Valeria Garzarelli
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Valeria Garzarelli has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
- Maria Serena Chiriacò
CNR NANOTEC Institute of Nanotechnology, via Monteroni, 73100 Lecce, Italy
9 shared publications - Francesco Ferrara
CNR NANOTEC Institute of Nanotechnology, via Monteroni, 73100 Lecce, Italy
8 shared publications - Alessia Foscarini
CNR NANOTEC Institute of Nanotechnology, via Monteroni, 73100 Lecce, Italy
4 shared publications - Antonio Turco
CNR NANOTEC Institute of Nanotechnology, via Monteroni, 73100 Lecce, Italy
4 shared publications Elisabetta Primiceri
CNR Nanotec Institute of Nanotechnology, via per Monteroni, Lecce 73100, Italy; Tecnomed Puglia - Tecnopolo per la medicina di precisione (Biotech Lecce Hub) c/o Campus Ecotekne, via Monteroni, Lecce 73100, Italy
3 shared publications- Elisabetta Primiceri
CNR Nanotec – Institute of Nanotechnology Lecce Italy
3 shared publications
Latest Publications
- Open Access
- 15 April 2026
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 510, 142088
Mechanochemical upcycling of pyrolyzed cork waste into biocompatible superhydrophobic PDMS sponges for passive oil–water separation
- 15 April 2026
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 510, 142088
Open AccessMechanochemical upcycling of pyrolyzed cork waste into biocompatible superhydrophobic PDMS sponges for passive oil–water separation
- 21 February 2026
- Published by Springer Nature
- p. 37-50
Development of an Automated Edge-Detection Tool for Robust Cell Biology Assays
- 21 February 2026
- Published by Springer Nature
- p. 37-50
Development of an Automated Edge-Detection Tool for Robust Cell Biology Assays
- Open Access
- 9 February 2026
- Published by Elsevier in SSRN Electronic Journal
Mechanochemical upcycling of pyrolyzed cork waste into biocompatible superhydrophobic PDMS sponges for passive oil–water separation
Oil spill pollution and oily wastewater remain persistent threats to aquatic ecosystems, driving the need for environmentally safe and high-performance separation materials. Here, we report a sustainable PDMS-based composite incorporating graphitic carbon derived from cork industrial waste via pyrolysis and solvent-free mechanochemical processing.pCork–PDMS sponges fabricated through solvent-free mechanochemical activation, hard templating, and microwave-assisted curing form robust and recyclable three-dimensional porous networks. The optimal formulation (2 wt% pCork) exhibits superhydrophobic and superoleophilic behavior (water contact angle >150°, oil contact angle ≈0°), rapid and near-quantitative oil uptake, outstanding selectivity for both floating and submerged oils, and high reusability over repeated regeneration cycles, including in complex real seawater matrices.Benchmarking against representative state-of-the-art materials reveals superior volume absorption capacities compared to commonly studied carbon aerogels and graphene-based composites. Critically, rigorous biocompatibility assays under both direct and indirect exposure demonstrate high cell viability and the absence of cytotoxic effects, underscoring the environmental safety of the sorbent itself.Collectively, these findings establish a new materials strategy for hazardous oil–water remediation based on mechanochemically treated, biomass-derived graphitic carbon, demonstrating a rare and benchmarked combination of oil–water interfacial selectivity, rapid uptake kinetics, high absorption capacity, mechanical durability, and biological safety, while shifting PDMS sponge design away from conventional synthetic nanocarbons toward environmentally safe, circular-economy feedstocks.
- 9 February 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMechanochemical upcycling of pyrolyzed cork waste into biocompatible superhydrophobic PDMS sponges for passive oil–water separation
Oil spill pollution and oily wastewater remain persistent threats to aquatic ecosystems, driving the need for environmentally safe and high-performance separation materials. Here, we report a sustainable PDMS-based composite incorporating graphitic carbon derived from cork industrial waste via pyrolysis and solvent-free mechanochemical processing.pCork–PDMS sponges fabricated through solvent-free mechanochemical activation, hard templating, and microwave-assisted curing form robust and recyclable three-dimensional porous networks. The optimal formulation (2 wt% pCork) exhibits superhydrophobic and superoleophilic behavior (water contact angle >150°, oil contact angle ≈0°), rapid and near-quantitative oil uptake, outstanding selectivity for both floating and submerged oils, and high reusability over repeated regeneration cycles, including in complex real seawater matrices.Benchmarking against representative state-of-the-art materials reveals superior volume absorption capacities compared to commonly studied carbon aerogels and graphene-based composites. Critically, rigorous biocompatibility assays under both direct and indirect exposure demonstrate high cell viability and the absence of cytotoxic effects, underscoring the environmental safety of the sorbent itself.Collectively, these findings establish a new materials strategy for hazardous oil–water remediation based on mechanochemically treated, biomass-derived graphitic carbon, demonstrating a rare and benchmarked combination of oil–water interfacial selectivity, rapid uptake kinetics, high absorption capacity, mechanical durability, and biological safety, while shifting PDMS sponge design away from conventional synthetic nanocarbons toward environmentally safe, circular-economy feedstocks.
- Open Access
- 14 September 2025
- Published by Elsevier in Materials & Design
- Vol. 259
3D-printed barriers with machine learning powered image analysis for enhanced wound healing assays
- 14 September 2025
- Published by Elsevier in Materials & Design
- Vol. 259
Open Access3D-printed barriers with machine learning powered image analysis for enhanced wound healing assays
- Open Access
A Microfluidic-Based Sensing Platform for Rapid Quality Control on Target Cells from Bioreactors
We investigated the design and characterization of a Lab-On-a-Chip (LoC) cell detection system primarily designed to support immunotherapy in cancer treatment. Immunotherapy uses Chimeric Antigen Receptors (CARs) and T Cell Receptors (TCRs) to fight cancer, engineering the response of the immune system. In recent years, it has emerged as a promising strategy for personalized cancer treatment. However, it requires bioreactor-based cell culture expansion and manual quality control (QC) of the modified cells, which is time-consuming, labour-intensive, and prone to errors. The miniaturized LoC device for automated QC demonstrated here is simple, has a low cost, and is reliable. Its final target is to become one of the building blocks of an LoC for immunotherapy, which would take the place of present labs and manual procedures to the benefit of throughput and affordability. The core of the system is a commercial, on-chip-integrated capacitive sensor managed by a microcontroller capable of sensing cells as accurately measured charge variations. The hardware is based on standardized components, which makes it suitable for mass manufacturing. Moreover, unlike in other cell detection solutions, no external AC source is required. The device has been characterized with a cell line model selectively labelled with gold nanoparticles to simulate its future use in bioreactors in which labelling can apply to successfully engineered CAR-T-cells. Experiments were run both in the air—free drop with no microfluidics—and in the channel, where the fluid volume was considerably lower than in the drop. The device showed good sensitivity even with a low number of cells—around 120, compared with the 107 to 108 needed per kilogram of body weight—which is desirable for a good outcome of the expansion process. Since cell detection is needed in several contexts other than immunotherapy, the usefulness of this LoC goes potentially beyond the scope considered here.
Open AccessA Microfluidic-Based Sensing Platform for Rapid Quality Control on Target Cells from Bioreactors
We investigated the design and characterization of a Lab-On-a-Chip (LoC) cell detection system primarily designed to support immunotherapy in cancer treatment. Immunotherapy uses Chimeric Antigen Receptors (CARs) and T Cell Receptors (TCRs) to fight cancer, engineering the response of the immune system. In recent years, it has emerged as a promising strategy for personalized cancer treatment. However, it requires bioreactor-based cell culture expansion and manual quality control (QC) of the modified cells, which is time-consuming, labour-intensive, and prone to errors. The miniaturized LoC device for automated QC demonstrated here is simple, has a low cost, and is reliable. Its final target is to become one of the building blocks of an LoC for immunotherapy, which would take the place of present labs and manual procedures to the benefit of throughput and affordability. The core of the system is a commercial, on-chip-integrated capacitive sensor managed by a microcontroller capable of sensing cells as accurately measured charge variations. The hardware is based on standardized components, which makes it suitable for mass manufacturing. Moreover, unlike in other cell detection solutions, no external AC source is required. The device has been characterized with a cell line model selectively labelled with gold nanoparticles to simulate its future use in bioreactors in which labelling can apply to successfully engineered CAR-T-cells. Experiments were run both in the air—free drop with no microfluidics—and in the channel, where the fluid volume was considerably lower than in the drop. The device showed good sensitivity even with a low number of cells—around 120, compared with the 107 to 108 needed per kilogram of body weight—which is desirable for a good outcome of the expansion process. Since cell detection is needed in several contexts other than immunotherapy, the usefulness of this LoC goes potentially beyond the scope considered here.
- Open Access
- 10 May 2024
- Published by MDPI AG in Proceedings
- Vol. 97 (1) , 214
TITAN Project: Microfluidic and Sensing Tools for Immunotherapy
The TITAN project aims to improve immunotherapy, targeting the efficiency of methods to obtain genetically engineered T cells. Immunotherapy has achieved great success in clinical trials, but it is currently very expensive in terms of time required for analysis, reagents, and samples. TITAN aims to the continuous sampling of critical quality attributes, in order to quickly recognize deviations from the desired range and take appropriate corrective actions on process parameters for an optimal outcome. To achieve its aims, TITAN is currently developing microfluidic and sensing tools for the accurate and efficient real-time monitoring of the T cells amplification process.
- 10 May 2024
- Published by MDPI AG in Proceedings
- Vol. 97 (1) , 214
Open AccessTITAN Project: Microfluidic and Sensing Tools for Immunotherapy
The TITAN project aims to improve immunotherapy, targeting the efficiency of methods to obtain genetically engineered T cells. Immunotherapy has achieved great success in clinical trials, but it is currently very expensive in terms of time required for analysis, reagents, and samples. TITAN aims to the continuous sampling of critical quality attributes, in order to quickly recognize deviations from the desired range and take appropriate corrective actions on process parameters for an optimal outcome. To achieve its aims, TITAN is currently developing microfluidic and sensing tools for the accurate and efficient real-time monitoring of the T cells amplification process.
- 17 September 2022
- Published by Elsevier in Clinica Chimica Acta
- Vol. 536, 104-111
Miniaturized Real-Time PCR systems for SARS-CoV-2 detection at the Point-of-Care
- 17 September 2022
- Published by Elsevier in Clinica Chimica Acta
- Vol. 536, 104-111
Miniaturized Real-Time PCR systems for SARS-CoV-2 detection at the Point-of-Care
- Open Access
- 23 August 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (9) , 1371
Femtosecond Laser Fabrication of Microporous Membranes for Biological Applications
The possibility of fabricating micrometric pore size membranes is gaining great interest in many applications, from studying cell signaling, to filtration. Currently, many technologies are reported to fabricate such microsystems, the choice of which depends strictly on the substrate material and on the final application. Here, we demonstrate the capability with a single femtosecond laser source and experimental setup to fabricate micromembranes both on polymeric and multilayer metallic substrate, without the need for moulds, mask, and complex facilities. In particular, the flexibility of laser drilling was exploited to obtain microfilters with pore size of 8 and 18 µm in diameter, on metallic and polymeric substrate, respectively, and controlled distribution. For evaluating the possibility to use such laser-fabricated membranes into biological assay, their biocompatibility has been investigated. To this aim, as a proof of concept, we tested the two materials into viability tests. The culture of mammalian cells on these microfabricated membranes were studied showing their compatibility with cells.
- 23 August 2022
- Published by MDPI AG in Micromachines
- Vol. 13 (9) , 1371
Open AccessFemtosecond Laser Fabrication of Microporous Membranes for Biological Applications
The possibility of fabricating micrometric pore size membranes is gaining great interest in many applications, from studying cell signaling, to filtration. Currently, many technologies are reported to fabricate such microsystems, the choice of which depends strictly on the substrate material and on the final application. Here, we demonstrate the capability with a single femtosecond laser source and experimental setup to fabricate micromembranes both on polymeric and multilayer metallic substrate, without the need for moulds, mask, and complex facilities. In particular, the flexibility of laser drilling was exploited to obtain microfilters with pore size of 8 and 18 µm in diameter, on metallic and polymeric substrate, respectively, and controlled distribution. For evaluating the possibility to use such laser-fabricated membranes into biological assay, their biocompatibility has been investigated. To this aim, as a proof of concept, we tested the two materials into viability tests. The culture of mammalian cells on these microfabricated membranes were studied showing their compatibility with cells.