KMKelly S. Myers

Kelly S. Myers

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Kelly S. Myers has a total of 67 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Timeliness of an Expedited Diagnostic Pathway for Screening Mammography Recalls

    by Babita Panigrahi, Swathi Raman, Lisa A. Mullen, Kelly S. Myers, Katharine Yao, Emily B. Ambinder

  • Open Access

    Real-world performance of a Food and Drug Administration–approved artificial intelligence tool for mammography in patients with prior breast surgery or indwelling biopsy clips

    by Emily B Ambinder, Colin Paulbeck, Shuchi Zinzuwadia, Lisa Mullen, Kelly S Myers, Eniola Oluyemi, Babita Panigrahi

    Background: Artificial intelligence (AI) tools are increasingly used in clinical screening mammography, but their performance in patients with prior breast surgery or indwelling biopsy clips, who represent a substantial proportion of screening populations, has not been well characterized. Purpose: To evaluate the real-world performance of an Food and Drug Administration–approved AI mammography tool in patients with prior breast surgery or biopsy clips. Methods and Materials: We retrospectively reviewed all screening mammograms performed at our institution between August 1, 2024, and February 28, 2025, after implementation of a commercially available AI tool (Transpara 1.7.4-A), merging clinical outcomes with the AI risk score (low, intermediate, or elevated). Patients were stratified by procedural history into 3 groups: prior breast surgery, biopsy clip, and reference (ie, neither intervention). Sensitivity, positive predictive value (PPV), and false positive rate (FPR) at the elevated and intermediate + elevated thresholds were compared using Fisher exact tests presented as percentage (95% confidence interval [CI]). Results: A total of 24 427 screening mammograms were included (mean age 61 ± 13 years): 19 287 in the reference group, 2647 in the surgery group, and 2493 in the biopsy clip group. AI sensitivity at the intermediate + elevated threshold was preserved (reference 92.1% [95% CI, 86.9%-95.3%], surgery 90.5% [95% CI, 71.1%-97.3%], biopsy clip 90.0% [95% CI, 69.9%-97.2%]; both P > .6). The AI-PPV of an elevated exam was correspondingly reduced in altered-breast patients (reference 13.6% [95% CI, 11.1%-16.6%], surgery 5.5% [95% CI, 2.9%-10.0%], biopsy clip 4.9% [95% CI, 2.5%-9.4%]; both P < .005 vs reference). The AI-FPR was higher in both subgroups at the intermediate + elevated threshold (reference 35.6% [95% CI, 34.9%-36.3%] vs surgery 47.9% [95% CI, 46.0%-49.9%] and biopsy clip 47.9% [95% CI, 45.9%-49.8%]; both P < .001) and more than doubled at the elevated threshold (reference 2.7% [95% CI, 2.5%-2.9%] vs surgery 5.9% [95% CI, 5.1%-6.9%] and biopsy clip 6.2% [95% CI, 5.3%-7.2%]; both P < .001). Conclusion: AI examination–level sensitivity for breast cancer was preserved in patients with prior breast surgery or indwelling biopsy clips. However, an elevated AI risk score was less likely to reflect a cancer in these patients than in the reference group, with a lower AI-PPV and higher AI-FPR.

  • Breast Cancer Method of Detection: Screening Associated With Favorable Tumor Characteristics, Treatment, and Survival Across Age Groups

    by Babita Panigrahi, Alexandra DiTommaso, Naveen Ghuman, Kelly S. Myers, Lisa A. Mullen, Emily B. Ambinder, Eniola T. Oluyemi


  • Open Access

    AutoSOUL: Deep Convolutional Neural Network for Autonomous Selection of Ultrasound Speckle Tracking Parameters

    by Md Ashikuzzaman, Jahin Alam, Ahmed El-Desoky, Eniola Oluyemi, Kelly Myers, Emily Ambinder, Muyinatu A. Lediju Bell

    In medical diagnostics, ultrasound strain elastography offers a non-invasive method to assess tissue stiffness, aiding in distinguishing tumors, cysts, and benign lesions from healthy tissue. A strain elastography framework employs a speckle-tracking technique to estimate the displacement between pre- and post-compression radiofrequency (RF) frames, which is spatially differentiated to calculate the strain field. Second-order ultrasound elastography (SOUL) is a recently published speckle-tracking algorithm that optimizes a regularized cost function comprising data fidelity and regularization terms. However, the success of SOUL to produce high-quality strain images depends on the manual selection of regularization parameters, making it user-dependent and limiting its efficiency and usability. To mitigate this manual parameter selection, herein, we propose AutoSOUL, a deep convolutional neural network (CNN)-based framework, to autonomously select the optimal regularization parameters of SOUL. A custom-designed CNN was trained on simulated datasets and fine-tuned on phantom datasets to classify a strain image as acceptable or unacceptable and predict the optimal strain image and parameter set corresponding to a given pre- and post-compression RF frame set. When tested on simulated, phantom, and in vivo breast datasets, the ranges of the accuracy, precision, recall, and F1 scores produced by the trained CNN model were 77-99%, 68-98%, 97-100%, and 81-99%, respectively. The RMSE, MAE, SNR, CNR, and SR values calculated from the optimal strain images suggested by AutoSOUL were within 1.5-4%, 6-9%, 0-30%, 0-21%, and 0-6%, respectively, of values obtained from corresponding manually tuned strain images. AutoSOUL reduced the execution time of the otherwise required manual tuning and selection process of SOUL by a factor of 84.4. These results indicate that AutoSOUL has the potential to enhance the usability of ultrasound elastography, facilitating more efficient clinical evaluation of tissue abnormalities.


  • Open Access

    Generalized contrast-to-noise ratio applied to short-lag spatial coherence ultrasound differentiates breast cysts from solid masses

    by Arunima Sharma, Eniola T Oluyemi, Madhavi Tripathi, Emily B Ambinder, Lisa A Mullen, Babita Panigrahi, Joanna Rossi, Nethra Venkatayogi, Kelly S Myers, Muyinatu A Lediju Bell

    Background: Benefits of ultrasound in breast cancer detection are often limited by the similar appearance of complicated cysts and solid hypoechoic masses with B-mode imaging, which can lead to false positive diagnoses. Purpose: To evaluate the diagnostic performance of generalized contrast-to-noise ratio (gCNR) on short-lag spatial coherence (SLSC) ultrasound images as an objective tool to improve complicated cyst vs solid mass classification. Materials and Methods: For this secondary analysis of a prospective recruitment for the Advanced Ultrasound Signal Processing of Suspicious Breast Images (AUSPICIOUS) observational study (NCT07206888), women scheduled for ultrasound-guided procedures or follow-up of at least 1 breast mass were enrolled from March 2018 to October 2023. Raw ultrasound data were acquired with an Alpinion ECUBE12R research scanner, then post-processed with our custom software. The primary evaluation indicator was gCNR applied to SLSC images with regions of interest determined by 6 radiologists. Outcomes were compared to the same radiologists classifying mass contents as solid, fluid, mixed, or uncertain using B-mode images. The reference standard was determined by aspiration, pathology, or characterization of image features. Areas under receiver operating characteristic curves (AUCs) with 95% confidence intervals (CIs) and inter-reader agreement (Fleiss’ κ) were assessed. Results: Among 175 cases, 145 breast masses from 115 women (age: 52 ± 17 years) were analyzed, including 16 complicated cysts and 96 solid masses. The mean AUC for complicated cyst vs solid mass characterization was 0.96 (95% CI: 0.94, 0.97) with gCNR applied to SLSC images, relative to a mean lower-bound AUC of 0.67 (range: 0.54-0.76) with readings of B-mode images (P < .05). Inter-reader agreement improved from fair with B-mode (κ = 0.40) to moderate with gCNR applied to SLSC images with a 0.76 threshold (κ = 0.59, P < .00001). Conclusion: Applying an objective gCNR metric to SLSC images improved the differentiation of complicated cysts from solid masses when compared to subjective readings of B-mode images.


  • Impact of the COVID-19 Pandemic on Breast Biopsy Delays: Factors Contributing to Disparities Across Prepandemic, Shutdown, and Postshutdown Periods

    by Babita Panigrahi, Naveen Ghuman, Joanna Rossi, Kelly S. Myers, Lisa A. Mullen, Emily B. Ambinder, Eniola T. Oluyemi


  • Clinical and Imaging Features Associated With Malignant Focal Nonmass Enhancement on Breast MRI

    by Eumee Cha, Emily B. Ambinder, Eniola T. Oluyemi, Lisa A. Mullen, Babita Panigrahi, Joanna Rossi, Philip Di Carlo, Kelly S. Myers


  • Open Access

    MixTURE: L1-Norm-Based Mixed Second-Order Continuity in Strain Tensor Ultrasound Elastography

    by Ashikuzzaman, Arunima Sharma, Nethra Venkatayogi, Eniola Oluyemi, Kelly Myers, Emily Ambinder, Hassan Rivaz, Muyinatu A. Lediju Bell

    Energy-based displacement tracking of ultrasound images can be implemented by optimizing a cost function consisting of a data term, a mechanical congruency term, and first- and second-order continuity terms. This approach recently provided a promising solution to two-dimensional axial and lateral displacement tracking in ultrasound strain elastography. However, the associated second-order regularizer only considers the unmixed second derivatives and disregards the mixed derivatives, thereby providing suboptimal noise suppression and limiting possibilities for total strain tensor imaging. We propose to improve axial, lateral, axial shear, and lateral shear strain estimation quality by formulating and optimizing a novel L 1-norm-based second-order regularizer that penalizes both mixed and unmixed displacement derivatives. We name the proposed technique L 1-MixTURE, which stands for L 1-norm Mixed derivative for Total UltRasound Elastography. When compared to simulated ground truth results, the mean structural similarity (MSSIM) obtained with L 1-MixTURE ranged 0.53 to 0.86 and the mean absolute error (MAE) ranged 0.00053 to 0.005. In addition, the mean elastographic signal-to-noise ratio (SNR) achieved with simulated, experimental phantom, and in vivo breast datasets, ranged 1.87 to 52.98, and the mean elastographic contrast-to-noise ratio (CNR) ranged 7.40 to 24.53. When compared to a closely related existing technique that does not consider the mixed derivatives, L 1-MixTURE generally outperformed the MSSIM, MAE, SNR, and CNR by up to 37.96%, 67.82%, and 25.53% in the simulated, experimental phantom, and in vivo datasets, respectively. These results collectively highlight the ability of L 1-MixTURE to deliver highly accurate axial, lateral, axial shear, and lateral shear strain estimates and advance the state-of-the-art in elastography-guided diagnostic and interventional decisions.


  • Clinical Outcomes of Benign Concordant MRI-Guided Breast Biopsies

    by Eumee Cha, Eniola T. Oluyemi, Emily B. Ambinder, Kelly S. Myers