Vikas Singh Bhadoria
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vikas Singh Bhadoria has a total of 96 co-authors. Here are the top co-authors by number of shared publications:
Shiva Pujan Jaiswal
Sharda University, India
8 shared publications- Georgios Fotis
Centre for Energy Technologies, Aarhus University, Birk Centerpark 15, Innovatorium, 7400 Herning, Denmark
7 shared publications Nidhi Singh Pal
Gautam Buddha University
7 shared publicationsVivek Shrivastava
National Institute of Technology
7 shared publicationsShubham Tiwari
Department of Electrical and Electronics Engineering, ABES Engineering College, Ghaziabad, Uttar Pradesh, India
5 shared publicationsJay Singh
GL Bajaj Institute of Technology and Management,Greater Noida
4 shared publications
Latest Publications
- Open Access
- 1 October 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8  (19) , 195327
Hierarchy-guided hybridisation of grey wolf and artificial bee colony optimisers for demand-side load shifting: certified optimality gaps and the consumer-flexibility requirement
Load shifting is the most widely adopted demand-side management technique for relieving utility peak load in smart grids, and hybrid metaheuristics are routinely proposed for the underlying scheduling problem. This paper studies that problem on a residential test system of 2604 shiftable appliances across 14 types under time-of-use pricing. The baseline appliance schedule of the standard test system is reconstructed by a documented rule and released with the complete code, data and random seeds, making the instance fully reproducible. A convex continuous relaxation of the schedule polytope is solved by projected gradient descent to give a certified lower bound, against which the optimality gap of a metaheuristic schedule is measured for the first time in this line of work. A hierarchy-guided hybrid optimiser, hGWOABC-II, is then proposed, injecting the consensus of the grey wolf optimiser’s alpha–beta–delta hierarchy into the artificial bee colony solution-update rule; under equal function-evaluation budgets over 30 independent runs it is statistically superior to GWO, ABC and the conventional sequential GWO–ABC hybrid (Wilcoxon rank-sum, p < 0.01), reaching within 6.4% of the bound with a 19.7% peak-load reduction and a 5.6% consumer cost saving. A consumer-flexibility analysis shows that six to eight hours of appliance-delay tolerance captures about 90% of the peak-shaving value of full-day flexibility, giving demand-response designers a quantitative basis for setting delay caps.
- 1 October 2026
- Published by IOP Publishing in Engineering Research Express
- Vol. 8  (19) , 195327
Open AccessHierarchy-guided hybridisation of grey wolf and artificial bee colony optimisers for demand-side load shifting: certified optimality gaps and the consumer-flexibility requirement
Load shifting is the most widely adopted demand-side management technique for relieving utility peak load in smart grids, and hybrid metaheuristics are routinely proposed for the underlying scheduling problem. This paper studies that problem on a residential test system of 2604 shiftable appliances across 14 types under time-of-use pricing. The baseline appliance schedule of the standard test system is reconstructed by a documented rule and released with the complete code, data and random seeds, making the instance fully reproducible. A convex continuous relaxation of the schedule polytope is solved by projected gradient descent to give a certified lower bound, against which the optimality gap of a metaheuristic schedule is measured for the first time in this line of work. A hierarchy-guided hybrid optimiser, hGWOABC-II, is then proposed, injecting the consensus of the grey wolf optimiser’s alpha–beta–delta hierarchy into the artificial bee colony solution-update rule; under equal function-evaluation budgets over 30 independent runs it is statistically superior to GWO, ABC and the conventional sequential GWO–ABC hybrid (Wilcoxon rank-sum, p < 0.01), reaching within 6.4% of the bound with a 19.7% peak-load reduction and a 5.6% consumer cost saving. A consumer-flexibility analysis shows that six to eight hours of appliance-delay tolerance captures about 90% of the peak-shaving value of full-day flexibility, giving demand-response designers a quantitative basis for setting delay caps.
- 16 September 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108  (10) , 417
Real-time adaptive energy management for pv-based renewable systems using Bi-GRU forecasting, quantum differential evolution, and Neuro-Fuzzy control in labview
- 16 September 2026
- Published by Springer Nature in Electrical Engineering
- Vol. 108  (10) , 417
Real-time adaptive energy management for pv-based renewable systems using Bi-GRU forecasting, quantum differential evolution, and Neuro-Fuzzy control in labview
- Open Access
- 4 August 2025
- Published by Springer Nature in International Journal of System Assurance Engineering and Management
- Vol. 17  (8) , 1
Correction: Renewable sources-based efficient electric vehicle charging system through power forecasting and charge scheduling
- 4 August 2025
- Published by Springer Nature in International Journal of System Assurance Engineering and Management
- Vol. 17  (8) , 1
Open AccessCorrection: Renewable sources-based efficient electric vehicle charging system through power forecasting and charge scheduling
- 18 October 2024
- Published by Springer Nature in International Journal of System Assurance Engineering and Management
- Vol. 15  (12) , 5528-5547
Renewable sources-based efficient electric vehicle charging system through power forecasting and charge scheduling
- 18 October 2024
- Published by Springer Nature in International Journal of System Assurance Engineering and Management
- Vol. 15  (12) , 5528-5547
Renewable sources-based efficient electric vehicle charging system through power forecasting and charge scheduling
- Open Access
- 12 April 2024
- Published by Hindawi Limited in International Journal of Intelligent Systems
- Vol. 2024, 1-29
Comparison of Bioinspired Techniques for Tracking Maximum Power under Variable Environmental Conditions
This paper presents a comparative analysis of bioinspired algorithms employed on a PV system subject to standard conditions, under step-change of irradiance conditions, and a partial shading condition for tracking the global maximum power point (GMPP). Four performance analysis and comparison techniques are artificial bee colony, particle swarm optimization, genetic algorithm, and a new metaheuristic technique called jellyfish optimization, respectively. These existing algorithms are well-known for tracking the GMPP with high efficiency. This paper compares these algorithms based on extracting GMPP in terms of maximum power from a PV module running at a uniform (STC), nonuniform solar irradiation (under step-change of irradiance), and partial shading conditions (PSCs). For analysis and comparison, two modules are taken: 1Soltech-1STH-215P and SolarWorld Industries GmbH Sunmodule plus SW 245 poly module, which are considered to form a panel by connecting four series modules. Comparison is based on maximum power tracking, total execution time, and minimum number of iterations to achieve the GMPP with high tracking efficiency and minimum error. Minitab software finds the regression equation (objective function) for STC, step-changing irradiation, and PSC. The reliability of the data (P-V curves) was measured in terms of p value, R, , and VIF. The value comes out to be near 1, which shows the accuracy of the data. The simulation results prove that the new evolutionary jellyfish optimization technique gives better results in terms of higher tracking efficiency with very less time to obtain GMPP in all environmental conditions, with a higher efficiency of 98 to 99.9% with less time of 0.0386 to 0.1219 sec in comparison to ABC, GA, and PSO. The RMSE value for the proposed method JFO (0.59) is much lower than that of ABC, GA, and PSO.- 12 April 2024
- Published by Hindawi Limited in International Journal of Intelligent Systems
- Vol. 2024, 1-29
Open AccessComparison of Bioinspired Techniques for Tracking Maximum Power under Variable Environmental Conditions
This paper presents a comparative analysis of bioinspired algorithms employed on a PV system subject to standard conditions, under step-change of irradiance conditions, and a partial shading condition for tracking the global maximum power point (GMPP). Four performance analysis and comparison techniques are artificial bee colony, particle swarm optimization, genetic algorithm, and a new metaheuristic technique called jellyfish optimization, respectively. These existing algorithms are well-known for tracking the GMPP with high efficiency. This paper compares these algorithms based on extracting GMPP in terms of maximum power from a PV module running at a uniform (STC), nonuniform solar irradiation (under step-change of irradiance), and partial shading conditions (PSCs). For analysis and comparison, two modules are taken: 1Soltech-1STH-215P and SolarWorld Industries GmbH Sunmodule plus SW 245 poly module, which are considered to form a panel by connecting four series modules. Comparison is based on maximum power tracking, total execution time, and minimum number of iterations to achieve the GMPP with high tracking efficiency and minimum error. Minitab software finds the regression equation (objective function) for STC, step-changing irradiation, and PSC. The reliability of the data (P-V curves) was measured in terms of p value, R, , and VIF. The value comes out to be near 1, which shows the accuracy of the data. The simulation results prove that the new evolutionary jellyfish optimization technique gives better results in terms of higher tracking efficiency with very less time to obtain GMPP in all environmental conditions, with a higher efficiency of 98 to 99.9% with less time of 0.0386 to 0.1219 sec in comparison to ABC, GA, and PSO. The RMSE value for the proposed method JFO (0.59) is much lower than that of ABC, GA, and PSO. - Open Access
- 19 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 15561-15571
Improved Relay Algorithm for Detection and Classification of Transmission Line Faults in Monopolar HVDC Transmission System Using Signum Function of Transient Energy
Based on the signum function (sign of magnitudes) of transient energy, this paper proposes a fault classification approach and algorithm for a monopolar HVDC system. The analytical study here shows that the signum function of variation in transient energy has a zero value individually at both ends on no-fault conditions. Moreover, the summation of the signum functions computed for internal DC faults is zero, whereas the same has a non-zero value for external AC faults. The performance of the proposed algorithm has been extensively evaluated by simulating faults on a CIGRE benchmark system for HVDC monopolar configuration using EMTDC/PSCAD software. Three locations of DC line fault, and AC fault at the two ends of the system have been considered for this evaluation. Five fault resistance values (0, 10, 100, 1000, and 2000 ohms) have been simulated for each fault location. The results conform with the theoretical analysis, and the fault classification by the algorithm is 100% accurate. The time taken to detect and classify a DC fault at the mid-point of the 800-km line is 1.5 ms, and that for line-end faults on the DC line is 3 ms for all values of fault resistance. These results show a marked improvement over those reported earlier in the literature using other techniques. A comparison table is given in the last section to corroborate it.
- 19 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 15561-15571
Open AccessImproved Relay Algorithm for Detection and Classification of Transmission Line Faults in Monopolar HVDC Transmission System Using Signum Function of Transient Energy
Based on the signum function (sign of magnitudes) of transient energy, this paper proposes a fault classification approach and algorithm for a monopolar HVDC system. The analytical study here shows that the signum function of variation in transient energy has a zero value individually at both ends on no-fault conditions. Moreover, the summation of the signum functions computed for internal DC faults is zero, whereas the same has a non-zero value for external AC faults. The performance of the proposed algorithm has been extensively evaluated by simulating faults on a CIGRE benchmark system for HVDC monopolar configuration using EMTDC/PSCAD software. Three locations of DC line fault, and AC fault at the two ends of the system have been considered for this evaluation. Five fault resistance values (0, 10, 100, 1000, and 2000 ohms) have been simulated for each fault location. The results conform with the theoretical analysis, and the fault classification by the algorithm is 100% accurate. The time taken to detect and classify a DC fault at the mid-point of the 800-km line is 1.5 ms, and that for line-end faults on the DC line is 3 ms for all values of fault resistance. These results show a marked improvement over those reported earlier in the literature using other techniques. A comparison table is given in the last section to corroborate it.
- Open Access
- 18 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 95507-95525
Analysis of the Factors Influencing the Performance of Single- and Multi-Diode PV Solar Modules
This paper presents a comparative analysis of single, double, and three-diode models for commercial and industrial photovoltaic (PV) cells. The efficiency of a PV system depends on various factors, including fill factor, material effect, temperature coefficient, interconnections, module degradation, solar irradiation, module temperature, soiling, potential induced degradation, PV module tilt angle, parasitic resistance, and shading effect. The results show that adding diodes decreases the maximum allowable power taken from a PV cell, resulting in the single-diode model with the highest efficiency of 99.9% at STC. As the temperature increases, the voltage decreases and the maximum power decreases to 4.044 watts/°C, while with the rise in irradiation, the maximum power value increases to 80.04 watts/100w/m 2 . A rise in temperature affects voltage and current values, while irradiation affects current values. An increase in series resistance decreases maximum power values by 216.785 watts/0.1-ohm, while shunt resistance increases maximum power by 0.0725 watts/100 ohm without significant change in current value. Pmax , Vmax , and Imax values increase with a decrease in shading value. Two and three-diodes respond more effectively than single diodes at the lowest and maximum shading values. Total-Cross-Tied configurations perform more efficiently in various connections, while HC and BL connections have comparable I-V performance. However, BL and HC have low maximum power. MATLAB software is used for modeling and simulation, assisting researchers in understanding factors affecting solar PV system efficiency and diode models.
- 18 August 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 11, 95507-95525
Open AccessAnalysis of the Factors Influencing the Performance of Single- and Multi-Diode PV Solar Modules
This paper presents a comparative analysis of single, double, and three-diode models for commercial and industrial photovoltaic (PV) cells. The efficiency of a PV system depends on various factors, including fill factor, material effect, temperature coefficient, interconnections, module degradation, solar irradiation, module temperature, soiling, potential induced degradation, PV module tilt angle, parasitic resistance, and shading effect. The results show that adding diodes decreases the maximum allowable power taken from a PV cell, resulting in the single-diode model with the highest efficiency of 99.9% at STC. As the temperature increases, the voltage decreases and the maximum power decreases to 4.044 watts/°C, while with the rise in irradiation, the maximum power value increases to 80.04 watts/100w/m 2 . A rise in temperature affects voltage and current values, while irradiation affects current values. An increase in series resistance decreases maximum power values by 216.785 watts/0.1-ohm, while shunt resistance increases maximum power by 0.0725 watts/100 ohm without significant change in current value. Pmax , Vmax , and Imax values increase with a decrease in shading value. Two and three-diodes respond more effectively than single diodes at the lowest and maximum shading values. Total-Cross-Tied configurations perform more efficiently in various connections, while HC and BL connections have comparable I-V performance. However, BL and HC have low maximum power. MATLAB software is used for modeling and simulation, assisting researchers in understanding factors affecting solar PV system efficiency and diode models.
- Open Access
- 25 July 2023
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2023, 1-21
A Novel Metaheuristic Jellyfish Optimization Algorithm for Parameter Extraction of Solar Module
Accurate parameter identification plays an integral role in the modeling of an optimized solar module which in turn helps in the error-free prediction of its output. Five important parameters: the photoelectric current (Iph), ideality factor(α), saturation current (Io), series resistance (Rs), and shunt resistance (Rsh) are required for the accurate modeling of the PV cells/modules and need to be extracted as these parameters are not provided by the manufacturer in the datasheet. This paper proposes a new metaheuristic jellyfish optimization (JFO) algorithm for the parameter extraction of a solar module. The JFO algorithm achieves the optimal solution without being trapped in local solutions in less time. The parameter extraction using the JFO algorithm is done on two different solar modules i.e., Soltech-1STH-215P and PWP-201. The results are compared in terms of extracted parameters (Iph, α, Io, Rs, and Rsh) with the well-known optimization techniques like PSO, GA, and others available in the literature and with the manufacturer IV and PV characteristics. The proposed technique IV and PV characteristics are validated at different environmental conditions and are found to be similar to that of PSO and GA. It is also observed that the extracted parameters obtained using JFO are comparable with the other twenty-two techniques, and the proposed technique is one of the highly efficient techniques that can be utilized for parameter extraction of PV modules and to predict solar cell characteristics for all commercial modules without setting up any experimental measurements. MATLAB/simulation software is used for implementation and performance validation.
- 25 July 2023
- Published by Wiley in International Transactions on Electrical Energy Systems
- Vol. 2023, 1-21
Open AccessA Novel Metaheuristic Jellyfish Optimization Algorithm for Parameter Extraction of Solar Module
Accurate parameter identification plays an integral role in the modeling of an optimized solar module which in turn helps in the error-free prediction of its output. Five important parameters: the photoelectric current (Iph), ideality factor(α), saturation current (Io), series resistance (Rs), and shunt resistance (Rsh) are required for the accurate modeling of the PV cells/modules and need to be extracted as these parameters are not provided by the manufacturer in the datasheet. This paper proposes a new metaheuristic jellyfish optimization (JFO) algorithm for the parameter extraction of a solar module. The JFO algorithm achieves the optimal solution without being trapped in local solutions in less time. The parameter extraction using the JFO algorithm is done on two different solar modules i.e., Soltech-1STH-215P and PWP-201. The results are compared in terms of extracted parameters (Iph, α, Io, Rs, and Rsh) with the well-known optimization techniques like PSO, GA, and others available in the literature and with the manufacturer IV and PV characteristics. The proposed technique IV and PV characteristics are validated at different environmental conditions and are found to be similar to that of PSO and GA. It is also observed that the extracted parameters obtained using JFO are comparable with the other twenty-two techniques, and the proposed technique is one of the highly efficient techniques that can be utilized for parameter extraction of PV modules and to predict solar cell characteristics for all commercial modules without setting up any experimental measurements. MATLAB/simulation software is used for implementation and performance validation.
- Open Access
A Hybrid Artificial Ecosystem Optimizer and Incremental-Conductance Maximum-Power-Point-Tracking-Controlled Grid-Connected Photovoltaic System
When tracking the peak power point in PV systems, incremental conductance is the most common technique used. This approach preserves the first trap in the local peak power point, but it is unable to quickly keep up with the ever-changing peak power point under varying irradiance and temperature conditions. In this paper, the authors propose a hybrid algorithm, combining an artificial ecosystem optimizer and an incremental-conductance-based MPPT to solve these issues of traditional MPPT under varying irradiance and temperature conditions. The proposed hybrid algorithm has been applied to three scenarios, namely the constant irradiance condition, the varying irradiance condition, and the varying temperature condition. Under the constant irradiance condition, the PV array is maintained at a temperature of 25 °C and an irradiance of 1000 . The voltage of the DC link of the neutral-pointed-clamped inverter is maintained at 1000 V. Under the varying irradiance condition, the irradiance of the PV array is increased from 400to 1000 with a step size of 0.2 s. The same step size is maintained while decreasing the irradiance level from 1000 to 400 with a step change of 0.2 s. However, the temperature is maintained at 25 °C. Under the varying temperature condition, the temperature of the PV array varies from 35 °C, 25 °C, 15 °C, 10 °C, 15 °C, 25 °C, and 35 °C with a step size of 0.2 s, and the irradiance is maintained at 1000. The DC link voltage in all three conditions is maintained at 1000 V, which confirms that the hybrid algorithm has been able to vary the duty cycle of the pulse wave modulation generator in such a manner that the variable DC voltage produced by the PV array has been changed by the flyback converter into a stable DC voltage. The simulation results show that the total harmonic distortion (THD) under all the simulated scenarios is within 5%, which agrees with IEEE standards. In the future, this algorithm may be compared with other types of available MPPTs under partial shading.Open AccessA Hybrid Artificial Ecosystem Optimizer and Incremental-Conductance Maximum-Power-Point-Tracking-Controlled Grid-Connected Photovoltaic System
When tracking the peak power point in PV systems, incremental conductance is the most common technique used. This approach preserves the first trap in the local peak power point, but it is unable to quickly keep up with the ever-changing peak power point under varying irradiance and temperature conditions. In this paper, the authors propose a hybrid algorithm, combining an artificial ecosystem optimizer and an incremental-conductance-based MPPT to solve these issues of traditional MPPT under varying irradiance and temperature conditions. The proposed hybrid algorithm has been applied to three scenarios, namely the constant irradiance condition, the varying irradiance condition, and the varying temperature condition. Under the constant irradiance condition, the PV array is maintained at a temperature of 25 °C and an irradiance of 1000 . The voltage of the DC link of the neutral-pointed-clamped inverter is maintained at 1000 V. Under the varying irradiance condition, the irradiance of the PV array is increased from 400to 1000 with a step size of 0.2 s. The same step size is maintained while decreasing the irradiance level from 1000 to 400 with a step change of 0.2 s. However, the temperature is maintained at 25 °C. Under the varying temperature condition, the temperature of the PV array varies from 35 °C, 25 °C, 15 °C, 10 °C, 15 °C, 25 °C, and 35 °C with a step size of 0.2 s, and the irradiance is maintained at 1000. The DC link voltage in all three conditions is maintained at 1000 V, which confirms that the hybrid algorithm has been able to vary the duty cycle of the pulse wave modulation generator in such a manner that the variable DC voltage produced by the PV array has been changed by the flyback converter into a stable DC voltage. The simulation results show that the total harmonic distortion (THD) under all the simulated scenarios is within 5%, which agrees with IEEE standards. In the future, this algorithm may be compared with other types of available MPPTs under partial shading. - 23 May 2023
- Published by Springer Nature
- p. 235-242
Access to Solar Energy for Livelihood Security in Odisha, India
- 23 May 2023
- Published by Springer Nature
- p. 235-242
Access to Solar Energy for Livelihood Security in Odisha, India