Kazuaki Morizane
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kazuaki Morizane has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
Shuichi Matsuda
Department of Orthopaedic Surgery, Graduate School of Medicine, Kyoto University, Sakyo, Kyoto, Japan
7 shared publicationsShunsuke Fujibayashi
Department of Orthopaedic Surgery Kyoto University Graduate School of Medicine Kyoto Japan
6 shared publicationsBungo Otsuki
Department of Orthopaedic Surgery Kyoto University Graduate School of Medicine Kyoto Japan
5 shared publications- Bungo Otsuki
Department of Orthopaedic Surgery, Kyoto University, Graduate School of Medicine, Kyoto, Japan
4 shared publications - Takayoshi Shimizu
Department of Orthopaedic Surgery, Kyoto University, Graduate School of Medicine, Kyoto, Japan
4 shared publications - Toshiyuki Kawai
Department of Orthopaedic Surgery Kyoto University Graduate School of Medicine Kyoto Japan
4 shared publications
Latest Publications
- Open Access
- 27 May 2026
- Published by Elsevier in World Neurosurgery
- Vol. 212, 125079
Comparative Study of Posterior Lumbar Interbody Fusion Using Expandable Cages versus Lateral Lumbar Interbody Fusion for Lumbar Canal Stenosis Associated with Osteoporotic Vertebral Fractures: A Multicenter Retrospective Cohort Study
- 27 May 2026
- Published by Elsevier in World Neurosurgery
- Vol. 212, 125079
Open AccessComparative Study of Posterior Lumbar Interbody Fusion Using Expandable Cages versus Lateral Lumbar Interbody Fusion for Lumbar Canal Stenosis Associated with Osteoporotic Vertebral Fractures: A Multicenter Retrospective Cohort Study
- Open Access
- 31 October 2025
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 19 (5) , 755-764
Measures to prevent acute airway obstruction after anterior cervical spine surgery: a retrospective cohort study from Japan and a review of the literature
Study Design: A retrospective cohort study and literature review.Purpose: We analyzed the clinical characteristics of acute airway obstruction (AAO) after anterior cervical spine surgery (ACSS), evaluated the effectiveness of newly implemented preventive measures, and assessed whether extubation immediately after surgery is practical.Overview of Literature: AAO is a rare but potentially fatal complication after ACSS. Recent studies have focused on postoperative management strategies such as prolonged intubation in the intensive care unit; however, the feasibility and safety of immediate extubation have not been studied extensively. This study addressed this critical gap.Methods: We retrospectively reviewed data from patients who underwent ACSS and then immediate extubation according to policy at our institution between April 2006 and January 2019. Patients were categorized into AAO and non-AAO groups according to whether postoperative airway compromise necessitated reintubation or hematoma evacuation. Statistical analyses identified surgery-related risk factors associated with AAO. These findings and a review of the literature prompted the implementation of 10 preventive measures in February 2019. We then analyzed outcomes from 156 subsequent cases of ACSS.Results: AAO occurred in 7 (0.68%) of 1,036 patients. Significant risk factors included the number of fixed disc segments (p =0.031), instrumentation of a more cephalad upper vertebra (p =0.007), and use of a halo vest (p <0.001). Among 156 patients who underwent ACSS after preventive measures were implemented, no cases of AAO were observed, but statistical significance could not be determined because of the limited sample size.Conclusions: We systematically examined AAO prevention strategies and the potential effectiveness of 10 preventive measures. Despite these preventive measures, AAO cannot be prevented entirely; thus, rigorous monitoring after extubation is essential. Although the trend toward prolonged intubation is increasing, our findings suggest that immediate extubation is suitable for most patients.
- 31 October 2025
- Published by Asian Spine Journal (ASJ) in Asian Spine Journal
- Vol. 19 (5) , 755-764
Open AccessMeasures to prevent acute airway obstruction after anterior cervical spine surgery: a retrospective cohort study from Japan and a review of the literature
Study Design: A retrospective cohort study and literature review.Purpose: We analyzed the clinical characteristics of acute airway obstruction (AAO) after anterior cervical spine surgery (ACSS), evaluated the effectiveness of newly implemented preventive measures, and assessed whether extubation immediately after surgery is practical.Overview of Literature: AAO is a rare but potentially fatal complication after ACSS. Recent studies have focused on postoperative management strategies such as prolonged intubation in the intensive care unit; however, the feasibility and safety of immediate extubation have not been studied extensively. This study addressed this critical gap.Methods: We retrospectively reviewed data from patients who underwent ACSS and then immediate extubation according to policy at our institution between April 2006 and January 2019. Patients were categorized into AAO and non-AAO groups according to whether postoperative airway compromise necessitated reintubation or hematoma evacuation. Statistical analyses identified surgery-related risk factors associated with AAO. These findings and a review of the literature prompted the implementation of 10 preventive measures in February 2019. We then analyzed outcomes from 156 subsequent cases of ACSS.Results: AAO occurred in 7 (0.68%) of 1,036 patients. Significant risk factors included the number of fixed disc segments (p =0.031), instrumentation of a more cephalad upper vertebra (p =0.007), and use of a halo vest (p <0.001). Among 156 patients who underwent ACSS after preventive measures were implemented, no cases of AAO were observed, but statistical significance could not be determined because of the limited sample size.Conclusions: We systematically examined AAO prevention strategies and the potential effectiveness of 10 preventive measures. Despite these preventive measures, AAO cannot be prevented entirely; thus, rigorous monitoring after extubation is essential. Although the trend toward prolonged intubation is increasing, our findings suggest that immediate extubation is suitable for most patients.
- Open Access
- 27 September 2025
- Published by Elsevier in World Neurosurgery
- Vol. 204, 124520
Results of Spine Surgeries in Nonagenarians Compared with Octogenarians: A Propensity-Matched Analysis
- 27 September 2025
- Published by Elsevier in World Neurosurgery
- Vol. 204, 124520
Open AccessResults of Spine Surgeries in Nonagenarians Compared with Octogenarians: A Propensity-Matched Analysis
- Open Access
Bone Coverage around Hydroxyapatite/Poly(L-Lactide) Composite Is Determined According to Depth from Cortical Bone Surface in Rabbits
Composites of unsintered hydroxyapatite (HA) and poly(L-lactide) (PLLA) reinforced by compression forging are biodegradable, bioactive, and have ultrahigh strength. However, foreign body reactions to PLLA and physical irritation can occur when not covered by bone. We aimed to confirm the relationships between the depth of the implanted HA-PLLA threaded pins and the new bone formation. We inserted HA-PLLA composite threaded pins (diameter: 2.0 or 4.5 mm) into the femoral and tibial bones of 32 mature male Japanese white rabbits (weight 3.0–3.5 kg) with the pin head 1 or 0 mm below or protruding 1 or 2 mm above surrounding cortical bone. Eight euthanized rabbits were radiologically and histologically assessed at various intervals after implantation. Bone bridging was complete over pins of both diameters at ~12 weeks, when inserted 1 mm below the surface, but the coverage of the pins inserted at 0 mm varied. Bone was not formed when the pins protruded >1 mm from the bone surface. No inflammation developed around the pins by 25 weeks. However, foreign body reactions might develop if composites are fixed above the bone surface, and intraosseous fixation would be desirable using double-threaded screws or a countersink to avoid screw head protrusion.
Open AccessBone Coverage around Hydroxyapatite/Poly(L-Lactide) Composite Is Determined According to Depth from Cortical Bone Surface in Rabbits
Composites of unsintered hydroxyapatite (HA) and poly(L-lactide) (PLLA) reinforced by compression forging are biodegradable, bioactive, and have ultrahigh strength. However, foreign body reactions to PLLA and physical irritation can occur when not covered by bone. We aimed to confirm the relationships between the depth of the implanted HA-PLLA threaded pins and the new bone formation. We inserted HA-PLLA composite threaded pins (diameter: 2.0 or 4.5 mm) into the femoral and tibial bones of 32 mature male Japanese white rabbits (weight 3.0–3.5 kg) with the pin head 1 or 0 mm below or protruding 1 or 2 mm above surrounding cortical bone. Eight euthanized rabbits were radiologically and histologically assessed at various intervals after implantation. Bone bridging was complete over pins of both diameters at ~12 weeks, when inserted 1 mm below the surface, but the coverage of the pins inserted at 0 mm varied. Bone was not formed when the pins protruded >1 mm from the bone surface. No inflammation developed around the pins by 25 weeks. However, foreign body reactions might develop if composites are fixed above the bone surface, and intraosseous fixation would be desirable using double-threaded screws or a countersink to avoid screw head protrusion.
- 6 August 2020
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 109 (2) , 238-245
Bioactivity and antibacterial activity of strontium and silver ion releasing titanium
To overcome problems associated with loosening of orthopedic implants and surgical site infections, we developed a novel, titanium (Ti)‐based material that releases both strontium and silver ions (CaSrAg–Ti) based on alkali‐and‐heat treatment. The results of commercially pure Ti (cp–Ti), Ti that releases Sr ions only (CaSr–Ti), and the novel CaSrAg–Ti material were compared. Mechanical tests were performed to evaluate the in vivo bonding properties of CaSrAg–Ti and the bone‐implant contact (BIC) ratio in histological specimens was determined at 4 and 8 weeks after implantation in a rat femur. Also, the in vitro antibacterial activities of this material against methicillin‐susceptible Staphylococcus aureus (MSSA) were evaluated after a 24 h incubation period by assaying colony‐forming units. In addition, antibacterial activities were evaluated in vivo at 7 days after implantation in a rat subcutaneous pocket model. There was direct contact between the bone and CaSrAg–Ti in histological specimens and no apparent signs of argyrosis in any rat. The bone‐bonding strength and the BIC ratio were increased by 2.7‐ and 2.3‐fold for CaSrAg–Ti vs. cp‐Ti at 4 weeks and 2.2‐ and 2.0‐fold at 8 weeks, respectively. As compared with cp‐Ti, the number of viable MSSA remaining on CaSrAg–Ti was reduced by 100 ± 0% in vitro and 94.2 ± 6.9% in vivo. Ti that releases Sr and Ag ions is a promising material that exhibits both bone‐bonding properties and anti‐MSSA activities.
- 6 August 2020
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 109 (2) , 238-245
Bioactivity and antibacterial activity of strontium and silver ion releasing titanium
To overcome problems associated with loosening of orthopedic implants and surgical site infections, we developed a novel, titanium (Ti)‐based material that releases both strontium and silver ions (CaSrAg–Ti) based on alkali‐and‐heat treatment. The results of commercially pure Ti (cp–Ti), Ti that releases Sr ions only (CaSr–Ti), and the novel CaSrAg–Ti material were compared. Mechanical tests were performed to evaluate the in vivo bonding properties of CaSrAg–Ti and the bone‐implant contact (BIC) ratio in histological specimens was determined at 4 and 8 weeks after implantation in a rat femur. Also, the in vitro antibacterial activities of this material against methicillin‐susceptible Staphylococcus aureus (MSSA) were evaluated after a 24 h incubation period by assaying colony‐forming units. In addition, antibacterial activities were evaluated in vivo at 7 days after implantation in a rat subcutaneous pocket model. There was direct contact between the bone and CaSrAg–Ti in histological specimens and no apparent signs of argyrosis in any rat. The bone‐bonding strength and the BIC ratio were increased by 2.7‐ and 2.3‐fold for CaSrAg–Ti vs. cp‐Ti at 4 weeks and 2.2‐ and 2.0‐fold at 8 weeks, respectively. As compared with cp‐Ti, the number of viable MSSA remaining on CaSrAg–Ti was reduced by 100 ± 0% in vitro and 94.2 ± 6.9% in vivo. Ti that releases Sr and Ag ions is a promising material that exhibits both bone‐bonding properties and anti‐MSSA activities.
- 1 October 2019
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 31 (4) , 534-541
Occipital and external acoustic meatus to axis angle: a useful predictor of oropharyngeal space in rheumatoid arthritis patients with atlantoaxial subluxation
OBJECTIVE: Dyspnea and/or dysphagia is a life-threatening complication after occipitocervical fusion. The occiput-C2 angle (O-C2a) is useful for preventing dyspnea and/or dysphagia because O-C2a affects the oropharyngeal space. However, O-C2a is unreliable in atlantoaxial subluxation (AAS) because it does not reflect the translational motion of the cranium to C2, another factor affecting oropharyngeal area in patients with rheumatoid arthritis (RA) who have reducible AAS. The authors previously proposed the occipital and external acoustic meatus to axis angle (O-EAa; i.e., the angle made by McGregor’s line and a line joining the external auditory canal and the middle point of the endplate of the axis [EA line]) as a novel, useful, and powerful predictor of the anterior-posterior narrowest oropharyngeal airway space (nPAS) distance in healthy subjects. The aim of the present study was to elucidate the validity of O-EAa as an indicator of oropharyngeal airway space in RA patients with AAS.METHODS: The authors investigated 64 patients with RA. The authors collected lateral cervical radiographs at neutral position, flexion, extension, protrusion, and retraction and measured the O-C2a, C2-C6, O-EAa, anterior atlantodental interval (AADI), and nPAS. Patients were classified into 2 groups according to the presence of AAS and its mobility: group N, patients without AAS; and group R, patients with reducible AAS during dynamic cervical movement.RESULTS: Group N had a significantly lower AADI and O-EAa than group R in all but the extension position. The O-EAa was a better predictor for nPAS than O-C2a according to the mixed-effects models in both groups (marginal R2: 0.510 and 0.575 for the O-C2a and O-EAa models in group N, and 0.250 and 0.390 for the same models, respectively, in group R).CONCLUSIONS: O-EAa was superior to O-C2a in predicting nPAS, especially in the case of AAS, because it affects both O-C2a and cranial translational motion. O-EAa would be a useful parameter for surgeons performing occipitocervical fusion in patients with AAS.
- 1 October 2019
- Published by Journal of Neurosurgery Publishing Group (JNSPG) in Journal of Neurosurgery: Spine
- Vol. 31 (4) , 534-541
Occipital and external acoustic meatus to axis angle: a useful predictor of oropharyngeal space in rheumatoid arthritis patients with atlantoaxial subluxation
OBJECTIVE: Dyspnea and/or dysphagia is a life-threatening complication after occipitocervical fusion. The occiput-C2 angle (O-C2a) is useful for preventing dyspnea and/or dysphagia because O-C2a affects the oropharyngeal space. However, O-C2a is unreliable in atlantoaxial subluxation (AAS) because it does not reflect the translational motion of the cranium to C2, another factor affecting oropharyngeal area in patients with rheumatoid arthritis (RA) who have reducible AAS. The authors previously proposed the occipital and external acoustic meatus to axis angle (O-EAa; i.e., the angle made by McGregor’s line and a line joining the external auditory canal and the middle point of the endplate of the axis [EA line]) as a novel, useful, and powerful predictor of the anterior-posterior narrowest oropharyngeal airway space (nPAS) distance in healthy subjects. The aim of the present study was to elucidate the validity of O-EAa as an indicator of oropharyngeal airway space in RA patients with AAS.METHODS: The authors investigated 64 patients with RA. The authors collected lateral cervical radiographs at neutral position, flexion, extension, protrusion, and retraction and measured the O-C2a, C2-C6, O-EAa, anterior atlantodental interval (AADI), and nPAS. Patients were classified into 2 groups according to the presence of AAS and its mobility: group N, patients without AAS; and group R, patients with reducible AAS during dynamic cervical movement.RESULTS: Group N had a significantly lower AADI and O-EAa than group R in all but the extension position. The O-EAa was a better predictor for nPAS than O-C2a according to the mixed-effects models in both groups (marginal R2: 0.510 and 0.575 for the O-C2a and O-EAa models in group N, and 0.250 and 0.390 for the same models, respectively, in group R).CONCLUSIONS: O-EAa was superior to O-C2a in predicting nPAS, especially in the case of AAS, because it affects both O-C2a and cranial translational motion. O-EAa would be a useful parameter for surgeons performing occipitocervical fusion in patients with AAS.
- 1 June 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 91, 48-59
In vivo and in vitro bioactivity of a “precursor of apatite” treatment on polyetheretherketone
- 1 June 2019
- Published by Elsevier in Acta Biomaterialia
- Vol. 91, 48-59
In vivo and in vitro bioactivity of a “precursor of apatite” treatment on polyetheretherketone