BSBernhard Steger

Bernhard Steger

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bernhard Steger has a total of 162 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Standardising ocular surface photography for artificial intelligence: current limitations and a proposed roadmap

    by Vito Romano, Bernhard Steger, Matteo Airaldi, Ferdinando Giuliano, Mariantonia Ferrara, Davide Romano, Mario R. Romano, Yalin Zheng, Darren S.J. Ting

  • Open Access

    Lymphatic corneal neovascularisation affects graft survival in high-risk corneal transplantation

    by Nadja Franz, Christoph Palme, Alexander Franchi, Victoria Stöckl, Christof Seifarth, Gertrud Haas, Matus Rehak, Bernhard Steger

    Objectives: Corneal neovascularisation (CoNV) is a major risk factor for corneal allograft rejection and failure. This study assessed the impact of preoperative lymphatic and haematic vascularisation of the graft bed on graft survival in a clinical setting. Methods and analysis: This retrospective study included patients with histologically confirmed CoNV (positive staining for CD-31) who underwent penetrating keratoplasty (PK) between 2008 and 2023 at the Medical University of Innsbruck, Austria. Cases were divided into two groups depending on the presence or absence of lymphatic CoNV (podoplanin staining). Follow-up was 2 years or until graft failure. Outcome parameters included the risk of graft failure and leakage patterns in a subgroup with preoperative indocyanine green (ICG) angiography. Results: Of 17 included patients, lymphatic CoNV was identified in the excised corneal buttons of 10 cases (group 1). Seven cases stained only for haematic CoNV (group 2). Group 1 had a shorter age of CoNV (0.6±0.4 vs 2.3±0.8 years, p<0.001) and a higher rate of graft failure (6/10 vs 0/7, p=0.005). Lymphatic CoNV was only present in the age of CoNV less than 12 months. ICG leakage was associated with a younger age of CoNV (p=0.0338), corresponding to the presence of lymphatic CoNV at a younger age of CoNV. Conclusion: Lymphatic CoNV in haemvascularised corneal stromal beds increases the risk of graft failure within 2 years. Lymphatic CoNV regression occurs within the first year of an inciting event. This time period or the presence of ICG dye leakage indicates a very high risk for corneal transplantation.


  • Open Access

    Corneal transplantation: the fine line between donor shortage and tissue quality

    by Bernhard Steger, Stephen B Kaye, Vito Romano


  • Open Access

    Data Exchange Standards in Teleophthalmology: Current and Future Developments

    by Marco Schweitzer, Bernhard Steger, Alexander Hoerbst, Marco Augustin, Bernhard Pfeifer, Ulrich Hausmann, Daniel Baumgarten

    Background: Teleophthalmology services are considered capable of supporting screening, early diagnosis, and monitoring of leading causes of blindness on a global scale. Therefore, standards and best practices are needed to seamlessly exchange medical ocular images and related data among relevant stakeholders with maximum interoperability. Objectives: This paper provides an overview of current standards in the field of store-and-forward teleophthalmology data exchange and further developments in this area. Methods: A literature review was conducted for healthcare standards with a focus on data exchange in ophthalmology. Results: IHE, HL7 FHIR, DICOM, and clinical terminologies are considered the most important standards, providing distinct concepts, solutions, and guidelines for ophthalmology. Conclusion: Available standards provide the necessary base for teleophthalmology on technical and semantic interoperability, but practical use is limited due to missing process interoperability resulting in proprietary interfaces of vendors and rejection by ophthalmologists. Further investigations should analyze processual needs on ophthalmology data exchange standards.


  • Imaging of vascular abnormalities in ocular surface disease

    by Vito Romano, Bernhard Steger, Mohammad Ahmad, Giulia Coco, Luca Pagano, Sajjad Ahmad, Yitian Zhao, Yalin Zheng, Stephen B Kaye


  • Open Access

    Effects of COVID-19 protective measures on the ophthalmological patient examination with an emphasis on gender-specific differences

    by Teresa Rauchegger, Antonia Osl, Yvonne Nowosielski, Reinhard Angermann, Christoph Palme, Gertrud Haas, Bernhard Steger

    Objective In response to the COVID-19 pandemic, strict hygiene and containment measures have been instituted in the clinical ophthalmological examination to prevent virus transmission. The aim of this study is to assess the effects of these protective measures on the quality of the examination with an emphasis on gender-specific differences. Methods and analysis An online survey was sent to ophthalmologists in 10 countries. The collected data included demographics, place of work, current professional status, COVID-19 protective measures and their impact on the quality of the examination. Descriptive statistics were used to analyse the data. Fisher’s exact test was used to analyse gender differences. Results A total of 120 responses were collected. 54.0% of the respondents identified as female and 43.4% as male. Over 75% agreed that protective measures made the examination conditions more difficult. The major problems were fogging of the lenses (87.6%) or slit lamp oculars (69.9%), reduced operability of the slit lamp due to protective barriers (60.2%) and time delay due to disinfection measures (68.1%). Significantly more women than men reported that they used filtering face piece (FFP2) instead of surgical masks (p=0.02). More male participants reported that they removed their mask to prevent fogging (p=0.01). 31% of all participants felt that the COVID-19 protective measures reduced the overall quality of slit lamp examination and 43.4% reported a reduced quality of fundoscopic examination. Conclusion COVID-19 related safety measures reduce the feasibility of the clinical ophthalmological examination. Practicable solutions are required to maintain good examination quality without compromising personal safety.


  • Open Access

    Ocular surface angiography: from neovessels to neoplasia

    by Bernhard Steger

    The ocular surface vascular system plays a key role in corneal and conjunctival inflammatory, infectious and neoplastic pathology. Angiographic vessel analysis using intravenous dyes and optical coherence tomography technology allow both the quantitative and functional assessment of conjunctival vasculature and corneal neovessels. Based on a thorough understanding of vascular alterations in ocular surface disease, angiographic assessment facilitates the clinical management of corneal neovascularisation, the grading of ocular surface inflammation and the identification of tumour angiogenesis in dysplastic or malignant lesions. This review summarises key aspects of the clinical application of corneal and conjunctival angiography as presented at the 2021 virtual Bowman Club meeting.


  • Indocyanine Green Angiographic Assessment of Conjunctival Melanocytic Disorders

    by Christoph Palme, Astrid Wanner, Vito Romano, Alexander Franchi, Gertrud Haas, Stephen B. Md Kaye, Bernhard Steger

    Purpose: To investigate whether transvascular indocyanine green (ICG) dye leakage is associated with conjunctival malignancy. Methods: This is a prospective interventional study. Patients presenting with circumscribed conjunctival melanocytic disorders (CMDs) were included and examined using color photography, anterior segment optical coherence tomography to measure lesion size, and fluorescein and ICG angiography to measure vascular pattern and leakage. Time to vascular leakage was measured by 2 independent observers. Lesions were characterized as benign or malignant based on histopathological features. Results: Thirty patients with CMD were included: 22 lesions were benign (conjunctival nevus, n = 20; conjunctival melanocytic intraepithelial neoplasia without atypia, n = 2) and 8 were malignant (in situ conjunctival melanoma n = 2; invasive conjunctival melanoma, n = 6). Malignant lesions had larger mean maximal diameters (11.0 ± 4.5 vs. 4.2 ± 2.5 mm, P = 0.003) and more frequently showed intrinsic tumor vasculature (8 of 8 vs. 10 of 22, P = 0.007). The mean time to ICG leakage was 350.9 ± 165.9 seconds in benign and 59.6 ± 22.1 seconds (P = 0.002) in malignant lesions and was inversely correlated with lesion size and thickness. Conclusions: Time to angiographic ICG dye leakage is significantly shorter in malignant versus benign CMD.


  • Open Access

    Observation of angiographic dye leakage in ocular surface squamous neoplasia

    by Christoph Palme, Astrid Wanner, Vito Romano, Gertrud Haas, Stephen Kaye, Bernhard Steger


  • Open Access

    Eye bank versus surgeon prepared DMEK tissues: influence on adhesion and re-bubbling rate

    by Vito Romano, Ahmed Kazaili, Luca Pagano, Kunal Ajit Gadhvi, Mitchell Titley, Bernhard Steger, Luis Fernández-Vega-Cueto, Alvaro Meana, Jesus Merayo-Lloves, Ponzin Diego, et al.

    Aim To investigate the difference in adhesion and rebubbling rate between eye bank and surgeon prepared Descemet membrane endothelial keratoplasty (DMEK) tissues. Methods Laboratory and clinical retrospective comparative interventional case series. Research corneal tissues were obtained for laboratory investigation. The clinical study involved patients with endothelial dysfunction who underwent DMEK surgery and tamponade with air. Tissues were stripped using a standard DMEK stripping technique (SCUBA) and shipped as prestripped or loaded in a 2.2 intra-ocular lens cartridge with endothelium facing inwards (preloaded) before transporting from the eye bank to the surgeon. For surgeon prepared tissues, all the grafts were stripped in the theatre and transplanted or stripped in the laboratory and tested immediately. Adhesion force and elastic modulus were measured in the centre and mid-periphery in a laboratory ex vivo investigation using atomic force microscopy, while rebubbling rates were recorded in the clinical study. Results There was no difference in endothelial cell viability between surgeon or eye bank prepared tissue. Surgeon-stripped DMEK grafts in the laboratory investigation showed significantly higher elastic modulus and adhesion force compared to prestripped and preloaded tissues (pConclusions Decreased adhesion forces and elastic modulus in eye bank prepared tissues may contribute to increased rebubbling rates.