Guilherme dos Santos Trento
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Guilherme dos Santos Trento has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
Leandro Eduardo Klüppel
Univ Fed Parana, Dept Oral & Maxillofacial Surg, Curitiba, PR, Brazil
7 shared publications- Rafaela Scariot
Federal University of Parana
5 shared publications - Nelson Luis Barbosa Rebellato
Department of Stomatology, Federal University of Paraná, Curitiba, Brazil
4 shared publications - Valfrido Antonio Pereira-Filho
Department of Diagnosis and Surgery, School of Dentistry Araraquara, São Paulo State University (UNESP), Araraquara 14801-903, SP, Brazil
4 shared publications - Pedro Henrique de Azambuja Carvalho
São Paulo State University, Brazil
3 shared publications Aline Monise Sebastiani
Univ Fed Parana, Dept Oral & Maxillofacial Surg, Curitiba, PR, Brazil
2 shared publications
Latest Publications
- Open Access
- 25 April 2025
- Published by Elsevier in Journal of Stomatology Oral and Maxillofacial Surgery
- Vol. 126 (5) , 102381
Cystic teratoma of the head and neck region in the neonate – description of three cases
- 25 April 2025
- Published by Elsevier in Journal of Stomatology Oral and Maxillofacial Surgery
- Vol. 126 (5) , 102381
Open AccessCystic teratoma of the head and neck region in the neonate – description of three cases
- 1 March 2023
- Published by AME Publishing Company in Frontiers of Oral and Maxillofacial Medicine
- Vol. 5, 6
Use of xenogenous bone substitutes simultaneously to implant placement: literature review
Use of xenogenous bone substitutes simultaneously to implant placement: literature review Bernardo Olsson, Katheleen Miranda Dos Santos, Paola Fernanda de Lucas Cotait Corso, Aline Monise Sebastiani, Leandro Eduardo Klüppel, Rafaela Scariot, Guilherme Trento
- 1 March 2023
- Published by AME Publishing Company in Frontiers of Oral and Maxillofacial Medicine
- Vol. 5, 6
Use of xenogenous bone substitutes simultaneously to implant placement: literature review
Use of xenogenous bone substitutes simultaneously to implant placement: literature review Bernardo Olsson, Katheleen Miranda Dos Santos, Paola Fernanda de Lucas Cotait Corso, Aline Monise Sebastiani, Leandro Eduardo Klüppel, Rafaela Scariot, Guilherme Trento
- 2 August 2022
- Published by Springer Nature in Oral and Maxillofacial Surgery
- Vol. 27 (4) , 631-638
Tissue response to different incision tools in animal model
Purpose The aim of this study is to compare the repair of incisions performed with microdissection electrocautery tip, conventional electrocautery tip, high potency diode laser, and conventional scalpel blade in a in vivo model. Methods Different incisions were performed in adults Holtzman rats using the four types of instruments: microdissection electrocautery tip, conventional electrocautery tip, high potency diode laser, and conventional scalpel blade, in different periods of healing process. Thirty rats were divided into 5 groups, according to the period of euthanasia—24 h, 48 h, 72 h, 7 days, and 14 days. All animals received four incisions, each by a different method. Quantitative histological and histomorphometric analyses were performed using hematoxylin and eosin (HE) and Picrosirius Red staining. Results Inflammatory profile and tissue repair presented small statistically significance differences comparing conventional scalpel blade and microdissection tip; moreover, both presented quantitatively superior to the others. Conclusion It is believed that the microdissection tip can perform a dynamic incision just as a common scalpel blade, but more effective. Furthermore, it can promote a better hemostatic control of the surgical field that is comparable to conventional electrocautery tip without affecting tissue repair.
- 2 August 2022
- Published by Springer Nature in Oral and Maxillofacial Surgery
- Vol. 27 (4) , 631-638
Tissue response to different incision tools in animal model
Purpose The aim of this study is to compare the repair of incisions performed with microdissection electrocautery tip, conventional electrocautery tip, high potency diode laser, and conventional scalpel blade in a in vivo model. Methods Different incisions were performed in adults Holtzman rats using the four types of instruments: microdissection electrocautery tip, conventional electrocautery tip, high potency diode laser, and conventional scalpel blade, in different periods of healing process. Thirty rats were divided into 5 groups, according to the period of euthanasia—24 h, 48 h, 72 h, 7 days, and 14 days. All animals received four incisions, each by a different method. Quantitative histological and histomorphometric analyses were performed using hematoxylin and eosin (HE) and Picrosirius Red staining. Results Inflammatory profile and tissue repair presented small statistically significance differences comparing conventional scalpel blade and microdissection tip; moreover, both presented quantitatively superior to the others. Conclusion It is believed that the microdissection tip can perform a dynamic incision just as a common scalpel blade, but more effective. Furthermore, it can promote a better hemostatic control of the surgical field that is comparable to conventional electrocautery tip without affecting tissue repair.
- Open Access
- 1 December 2020
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 6 (1) , 1-14
Gene expression, immunohistochemical and microarchitectural evaluation of bone formation around two implant surfaces placed in bone defects filled or not with bone substitute material
Objective: The aim of this study is to evaluate through gene expression, immunohistochemical and microtomographic (micro-CT) analysis the response of peri-implant bone tissue around titanium implants with different surface treatments, placed in bone defects filled or not with bone substitute materials. In addition, to investigate the hypothesis that porous-hydrophilic surface induces a faster bone formation. Materials and methods: Twenty-six animals were divided into two groups according to implant surface treatment. In each tibia, a bone defect was created followed by the placement of one implant. On the left tibia, the defect was filled with blood clot (BC), and on the right tibia, the defect was filled with biphasic hydroxyapatite/β-tricalcium-phosphate (HA/TCP) generating four subgroups: BC-N: bone defect filled with blood clot and porous surface titanium implant installed; BC-A: bone defect filled with blood clot and porous-hydrophilic surface titanium implant installed; HA/TCP-N: bone defect filled with bone substitute material and porous surface titanium implant installed; and HA/TCP-A: bone defect filled with bone substitute material and porous-hydrophilic surface titanium implant installed. The animals were submitted to euthanasia at 15, 30, and 60 days after implant installation. The expression of two genes was evaluated: RUNX2 and BSP. Immunohistochemical analyses were performed for detection of RUNX2, OPN, OCN, OPG, and RANKL antibodies and bone matrix proteins. Finally, four parameters were chosen for micro-CT analysis: trabecular number, separation and thickness, and connectivity density. Results: Descriptive analysis showed similar findings among the experimental groups. Moreover, porous-hydrophilic surfaces presented a higher expression of RUNX2, which is probably an indicative of better osteogenesis; although the data from this study may be considered an insufficient support for a concrete statement. Conclusion: Porous hydrophilic surface can improve and accelerate protein expression and bone formation.
- 1 December 2020
- Published by Springer Nature in International Journal of Implant Dentistry
- Vol. 6 (1) , 1-14
Open AccessGene expression, immunohistochemical and microarchitectural evaluation of bone formation around two implant surfaces placed in bone defects filled or not with bone substitute material
Objective: The aim of this study is to evaluate through gene expression, immunohistochemical and microtomographic (micro-CT) analysis the response of peri-implant bone tissue around titanium implants with different surface treatments, placed in bone defects filled or not with bone substitute materials. In addition, to investigate the hypothesis that porous-hydrophilic surface induces a faster bone formation. Materials and methods: Twenty-six animals were divided into two groups according to implant surface treatment. In each tibia, a bone defect was created followed by the placement of one implant. On the left tibia, the defect was filled with blood clot (BC), and on the right tibia, the defect was filled with biphasic hydroxyapatite/β-tricalcium-phosphate (HA/TCP) generating four subgroups: BC-N: bone defect filled with blood clot and porous surface titanium implant installed; BC-A: bone defect filled with blood clot and porous-hydrophilic surface titanium implant installed; HA/TCP-N: bone defect filled with bone substitute material and porous surface titanium implant installed; and HA/TCP-A: bone defect filled with bone substitute material and porous-hydrophilic surface titanium implant installed. The animals were submitted to euthanasia at 15, 30, and 60 days after implant installation. The expression of two genes was evaluated: RUNX2 and BSP. Immunohistochemical analyses were performed for detection of RUNX2, OPN, OCN, OPG, and RANKL antibodies and bone matrix proteins. Finally, four parameters were chosen for micro-CT analysis: trabecular number, separation and thickness, and connectivity density. Results: Descriptive analysis showed similar findings among the experimental groups. Moreover, porous-hydrophilic surfaces presented a higher expression of RUNX2, which is probably an indicative of better osteogenesis; although the data from this study may be considered an insufficient support for a concrete statement. Conclusion: Porous hydrophilic surface can improve and accelerate protein expression and bone formation.
- 1 April 2020
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 22 (2) , 177-185
Bone formation around two titanium implant surfaces placed in bone defects with and without a bone substitute material: A histological, histomorphometric, and micro-computed tomography evaluation
Objective To evaluate the histological and microtomographic response of peri-implant bone tissue around titanium implants with different surface treatments, placed in bone defects filled or not filled with bone substitute materials. Materials and Methods Thirty rabbits were divided into two groups according to the implant surface treatment. A bone defect was created in both tibias of all the rabbits, followed by the placement of one implant in each of these defects. On the left tibia, the defect was filled with a blood clot (BC), and on the right tibia, the defect was filled with biphasic hydroxyapatite/beta-tricalcium-phosphate (HA/TCP); thus, there were four groups in total: BC-N: bone defect filled with a BC and porous surface titanium implant (control group); BC-A: bone defect filled with a BC and porous-hydrophilic surface titanium implant; HA/TCP-N: bone defect filled with a bone substitute material and porous surface titanium implant; HA/TCP-A: bone defect filled with a bone substitute material and porous-hydrophilic surface titanium implant. The animals were submitted for euthanasia at three distinct periods: 15, 30, and 60 days after implant installation. The samples were evaluated histologically and histometrically, to assess the quantity and quality of cells and the remaining bone substitute material in the grafted areas. The bone quantity was assessed by micro-computed tomography (CT). Results For both surface types, the presence of a bone substitute material led to higher values in all evaluated micro-CT parameters, except in the bone surface/volume ratio parameter. No significant statistical difference was found for new bone formation between the four groups (P < .05; CI 95%). At all periods, the HA/TCP-A group had a higher percentage of new bone formation. Conclusion These results suggest that a porous hydrophilic surface in the presence of bone substitute material can accelerate peri-implant bone tissue formation.
- 1 April 2020
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 22 (2) , 177-185
Bone formation around two titanium implant surfaces placed in bone defects with and without a bone substitute material: A histological, histomorphometric, and micro-computed tomography evaluation
Objective To evaluate the histological and microtomographic response of peri-implant bone tissue around titanium implants with different surface treatments, placed in bone defects filled or not filled with bone substitute materials. Materials and Methods Thirty rabbits were divided into two groups according to the implant surface treatment. A bone defect was created in both tibias of all the rabbits, followed by the placement of one implant in each of these defects. On the left tibia, the defect was filled with a blood clot (BC), and on the right tibia, the defect was filled with biphasic hydroxyapatite/beta-tricalcium-phosphate (HA/TCP); thus, there were four groups in total: BC-N: bone defect filled with a BC and porous surface titanium implant (control group); BC-A: bone defect filled with a BC and porous-hydrophilic surface titanium implant; HA/TCP-N: bone defect filled with a bone substitute material and porous surface titanium implant; HA/TCP-A: bone defect filled with a bone substitute material and porous-hydrophilic surface titanium implant. The animals were submitted for euthanasia at three distinct periods: 15, 30, and 60 days after implant installation. The samples were evaluated histologically and histometrically, to assess the quantity and quality of cells and the remaining bone substitute material in the grafted areas. The bone quantity was assessed by micro-computed tomography (CT). Results For both surface types, the presence of a bone substitute material led to higher values in all evaluated micro-CT parameters, except in the bone surface/volume ratio parameter. No significant statistical difference was found for new bone formation between the four groups (P < .05; CI 95%). At all periods, the HA/TCP-A group had a higher percentage of new bone formation. Conclusion These results suggest that a porous hydrophilic surface in the presence of bone substitute material can accelerate peri-implant bone tissue formation.
- 6 November 2019
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 21 (6) , 1175-1180
Bone tissue formation around two titanium implant surfaces placed in bone defects filled with bone substitute material or blood clot: A pilot study
Objectives: The objective of this study was to evaluate the peri‐implant bone tissue formation around titanium implants with different surface treatments, placed in bone defects filled or not with bone substitute material (BSM).Materials and Methods: Ten animals were divided into two groups according to implant surface treatment. In each tibia, a bone defect was created followed by the placement of one implant. On the left tibia, the defect was filled with blood clot (BC), and on the right tibia, the defect was filled with biphasic hydroxyapatite/β‐tricalcium‐phosphate (HA/TCP) generating four subgroups: BC‐N: blood clot and porous surface; BC‐A: blood clot and porous‐hydrophilic surface; HA/TCP‐N: BSM and porous surface; HA/TCP‐A: BSM and porous‐hydrophilic surface. The animals were submitted to euthanasia 60 days after implant installation. After light‐curing resin inclusion, the blocks containing the implant and the bone tissue were stained and evaluated by means of histomorphometry to assess the percentages of bone implant contact (% BIC). Data was normally distributed and the group differences were examined using the parametric tests of Two‐Way ANOVA.Results: The BC‐A group presented the higher mean value of BIC (46.43%). The HA/TCP‐A group presented the higher mean value of BIC. The porous‐hydrophilic surfaces presented better results of BIC when compared to the porous surface in both conditions of defect filling. No statistically significant differences were found among all groups (95% confidence interval and P < .05).Conclusion: According to histomorphometric analysis, after 60‐days in a rabbit model, hydrophilic and hydrophobic surfaces have the same behavior in the presence or absence of HA/TCP.
- 6 November 2019
- Published by Wiley in Clinical Implant Dentistry and Related Research
- Vol. 21 (6) , 1175-1180
Bone tissue formation around two titanium implant surfaces placed in bone defects filled with bone substitute material or blood clot: A pilot study
Objectives: The objective of this study was to evaluate the peri‐implant bone tissue formation around titanium implants with different surface treatments, placed in bone defects filled or not with bone substitute material (BSM).Materials and Methods: Ten animals were divided into two groups according to implant surface treatment. In each tibia, a bone defect was created followed by the placement of one implant. On the left tibia, the defect was filled with blood clot (BC), and on the right tibia, the defect was filled with biphasic hydroxyapatite/β‐tricalcium‐phosphate (HA/TCP) generating four subgroups: BC‐N: blood clot and porous surface; BC‐A: blood clot and porous‐hydrophilic surface; HA/TCP‐N: BSM and porous surface; HA/TCP‐A: BSM and porous‐hydrophilic surface. The animals were submitted to euthanasia 60 days after implant installation. After light‐curing resin inclusion, the blocks containing the implant and the bone tissue were stained and evaluated by means of histomorphometry to assess the percentages of bone implant contact (% BIC). Data was normally distributed and the group differences were examined using the parametric tests of Two‐Way ANOVA.Results: The BC‐A group presented the higher mean value of BIC (46.43%). The HA/TCP‐A group presented the higher mean value of BIC. The porous‐hydrophilic surfaces presented better results of BIC when compared to the porous surface in both conditions of defect filling. No statistically significant differences were found among all groups (95% confidence interval and P < .05).Conclusion: According to histomorphometric analysis, after 60‐days in a rabbit model, hydrophilic and hydrophobic surfaces have the same behavior in the presence or absence of HA/TCP.
- 1 April 2019
- Published by Elsevier in International Journal of Oral and Maxillofacial Surgery
- Vol. 48 (4) , 546-553
Titanium mesh associated with rhBMP-2 in alveolar ridge reconstruction
- 1 April 2019
- Published by Elsevier in International Journal of Oral and Maxillofacial Surgery
- Vol. 48 (4) , 546-553
Titanium mesh associated with rhBMP-2 in alveolar ridge reconstruction
- Open Access
- 1 January 2019
- Published by Wiley in Case Reports in Surgery
- Vol. 2019 (1) , 8351825
Intranasal Ectopic Tooth in Adult and Pediatric Patients: A Report of Two Cases
The aim of this study was to report two rare cases of ectopic tooth into the nasal cavity. The first case reports a 32‐year‐old female patient with the main complaint of having a tooth inside her nose. According to her, this condition causes pain and sporadic nosebleed. The patient had a facial trauma when she was 6 years old. The second case refers to an 8‐year‐old girl with left incomplete unilateral cleft lip and palate. The main complaint was left‐sided nasal obstruction by a white hard mass. The treatment for both cases was surgical removal of the ectopic erupted tooth under general anesthesia. In conclusion, we can state that the surgical removal of intranasal tooth is a safe procedure and improves patient’s quality of life.
- 1 January 2019
- Published by Wiley in Case Reports in Surgery
- Vol. 2019 (1) , 8351825
Open AccessIntranasal Ectopic Tooth in Adult and Pediatric Patients: A Report of Two Cases
The aim of this study was to report two rare cases of ectopic tooth into the nasal cavity. The first case reports a 32‐year‐old female patient with the main complaint of having a tooth inside her nose. According to her, this condition causes pain and sporadic nosebleed. The patient had a facial trauma when she was 6 years old. The second case refers to an 8‐year‐old girl with left incomplete unilateral cleft lip and palate. The main complaint was left‐sided nasal obstruction by a white hard mass. The treatment for both cases was surgical removal of the ectopic erupted tooth under general anesthesia. In conclusion, we can state that the surgical removal of intranasal tooth is a safe procedure and improves patient’s quality of life.
- Open Access
- 26 October 2018
- Published by Universidad Autonoma de Chile in International Journal of Medical and Surgical Sciences
- Vol. 2 (1) , 420-425
Treatment of Zygomatic-Orbital Complex Fracture Through Transconjunctival Approach
Fractures of the zygomatic-orbital complex have been described as common in the midface traumas. The surgical approach election is an important decision when there is a risk of interference to function, aesthetics or an association of both. The pursuit of techniques that offer adequate visualization of the interested area associated with low morbidity has been responsible for the development of new techniques and materials. The better approach still remains with a lot of controversy among different authors. However, the transconjunctival incision can be considered in access fractures of the zygomatic-orbital complex. The purpose of this study is report a case of performing transconjunctival approach associated with lateral canthotomy to treatment of zygomatic-orbital complex fractures caused by sports trauma of a 34 years-old male patient.
- 26 October 2018
- Published by Universidad Autonoma de Chile in International Journal of Medical and Surgical Sciences
- Vol. 2 (1) , 420-425
Open AccessTreatment of Zygomatic-Orbital Complex Fracture Through Transconjunctival Approach
Fractures of the zygomatic-orbital complex have been described as common in the midface traumas. The surgical approach election is an important decision when there is a risk of interference to function, aesthetics or an association of both. The pursuit of techniques that offer adequate visualization of the interested area associated with low morbidity has been responsible for the development of new techniques and materials. The better approach still remains with a lot of controversy among different authors. However, the transconjunctival incision can be considered in access fractures of the zygomatic-orbital complex. The purpose of this study is report a case of performing transconjunctival approach associated with lateral canthotomy to treatment of zygomatic-orbital complex fractures caused by sports trauma of a 34 years-old male patient.
- Open Access
- 1 September 2018
- Published by Elsevier in Oral and Maxillofacial Surgery Cases
- Vol. 4 (3) , 108-114
Segmental orthognathic surgery for Bolton discrepancy correction
- 1 September 2018
- Published by Elsevier in Oral and Maxillofacial Surgery Cases
- Vol. 4 (3) , 108-114
Open AccessSegmental orthognathic surgery for Bolton discrepancy correction