Jeroen Koelemeij
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jeroen Koelemeij has a total of 160 co-authors. Here are the top co-authors by number of shared publications:
- Wim Ubachs
Vrije Universiteit Amsterdam
16 shared publications - Jean-Philippe Karr
Laboratoire Kastler Brossel
12 shared publications L. Hilico
Laboratoire Kastler Brossel, UPMC–Sorbonne Université, CNRS, ENS-PSL Research University, Collège de France, 75005 Paris, France
9 shared publicationsJ. Biesheuvel
Vrije Universiteit
7 shared publications- Kjeld S. E. Eikema
Vrije Universiteit Amsterdam
7 shared publications S. Schiller
Institut für Experimentalphysik, Heinrich-Heine-Universität Düsseldorf; Germany
6 shared publications
Latest Publications
- 18 June 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (24) , 243001
Spectroscopy of He 4 at 0.25 ppt Uncertainty and Improved Alpha-Helion Charge-Radius Difference Determination
High-precision spectroscopy of simple atomic systems can be used to advance the theory of atomic energy levels but can also serve as a sensitive probe of nuclear charge radii. For this last purpose, we report an improved measurement of the 2^{3}S_{1}→2^{1}S_{0} transition frequency in ^{4}He with 48 Hz uncertainty (0.25 ppt), using a Bose-Einstein condensed sample confined in a magic-wavelength optical dipole trap. A systematic Doppler shift from condensate motion is suppressed by time-resolved ion detection, and the transition frequency is calibrated via a White Rabbit link to a remote active hydrogen maser clock. Combined with previous ^{3}He measurements and improved theory, we obtain the most precise determination to date of the charge-radius difference between the helion and alpha particle (r_{h}^{2}-r_{α}^{2}) of 1.0676(10) fm^{2}. This is consistent with other recent determinations and confirms that the current discrepancy between QED theory and experimentally observed ionization energies of excited states in helium is not apparent in the isotope shift.
- 18 June 2026
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 136 (24) , 243001
Spectroscopy of He 4 at 0.25 ppt Uncertainty and Improved Alpha-Helion Charge-Radius Difference Determination
High-precision spectroscopy of simple atomic systems can be used to advance the theory of atomic energy levels but can also serve as a sensitive probe of nuclear charge radii. For this last purpose, we report an improved measurement of the 2^{3}S_{1}→2^{1}S_{0} transition frequency in ^{4}He with 48 Hz uncertainty (0.25 ppt), using a Bose-Einstein condensed sample confined in a magic-wavelength optical dipole trap. A systematic Doppler shift from condensate motion is suppressed by time-resolved ion detection, and the transition frequency is calibrated via a White Rabbit link to a remote active hydrogen maser clock. Combined with previous ^{3}He measurements and improved theory, we obtain the most precise determination to date of the charge-radius difference between the helion and alpha particle (r_{h}^{2}-r_{α}^{2}) of 1.0676(10) fm^{2}. This is consistent with other recent determinations and confirms that the current discrepancy between QED theory and experimentally observed ionization energies of excited states in helium is not apparent in the isotope shift.
- Open Access
- 12 June 2026
- Published by Optica Publishing Group in Optica
- Vol. 13 (7) , 1355
Optically Derived Radio-Frequency Benchmark in Methanol: A Sub-kHz Reference for Astrophysical Tests of Fundamental Physics
Methanol radio lines observed in space provide sensitive probes of whether the proton-to-electron mass ratio has changed over cosmic time, but such tests require laboratory rest frequencies with very high accuracy. Here, we determine the frequency of the astrophysically important 12.2 GHz 3 −1 E−2 0 E transition of CH 3 OH by measuring near-infrared rovibrational transitions rather than the microwave line directly. Using wavelength-modulated NICE-OHMS locked to an ultra-stable optical frequency comb and referenced via a fiber link to a hydrogen-maser frequency standard, we measure Lamb-dip frequencies near 1.4 µm (216 THz) with 10 Hz statistical reproducibility and absolute uncertainties as low as 130 Hz. Pairs of optical transitions sharing common upper levels form a triangulation scheme that yields the ground-state rotational combination difference. We obtain 12,178,596.415(135) kHz, improving on earlier molecular-beam microwave spectroscopy by a factor of 20 and agreeing with a recent free-induction-decay measurement. This result establishes a sub-kHz laboratory benchmark for a key radio-astronomical methanol line and demonstrates that optical triangulation can be extended to non-chiral molecules with internal rotation.
- 12 June 2026
- Published by Optica Publishing Group in Optica
- Vol. 13 (7) , 1355
Open AccessOptically Derived Radio-Frequency Benchmark in Methanol: A Sub-kHz Reference for Astrophysical Tests of Fundamental Physics
Methanol radio lines observed in space provide sensitive probes of whether the proton-to-electron mass ratio has changed over cosmic time, but such tests require laboratory rest frequencies with very high accuracy. Here, we determine the frequency of the astrophysically important 12.2 GHz 3 −1 E−2 0 E transition of CH 3 OH by measuring near-infrared rovibrational transitions rather than the microwave line directly. Using wavelength-modulated NICE-OHMS locked to an ultra-stable optical frequency comb and referenced via a fiber link to a hydrogen-maser frequency standard, we measure Lamb-dip frequencies near 1.4 µm (216 THz) with 10 Hz statistical reproducibility and absolute uncertainties as low as 130 Hz. Pairs of optical transitions sharing common upper levels form a triangulation scheme that yields the ground-state rotational combination difference. We obtain 12,178,596.415(135) kHz, improving on earlier molecular-beam microwave spectroscopy by a factor of 20 and agreeing with a recent free-induction-decay measurement. This result establishes a sub-kHz laboratory benchmark for a key radio-astronomical methanol line and demonstrates that optical triangulation can be extended to non-chiral molecules with internal rotation.
- Open Access
- 16 March 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (3)
Quasicontinuous sub- μ K strontium source without a high-finesse cavity-stabilized laser
We demonstrate a quasicontinuous sub- μ K strontium source achieved without the use of a high-finesse cavity-locked laser. Our frequency reference is based on a dispersion-optimized, fiber-based frequency comb that enables sub-kHz linewidths. The long-term stability of the comb is defined by an external rf reference: either a 10 MHz rf signal from the Dutch Metrology Institute (VSL) or a tunable rf source whose long-term stability is maintained by monitoring and stabilizing the position of a narrow-line magneto-optical trap (MOT) [Sillus , Rev. Sci. Instrum., 92, 033204 (2021); Heizenreder , Continuous cloud position spectroscopy using a magneto-optical trap, Phys. Rev. Appl. (2026)]. The comb-stabilized system is benchmarked against a conventional cavity-locked laser and achieves comparable performance in broadband and single-frequency MOTs using the narrow 1 S 0 → 3 P 1 laser-cooling transition. We generate high-flux, sub- μ K samples of all three bosonic strontium isotopes and demonstrate quasicontinuous outcoupling from the MOT. These results highlight the system’s suitability for compact, robust, and field-deployable continuous cold-atom devices.
- 16 March 2026
- Published by American Physical Society (APS) in Physical Review Applied
- Vol. 25 (3)
Open AccessQuasicontinuous sub- μ K strontium source without a high-finesse cavity-stabilized laser
We demonstrate a quasicontinuous sub- μ K strontium source achieved without the use of a high-finesse cavity-locked laser. Our frequency reference is based on a dispersion-optimized, fiber-based frequency comb that enables sub-kHz linewidths. The long-term stability of the comb is defined by an external rf reference: either a 10 MHz rf signal from the Dutch Metrology Institute (VSL) or a tunable rf source whose long-term stability is maintained by monitoring and stabilizing the position of a narrow-line magneto-optical trap (MOT) [Sillus , Rev. Sci. Instrum., 92, 033204 (2021); Heizenreder , Continuous cloud position spectroscopy using a magneto-optical trap, Phys. Rev. Appl. (2026)]. The comb-stabilized system is benchmarked against a conventional cavity-locked laser and achieves comparable performance in broadband and single-frequency MOTs using the narrow 1 S 0 → 3 P 1 laser-cooling transition. We generate high-flux, sub- μ K samples of all three bosonic strontium isotopes and demonstrate quasicontinuous outcoupling from the MOT. These results highlight the system’s suitability for compact, robust, and field-deployable continuous cold-atom devices.
- Open Access
- 3 January 2026
- Published by Springer Nature in Experimental Astronomy
- Vol. 61 (1) , 3
White Rabbit in radio interferometry
Radio interferometry relies on distributed telescopes having precise time and frequency sources that allow them to operate coherently over timescales up to several hours. As radio telescopes are being connected to fiber-based high-speed communication networks, it is of interest to make use of these for time and frequency distribution. The White Rabbit protocol enables the accurate and precise distribution of time and frequency signals over telecommunication optical fibers. We set out to evaluate the quantitative limits for interferometers over a range of observing frequencies when synchronized through White Rabbit. We develop a method to quantify the possible loss of sensitivity due to the phase noise contribution of a White Rabbit link. Our findings include a new expression for the coherence loss due to flicker phase noise. As this type of noise is common in frequency transfer links, its use extends beyond the case of White Rabbit. Furthermore, we designed a calibration procedure to measure the dispersion on already deployed fiber networks. We demonstrate adding a White Rabbit signal to an existing high-speed production network, together with data traffic on other wavelengths on the same fiber. Finally we built a VLBI setup with fiber links of 35 and 169 km, connecting two radio telescopes together. The agreement between our predicted and measured coherence loss indicates the usefulness of our approach, and that White Rabbit is suitable for clock distribution in radio interferometry instruments. We find that regular White Rabbit v3 switches support observing frequencies up to 3.5 GHz, and their low-jitter version up to 15 GHz.
- 3 January 2026
- Published by Springer Nature in Experimental Astronomy
- Vol. 61 (1) , 3
Open AccessWhite Rabbit in radio interferometry
Radio interferometry relies on distributed telescopes having precise time and frequency sources that allow them to operate coherently over timescales up to several hours. As radio telescopes are being connected to fiber-based high-speed communication networks, it is of interest to make use of these for time and frequency distribution. The White Rabbit protocol enables the accurate and precise distribution of time and frequency signals over telecommunication optical fibers. We set out to evaluate the quantitative limits for interferometers over a range of observing frequencies when synchronized through White Rabbit. We develop a method to quantify the possible loss of sensitivity due to the phase noise contribution of a White Rabbit link. Our findings include a new expression for the coherence loss due to flicker phase noise. As this type of noise is common in frequency transfer links, its use extends beyond the case of White Rabbit. Furthermore, we designed a calibration procedure to measure the dispersion on already deployed fiber networks. We demonstrate adding a White Rabbit signal to an existing high-speed production network, together with data traffic on other wavelengths on the same fiber. Finally we built a VLBI setup with fiber links of 35 and 169 km, connecting two radio telescopes together. The agreement between our predicted and measured coherence loss indicates the usefulness of our approach, and that White Rabbit is suitable for clock distribution in radio interferometry instruments. We find that regular White Rabbit v3 switches support observing frequencies up to 3.5 GHz, and their low-jitter version up to 15 GHz.
- Open Access
Extraction of spin-averaged rovibrational transition frequencies in HD$^+$ for the determination of fundamental constants
We present a comprehensive analysis of all currently available high-accuracy frequency measurements of rotational and rovibrational transitions in the hydrogen molecular ion HD$^+$. Our analysis utilises the theoretically calculated hyperfine structure to extract the values of three spin-averaged transition frequencies through a global linear least-squares adjustment that takes into account theory-induced correlations between the different transitions. We subsequently use the three spin-averaged transition frequencies as input data in a second adjustment which employs precise theoretical expressions for the transition frequencies, written as a function of the proton, deuteron and electron relative atomic masses, the Rydberg constant, and the proton and deuteron charge radii. Our analysis shows that the HD$^+$ data may significantly improve the value of the electron relative atomic mass and the proton-electron mass ratio, in particular if combined with recent high-precision measurements of particle atomic masses and mass ratios obtained from Penning traps.
Open AccessExtraction of spin-averaged rovibrational transition frequencies in HD$^+$ for the determination of fundamental constants
We present a comprehensive analysis of all currently available high-accuracy frequency measurements of rotational and rovibrational transitions in the hydrogen molecular ion HD$^+$. Our analysis utilises the theoretically calculated hyperfine structure to extract the values of three spin-averaged transition frequencies through a global linear least-squares adjustment that takes into account theory-induced correlations between the different transitions. We subsequently use the three spin-averaged transition frequencies as input data in a second adjustment which employs precise theoretical expressions for the transition frequencies, written as a function of the proton, deuteron and electron relative atomic masses, the Rydberg constant, and the proton and deuteron charge radii. Our analysis shows that the HD$^+$ data may significantly improve the value of the electron relative atomic mass and the proton-electron mass ratio, in particular if combined with recent high-precision measurements of particle atomic masses and mass ratios obtained from Penning traps.
- Open Access
- 24 March 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 130 (12) , 121801
Self-Consistent Extraction of Spectroscopic Bounds on Light New Physics
Fundamental physical constants are determined from a collection of precision measurements of elementary particles, atoms, and molecules. This is usually done under the assumption of the standard model (SM) of particle physics. Allowing for light new physics (NP) beyond the SM modifies the extraction of fundamental physical constants. Consequently, setting NP bounds using these data, and at the same time assuming the Committee on Data of the International Science Council recommended values for the fundamental physical constants, is not reliable. As we show in this Letter, both SM and NP parameters can be simultaneously determined in a consistent way from a global fit. For light vectors with QED-like couplings, such as the dark photon, we provide a prescription that recovers the degeneracy with the photon in the massless limit and requires calculations only at leading order in the small new physics couplings. At present, the data show tensions partially related to the proton charge radius determination. We show that these can be alleviated by including contributions from a light scalar with flavor nonuniversal couplings.
- 24 March 2023
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 130 (12) , 121801
Open AccessSelf-Consistent Extraction of Spectroscopic Bounds on Light New Physics
Fundamental physical constants are determined from a collection of precision measurements of elementary particles, atoms, and molecules. This is usually done under the assumption of the standard model (SM) of particle physics. Allowing for light new physics (NP) beyond the SM modifies the extraction of fundamental physical constants. Consequently, setting NP bounds using these data, and at the same time assuming the Committee on Data of the International Science Council recommended values for the fundamental physical constants, is not reliable. As we show in this Letter, both SM and NP parameters can be simultaneously determined in a consistent way from a global fit. For light vectors with QED-like couplings, such as the dark photon, we provide a prescription that recovers the degeneracy with the photon in the massless limit and requires calculations only at leading order in the small new physics couplings. At present, the data show tensions partially related to the proton charge radius determination. We show that these can be alleviated by including contributions from a light scalar with flavor nonuniversal couplings.
- 16 November 2022
- Published by Springer Nature in Nature
- Vol. 611 (7936) , 473-478
A hybrid optical–wireless network for decimetre-level terrestrial positioning
Global navigation satellite systems (GNSS) are widely used for navigation and time distribution1,2,3, features that are indispensable for critical infrastructure such as mobile communication networks, as well as emerging technologies such as automated driving and sustainable energy grids3,4. Although GNSS can provide centimetre-level precision, GNSS receivers are prone to many-metre errors owing to multipath propagation and an obstructed view of the sky, which occur particularly in urban areas where accurate positioning is most needed1,5,6. Moreover, the vulnerabilities of GNSS, combined with the lack of a back-up system, pose a severe risk to GNSS-dependent technologies7. Here we demonstrate a terrestrial positioning system that is independent of GNSS and offers superior performance through a constellation of radio transmitters, connected and time-synchronized at the subnanosecond level through a fibre-optic Ethernet network8. Using optical and wireless transmission schemes similar to those encountered in mobile communication networks, and exploiting spectrally efficient virtual wideband signals, the detrimental effects of multipath propagation are mitigated9, thus enabling robust decimetre-level positioning and subnanosecond timing in a multipath-prone outdoor environment. This work provides a glimpse of a future in which telecommunication networks provide not only connectivity but also GNSS-independent timing and positioning services with unprecedented accuracy and reliability.
- 16 November 2022
- Published by Springer Nature in Nature
- Vol. 611 (7936) , 473-478
A hybrid optical–wireless network for decimetre-level terrestrial positioning
Global navigation satellite systems (GNSS) are widely used for navigation and time distribution1,2,3, features that are indispensable for critical infrastructure such as mobile communication networks, as well as emerging technologies such as automated driving and sustainable energy grids3,4. Although GNSS can provide centimetre-level precision, GNSS receivers are prone to many-metre errors owing to multipath propagation and an obstructed view of the sky, which occur particularly in urban areas where accurate positioning is most needed1,5,6. Moreover, the vulnerabilities of GNSS, combined with the lack of a back-up system, pose a severe risk to GNSS-dependent technologies7. Here we demonstrate a terrestrial positioning system that is independent of GNSS and offers superior performance through a constellation of radio transmitters, connected and time-synchronized at the subnanosecond level through a fibre-optic Ethernet network8. Using optical and wireless transmission schemes similar to those encountered in mobile communication networks, and exploiting spectrally efficient virtual wideband signals, the detrimental effects of multipath propagation are mitigated9, thus enabling robust decimetre-level positioning and subnanosecond timing in a multipath-prone outdoor environment. This work provides a glimpse of a future in which telecommunication networks provide not only connectivity but also GNSS-independent timing and positioning services with unprecedented accuracy and reliability.
- Open Access
- 2 April 2022
- Published by Taylor & Francis in Molecular Physics
- Vol. 120 (19-20)
Effect of correlated hyperfine theory errors in the determination of rotational and vibrational transition frequencies in HD+
We revisit the problem of separating the purely rovibrational and hyperfine contributions to observed rovibrational transition frequencies. The separation of hyperfine frequency shifts played an essential role in recent works in which the value of the proton-electron mass ratio was determined from Doppler-free rovibrational spectroscopy and high-precision theory of the molecular ion. Here, we present an alternative approach to removing theoretically computed hyperfine shifts from a limited set of observed rovibrational transition frequencies, based on a least-squares adjustment. The adjustment facilitates a quantitative study of the effect of correlations between the uncertainties of lower- and upper-state hyperfine energies on the derived value of the rovibrational transition frequency. We find that correlations may lead to significant shifts of the extracted rovibrational transition frequencies. In addition, we propose and demonstrate a method to quantify the additional shift and uncertainty, which is of importance to other applications of the spectroscopic data, such as the determination of fundamental physical constants. GRAPHICAL ABSTRACT- 2 April 2022
- Published by Taylor & Francis in Molecular Physics
- Vol. 120 (19-20)
Open AccessEffect of correlated hyperfine theory errors in the determination of rotational and vibrational transition frequencies in HD+
We revisit the problem of separating the purely rovibrational and hyperfine contributions to observed rovibrational transition frequencies. The separation of hyperfine frequency shifts played an essential role in recent works in which the value of the proton-electron mass ratio was determined from Doppler-free rovibrational spectroscopy and high-precision theory of the molecular ion. Here, we present an alternative approach to removing theoretically computed hyperfine shifts from a limited set of observed rovibrational transition frequencies, based on a least-squares adjustment. The adjustment facilitates a quantitative study of the effect of correlations between the uncertainties of lower- and upper-state hyperfine energies on the derived value of the rovibrational transition frequency. We find that correlations may lead to significant shifts of the extracted rovibrational transition frequencies. In addition, we propose and demonstrate a method to quantify the additional shift and uncertainty, which is of importance to other applications of the spectroscopic data, such as the determination of fundamental physical constants. GRAPHICAL ABSTRACT - Open Access
- 28 June 2021
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 3 (2) , L022028
Three-body QED test and fifth-force constraint from vibrations and rotations ofWe present a parts-per-million test of quantum electrodynamics (QED) in the molecular hydrogen ion, improving on previous tests based on vibrational and rotational transitions by factors of 76 and 1.4, respectively. The test is performed following a unified statistical approach that also produces improved constraints on physics beyond the standard model. We furthermore show how individual constraints derived from the various degrees of freedom in and antiprotonic helium can be combined to enhance the sensitivity, thus ruling out “fifth forces” on the Ångstrom scale that are times weaker than the electromagnetic interaction.- 28 June 2021
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 3 (2) , L022028
Open AccessThree-body QED test and fifth-force constraint from vibrations and rotations ofWe present a parts-per-million test of quantum electrodynamics (QED) in the molecular hydrogen ion, improving on previous tests based on vibrational and rotational transitions by factors of 76 and 1.4, respectively. The test is performed following a unified statistical approach that also produces improved constraints on physics beyond the standard model. We furthermore show how individual constraints derived from the various degrees of freedom in and antiprotonic helium can be combined to enhance the sensitivity, thus ruling out “fifth forces” on the Ångstrom scale that are times weaker than the electromagnetic interaction. - 4 September 2020
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 369 (6508) , 1238-1241
Proton-electron mass ratio from laser spectroscopy of HD + at the part-per-trillion level
A very precise ratio: The value of the ratio of the masses of the proton and the electron has a bearing on the values of other physical constants. This ratio is known to a very high precision. Patra et al. improved this precision even further by measuring particular frequencies in the rovibrational spectrum of the hydrogen deuteride molecular ion (HD + ) (see the Perspective by Hori). To reach this high precision, the researchers placed the HD + molecules in an ion trap and surrounded them by beryllium ions. The cold beryllium ions then helped cool the HD + molecules, making the HD + spectral lines narrow enough that the proton-electron mass ratio could be extracted by comparison with theoretical predictions. Science , this issue p. 1238 ; see also p. 1160
- 4 September 2020
- Published by American Association for the Advancement of Science (AAAS) in Science
- Vol. 369 (6508) , 1238-1241
Proton-electron mass ratio from laser spectroscopy of HD + at the part-per-trillion level
A very precise ratio: The value of the ratio of the masses of the proton and the electron has a bearing on the values of other physical constants. This ratio is known to a very high precision. Patra et al. improved this precision even further by measuring particular frequencies in the rovibrational spectrum of the hydrogen deuteride molecular ion (HD + ) (see the Perspective by Hori). To reach this high precision, the researchers placed the HD + molecules in an ion trap and surrounded them by beryllium ions. The cold beryllium ions then helped cool the HD + molecules, making the HD + spectral lines narrow enough that the proton-electron mass ratio could be extracted by comparison with theoretical predictions. Science , this issue p. 1238 ; see also p. 1160