°, oil contact angle ≈0°), rapid and near-quantitative oil uptake, outstanding selectivity for both floating and submerged oils, and high reusability over repeated regeneration cycles, including in complex real seawater matrices.Benchmarking against representative state-of-the-art materials reveals superior volume absorption capacities compared to commonly studied carbon aerogels and graphene-based composites. Critically, rigorous biocompatibility assays under both direct and indirect exposure demonstrate high cell viability and the absence of cytotoxic effects, underscoring the environmental safety of the sorbent itself.Collectively, these findings establish a new materials strategy for hazardous oil–water remediation based on mechanochemically treated, biomass-derived graphitic carbon, demonstrating a rare and benchmarked combination of oil–water interfacial selectivity, rapid uptake kinetics, high absorption capacity, mechanical durability, and biological safety, while shifting PDMS sponge design away from conventional synthetic nanocarbons toward environmentally safe, circular-economy feedstocks.

  • Open Access

    3D-printed barriers with machine learning powered image analysis for enhanced wound healing assays

    by Alfredo De Cillis, Valeria Garzarelli, Alessia Foscarini, Giuseppe Gigli, Antonio Turco, Elisabetta Primiceri, Maria Serena Chiriacò, Francesco Ferrara


  • Open Access

    A Microfluidic-Based Sensing Platform for Rapid Quality Control on Target Cells from Bioreactors

    by Alessia Foscarini, Fabio Romano, Valeria Garzarelli, Antonio Turco, Alessandro Paolo Bramanti, Iolena Tarantini, Francesco Ferrara, Paolo Visconti, Giuseppe Gigli, Maria Serena Chiriacò

    We investigated the design and characterization of a Lab-On-a-Chip (LoC) cell detection system primarily designed to support immunotherapy in cancer treatment. Immunotherapy uses Chimeric Antigen Receptors (CARs) and T Cell Receptors (TCRs) to fight cancer, engineering the response of the immune system. In recent years, it has emerged as a promising strategy for personalized cancer treatment. However, it requires bioreactor-based cell culture expansion and manual quality control (QC) of the modified cells, which is time-consuming, labour-intensive, and prone to errors. The miniaturized LoC device for automated QC demonstrated here is simple, has a low cost, and is reliable. Its final target is to become one of the building blocks of an LoC for immunotherapy, which would take the place of present labs and manual procedures to the benefit of throughput and affordability. The core of the system is a commercial, on-chip-integrated capacitive sensor managed by a microcontroller capable of sensing cells as accurately measured charge variations. The hardware is based on standardized components, which makes it suitable for mass manufacturing. Moreover, unlike in other cell detection solutions, no external AC source is required. The device has been characterized with a cell line model selectively labelled with gold nanoparticles to simulate its future use in bioreactors in which labelling can apply to successfully engineered CAR-T-cells. Experiments were run both in the air—free drop with no microfluidics—and in the channel, where the fluid volume was considerably lower than in the drop. The device showed good sensitivity even with a low number of cells—around 120, compared with the 107 to 108 needed per kilogram of body weight—which is desirable for a good outcome of the expansion process. Since cell detection is needed in several contexts other than immunotherapy, the usefulness of this LoC goes potentially beyond the scope considered here.


  • Open Access

    TITAN Project: Microfluidic and Sensing Tools for Immunotherapy

    by Maria Serena Chiriacò, Elisabetta Primiceri, Antonio Turco, Valeria Garzarelli, Giulia Siciliano, Alessia Foscarini, Ahmed Alsadig, Annunziata Carbonara, Benedetta Stampone, Gianluca Trotta, et al.

    The TITAN project aims to improve immunotherapy, targeting the efficiency of methods to obtain genetically engineered T cells. Immunotherapy has achieved great success in clinical trials, but it is currently very expensive in terms of time required for analysis, reagents, and samples. TITAN aims to the continuous sampling of critical quality attributes, in order to quickly recognize deviations from the desired range and take appropriate corrective actions on process parameters for an optimal outcome. To achieve its aims, TITAN is currently developing microfluidic and sensing tools for the accurate and efficient real-time monitoring of the T cells amplification process.

  • Open Access

    Ultrasensitive qPCR platform for rapid detection of bacterial contamination of raw biological samples at the point of care

    by Valeria Garzarelli, Maria Serena Chiriacò, Marco Cereda, Giuseppe Gigli, Francesco Ferrara


  • Miniaturized Real-Time PCR systems for SARS-CoV-2 detection at the Point-of-Care

    by Valeria Garzarelli, Maria Serena Chiriacò, Marco Cereda, Isidora Autuori, Francesco Ferrara


  • Open Access

    Femtosecond Laser Fabrication of Microporous Membranes for Biological Applications

    by Annalisa Volpe, Filippo Maria Conte Capodacqua, Valeria Garzarelli, Elisabetta Primiceri, Maria Serena Chiriacò, Caterina Gaudiuso, Francesco Ferrara, Antonio Ancona

    The possibility of fabricating micrometric pore size membranes is gaining great interest in many applications, from studying cell signaling, to filtration. Currently, many technologies are reported to fabricate such microsystems, the choice of which depends strictly on the substrate material and on the final application. Here, we demonstrate the capability with a single femtosecond laser source and experimental setup to fabricate micromembranes both on polymeric and multilayer metallic substrate, without the need for moulds, mask, and complex facilities. In particular, the flexibility of laser drilling was exploited to obtain microfilters with pore size of 8 and 18 µm in diameter, on metallic and polymeric substrate, respectively, and controlled distribution. For evaluating the possibility to use such laser-fabricated membranes into biological assay, their biocompatibility has been investigated. To this aim, as a proof of concept, we tested the two materials into viability tests. The culture of mammalian cells on these microfabricated membranes were studied showing their compatibility with cells.


  • Open Access

    Biofluids manipulation methods for liquid biopsy in minimally-invasive assays

    by Valeria Garzarelli, Francesco Ferrara, Elisabetta Primiceri, Maria Serena Chiriacò