Jinghua Tang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Jinghua Tang has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Liudi Jiang
School of Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, UK
5 shared publications David Moser
School of Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, UK
4 shared publications- Kirstie Devin
School of Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton SO17 1BJ, UK
3 shared publications - Dan L. Bader
University of Southampton
2 shared publications Liudi Jiang
School of Engineering, Faculty of Engineering and Physical Sciences, University of Southampton, Southampton, UK
2 shared publications- Michael McGrath
Blatchford Group, Unit D Antura, Bond Close, Basingstoke, RG24 8PZ, UK
2 shared publications
Latest Publications
- Open Access
Evaluation of Hand Action Classification Performance Using Machine Learning Based on Signals from Two sEMG Electrodes
Classification-based myoelectric control has attracted significant interest in recent years, leading to prosthetic hands with advanced functionality, such as multi-grip hands. Thus far, high classification accuracies have been achieved by increasing the number of surface electromyography (sEMG) electrodes or adding other sensing mechanisms. While many prescribed myoelectric hands still adopt two-electrode sEMG systems, detailed studies on signal processing and classification performance are still lacking. In this study, nine able-bodied participants were recruited to perform six typical hand actions, from which sEMG signals from two electrodes were acquired using a Delsys Trigno Research+ acquisition system. Signal processing and machine learning algorithms, specifically, linear discriminant analysis (LDA), k-nearest neighbors (KNN), and support vector machines (SVM), were used to study classification accuracies. Overall classification accuracy of 93 ± 2%, action-specific accuracy of 97 ± 2%, and F1-score of 87 ± 7% were achieved, which are comparable with those reported from multi-electrode systems. The highest accuracies were achieved using SVM algorithm compared to LDA and KNN algorithms. A logarithmic relationship between classification accuracy and number of features was revealed, which plateaued at five features. These comprehensive findings may potentially contribute to signal processing and machine learning strategies for commonly prescribed myoelectric hand systems with two sEMG electrodes to further improve functionality.
Open AccessEvaluation of Hand Action Classification Performance Using Machine Learning Based on Signals from Two sEMG Electrodes
Classification-based myoelectric control has attracted significant interest in recent years, leading to prosthetic hands with advanced functionality, such as multi-grip hands. Thus far, high classification accuracies have been achieved by increasing the number of surface electromyography (sEMG) electrodes or adding other sensing mechanisms. While many prescribed myoelectric hands still adopt two-electrode sEMG systems, detailed studies on signal processing and classification performance are still lacking. In this study, nine able-bodied participants were recruited to perform six typical hand actions, from which sEMG signals from two electrodes were acquired using a Delsys Trigno Research+ acquisition system. Signal processing and machine learning algorithms, specifically, linear discriminant analysis (LDA), k-nearest neighbors (KNN), and support vector machines (SVM), were used to study classification accuracies. Overall classification accuracy of 93 ± 2%, action-specific accuracy of 97 ± 2%, and F1-score of 87 ± 7% were achieved, which are comparable with those reported from multi-electrode systems. The highest accuracies were achieved using SVM algorithm compared to LDA and KNN algorithms. A logarithmic relationship between classification accuracy and number of features was revealed, which plateaued at five features. These comprehensive findings may potentially contribute to signal processing and machine learning strategies for commonly prescribed myoelectric hand systems with two sEMG electrodes to further improve functionality.
- Open Access
- 27 January 2024
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 238 (3) , 348-357
Assessment of 3D printed mechanical metamaterials for prosthetic liners
This study focuses on novel design and evaluation of Elastic 50A (EL50) mechanical metamaterials with open-cell patterns for its potential application to lower limb residuum/socket interfaces, specifically that of a transtibial (TT) amputee. Mechanical characteristics, that is, effective Young’s modulus ( E), was tuned by altering metamaterial porosity, which was experimentally verified. Specifically, pore radius of the unit cell was varied to achieve a range of E-values (0.05–1.71 MPa) for these 3D printed metamaterials. Finite Element Analysis (FEA) was conducted to evaluate pressure distribution across key load-bearing anatomical sites of a TT residuum. Using designed metamaterials for homogeneous liners, pressure profiles were studied and compared with a silicone liner case. Additionally, a custom metamaterial liner was designed by assigning appropriate metamaterials to four load-sensitive and tolerant anatomical sites of the TT residuum. The results suggest that lowest pressure variation (PV), as a measure of pressure distribution levels and potential comfort for amputees, was achieved by the custom metamaterial liner compared to any of the homogeneous liners included in this study. It is envisaged that this work may aid future design and development of custom liners using now commonly available 3D printing technologies and available elastomer materials to maximise comfort, tissue safety and overall rehabilitation outcomes for lower limb amputees.
- 27 January 2024
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 238 (3) , 348-357
Open AccessAssessment of 3D printed mechanical metamaterials for prosthetic liners
This study focuses on novel design and evaluation of Elastic 50A (EL50) mechanical metamaterials with open-cell patterns for its potential application to lower limb residuum/socket interfaces, specifically that of a transtibial (TT) amputee. Mechanical characteristics, that is, effective Young’s modulus ( E), was tuned by altering metamaterial porosity, which was experimentally verified. Specifically, pore radius of the unit cell was varied to achieve a range of E-values (0.05–1.71 MPa) for these 3D printed metamaterials. Finite Element Analysis (FEA) was conducted to evaluate pressure distribution across key load-bearing anatomical sites of a TT residuum. Using designed metamaterials for homogeneous liners, pressure profiles were studied and compared with a silicone liner case. Additionally, a custom metamaterial liner was designed by assigning appropriate metamaterials to four load-sensitive and tolerant anatomical sites of the TT residuum. The results suggest that lowest pressure variation (PV), as a measure of pressure distribution levels and potential comfort for amputees, was achieved by the custom metamaterial liner compared to any of the homogeneous liners included in this study. It is envisaged that this work may aid future design and development of custom liners using now commonly available 3D printing technologies and available elastomer materials to maximise comfort, tissue safety and overall rehabilitation outcomes for lower limb amputees.
- 2 September 2023
- Published by Mark Allen Group in Journal of Wound Care
- Vol. 32 (9) , 587-596
Evaluation of in-shoe plantar pressure and shear during walking for diabetic foot ulcer prevention
Objective: To investigate reliability and changes of in-shoe plantar pressure and shear during walking at three cadences with two insole designs. This was a precursor to the investigation of plantar loading in people with diabetes for potential foot ulcer prevention. Method: A sensorised insole system, capable of measuring plantar pressure and shear at the heel, fifth metatarsal head (5MH), first metatarsal head (1MH) and hallux, was tested with ten healthy participants during level walking. Reliability was evaluated, using intra-class correlation coefficient (ICC), while varying the cadences and insole types. Percentage changes in pressure and shear relative to values obtained at self-selected cadence with a flat insole design were investigated. Results: Mean +/- standard deviation of maximum pressure, medial-lateral and anterior-posterior shear of up to 380 +/- 24kPa, 46 +/- 2kPa and -71 +/- 4kPa, respectively, were measured. The ICC in ranges of 0.762-0.973, 0.758-0.987 and 0.800-0.980 were obtained for pressure, anterior-posterior and medial-lateral shear, respectively. Opposite anterior-posterior shear directions between 5MH and 1MH (stretching), and between 1MH and hallux (pinching) were observed for some participants. Increasing cadence increased pressure and anterior-posterior shear (by up to +77%) but reduced medial-lateral shear at the heel and hallux (by up to -34%). Slower cadence increased anterior-posterior shear (+114%) but decreased medial-lateral shear (-46%) at the hallux. The use of a flexible contoured insole resulted in pressure reduction at the heel and 5MH but an increase in anterior-posterior shear at the heel (+69%) and hallux (+75%). Conclusion: The insole system demonstrated good reliability and is comparable to reported pressure-only systems. Pressure measurements were sensitive to changes in cadence and insole designs in ways that were consistent with the literature. However, our plantar shear showed localised shear changes with cadences and insoles for the first time, as well as stretching and pinching effects on plantar tissue. This opens new possibilities to investigate plantar tissue viability, loading characteristics and orthotic designs aimed towards foot ulcer prevention.
- 2 September 2023
- Published by Mark Allen Group in Journal of Wound Care
- Vol. 32 (9) , 587-596
Evaluation of in-shoe plantar pressure and shear during walking for diabetic foot ulcer prevention
Objective: To investigate reliability and changes of in-shoe plantar pressure and shear during walking at three cadences with two insole designs. This was a precursor to the investigation of plantar loading in people with diabetes for potential foot ulcer prevention. Method: A sensorised insole system, capable of measuring plantar pressure and shear at the heel, fifth metatarsal head (5MH), first metatarsal head (1MH) and hallux, was tested with ten healthy participants during level walking. Reliability was evaluated, using intra-class correlation coefficient (ICC), while varying the cadences and insole types. Percentage changes in pressure and shear relative to values obtained at self-selected cadence with a flat insole design were investigated. Results: Mean +/- standard deviation of maximum pressure, medial-lateral and anterior-posterior shear of up to 380 +/- 24kPa, 46 +/- 2kPa and -71 +/- 4kPa, respectively, were measured. The ICC in ranges of 0.762-0.973, 0.758-0.987 and 0.800-0.980 were obtained for pressure, anterior-posterior and medial-lateral shear, respectively. Opposite anterior-posterior shear directions between 5MH and 1MH (stretching), and between 1MH and hallux (pinching) were observed for some participants. Increasing cadence increased pressure and anterior-posterior shear (by up to +77%) but reduced medial-lateral shear at the heel and hallux (by up to -34%). Slower cadence increased anterior-posterior shear (+114%) but decreased medial-lateral shear (-46%) at the hallux. The use of a flexible contoured insole resulted in pressure reduction at the heel and 5MH but an increase in anterior-posterior shear at the heel (+69%) and hallux (+75%). Conclusion: The insole system demonstrated good reliability and is comparable to reported pressure-only systems. Pressure measurements were sensitive to changes in cadence and insole designs in ways that were consistent with the literature. However, our plantar shear showed localised shear changes with cadences and insoles for the first time, as well as stretching and pinching effects on plantar tissue. This opens new possibilities to investigate plantar tissue viability, loading characteristics and orthotic designs aimed towards foot ulcer prevention.
- Open Access
- 16 August 2023
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2023, 1-8
Assessing Socket Fit Effects on Pressure and Shear at a Transtibial Residuum/Socket Interface
Fluctuations in residuum volume during daily activities are known to occur in lower-limb amputees. This can cause frequent changes to fit, which cannot be accommodated by commonly-used prosthetic sockets. The real-time effects, if any, of these minor socket fit changes on interface biomechanics have not been studied extensively. Amputees commonly use different layers of socks to accommodate frequent volume fluctuations, enabling adjustment of socket fit. We, thus, altered socket fit levels via addition/removal of sock layers to a transtibial amputee who habitually-donned two-sock layers to mimic relatively looser and tighter socket fits. Interface pressure and shear sensors were placed at known prominent load-bearing sites of the transtibial residuum/socket interface, i.e., patellar tendon (PT), popliteal fossa (PF), and anterior–distal (AD) end, to measure real-time biomechanical interactions during standing and level walking. Although socket fit level was only slightly modified, changes in interface pressure and shear across anatomical sites were still observed. Tighter fit corresponds to notable pressure reduction at AD during early stance and pressure increase at PT during terminal stance due to the residuum being pushed up. Shear-to-pressure ratios were used to assess comfort, while pressure– and shear–time integrals were used to assess tissue health. We observed more notable changes at tissue sites (e.g., AD and PF). Combined evaluation of pressure and shear, including shear-to-pressure ratio and time integrals, may offer insight for residuum care.
- 16 August 2023
- Published by Wiley in Applied Bionics and Biomechanics
- Vol. 2023, 1-8
Open AccessAssessing Socket Fit Effects on Pressure and Shear at a Transtibial Residuum/Socket Interface
Fluctuations in residuum volume during daily activities are known to occur in lower-limb amputees. This can cause frequent changes to fit, which cannot be accommodated by commonly-used prosthetic sockets. The real-time effects, if any, of these minor socket fit changes on interface biomechanics have not been studied extensively. Amputees commonly use different layers of socks to accommodate frequent volume fluctuations, enabling adjustment of socket fit. We, thus, altered socket fit levels via addition/removal of sock layers to a transtibial amputee who habitually-donned two-sock layers to mimic relatively looser and tighter socket fits. Interface pressure and shear sensors were placed at known prominent load-bearing sites of the transtibial residuum/socket interface, i.e., patellar tendon (PT), popliteal fossa (PF), and anterior–distal (AD) end, to measure real-time biomechanical interactions during standing and level walking. Although socket fit level was only slightly modified, changes in interface pressure and shear across anatomical sites were still observed. Tighter fit corresponds to notable pressure reduction at AD during early stance and pressure increase at PT during terminal stance due to the residuum being pushed up. Shear-to-pressure ratios were used to assess comfort, while pressure– and shear–time integrals were used to assess tissue health. We observed more notable changes at tissue sites (e.g., AD and PF). Combined evaluation of pressure and shear, including shear-to-pressure ratio and time integrals, may offer insight for residuum care.
- Open Access
A Wearable Insole System to Measure Plantar Pressure and Shear for People with Diabetes
Pressure coupled with shear stresses are the critical external factors for diabetic foot ulceration assessment and prevention. To date, a wearable system capable of measuring in-shoe multi-directional stresses for out-of-lab analysis has been elusive. The lack of an insole system capable of measuring plantar pressure and shear hinders the development of an effective foot ulcer prevention solution that could be potentially used in a daily living environment. This study reports the development of a first-of-its-kind sensorised insole system and its evaluation in laboratory settings and on human participants, indicating its potential as a wearable technology to be used in real-world applications. Laboratory evaluation revealed that the linearity error and accuracy error of the sensorised insole system were up to 3% and 5%, respectively. When evaluated on a healthy participant, change in footwear resulted in approximately 20%, 75% and 82% change in pressure, medial–lateral and anterior–posterior shear stress, respectively. When evaluated on diabetic participants, no notable difference in peak plantar pressure, as a result of wearing the sensorised insole, was measured. The preliminary results showed that the performance of the sensorised insole system is comparable to previously reported research devices. The system has adequate sensitivity to assist footwear assessment relevant to foot ulcer prevention and is safe to use for people with diabetes. The reported insole system presents the potential to help assess diabetic foot ulceration risk in a daily living environment underpinned by wearable pressure and shear sensing technologies.
Open AccessA Wearable Insole System to Measure Plantar Pressure and Shear for People with Diabetes
Pressure coupled with shear stresses are the critical external factors for diabetic foot ulceration assessment and prevention. To date, a wearable system capable of measuring in-shoe multi-directional stresses for out-of-lab analysis has been elusive. The lack of an insole system capable of measuring plantar pressure and shear hinders the development of an effective foot ulcer prevention solution that could be potentially used in a daily living environment. This study reports the development of a first-of-its-kind sensorised insole system and its evaluation in laboratory settings and on human participants, indicating its potential as a wearable technology to be used in real-world applications. Laboratory evaluation revealed that the linearity error and accuracy error of the sensorised insole system were up to 3% and 5%, respectively. When evaluated on a healthy participant, change in footwear resulted in approximately 20%, 75% and 82% change in pressure, medial–lateral and anterior–posterior shear stress, respectively. When evaluated on diabetic participants, no notable difference in peak plantar pressure, as a result of wearing the sensorised insole, was measured. The preliminary results showed that the performance of the sensorised insole system is comparable to previously reported research devices. The system has adequate sensitivity to assist footwear assessment relevant to foot ulcer prevention and is safe to use for people with diabetes. The reported insole system presents the potential to help assess diabetic foot ulceration risk in a daily living environment underpinned by wearable pressure and shear sensing technologies.
- Open Access
- 12 July 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 236 (9) , 1349-1356
Analysis of lower limb prosthetic socket interface based on stress and motion measurements
The study was designed to establish a biomechanical assessment platform for the lower limb residuum/socket interface as a function of duration and speed of movement. The approach exploits an interface sensor which measures multi-directional stresses at the interface. The corresponding interface coupling motion was assessed using a 3D motion capture system. A longitudinal study, involving a trans-femoral amputee, was conducted with nine repeated level walking sessions over a 12-month period. The effect of walking speed on interface biomechanics was also assessed. Interface peak pressures and shear stresses in the range of 55–59 kPa and 12–19 kPa were measured, respectively, over all sessions in the 12 months study period at the posterior-proximal location of the residuum. The peak pressure and longitudinal shear values were found to fluctuate approximately 11% and 40% as against its maximum value, respectively, over 12 months. In addition, up to 12° of angular coupling and up to 28 mm of pistoning were recorded over a gait cycle, which was found to change by 29% and 45% respectively over the study period. The variation in walking speed, by altering self-selected cadence, resulted in changes of pressure and shear stresses at mid-stance of the gait cycle. In particular, as compared with self-selected cadence, for fast speed, peak pressure and peak longitudinal shear stress decreased by 5% and 33%, respectively. For slow speed, peak pressure and peak longitudinal shear stress increased by 7% and 17%, respectively. The corresponding angular and pistoning revealed a variation of up to 29% and 45%, respectively. This biomechanical assessment approach shows promise in the quantitative assessment of interface kinematics and kinetics for lower limb prosthetics, the usage of which could assist the clinical assessment of prosthetic socket fit.
- 12 July 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol. 236 (9) , 1349-1356
Open AccessAnalysis of lower limb prosthetic socket interface based on stress and motion measurements
The study was designed to establish a biomechanical assessment platform for the lower limb residuum/socket interface as a function of duration and speed of movement. The approach exploits an interface sensor which measures multi-directional stresses at the interface. The corresponding interface coupling motion was assessed using a 3D motion capture system. A longitudinal study, involving a trans-femoral amputee, was conducted with nine repeated level walking sessions over a 12-month period. The effect of walking speed on interface biomechanics was also assessed. Interface peak pressures and shear stresses in the range of 55–59 kPa and 12–19 kPa were measured, respectively, over all sessions in the 12 months study period at the posterior-proximal location of the residuum. The peak pressure and longitudinal shear values were found to fluctuate approximately 11% and 40% as against its maximum value, respectively, over 12 months. In addition, up to 12° of angular coupling and up to 28 mm of pistoning were recorded over a gait cycle, which was found to change by 29% and 45% respectively over the study period. The variation in walking speed, by altering self-selected cadence, resulted in changes of pressure and shear stresses at mid-stance of the gait cycle. In particular, as compared with self-selected cadence, for fast speed, peak pressure and peak longitudinal shear stress decreased by 5% and 33%, respectively. For slow speed, peak pressure and peak longitudinal shear stress increased by 7% and 17%, respectively. The corresponding angular and pistoning revealed a variation of up to 29% and 45%, respectively. This biomechanical assessment approach shows promise in the quantitative assessment of interface kinematics and kinetics for lower limb prosthetics, the usage of which could assist the clinical assessment of prosthetic socket fit.
- Open Access
- 4 January 2021
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 4 (1)
USING A SWEATING RESIDUUM/SOCKET INTERFACE SIMULATOR FOR THE EVALUATION OF SWEAT MANAGEMENT LINERS IN LOWER LIMB PROSTHETICS
BACKGROUND: Lab-based simulators can help to reduce variability in prosthetics research. However, they have not yet been used to investigate the effects of sweating at the residuum-liner interface. This work sought to create and validate a simulator to replicate the mechanics of residual limb perspiration. The developed apparatus was used to assess the effects of perspiration and different liner designs. METHODOLOGY: By scanning a cast, an artificial residuum was manufactured using a 3D-printed, transtibial bone model encased in silicone, moulded with pores. The pores allowed water to emit from the residuum surface, simulating sweating. Dry and sweating cyclic tests were performed by applying compressive and tensile loading, while measuring the displacement of the residuum relative to the socket. Tests were conducted using standard and perforated liners. FINDINGS: Although maximum displacement varied between test setups, its variance was low (coefficient of variation <1%) and consistent between dry tests. For unperforated liners, sweating increased the standard deviation of maximum displacement approximately threefold (0.04mm v 0.12mm, p<0.001). However, with the perforated liner, sweating had little effect on standard deviation compared to dry tests (0.04mm v 0.04mm, p=0.497). CONCLUSIONS: The test apparatus was effective at simulating the effect of perspiration at the residual limb. Moisture at the skin-liner interface can lead to inconsistent mechanics. Perforated liners help to remove sweat from the skin-liner interface, thereby mitigating these effects. Layman’s Abstract Simulators can be used in prosthetics research to make experiments more repeatable. In this study, a test apparatus was created to replicate the mechanical effects of residual limb sweating. An artificial residual limb was made from silicone and a 3D printed, transtibial bone model. Small holes were made throughout the silicone to act like pores, allowing water to travel to the outside surface, like sweat. The limb was loaded to mimic walking and its movement within the socket was measured. For some tests, water was added internally to see the effect of sweat. Two types of liner were used and compared; a standard one and one with perforations. In terms of movement, the results were generally consistent between each cycle for the dry tests. For standard liners, the addition of sweating increased the variability of movement approximately threefold (0.04mm v 0.12mm, p<0.001). However, with the perforated liner, sweating had little effect on movement (0.04mm v 0.04mm, p=0.497). The test apparatus simulated the effect of residual limb sweating. The findings indicate that moisture on the skin can lead to inconsistent movement, but perforated liners help to remove this moisture, which helps improve consistency of performance. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/35213/27472 How To Cite: McGrath M, Davies K.C, Gallego A, Laszczak P, Tang J, Zahedi S, Moser D. Using a sweating residuum/socket interface simulator for the evaluation of sweat management liners in lower limb prosthetics. Canadian Prosthetics & Orthotics Journal. 2021;Volume 4, Issue 1, No.3. https://doi.org/10.33137/cpoj.v4i1.35213 Corresponding Author: Dr. Michael McGrath, PhDResearch Scientist–Clinical Evidence,Blatchford Group, Unit D Antura, Bond Close, Basingstoke, RG24 8PZ, United Kingdom.Email: mike.mcgrath@blatchford.co.ukORCID: https://orcid.org/0000-0003-0195-970X
- 4 January 2021
- Published by University of Toronto Libraries - UOTL in CANADIAN PROSTHETICS & ORTHOTICS JOURNAL
- Vol. 4 (1)
Open AccessUSING A SWEATING RESIDUUM/SOCKET INTERFACE SIMULATOR FOR THE EVALUATION OF SWEAT MANAGEMENT LINERS IN LOWER LIMB PROSTHETICS
BACKGROUND: Lab-based simulators can help to reduce variability in prosthetics research. However, they have not yet been used to investigate the effects of sweating at the residuum-liner interface. This work sought to create and validate a simulator to replicate the mechanics of residual limb perspiration. The developed apparatus was used to assess the effects of perspiration and different liner designs. METHODOLOGY: By scanning a cast, an artificial residuum was manufactured using a 3D-printed, transtibial bone model encased in silicone, moulded with pores. The pores allowed water to emit from the residuum surface, simulating sweating. Dry and sweating cyclic tests were performed by applying compressive and tensile loading, while measuring the displacement of the residuum relative to the socket. Tests were conducted using standard and perforated liners. FINDINGS: Although maximum displacement varied between test setups, its variance was low (coefficient of variation <1%) and consistent between dry tests. For unperforated liners, sweating increased the standard deviation of maximum displacement approximately threefold (0.04mm v 0.12mm, p<0.001). However, with the perforated liner, sweating had little effect on standard deviation compared to dry tests (0.04mm v 0.04mm, p=0.497). CONCLUSIONS: The test apparatus was effective at simulating the effect of perspiration at the residual limb. Moisture at the skin-liner interface can lead to inconsistent mechanics. Perforated liners help to remove sweat from the skin-liner interface, thereby mitigating these effects. Layman’s Abstract Simulators can be used in prosthetics research to make experiments more repeatable. In this study, a test apparatus was created to replicate the mechanical effects of residual limb sweating. An artificial residual limb was made from silicone and a 3D printed, transtibial bone model. Small holes were made throughout the silicone to act like pores, allowing water to travel to the outside surface, like sweat. The limb was loaded to mimic walking and its movement within the socket was measured. For some tests, water was added internally to see the effect of sweat. Two types of liner were used and compared; a standard one and one with perforations. In terms of movement, the results were generally consistent between each cycle for the dry tests. For standard liners, the addition of sweating increased the variability of movement approximately threefold (0.04mm v 0.12mm, p<0.001). However, with the perforated liner, sweating had little effect on movement (0.04mm v 0.04mm, p=0.497). The test apparatus simulated the effect of residual limb sweating. The findings indicate that moisture on the skin can lead to inconsistent movement, but perforated liners help to remove this moisture, which helps improve consistency of performance. Article PDF Link: https://jps.library.utoronto.ca/index.php/cpoj/article/view/35213/27472 How To Cite: McGrath M, Davies K.C, Gallego A, Laszczak P, Tang J, Zahedi S, Moser D. Using a sweating residuum/socket interface simulator for the evaluation of sweat management liners in lower limb prosthetics. Canadian Prosthetics & Orthotics Journal. 2021;Volume 4, Issue 1, No.3. https://doi.org/10.33137/cpoj.v4i1.35213 Corresponding Author: Dr. Michael McGrath, PhDResearch Scientist–Clinical Evidence,Blatchford Group, Unit D Antura, Bond Close, Basingstoke, RG24 8PZ, United Kingdom.Email: mike.mcgrath@blatchford.co.ukORCID: https://orcid.org/0000-0003-0195-970X
- 10 January 2019
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 55 (11) , 1584-1587
Dioxygen activation with stable N-heterocyclic carbenes
Dioxygen activation with both cyclic (amino)(alkyl)carbenes and di(amino)carbenes at ambient temperature is described. Theoretical studies suggest that electron rearrangement from the doubly filled σ orbital of carbene carbon to its vacant p orbital through the π* antibonding orbital of 3O2 can be considered for Ccarbene–O bond formation.
- 10 January 2019
- Published by Royal Society of Chemistry (RSC) in Chemical Communications
- Vol. 55 (11) , 1584-1587
Dioxygen activation with stable N-heterocyclic carbenes
Dioxygen activation with both cyclic (amino)(alkyl)carbenes and di(amino)carbenes at ambient temperature is described. Theoretical studies suggest that electron rearrangement from the doubly filled σ orbital of carbene carbon to its vacant p orbital through the π* antibonding orbital of 3O2 can be considered for Ccarbene–O bond formation.
- 15 September 2017
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 49 (1) , 131-139
A combined kinematic and kinetic analysis at the residuum/socket interface of a knee-disarticulation amputee
The bespoke interface between a lower limb residuum and a prosthetic socket is critical for an amputee's comfort and overall rehabilitation outcomes. Analysis of interface kinematics and kinetics is important to gain full understanding of the interface biomechanics, which could aid clinical socket fit, rehabilitation and amputee care. This pilot study aims to investigate the dynamic correlation between kinematic movement and kinetic stresses at the interface during walking tests on different terrains. One male, knee disarticulation amputee participated in the study. He was asked to walk on both a level surface and a 5° ramped surface. The movement between the residuum and the socket was evaluated by the angular and axial couplings, based on the outputs from a 3D motion capture system. The corresponding kinetic stresses at anterior-proximal (AP), posterior-proximal (PP) and anterior-distal (AD) locations of the residuum were measured, using individual stress sensors. Approximately 8° of angular coupling and up to 32 mm of axial coupling were measured when walking on different terrains. The direction of the angular coupling shows strong correlation with the pressure difference between the PP and AP sensors. Higher pressure was obtained at the PP location than the AP location during stance phase, associated with the direction of the angular coupling. A strong correlation between axial coupling length, L, and longitudinal shear was also evident at the PP and AD locations i.e. the shortening of L corresponds to the increase of shear in the proximal direction. Although different terrains did not affect these correlations in principle, interface kinematic and kinetic values suggested that gait changes can induce modifications to the interface biomechanics. It is envisaged that the reported techniques could be potentially used to provide combined kinematics and kinetics for the understanding of biomechanics at the residuum/socket interface, which may play an important role in the clinical assessment of prosthetic component settings, including socket fit quality.
- 15 September 2017
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 49 (1) , 131-139
A combined kinematic and kinetic analysis at the residuum/socket interface of a knee-disarticulation amputee
The bespoke interface between a lower limb residuum and a prosthetic socket is critical for an amputee's comfort and overall rehabilitation outcomes. Analysis of interface kinematics and kinetics is important to gain full understanding of the interface biomechanics, which could aid clinical socket fit, rehabilitation and amputee care. This pilot study aims to investigate the dynamic correlation between kinematic movement and kinetic stresses at the interface during walking tests on different terrains. One male, knee disarticulation amputee participated in the study. He was asked to walk on both a level surface and a 5° ramped surface. The movement between the residuum and the socket was evaluated by the angular and axial couplings, based on the outputs from a 3D motion capture system. The corresponding kinetic stresses at anterior-proximal (AP), posterior-proximal (PP) and anterior-distal (AD) locations of the residuum were measured, using individual stress sensors. Approximately 8° of angular coupling and up to 32 mm of axial coupling were measured when walking on different terrains. The direction of the angular coupling shows strong correlation with the pressure difference between the PP and AP sensors. Higher pressure was obtained at the PP location than the AP location during stance phase, associated with the direction of the angular coupling. A strong correlation between axial coupling length, L, and longitudinal shear was also evident at the PP and AD locations i.e. the shortening of L corresponds to the increase of shear in the proximal direction. Although different terrains did not affect these correlations in principle, interface kinematic and kinetic values suggested that gait changes can induce modifications to the interface biomechanics. It is envisaged that the reported techniques could be potentially used to provide combined kinematics and kinetics for the understanding of biomechanics at the residuum/socket interface, which may play an important role in the clinical assessment of prosthetic component settings, including socket fit quality.